Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
ESC Heart Fail ; 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39239887

RESUMEN

Formal assessment of myocardial viability (MV) is challenging in acute myocardial infarction-related cardiogenic shock (AMI-CS) patients receiving Impella mechanical circulatory support, as the cardiac magnetic resonance gold standard technique is not feasible due to the metallic components of the device. 18-fluorodesoxyglucose metabolic myocardial positron emission tomography (18FDG-PET) may represent a valid and feasible alternative to obtain semi-quantitative and objective evidence of MV during Impella support. We hereby report the first series of sequential AMI-CS patients who received 18FDG-PET scanning to assess MV during Impella support to demonstrate the safety and feasibility of this approach. In this cohort no adverse events occurred during 18FDG-PET scans, and all images were of excellent quality. This study provides a pragmatic guidance on how to perform this imaging modality during Impella support and finally confirms the safety and feasibility of this advanced imaging method also in this vulnerable cohort of patients.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39190816

RESUMEN

AIMS: The prevalence, the etiologies and the clinical features of tricuspid regurgitation (TR) in the context of concomitant degenerative mitral valve (MV) disease are poorly defined. This paper aims to assess the prevalence, determinants and clinical consequences of TR in severe degenerative mitral regurgitation (DMR). METHODS AND RESULTS: Clinical and echocardiographic characteristics were collected among patients with severe DMR. 884 patients were included in our study, 31% with > moderate TR. Tricuspid valve prolapse (TVP) was the most common etiology (487 patients, 55%), followed by atrial functional TR (AFTR, 172 patients, 19%) and ventricular functional TR (VFTR, 42 patients, 5%), while TR etiology was mixed in 183 (21%) patients. Patients with TVP were younger, had better clinical presentation, had few comorbidities, and had less hemodynamically relevant TR. VFTR patients were characterized by older age, worst clinical presentation and both highest comorbidity rate and prevalence of >mild TR. AFTR group showed an intermediate profile of clinical presentation and comorbidities and the largest tricuspid annulus (TA) diameter.MV surgery was performed in 785 (88%) patients; 132 (15%) underwent simultaneous TV intervention, more often AFTR patients (32%). TA dilatation (OR 3.68, CI 2.05-6.62, p <0.001) and >mild TR (OR 9.30, CI 5.10-16.95, p<0.001) were independently associated with TV intervention. CONCLUSIONS: In patients with severe DMR, TR presents with different etiologies, clinical features and echocardiographic phenotypes that require a comprehensive assessment at the time of DMR surgery to ensure the best management for these patients.

3.
Heliyon ; 10(14): e34874, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39148991

RESUMEN

Background: We aimed to assess the characteristics, management and long-term prognosis of a cohort of patients with multiple valvular disease, focusing on the context of severe mitral or aortic disease with concomitant significant tricuspid regurgitation (TR). Methods: After using a propensity score matching for age, 975 patients with ≥ moderate TR, diagnosed at our centers from 2012 to 2020, were included and divided in four groups, including isolated TR patients as reference group. Primary endpoint was all-cause death (ACD), secondary endpoint was the composite of heart failure (HF) hospitalization + any valvular intervention. Results: Patients with isolated TR (356, 37 %) had more history of atrial fibrillation and were more often asymptomatic and with preserved left-ventricular ejection fraction (LVEF). Patients with severe mitral regurgitation (MR) + TR (466, 48 %) showed higher rates of concomitant coronary artery disease, advanced functional class symptoms and larger left atrial volumes. Severe aortic stenosis (AS) patients (131, 13 %) were older, with more comorbidities and lower LVEF. Patients with severe aortic regurgitation and TR (22, 2 %) were younger, with larger LV dimensions and higher pulmonary arterial pressures.After a median follow-up of 2.8 years, both endpoints were univariably more frequent in patients with severe AS + TR (all p < 0.001), but after comprehensive adjustment difference in the primary endpoint became insignificant, underscoring the serious outcomes of all significant TR groups significantly. Overall, in 44 (5 %) patients tricuspid intervention was performed, with no differences between groups in term of frequency of concomitant or staged tricuspid valve surgical treatment. Conclusions: In the context of severe left-sided VD, concomitant significant TR is common, and each subtype presents with different clinical and echocardiographic features: patients with severe AS and TR have considerable worse prognosis, although comprehensive adjustment reflected the poor outcomes affecting all types of patients with significant TR. In this scenario, TR was profoundly undertreated.

4.
J Am Heart Assoc ; 13(14): e033125, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38979804

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is frequent in patients with aortic stenosis (AS). Although primary MR is an established negative prognostic factor, whether different mechanisms of MR have different effects on outcome is currently unknown. The aim of this study was to evaluate the impact of the MR mechanism in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a retrospective observational study of patients who underwent TAVR for severe aortic stenosis in a high-volume tertiary care center. Echocardiographic comprehensive MR assessment was performed at baseline and within 3 months post TAVR. The study population was divided into 4 groups according to MR mechanism: Group I: fibro-calcific leaflet degeneration; Group II: prolapse/flail; Group III: ventricular secondary MR (functional MR); and Group IV: atrial functional MR. The study end point was a combination of death from cardiovascular cause and heart failure-related hospitalization. The study population included 427 patients (mean age 81.7±6.5 years; 71% primary MR; 62% ≥moderate MR). At 3-year follow-up, survival free from the composite end point significantly differs according to MR mechanism: it was higher in group IV (atrial functional MR, 96.6%) compared with group I (80.4%, P=0.002) and group II patients (60.7%, P=0.001), and group III (84.8%, P=0.037); patients with MR due to leaflet prolapse showed poorer prognosis compared with patients with functional MR (group III, P=0.023 and group IV, P=0.001) and with group I (P=0.040). Overall, severe MR after TAVR identified patients with poorer prognosis and was significantly more frequent in group II (46.4%, P=0.001). CONCLUSIONS: In patients undergoing TAVR, preprocedural identification of MR mechanism and mechanism provides prognostic insights.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Ecocardiografía , Factores de Riesgo , Factores de Tiempo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología
7.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38522488

RESUMEN

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Ecocardiografía Tridimensional/métodos , Femenino , Masculino , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/fisiopatología , Persona de Mediana Edad , Anciano , Ecocardiografía Transesofágica/métodos , Ecocardiografía Doppler en Color/métodos , Reproducibilidad de los Resultados , Válvula Mitral/diagnóstico por imagen , Curva ROC , Estudios Retrospectivos
9.
Int J Cardiol ; 389: 131188, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37453454

RESUMEN

BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Apéndice Atrial/cirugía , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
10.
J Arrhythm ; 39(3): 395-404, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37324751

RESUMEN

Background: The role of left atrial appendage occlusion (LAAO) for atrial fibrillation patients that during oral anticoagulant therapy (OAC) suffer from ischemic events or present LAA sludge, and the best postinterventional anticoagulant regimen, need to be defined. We present our experience with a hybrid approach of LAAO+ lifelong OAC therapy in this cohort of patients. Methods: Out of 425 patients treated with LAAO, 102 underwent LAAO because, despite OAC, suffered from ischemic events or presented with LAA sludge. Patients without high bleeding risk were discharged with the aim of maintaining lifelong OAC. This cohort was then matched to a population who underwent LAAO in primary ischemic events prevention. The primary endpoint was the composite of all-cause death and major adverse cardiovascular events consisting of ischemic stroke, systemic embolism (SE), and major bleeding. Results: Procedural success was 98%, and 70% of patients were discharged with anticoagulant therapy. After a median follow-up of 47.2 months, the primary endpoint occurred in 27 patients (26%). At multivariate analyses, coronary artery disease (OR 5.1, CI 1.89-14.27, p = .003) and OAC at discharge (OR 0.29, CI 0.11-0.80, p = .017) were associated with the primary endpoint. After propensity score matching, no significant difference was found in the survival free from the primary endpoint according to the indication for LAAO (p = .19). Conclusions: In this high-ischemic risk cohort, LAAO + OAC seem a long-term safe and effective therapeutical approach, with no difference in the survival free from the primary endpoint according to the indication for LAAO in a matched cohort.

11.
Echocardiography ; 40(8): 775-783, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37351556

RESUMEN

AIM: we sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. METHODS: This was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). RESULTS: Single measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean ± SE of the 16 labs was 19.7 ± .36 (95% CI: 18.8-20.4) in SR and 16.5 ± .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean ± SE was 43.8 ± .70 (95% CI: 42.3-45.3) and 10.2 ± .32 (95% CI: 9.5-10.9) respectively. CONCLUSION: While the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.


Asunto(s)
Fibrilación Atrial , Humanos , Reproducibilidad de los Resultados , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Sistema de Registros
12.
J Am Soc Echocardiogr ; 36(10): 1083-1091, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37307939

RESUMEN

BACKGROUND: Contrast-enhanced computed tomography is the reference-standard imaging technique to assess left atrial appendage (LAA) morphology. The aim of this study was to evaluate the accuracy and reliability of two-dimensional and new three-dimensional (3D) transesophageal echocardiographic rendering modalities in assessing LAA morphology. METHODS: Seventy consecutive patients who underwent both computed tomography and transesophageal echocardiography (TEE) were retrospectively enrolled. The traditional LAA morphology classification system (LAAcs; chicken wing, cauliflower, cactus, and windsock) and a new simplified LAAcs based on the LAA bend angle were used for the analysis. LAA morphology was independently assessed by two trained readers using three different modalities: two-dimensional TEE, 3D TEE with multiplanar reconstruction, and a new 3D transesophageal echocardiographic rendering modality with improved transparency (Glass). The new LAAcs and traditional LAAcs were compared in terms of intra- and interrater reliability. RESULTS: With the new LAAcs, two-dimensional TEE was fairly accurate in identifying LAA morphology (κ = 0.43, P < .05), with moderate interrater (κ = 0.50, P < .05) and substantial intrarater (κ = 0.65, P < .005) agreement. Three-dimensional TEE showed higher accuracy and reliability: 3D TEE with multiplanar reconstruction had almost perfect accuracy (κ = 0.85, P < .001) and substantial (κ = 0.79, P < .001) interrater reliability, while 3D TEE with Glass had substantial accuracy (κ = 0.70, P < .001) and almost perfect (κ = 0.84, P < .001) interrater reliability. Intrarater agreement was almost perfect for both 3D transesophageal echocardiographic modalities (κ = 0.85, P < .001). Accuracy was considerably lower when the traditional LAAcs was used, with 3D TEE with Glass being the most reliable technique (κ = 0.75, P < .05). The new LAAcs showed higher inter- and intrarater reliability compared with the traditional LAAcs (interrater, κ = 0.85 vs κ = 0.49; intrarater, κ = 0.94 vs κ = 0.68; P < .05). CONCLUSIONS: Three-dimensional TEE is an accurate, reliable, and feasible alternative to computed tomography in assessing LAA morphology with the new LAAcs. The new LAAcs shows higher reliability rates than the traditional one.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Ecocardiografía Transesofágica/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
13.
Front Cardiovasc Med ; 10: 1172005, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37383696

RESUMEN

Background: Percutaneous left atrial appendage occlusion (LAAO) presents many technical complex features, and it is often performed under the intraprocedural surveillance of a product specialist (PS). Our aim is to assess whether LAAO is equally safe and effective when performed in high-volume centers without PS support. Methods: Intraprocedural results and long-term outcome were retrospectively assessed in 247 patients who underwent LAAO without intraprocedural PS monitoring between January 2013 and January 2022 at three different hospitals. This cohort was then matched to a population who underwent LAAO with PS surveillance. The primary end point was all-cause mortality at 1 year. The secondary end point was a composite of cardiovascular mortality plus nonfatal ischemic stroke occurrence at 1 year. Results: Of the 247 study patients, procedural success was achieved in 243 patients (98.4%), with only 1 (0.4%) intraprocedural death. After matching, we did not identify any significant difference between the two groups in terms of procedural time (70 ± 19 min vs. 81 ± 30 min, p = 0.106), procedural success (98.4% vs. 96.7%, p = 0.242), and procedure-related ischemic stroke (0.8% vs. 1.2%, p = 0.653). Compared to the matched cohort, a significant higher dosage of contrast was used during procedures without specialist supervision (98 ± 19 vs. 43 ± 21, p < 0.001), but this was not associated with a higher postprocedural acute kidney injury occurrence (0.8% vs. 0.4%, p = 0.56). At 1 year, the primary and the secondary endpoints occurred in 21 (9%) and 11 (4%) of our cohort, respectively. Kaplan-Meier curves showed no significant difference in both primary (p = 0.85) and secondary (p = 0.74) endpoint occurrence according to intraprocedural PS monitoring. Conclusions: Our results show that LAAO, despite the absence of intraprocedural PS monitoring, remains a long-term safe and effective procedure, when performed in high-volume centers.

14.
Int J Cardiol ; 387: 131135, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37364718

RESUMEN

BACKGROUND: To evaluate the long-term clinical outcome of a cohort of patients suffering from moderate tricuspid regurgitation (TR), regardless of its etiology. METHODS: Clinical and echocardiographic follow-up were assessed in 250 patients diagnosed with moderate TR between January 2016 and July 2020. TR progression at follow-up was defined as TR grade increase to at least severe. The primary endpoint was all-cause death; secondary endpoints were cardiovascular (CV) death and the composite of heart failure (HF) hospitalization plus tricuspid valve (TV) intervention. RESULTS: After a median follow-up of 3.6 years, TR progression occurred in 84 patients (34%). At multivariate analyses, atrial fibrillation (AF, OR 1.81, CI 1.01-3.29, p = 0.045) and right ventricular end-diastolic diameter (RVEDD, OR 2.19, CI 1.26-3.78, p = 0.005) were independent predictors of TR progression. The primary endpoint occurred in 59 patients (24%) and was significantly more frequent in the group with TR progression (p = 0.009). At multivariate analyses, chronic kideney disease (OR 2.80, CI 1.30-6.03, p = 0.009), left ventricular ejection fraction (OR 0.97, CI 0.94-0.99, p = 0.041) and TR progression (OR 2.32, CI 1.31-4.12, p = 0.004) were independent predictors of the primary outcome. Moreover, both the secondary endpoints of CV death and HF hospitalization plus TV intervention were more frequent in the TR progression group (p = 0.001 and p < 0.001, respectively). CONCLUSIONS: Moderate TR progresses in a significant proportion of patients over a long-term follow-up, leading to a worse prognosis. TR progression is an independent determinant of hard clinical events and AF and RVEDD are associated with TR progression.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda , Estudios Retrospectivos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/complicaciones , Enfermedad Crónica , Progresión de la Enfermedad
15.
Int J Cardiol ; 384: 55-61, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37149007

RESUMEN

BACKGROUND: In terms of pathophysiology, tricuspid regurgitation (TR), right ventricular function and pulmonary artery pressure are linked to each other. Our aim was to analyze whether the echocardiography-derived right ventricular free wall longitudinal strain/pulmonary artery systolic pressures (RVFWLS/PASP) ratio can improve risk stratification in patients with severe tricuspid regurgitation (TR). METHODS: In this single-center retrospective study, 250 consecutive patients with severe TR were enrolled from December 2015 to December 2018. Baseline clinical and echocardiographic parameters were collected. Echocardiography-derived TAPSE/PASP and RVFWLS/PASP were evaluated. The primary endpoint was all-cause mortality. RESULTS: Out of 250 consecutive patients, 171 meet inclusion criteria. Patients were predominantly female, with several cardiovascular risk factors and comorbidities. RVFWLS/PASP ≤0.34%/mmHg (AUC 0.68, p < 0.001, sensitivity 70%, specificity 67%) was associated with baseline clinical RV heart failure (p = 0.03). After univariate and multivariate analyses, RVFWLS/PASP, but not TAPSE/PASP, independently correlated with all-cause mortality (HR 0.004, p = 0.02). Patients with RVFWLS/PASP >0.26%/mmHg (AUC 0.74, p < 0.001, sensitivity 77%, specificity 52%) showed higher survival rates (p = 0.02). In addition at 24 months follow-up, the Kaplan-Meyer curves showed patients with RVFWLS >14% & RVFWLS/PASP >0.26%/mmHg had the best survival rate compared to patients without. CONCLUSION: RVFWLS/PASP is independently associated with baseline RV heart failure and poor long-term prognosis in patients with severe TR.


Asunto(s)
Insuficiencia Cardíaca , Hipertensión Pulmonar , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Femenino , Masculino , Pronóstico , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Presión Sanguínea , Ecocardiografía Doppler , Estudios Retrospectivos , Función Ventricular Derecha/fisiología , Arteria Pulmonar/diagnóstico por imagen
16.
Eur Heart J Suppl ; 25(Suppl C): C189-C199, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125282

RESUMEN

Treatments for structural heart diseases (SHD) have been considerably evolved by the widespread of transcatheter approach in the last decades. The progression of transcatheter treatments for SHD was feasible due to the improvement of devices and the advances in imaging techniques. In this setting, the cardiovascular imaging is pivotal not only for the diagnosis but even for the treatment of SHD. With the aim of fulfilling these tasks, a multimodality imaging approach with new imaging tools for pre-procedural planning, intra-procedural guidance, and follow-up of SHD was developed. This review will describe the current state-of-the-art imaging techniques for the most common percutaneous interventions as well as the new imaging tools. The imaging approaches will be addressed describing the use in pre-procedural planning, intra-procedural guidance, and follow-up.

17.
Eur Heart J Cardiovasc Imaging ; 24(11): 1509-1517, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37194460

RESUMEN

AIMS: To evaluate the prognostic impact of pre-procedural right ventricular longitudinal strain (RVLS) in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge repair (TEER) in comparison with conventional echocardiographic parameters of RV function. METHODS AND RESULTS: This is a retrospective study including 142 patients with SMR undergoing TEER at two Italian centres. At 1-year follow-up 45 patients reached the composite endpoint of all-cause death or heart failure hospitalization. The best cut-off value of RV free-wall longitudinal strain (RVFWLS) to predict outcome was -18% [sensitivity 72%, specificity of 71%, area under curve (AUC) 0.78, P < 0.001], whereas the best cut-off value of RV global longitudinal strain (RVGLS) was -15% (sensitivity 56%, specificity 76%, AUC 0.69, P < 0.001). Prognostic performance was suboptimal for tricuspid annular plane systolic excursion, Doppler tissue imaging-derived tricuspid lateral annular systolic velocity and fractional area change (FAC). Cumulative survival free from events was lower in patients with RVFWLS ≥ -18% vs. RVFWLS < -18% (44.0% vs. 85.4%; < 0.001) as well as in patients with RVGLS ≥ -15% vs. RVGLS < -15% (54.9% vs. 81.7%; P < 0.001). At multivariable analysis FAC, RVGLS and RVFWLS were independent predictors of events. The identified cut-off of RVFWLS and RVGLS both resulted independently associated with outcomes. CONCLUSION: RVLS is a useful and reliable tool to identify patients with SMR undergoing TEER at high risk of mortality and HF hospitalization, on top of other clinical and echocardiographic parameters, with RVFWLS offering the best prognostic performance.


Asunto(s)
Insuficiencia de la Válvula Mitral , Disfunción Ventricular Derecha , Humanos , Pronóstico , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Valor Predictivo de las Pruebas
18.
Eur Heart J Cardiovasc Imaging ; 24(7): 887-896, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-36916015

RESUMEN

AIMS: Transcatheter aortic valve implantation (TAVI) is the treatment of choice for high-risk patients with severe aortic stenosis (AS). A portion of TAVI recipients has no long-term clinical benefit, and myocardial fibrosis may contribute to unfavourable outcomes. We aimed to assess the prognostic value of an interstitial fibrosis marker, extracellular volume fraction (ECV), measured at planning computed tomography (CT) before TAVI. METHODS AND RESULTS: From October 2020 to July 2021, 159 consecutive patients undergoing TAVI planning CT were prospectively enroled. ECV was calculated as the ratio of myocardium and blood pool differential attenuations before and 5 min after contrast administration, pondered for haematocrit. A composite endpoint including heart failure hospitalization (HFH) and death was collected by telehealth or in-person follow-up visits in the 113 patients constituting the final study population. Cox proportional hazards model was used to assess association between ECV and the composite endpoint.Median follow-up was 13 (11-15) months. The composite endpoint occurred in 23/113 (20%) patients. These patients had lower aortic valve mean pressure gradient [39 (29-48) vs. 46 (40-54) mmHg, P = 0.002] and left ventricular and right ventricular ejection fraction [51 (37-69) vs. 66 (54-74)%, P = 0.014; 45 (31-53) vs. 49 (44-55)%, P = 0.010] and higher ECV [31.5 (26.9-34.3) vs. 27.8 (25.3-30.2)%, P = 0.006]. At multivariable Cox analysis, ECV higher than 31.3% was associated to increased risk of death or HFH at follow-up (hazard ratio = 5.92, 95% confidence interval 2.37-14.75, P < 0.001). CONCLUSION: In this prospective observational cohort study, ECV measured at TAVI planning CT predicts the composite endpoint (HFH or death) in high-risk severe AS patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Función Ventricular Derecha , Pronóstico , Válvula Aórtica/cirugía , Fibrosis , Tomografía Computarizada por Rayos X , Tomografía , Función Ventricular Izquierda
19.
Eur Heart J Cardiovasc Imaging ; 24(8): 1043-1051, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-36797650

RESUMEN

AIMS: The procedural planning of transcatheter mitral valve replacement (TMVR) requires a specific imaging assessment to establish patient eligibility. Computed tomography (CT) is considered the reference method. In this setting, data regarding the role of transoesophageal echocardiography (TOE) are lacking. We evaluated the feasibility and reliability of a comprehensive 3D-TOE screening in TMVR candidates. METHODS AND RESULTS: We performed a retrospective observational study including 72 consecutive patients who underwent a pre-procedural CT and 3D-TOE for TMVR evaluation. The measurements of mitral annulus (MA), length of anterior mitral leaflet (AML), native left ventricular outflow tract (LVOT), and predicted neo-LVOT acquired with CT and 3D-TOE were compared using a novel semi-automated software for post processing analysis (3 mensio Structural Heart 10.1-3mSH, Pie Medical Imaging, Bilthoven, Netherlands). The final suitability decision was given by the valve manufacturer based on CT measurements and clinical conditions. Among 72 patients screened, all patients had adequate image quality for 3D-TOE analysis. 3D-TOE and CT measurements for AML length (r = 0.97), MA area (r = 0.90), perimeter (r = 0.68), anteroposterior (r = 0.88), and posteromedial-anterolateral (r = 0.74) diameters were found highly correlated, as well as for native LVOT (r = 0.86) and predicted neo-LVOT areas (r = 0.96) (all P-values <0.0001). An almost perfect agreement between CT and 3DTOE was found in assessing the eligibility for TMVR implantation (Cohen kappa 0.83, P < 0.001). CONCLUSION: 3D-TOE appraisements showed good correlations with CT measurements and high accuracy to predict TMVR screening success.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Leucemia Mieloide Aguda , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía Transesofágica , Reproducibilidad de los Resultados , Estudios de Factibilidad , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/cirugía
20.
J Heart Lung Transplant ; 42(4): 451-455, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36682892

RESUMEN

Intra-Aortic Balloon Pump (IABP) efficacy is critically affected by the inflation/deflation timing. Balloon deflation may cause a sucking effect, and a steal phenomenon on carotid flow. Delaying IABP deflation reduces the degree of this flow reversal, but at the same time exposes patients to the risk of increased proto-systolic afterload with detrimental effects on the LV. The purpose of this study was to investigate the effects of a delayed IABP deflation timing on cerebral blood flow and LV hemodynamics, by means of simultaneous carotid artery ultrasonography, trans-thoracic echocardiography and central aortic pressure analysis. Delaying IABP deflation trigger to the beginning of QRS effectively increased the cerebral blood flow by 20%, mostly by reducing the reverse component flow caused by the diastolic balloon deflation. Extending the deflation to the early systole was safe and favourably impacted on cardiac mechanics, increasing CO by 15% without prolonging LV isovolumetric contraction and ejection phases.


Asunto(s)
Arterias Carótidas , Circulación Cerebrovascular , Ventrículos Cardíacos , Contrapulsador Intraaórtico , Humanos , Ecocardiografía , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Corazón Auxiliar , Hemodinámica , Contrapulsador Intraaórtico/métodos , Factores de Tiempo , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/fisiopatología , Circulación Cerebrovascular/fisiología , Presión Arterial/fisiología , Ventrículos Cardíacos/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA