Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Ear Hear ; 45(1): 239-249, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37641179

RESUMEN

OBJECTIVES: The stability of remote testing in cochlear implant care was studied by testing the influence of time-of-day, listener fatigue, and motivation on the outcomes of the aided threshold test (ATT) and digit triplets test (DTT) in cochlear implant (CI) recipients using self-tests at-home on a smartphone or tablet. DESIGN: A single-center repeated measures cohort study design (n = 50 adult CI recipients). The ATT and DTT were tested at-home ten times, with nine of these sessions planned within a period of eight days. Outcomes were modeled as a function of time-of-day, momentary motivation, listeners' task-related fatigue, and chronotype (i.e., someone's preference for morning or evening due to the sleep-wake cycle) using linear mixed models. Additional factors included aided monosyllabic word recognition in quiet, daily-life fatigue, age, and CI experience. RESULTS: Out of 500 planned measurements, 407 ATTs and 476 DTTs were completed. The ATT determined thresholds and impedances were stable across sessions. The factors in the DTT model explained 75% of the total variance. Forty-nine percent of the total variance was explained by individual differences in the participants' DTT performance. For each 10% increase in word recognition in quiet, the DTT speech reception threshold improved by an average of 1.6 dB. DTT speech reception threshold improved, on average by 0.1 dB per repeated session and correlated with the number of successful DTTs per participant. There was no significant time-of-day effect on auditory performance in at-home administered tests. CONCLUSIONS: This study is one of the first to report on the validity and stability of remote assessments in CI recipients and reveals relevant factors. CI recipients can be self-tested at any waking hour to monitor performance via smartphone or tablet. Motivation, task-related fatigue, and chronotype did not affect the outcomes of ATT or DTT in the studied cohort. Word recognition in quiet is a good predictor for deciding whether the DTT should be included in an individual's remote test battery. At-home testing is reliable for cochlear implant recipients and offers an opportunity to provide care in a virtual hearing clinic setting.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Estudios de Cohortes , Teléfono Inteligente , Audición
2.
Trends Hear ; 27: 23312165231198368, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37697865

RESUMEN

A cochlear implant (CI) is a prosthesis that allows people with severe to profound hearing loss to understand speech in quiet settings. However, listening to music presents a challenge to most CI users; they often do not enjoy music or avoid it altogether. The Musi-CI training course was developed for CI users with the goal of reducing music aversion and improving music enjoyment. A consortium was established consisting of a professional musician with CI, CI rehabilitation professionals and researchers. Participatory action research (PAR) was applied to develop and evaluate the training experiences, collaborating with 37 CI users during three cycles of eight training sessions, each held over a period of 3 months. Input and feedback were collected after each training session using questionnaires, observations and focus group interviews. Almost all participants (86%) completed the training. After completing the training a large majority of participants reported increased music appreciation, increased social participation in musical settings and a positive impact on general auditory perception. The resulting Musi-CI training programme focuses on music listening skills, self-efficacy, and self-motivation. It consists of exercises intended to strengthen attention and working memory, to improve beat and rhythm perception (with online rhythm exercises) and exercises to distinguish timbre of instruments and emotion in music. A Melody Game was developed to improve pitch and melodic contour discrimination.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Música , Humanos , Placer , Habla , Percepción Auditiva , Percepción de la Altura Tonal
3.
BMJ Open ; 13(6): e072689, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37369408

RESUMEN

INTRODUCTION: Cochlear implantation (CI) is a (cost-)effective intervention for people with severe or profound hearing loss. Since its introduction experience increased and the technology evolved, leading to better results and relaxation of CI eligibility criteria. Meanwhile, with national healthcare costs increasing there is a need for evidence of healthcare technology's value. This protocol describes a study to investigate clinical and participatory outcomes after CI for the currently (expanded) eligible hearing impaired population. The study adds to the current evidence base through its multicentre design, long-term follow-up and use of participatory outcomes alongside standard clinical outcomes. METHODS: This multicentre prospective observational cohort study will include at least 156 adult patients with severe-to-profound hearing loss, approximately evenly divided into two groups (1, ages 18-65 years and 2, age >65 years). The measurements consist of audiometry, cognition tests, listening effort tests and multiple generic and disease specific questionnaires. Questionnaires will be administered twice before CI, soon after inclusion at CI referral and shortly before CI surgery, with an annual follow-up of 3 years after CI. The Impact on Participation and Autonomy questionnaire will be used to assess participation. Generalised models (linear, logistic, Poisson) will be used. Mixed effects models will be used to investigate changes over time while exploring differences in subgroups and the influence of covariates. ETHICS AND DISSEMINATION: The study has received ethical approval from the Medical Ethical Committee of all participating centres. The results could provide valuable insights into changes in participatory outcomes of people with severe-to-profound hearing loss after CI. Results will be disseminated through peer-reviewed journals, scientific conferences and professional and patient organisation meetings. TRIAL REGISTRATION NUMBER: NCT05525221.


Asunto(s)
Implantación Coclear , Sordera , Pérdida Auditiva Sensorineural , Pérdida Auditiva , Adulto , Anciano , Humanos , Pérdida Auditiva/cirugía , Pérdida Auditiva Sensorineural/cirugía , Estudios Multicéntricos como Asunto , Estudios Observacionales como Asunto , Estudios Prospectivos , Calidad de Vida , Adolescente , Adulto Joven , Persona de Mediana Edad
4.
Laryngoscope ; 133(4): 924-932, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35792007

RESUMEN

OBJECTIVES: Eligibility criteria for cochlear implantation (CI) are shifting due to technological and surgical improvements. The aim of this study was to explore the impact of further expanding unilateral CI criteria in those with severe hearing loss (HL) (61-80 dBHL) in terms of number of CI recipients, costs, quality of life, and cost-effectiveness. METHODS: A dynamic population-based Markov model was constructed mimicking the Dutch population in three age categories over a period of 20 years. Health states included severe HL (61-80 dBHL), profound HL (>81 dBHL), CI recipients, and no-CI recipients. Model parameters were based on published literature, (national) databases, expert opinion, and model calibration. RESULTS: If persons with severe HL would qualify and opt for CI similar to those with profound HL now, this would lead to a 6-7 times increase of new CI recipients and an associated increase in costs (€550 million) and QALYs (54.000) over a 20-year period (incremental cost utility ratio: 10.771 euros/QALY [2.5-97.5 percentiles: 1.252-23.171]). One-way-sensitivity analysis indicated that model outcomes were most sensitive to regaining employment, utility associated with having a CI, and costs of surgery and testing. CONCLUSION: Our findings suggest that expanding eligibility for CI to persons with severe HL could be a cost-effective use of resources. Clearly, however, it would require a significant increase in diagnostic, operative, and rehabilitative capacity. Our quantitative estimates can serve as a basis for a wider societal deliberation on the question whether such an increase can and should be pursued. LEVEL OF EVIDENCE: NA Laryngoscope, 133:924-932, 2023.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Sensorineural , Pérdida Auditiva , Humanos , Adulto Joven , Adulto , Pérdida Auditiva Sensorineural/cirugía , Calidad de Vida , Análisis Costo-Beneficio , Pérdida Auditiva/cirugía
6.
Eur Arch Otorhinolaryngol ; 279(10): 4735-4743, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35041067

RESUMEN

PURPOSE: The aim of this study was to evaluate the intracochlear position of the Slim Modiolar Electrode (SME) after insertion via the extended Round Window (eRW) approach, and to correlate this with residual hearing preservation and speech perception outcomes. METHODS: Twenty-three adult participants, consecutively implanted with the SME via the eRW approach, were included in this prospective, single-center, observational study. Electrode position was evaluated intra-operatively using X-ray fluoroscopy and TIM measurement, and post-operatively using ultra-high resolution CT. Residual hearing [threshold shift in PTA between pre- and post-operative measurement, relative hearing preservation (RHP%)] and speech perception were evaluated at 2 and 12 months after surgery. RESULTS: In each of the 23 participants, complete scala tympani positioning of the electrode array could be achieved. In one participant, an initial tip fold-over was corrected during surgery. Average age at implantation was 63.3 years (SD 13.3, range 28-76) and mean preoperative residual hearing was 81.5 dB. The average post-operative PTA threshold shift was 16.2 dB (SD 10.8) at 2 months post-operatively, corresponding with a RHP% score of 44% (SD 34.9). At 12 months, the average RHP% score decreased to 37%. Postoperative phoneme scores improved from 27.1% preoperatively, to 72.1% and 82.1% at 2 and 12 months after surgery, respectively. CONCLUSION: Use of the eRW approach results in an increased likelihood of complete scala tympani insertion when inserting the SME, with subsequent excellent levels of speech perception. However, residual hearing preservation was found to be moderate, possibly as a result of the extended round window approach, emphasizing that it is not an all-purpose approach for inserting this particular electrode array.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Cóclea/cirugía , Implantación Coclear/métodos , Electrodos Implantados , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Estudios Prospectivos
7.
Radiology ; 302(3): 605-612, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34874202

RESUMEN

Background Histopathologic studies reported that cochlear implantation, a well-established means to treat severe-to-profound sensorineural hearing loss, may induce inflammation, fibrosis, and new bone formation (NBF) with possible impact on loss of residual hearing and hearing outcome. Purpose To assess NBF in vivo after cochlear implantation with ultra-high-spatial-resolution (UHSR) CT and its implication on long-term residual hearing outcome. Materials and Methods In a secondary analysis of a prospective single-center cross-sectional study, conducted between December 2016 and January 2018, patients with at least 1 year of cochlear implantation experience underwent temporal bone UHSR CT and residual hearing assessment. Two observers evaluated the presence and location of NBF independently, and tetrachoric correlations were used to assess interobserver reliability. In addition, the scalar location of each electrode was assessed. After consensus agreement, participants were classified into two groups: those with NBF (n = 83) and those without NBF (n = 40). The association between NBF and clinical parameters, including electrode design, surgical approach, and long-term residual hearing loss, was tested using the χ2 and Student t tests. Results A total of 123 participants (mean age ± standard deviation, 63 years ± 13; 63 women) were enrolled. NBF was found in 83 of the 123 participants (68%) at 466 of 2706 electrode contacts (17%). Most NBFs (428 of 466, 92%) were found around the 10 most basal contacts, with an interobserver agreement of 86% (2297 of 2683 contacts). Associations between electrode types and surgical approaches were significant (58 of 79 participants with NBF and a precurved electrode vs 24 of 43 with NBF and a straight electrode, P = .04; 64 of 88 participants with NBF and a cochleostomy approach vs 18 of 34 with NBF and a round window approach, P = .03). NBF was least often seen in full scala tympani insertions, but there was no significant association between scalar position and NBF (P = .15). Long-term residual hearing loss was significantly larger in the group with NBF compared with the group without NBF (mean, 22.9 dB ± 14 vs 8.6 dB ± 18, respectively; P = .04). Conclusion In vivo detection of new bone formation (NBF) after cochlear implantation is possible by using ultra-high-spatial-resolution CT. Most cochlear implant recipients develop NBF, predominately located at the base of the cochlea. NBF adversely affects long-term residual hearing preservation. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on December 8, 2021.


Asunto(s)
Implantación Coclear , Osteogénesis , Hueso Temporal/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Estudios Transversales , Femenino , Pruebas Auditivas , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
8.
Otol Neurotol ; 42(10): e1457-e1463, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34238897

RESUMEN

OBJECTIVE: The aim of this study was to compare Transimpedance Matrix (TIM-) measurement and X-ray fluoroscopy for the intraoperative detection of electrode array tip fold-over in cochlear implant recipients. STUDY DESIGN: Retrospective agreement study. SETTING: Tertiary referral hospital. PATIENTS: Forty-two patients (47 ears) consecutively implanted with the Slim Modiolar Electrode. INTERVENTIONS: Five raters, with different levels of clinical experience, individually retrospectively evaluated the TIM-heatmaps and X-ray fluoroscopy images of all patients included in this study for electrode array tip fold-over. MAIN OUTCOME MEASURES: Agreement between raters' individual evaluation and the diagnosis given during clinical intraoperative evaluation for both modalities, as well as the inter-method agreement between TIM-measurement and fluoroscopy, and the inter-rater agreement for both modalities. RESULTS: A tip fold-over was found in three of the forty-seven implantations (6.4%) included in this study. The average agreement between raters' evaluation and the intraoperative evaluation was 88% (Cohens κ = 0.378) for fluoroscopy and 99% (Cohens κ = 0.915) for TIM-measurement. Two raters misdiagnosed at least one tip fold-over as being correctly positioned when evaluating the fluoroscopy images (1/3 and 3/3, respectively). Each of the raters correctly detected all three tip fold-overs using the TIM-heatmaps. The inter-rater agreement for fluoroscopy was classified as "fair" (Fleiss' κ = 0.286), while the inter-rater agreement for TIM-measurement was classified as "near-perfect" (Fleiss' κ = 0.850). CONCLUSIONS: TIM-measurement has a high potential to replace X-ray fluoroscopy for intraoperatively detecting electrode array tip fold-over in cochlear implantation, especially in patients implanted with flexible, precurved arrays.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/cirugía , Implantación Coclear/métodos , Electrodos Implantados , Fluoroscopía , Humanos , Estudios Retrospectivos , Rayos X
9.
Ear Hear ; 42(6): 1499-1507, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33675587

RESUMEN

The global digital transformation enables computational audiology for advanced clinical applications that can reduce the global burden of hearing loss. In this article, we describe emerging hearing-related artificial intelligence applications and argue for their potential to improve access, precision, and efficiency of hearing health care services. Also, we raise awareness of risks that must be addressed to enable a safe digital transformation in audiology. We envision a future where computational audiology is implemented via interoperable systems using shared data and where health care providers adopt expanded roles within a network of distributed expertise. This effort should take place in a health care system where privacy, responsibility of each stakeholder, and patients' safety and autonomy are all guarded by design.


Asunto(s)
Audiología , Pérdida Auditiva , Inteligencia Artificial , Atención a la Salud , Audición , Humanos
10.
Ear Hear ; 42(4): 949-960, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33480623

RESUMEN

OBJECTIVES: The primary objective of this study is to identify the biographic, audiologic, and electrode position factors that influence speech perception performance in adult cochlear implant (CI) recipients implanted with a device from a single manufacturer. The secondary objective is to investigate the independent association of the type of electrode (precurved or straight) with speech perception. DESIGN: In a cross-sectional study design, speech perception measures and ultrahigh-resolution computed tomography scans were performed in 129 experienced CI recipients with a postlingual onset of hearing loss. Data were collected between December 2016 and January 2018 in the Radboud University Medical Center, Nijmegen, the Netherlands. The participants received either a precurved electrode (N = 85) or a straight electrode (N = 44), all from the same manufacturer. The biographic variables evaluated were age at implantation, level of education, and years of hearing loss. The audiometric factors explored were preoperative and postoperative pure-tone average residual hearing and preoperative speech perception score. The electrode position factors analyzed, as measured from images obtained with the ultrahigh-resolution computed tomography scan, were the scalar location, angular insertion depth of the basal and apical electrode contacts, and the wrapping factor (i.e., electrode-to-modiolus distance), as well as the type of electrode used. These 11 variables were tested for their effect on three speech perception outcomes: consonant-vowel-consonant words in quiet tests at 50 dB SPL (CVC50) and 65 dB SPL (CVC65), and the digits-in-noise test. RESULTS: A lower age at implantation was correlated with a higher CVC50 phoneme score in the straight electrode group. Other biographic variables did not correlate with speech perception. Furthermore, participants implanted with a precurved electrode and who had poor preoperative hearing thresholds performed better in all speech perception outcomes than the participants implanted with a straight electrode and relatively better preoperative hearing thresholds. After correcting for biographic factors, audiometric variables, and scalar location, we showed that the precurved electrode led to an 11.8 percentage points (95% confidence interval: 1.4-20.4%; p = 0.03) higher perception score for the CVC50 phonemes compared with the straight electrode. Furthermore, contrary to our initial expectations, the preservation of residual hearing with the straight electrode was poor, as the median preoperative and the postoperative residual hearing thresholds for the straight electrode were 88 and 122 dB, respectively. CONCLUSIONS: Cochlear implantation with a precurved electrode results in a significantly higher speech perception outcome, independent of biographic factors, audiometric factors, and scalar location.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Estudios Transversales , Humanos , Resultado del Tratamiento
11.
Eur Arch Otorhinolaryngol ; 278(9): 3135-3154, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33245451

RESUMEN

PURPOSE: This scoping review examines the available evidence on the effect of unilateral cochlear implantation (CI) in adults with postlingual bilateral hearing loss on societal-related outcomes in terms of work, autonomy and participation. METHODS: Five databases were searched (Pubmed, Web of Science, Embase, PsycINFO and Cochrane Library). Publications were screened in three steps on inclusion criteria. Of the 4230 screened publications, 110 met the inclusion criteria and were assessed for data extraction regarding outcomes "work", "autonomy", "participation". Study characteristics and key findings are presented and narratively described. RESULTS: Twenty-seven publications were included and categorized into retrospective (n = 3), cross-sectional (n = 18) or prospective (n = 6) study designs. Measurement or identification of number of outcomes (no) were related to work (no = 20), participation (no = 9) and autonomy or independency (no = 10). Most studies indicated benefits of CI on these outcomes. However, some studies did not or indicated additional barriers for benefits. Eleven publications primarily aimed to study one or more of our primary outcomes. CONCLUSION: In this literature search, scientific databases are reviewed. The results indicate that there is a relatively small body of evidence regarding the effect of CI on the outcomes "work", "autonomy" and "participation". Even though there are some limitations of the current study including some overlap in outcome definitions, most included studies indicate a beneficial effect of CI on work, autonomy and participation. The lack of consensus in definitions and the small body of evidence indicates a need for additional prospective studies investigating the societal outcomes of CI in postlingually deafened adults.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Adulto , Estudios Transversales , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
12.
Otol Neurotol ; 42(2): e124-e129, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32941298

RESUMEN

OBJECTIVES: The aim of this study is to report on our preliminary experience with Transimpedance Matrix (TIM)-measurement for the detection of cochlear implant electrode tip foldovers compared with intraoperative imaging in patients implanted with the slim modiolar electrode (SME). STUDY DESIGN: Proof of concept study. SETTING: Tertiary university referral center. PATIENTS: Twenty five ears (in 22 patients) implanted consecutively with the SME. INTERVENTIONS: Following cochlear implantation, intraoperative TIM-measurement and fluoroscopy were performed. One week postoperatively, the electrode position was evaluated using Computed Tomography (CT)-imaging. MAIN OUTCOME MEASURES: Electrode array tip foldover. RESULTS: Electrode array tip foldover occurred in three of the 25 cochlear implantations performed (12%). In each case, the foldover was detected by both TIM and fluoroscopy, leading to reposition and correct intracochlear placement of the array. CONCLUSIONS: TIM-measurement is a promising method for the intraoperative detection of an electrode array tip foldover. The TIM-tool with intuitive heatmap display is easy to use, fast, and readily available to clinics using TIM-software in the operating theatre.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/cirugía , Electrodos Implantados , Humanos , Prueba de Estudio Conceptual
13.
Cochlear Implants Int ; 21(2): 110-116, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31648613

RESUMEN

Objectives: The aim of this study is to investigate short and long term residual hearing preservation (HP), corrected for the natural progress of hearing loss, in cochlear implant (CI) patients receiving a straight electrode array using a round window (RW) approach.Methods: A retrospective and cross-sectional analysis on patients who received a CI with a straight electrode using a RW approach (n = 60) was performed. Audiometric data were obtained at three time points, preoperatively, at first fitting, and one year or more postoperatively. The HP outcome was calculated according to the HP definition as reported by Skarzynski with a PTA of 250, 500, and 1000 Hz (PTA3) and a PTA of 250, 500, 1000, and 2000 Hz (PTA4).Results: The HP outcome at first fitting and at long term follow up fell into the partial HP category, 63.5% (PTA3) and 40.5% (PTA4), respectively according to the Skarzynski definition. A decline in pure-tone average (PTA) was found in the CI ear and in the contralateral ear over time (p < 0.05). Interaural differences remained relatively stable at all frequencies on the long term, except for the frequency 250 Hz (p < 0.05).Discussion: After the initial loss of residual hearing, the hearing thresholds of the CI ear remain relatively stable at long term follow up when corrected for the natural course of hearing loss, except at 250 Hz.Conclusion: CI candidates should be counseled on the risk of long term deterioration of the residual hearing in both the CI ear and the contralateral ear.


Asunto(s)
Umbral Auditivo , Implantación Coclear/métodos , Implantes Cocleares/psicología , Corrección de Deficiencia Auditiva/psicología , Pérdida Auditiva/psicología , Anciano , Audiometría de Tonos Puros , Corrección de Deficiencia Auditiva/instrumentación , Estudios Transversales , Femenino , Pérdida Auditiva/rehabilitación , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Periodo Preoperatorio , Estudios Retrospectivos , Ventana Redonda/cirugía , Factores de Tiempo , Resultado del Tratamiento
14.
Eur Arch Otorhinolaryngol ; 277(2): 343-350, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31650350

RESUMEN

PURPOSE: In cochlear implantation (CI), the two factors that are determined by the surgeon with a potential significant impact on the position of the electrode within the cochlea and the potential outcome, are the surgical technique and electrode type. The objective of this prospective study was to evaluate the position of the slim, perimodiolar electrode (SPE), and to study the influence of the SPE position on CI outcome. METHODS: Twenty-three consecutively implanted, adult SPE candidates were included in this prospective cohort study conducted between December 2016 and April 2019. Mean age at surgery was 59.5 years. Mean preoperative residual hearing was 92.2 dB. Intra-operative fluoroscopy and high-resolution computed tomography scans were performed to evaluate electrode position after insertion using a cochleostomy (CS) approach. Follow-up was 12 months after implantation; residual hearing (6-8 weeks) and speech perception (6-8 weeks and 12 months) were evaluated in relation to the intracochlear SPE position. RESULTS: In most patients in whom the SPE was positioned in the scala tympani residual hearing was preserved [mean absolute increase in PTA of 4.4 dB and 77.2% relative hearing preservation (RHP%)]. Translocation into the scala vestibuli occurred in 36% of the insertions, resulting in a mean absolute increase in PTA of 17.9 dB, and a RHP% of 19.2%. Participants with a translocation had poorer speech perception scores at 12-month follow-up. CONCLUSION: Given the incidence of CS-associated translocations with the SPE and the negative effect on outcome, it is advised to insert the SPE using the (extended) round window approach.


Asunto(s)
Cóclea/cirugía , Implantación Coclear/métodos , Implantes Cocleares , Pérdida Auditiva/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Cóclea/diagnóstico por imagen , Implantación Coclear/efectos adversos , Implantes Cocleares/efectos adversos , Tomografía Computarizada de Haz Cónico , Femenino , Fluoroscopía , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/diagnóstico por imagen , Pruebas Auditivas , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis/etiología , Ventana Redonda/cirugía , Rampa Timpánica/cirugía
15.
Otol Neurotol ; 40(7): 900-910, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31135680

RESUMEN

OBJECTIVE: By discussing the design, findings, strengths, and weaknesses of available studies investigating the influence of angular insertion depth on speech perception, we intend to summarize the current status of evidence; and using evidence based conclusions, possibly contribute to the determination of the optimal cochlear implant (CI) electrode position. DATA SOURCES: Our search strategy yielded 10,877 papers. PubMed, Ovid EMBASE, Web of Science, and the Cochrane Library were searched up to June 1, 2018. Both keywords and free-text terms, related to patient population, predictive factor, and outcome measurements were used. There were no restrictions in languages or year of publication. STUDY SELECTION: Seven articles were included in this systematic review. Articles eligible for inclusion: (a) investigated cochlear implantation of any CI system in adults with post-lingual onset of deafness and normal cochlear anatomy; (b) investigated the relationship between angular insertion depth and speech perception; (c) measured angular insertion depth on imaging; and (d) measured speech perception at, or beyond 1-year post-activation. DATA EXTRACTION AND SYNTHESIS: In included studies; quality was judged low-to-moderate and risk of bias, evaluated using a Quality-in-Prognostic-Studies-tool (QUIPS), was high. Included studies were too heterogeneous to perform meta-analyses, therefore, effect estimates of the individual studies are presented. Six out of seven included studies found no effect of angular insertion depth on speech perception. CONCLUSION: All included studies are characterized by methodological flaws, and therefore, evidence-based conclusions regarding the influence of angular insertion depth cannot be drawn to date.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Sordera/cirugía , Percepción del Habla/fisiología , Adulto , Cóclea/cirugía , Humanos , Resultado del Tratamiento
16.
Front Neurosci ; 13: 54, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30842721

RESUMEN

Objective: The primary aim of this study was to longitudinally compare the behavioral and self-reported outcomes of simultaneous bilateral cochlear implantation (simBiCI) and sequential BiCI (seqBiCI) in adults with severe-to-profound postlingual sensorineural hearing loss. Design: This study is a multicenter randomized controlled trial with a 4-year follow-up period after the first moment of implantation. Participants were allocated by randomization to receive bilateral cochlear implants (CIs) either, simultaneously (simBiCI group) or sequentially with an inter-implant interval of 2 years (UCI/seqBiCI group). All sequential patients where encouraged to use their hearing aid on the non-implanted ear over of the first 2 years. Patients were followed-up on an annual basis. The primary outcome was speech perception in noise coming from a source directly in front of the patient. Other behavioral outcome measures were speech intelligibility-in-noise from spatially separated sources, localization and speech perception in quiet. Self-reported outcome measures encompassed questionnaires on quality of life, quality of hearing and tinnitus. All outcome measures were analyzed longitudinally using a linear or logistic regression analysis with an autoregressive residual covariance matrix (generalized estimating equations type). Results: Nineteen participants were randomly allocated to the simBiCI group and 19 participants to the UCI/seqBiCI group. Three participants in the UCI/seqBiCI group did not proceed with their second implantation and were therefore unavailable for follow-up. Both study groups performed equally well on speech perception in noise from a source directly in front of the patient longitudinally. During all 4 years of follow-up the UCI/seqBiCI group performed significantly worse compared to the simBiCI group on spatial speech perception in noise in the best performance situation (8.70 dB [3.96 - 13.44], p < 0.001) and localization abilities (largest difference 60 degrees configuration: -44.45% [-52.15 - -36.74], p < 0.0001). Furthermore, during all years of follow-up, the UCI/seqBiCI group performed significantly worse on quality of hearing and quality of life questionnaires. The years of unilateral CI use were the reason for the inferior results in the UCI/SeqBiCI group. One year after receiving CI2, the UCI/seqBiCI group performance did not statistically differ from the performance of the simBiCI group on all these outcomes. Furthermore, no longitudinal differences were seen in tinnitus burden prevalence between groups. Finally, the complications that occurred during this trial were infection, dysfunction of CI, facial nerve palsy, tinnitus and vertigo. Conclusion: This randomized controlled trial on bilaterally severely hearing impaired participants found a significantly worse longitudinal performance of UCI/seqBiCI compared to simBiCI on multiple behavioral and self-reported outcomes regarding speech perception in noise and localization abilities. This difference is associated with the inferior performance of the UCI/seqBiCI participants during the years of unilateral CI use. After receiving the second CI however, the performance of the UCI/seqBiCI group did not significantly differ from the simBiCI group. Trial Registration: Dutch Trial Register NTR1722.

17.
Eur Arch Otorhinolaryngol ; 276(5): 1313-1320, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30810818

RESUMEN

OBJECTIVES: To report on a retrospective cohort study on the effects of expanding inclusion criteria for application of cochlear implants (CIs) on the performance 1-year post-implantation. METHODS: Based on pre-implantation audiometric thresholds and aided speech recognition scores, the data of 164 CI recipients were divided into a group of patients that fulfilled conservative criteria (mean hearing loss at 0.5, 1 and 2 kHz > 85 dB HL and phoneme scores with hearing aids < 30%), and the remaining group of patients that felt outside this conservative criterion. Speech recognition scores (in quiet) and quality of life (using the NCIQ) of both groups, measured at 1-year post-implantation, were compared. RESULTS: The group that felt outside the conservative criterion showed a higher phoneme score at 1-year post-implantation compared to the conservative group, suggesting that relaxed criteria have a positive influence on the speech recognition results with CI. With respect to quality of life, both groups significantly improved 1-year post-implantation. The conservative group showed a higher benefit on the advanced perception domain of the NCIQ. Based on their worse pre-implantation hearing, this was expected. CONCLUSIONS: The data suggest that relaxation of CI indication positively affects the speech recognition performance of patients with severe hearing loss. Both groups of patients showed a positive effect of CI on the quality of life. This benefit relates to communication skills and the subjective day-to-day functioning in society.


Asunto(s)
Implantación Coclear/normas , Implantes Cocleares , Pérdida Auditiva Bilateral/cirugía , Pérdida Auditiva Sensorineural/cirugía , Anciano , Audiometría , Umbral Auditivo , Femenino , Audífonos , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Estudios Retrospectivos , Percepción del Habla
18.
Front Surg ; 4: 65, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29167796

RESUMEN

IMPORTANCE: There is an ongoing global discussion on whether or not bilateral cochlear implantation should be standard care for bilateral deafness. Contrary to unilateral cochlear implantation, however, little is known about the effect of bilateral cochlear implantation on tinnitus. OBJECTIVE: To investigate tinnitus outcomes 1 year after bilateral cochlear implantation. Secondarily, to compare tinnitus outcomes between simultaneous and sequential bilateral cochlear implantation and to investigate long-term follow-up (3 years). STUDY DESIGN: This study is a secondary analysis as part of a multicenter randomized controlled trial. METHODS: Thirty-eight postlingually deafened adults were included in the original trial, in which the presence of tinnitus was not an inclusion criterion. All participants received cochlear implants (CIs) because of profound hearing loss. Nineteen participants received bilateral CIs simultaneously and 19 participants received bilateral CIs sequentially with an inter-implant interval of 2 years. The prevalence and severity of tinnitus before and after simultaneous and sequential bilateral cochlear implantation were measured preoperatively and each year after implantation with the Tinnitus Handicap Inventory (THI) and Tinnitus Questionnaire (TQ). RESULTS: The prevalence of preoperative tinnitus was 42% (16/38). One year after bilateral implantation, there was a median difference of -8 (inter-quartile range (IQR): -28 to 4) in THI score and -9 (IQR: -17 to -9) in TQ score in the participants with preoperative tinnitus. Induction of tinnitus occurred in five participants, all in the simultaneous group, in the year after bilateral implantation. Although the preoperative and also the postoperative median THI and TQ scores were higher in the simultaneous group, the median difference scores were equal in both groups. In the simultaneous group, tinnitus scores fluctuated in the 3 years after implantation. In the sequential group, four patients had an additional benefit of the second CI: a total suppression of tinnitus compared with their unilateral situation. CONCLUSION: While bilateral cochlear implantation can have a positive effect on preoperative tinnitus complaints, the induction of (temporary or permanent) tinnitus was also reported. CLINICAL TRIAL REGISTRATION: Dutch Trial Register NTR1722.

19.
JAMA Otolaryngol Head Neck Surg ; 143(9): 881-890, 2017 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-28655036

RESUMEN

Importance: To date, no randomized clinical trial on the comparison between simultaneous and sequential bilateral cochlear implants (BiCIs) has been performed. Objective: To investigate the hearing capabilities and the self-reported benefits of simultaneous BiCIs compared with those of sequential BiCIs. Design, Setting, and Participants: A multicenter randomized clinical trial was conducted between January 12, 2010, and September 2, 2012, at 5 tertiary referral centers among 40 participants eligible for BiCIs. Main inclusion criteria were postlingual severe to profound hearing loss, age 18 to 70 years, and a maximum duration of 10 years without hearing aid use in both ears. Data analysis was conducted from May 24 to June 12, 2016. Interventions: The simultaneous BiCI group received 2 cochlear implants during 1 surgical procedure. The sequential BiCI group received 2 cochlear implants with an interval of 2 years between implants. Main Outcomes and Measures: First, the results 1 year after receiving simultaneous BiCIs were compared with the results 1 year after receiving sequential BiCIs. Second, the results of 3 years of follow-up for both groups were compared separately. The primary outcome measure was speech intelligibility in noise from straight ahead. Secondary outcome measures were speech intelligibility in noise from spatially separated sources, speech intelligibility in silence, localization capabilities, and self-reported benefits assessed with various hearing and quality of life questionnaires. Results: Nineteen participants were randomized to receive simultaneous BiCIs (11 women and 8 men; median age, 52 years [interquartile range, 36-63 years]), and another 19 participants were randomized to undergo sequential BiCIs (8 women and 11 men; median age, 54 years [interquartile range, 43-64 years]). Three patients did not receive a second cochlear implant and were unavailable for follow-up. Comparable results were found 1 year after simultaneous or sequential BiCIs for speech intelligibility in noise from straight ahead (difference, 0.9 dB [95% CI, -3.1 to 4.4 dB]) and all secondary outcome measures except for localization with a 30° angle between loudspeakers (difference, -10% [95% CI, -20.1% to 0.0%]). In the sequential BiCI group, all participants performed significantly better after the BiCIs on speech intelligibility in noise from spatially separated sources and on all localization tests, which was consistent with most of the participants' self-reported hearing capabilities. Speech intelligibility-in-noise results improved in the simultaneous BiCI group up to 3 years following the BiCIs. Conclusions and Relevance: This study shows comparable objective and subjective hearing results 1 year after receiving simultaneous BiCIs and sequential BiCIs with an interval of 2 years between implants. It also shows a significant benefit of sequential BiCIs over a unilateral cochlear implant. Until 3 years after receiving simultaneous BiCIs, speech intelligibility in noise significantly improved compared with previous years. Trial Registration: trialregister.nl Identifier: NTR1722.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Localización de Sonidos , Inteligibilidad del Habla , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
20.
Otol Neurotol ; 38(6): e120-e127, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28498263

RESUMEN

OBJECTIVES: Usher syndrome type IIa (USH2a) is characterized by congenital moderate to severe hearing impairment and retinitis pigmentosa. Hearing rehabilitation starts in early childhood with the application of hearing aids. In some patients with USH2a, severe progression of hearing impairment leads to insufficient speech intelligibility with hearing aids and issues with adequate communication and safety. Cochlear implantation (CI) is the next step in rehabilitation of such patients. This study evaluates the performance and benefit of CI in patients with USH2a. DESIGN: Retrospective case-control study to evaluate the performance and benefit of CI in 16 postlingually deaf adults (eight patients with USH2a and eight matched controls). Performance and benefit were evaluated by a speech intelligibility test and three quality-of-life questionnaires. RESULTS: Patients with USH2a with a mean age of 59 years at implantation exhibited good performance after CI. The phoneme scores improved significantly from 41 to 87% in patients with USH2a (p = 0.02) and from 30 to 86% in the control group (p = 0.001). The results of the questionnaire survey demonstrated a clear benefit from CI. There were no differences in performance or benefit between patients with USH2a and control patients before and after CI. CONCLUSIONS: CI increases speech intelligibility and improves quality of life in patients with USH2a.


Asunto(s)
Implantación Coclear/métodos , Calidad de Vida , Inteligibilidad del Habla , Síndromes de Usher/rehabilitación , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Percepción del Habla , Encuestas y Cuestionarios , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA