Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
J Med Case Rep ; 18(1): 74, 2024 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-38402220

RESUMEN

BACKGROUND: Most cases of traumatic injury during pregnancy involve blunt trauma, with penetrating trauma being uncommonly rare. In glass shard injuries, fragments often penetrate deeply, and multiple injuries may occur simultaneously; attention must be paid to the possibility of organ injury from the residual fragments. However, no case of this occurring during pregnancy has been reported yet. CASE PRESENTATION: We present the case of a 34-year-old pregnant Cameroonian woman who retained intraabdominal glass shards following a penetrating injury at 13 weeks gestation and not diagnosed until 22 weeks gestation. Notably, this patient continued the pregnancy without complications and gave birth via cesarean section at 36 weeks gestation. CONCLUSION: In pregnant women sustaining a penetrating glass trauma during pregnancy, careful attention should be paid to the fragments; in that case, computed tomography is a useful modality for accurately visualizing any remaining fragments in the body. Essentially, the foreign bodies in glass shard injuries during pregnancy should be removed immediately, but conservative management for term delivery is an important choice for patients at risk for preterm delivery.


Asunto(s)
Cuerpos Extraños , Heridas Penetrantes , Adulto , Femenino , Humanos , Embarazo , Cesárea , Cuerpos Extraños/complicaciones , Cuerpos Extraños/diagnóstico por imagen , Mujeres Embarazadas , Tomografía Computarizada por Rayos X
2.
J Acoust Soc Am ; 139(1): 512-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26827044

RESUMEN

In this study, the speed of sound (SOS) of two types of rat livers (eight normal livers, four cirrhotic livers) was measured with a scanning acoustic microscope using two transducers, one of which had an 80-MHz and the other a 250-MHz center frequency. The 250-MHz transducer had a better spatial resolution adapted to studying fiber or hepatic parenchymal cells. In normal livers, averages of the SOS values were from 1598 to 1677 m/s at 80-MHz and from 1568 to 1668 m/s at 250-MHz. In the fiber tissue of cirrhotic livers, averages of the SOS values were from 1645 to 1658 m/s at 80-MHz and from 1610 to 1695 m/s at 250-MHz, while the SOS values in the other tissue of cirrhotic livers ranged from 1644 to 1709 m/s at 80-MHz and from 1641 to 1715 m/s at 250-MHz. In one liver, SOS in fiber tissue was larger than that of tissues without fiber while in others it was lower. The resulting two-dimensional SOS maps provide a unique quantitative insight of liver acoustic microstructures in a healthy liver and in a cirrhotic ones. This study would be helpful to understand the complex relationship between acoustic properties and liver disease including fiber tissue.


Asunto(s)
Cirrosis Hepática/fisiopatología , Hígado/fisiopatología , Sonido , Animales , Diseño de Equipo , Hígado/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Masculino , Microscopía Acústica/instrumentación , Microscopía Acústica/métodos , Ratas , Espectrografía del Sonido
3.
Adv Mater ; 23(46): 5498-501, 2011 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-22081506

RESUMEN

Continuous tuning of lasing wavelength is achieved in cholesteric liquid crystal lasers by embedding a network of nanopores with an average size of 10 nm filled with liquid crystals inside a polymerized matrix with helical order. The device possesses both high transparency and a fast response time because the tuning is driven by local reorientation of the liquid crystal molecules in the nanopores.


Asunto(s)
Rayos Láser , Cristales Líquidos/química , Nanoporos , Electricidad , Análisis Espectral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA