Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
J Am Heart Assoc ; 13(19): e035599, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39344639

RESUMEN

BACKGROUND: The acquisition of contrast-enhanced T1 maps to calculate extracellular volume (ECV) requires contrast agent administration and is time consuming. This study investigates generative adversarial networks for contrast-free, virtual extracellular volume (vECV) by generating virtual contrast-enhanced T1 maps. METHODS AND RESULTS: This retrospective study includes 2518 registered native and contrast-enhanced T1 maps from 1000 patients who underwent cardiovascular magnetic resonance at 1.5 Tesla. Recent hematocrit values of 123 patients (hold-out test) and 96 patients from a different institution (external evaluation) allowed for calculation of conventional ECV. A generative adversarial network was trained to generate virtual contrast-enhanced T1 maps from native T1 maps for vECV creation. Mean and SD of the difference per patient (ΔECV) were calculated and compared by permutation of the 2-sided t test with 10 000 resamples. For ECV and vECV, differences in area under the receiver operating characteristic curve (AUC) for discriminating hold-out test patients with normal cardiovascular magnetic resonance versus myocarditis or amyloidosis were tested with Delong's test. ECV and vECV showed a high agreement in patients with myocarditis (ΔECV: hold-out test, 2.0%±1.5%; external evaluation, 1.9%±1.7%) and normal cardiovascular magnetic resonance (ΔECV: hold-out test, 1.9%±1.4%; external evaluation, 1.5%±1.2%), but variations in amyloidosis were higher (ΔECV: hold-out test, 6.2%±6.0%; external evaluation, 15.5%±6.4%). In the hold-out test, ECV and vECV had a comparable AUC for the diagnosis of myocarditis (ECV AUC, 0.77 versus vECV AUC, 0.76; P=0.76) and amyloidosis (ECV AUC, 0.99 versus vECV AUC, 0.96; P=0.52). CONCLUSIONS: Generation of vECV on the basis of native T1 maps is feasible. Multicenter training data are required to further enhance generalizability of vECV in amyloidosis.


Asunto(s)
Medios de Contraste , Aprendizaje Profundo , Miocarditis , Humanos , Estudios Retrospectivos , Masculino , Femenino , Persona de Mediana Edad , Miocarditis/diagnóstico por imagen , Miocarditis/patología , Adulto , Amiloidosis/diagnóstico por imagen , Amiloidosis/patología , Miocardio/patología , Imagen por Resonancia Cinemagnética/métodos , Interpretación de Imagen Asistida por Computador , Anciano , Valor Predictivo de las Pruebas
2.
Eur J Radiol ; 181: 111728, 2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39276400

RESUMEN

PURPOSE: To explore the potential differences in epicardial adipose tissue (EAT) volume and attenuation measurements between photon-counting detector (PCD) and energy-integrating detector (EID)-CT systems. METHODS: Fifty patients (mean age 69 ± 8 years, 41 male [82 %]) were prospectively enrolled for a research coronary CT angiography (CCTA) on a PCD-CT within 30 days after clinical EID-based CCTA. EID-CT acquisitions were reconstructed using a Bv40 kernel at 0.6 mm slice thickness. The PCD-CT acquisition was reconstructed at a down-sampled resolution (0.6 mm, Bv40; [PCD-DS]) and at ultra-high resolutions (PCD-UHR) with a 0.2 mm slice thickness and Bv40, Bv48, and Bv64 kernels. EAT segmentation was performed semi-automatically at about 1 cm intervals and interpolated to cover the whole epicardium within a threshold of -190 to -30 HU. A subgroup analysis was performed based on quartile groups created from EID-CT data and PCD-UHRBv48 data. Differences were measured using repeated-measures ANOVA and the Friedman test. Correlations were tested using Pearson's and Spearman's rho, and agreement using Bland-Altman plots. RESULTS: EAT volumes significantly differed between some reconstructions (e.g. EID-CT: 138 ml [IQR 100, 188]; PCD-DS: 147 ml [110, 206]; P<0.001). Overall, correlations between PCD-UHR and EID-CT EAT volumes were excellent, e.g. PCD-UHRBv48: r: 0.976 (95 % CI: 0.958, 0.987); P<0.001; with good agreement (mean bias: -9.5 ml; limits of agreement [LoA]: -40.6, 21.6). On the other hand, correlations regarding EAT attenuation was moderate, e.g. PCD-UHRBV48: r: 0.655 (95 % CI: 0.461, 0.790); P<0.001; mean bias: 6.5 HU; LoA: -2.0, 15.0. CONCLUSION: EAT attenuation and volume measurements demonstrated different absolute values between PCD-UHR, PCD-DS as well as EID-CT reconstructions, but showed similar tendencies on an intra-individual level. New protocols and threshold ranges need to be developed to allow comparison between PCD-CT and EID-CT data.

3.
J Cardiovasc Magn Reson ; : 101094, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39278415

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is an emerging imaging modality for assessing anatomy and function of the fetal heart in congenital heart disease (CHD). This study aimed to evaluate myocardial strain using fetal CMR feature tracking (FT) in different subtypes of CHD. METHODS: Fetal CMR FT analysis was retrospectively performed on four-chamber cine images acquired with Doppler US gating at 3 Tesla. Left ventricular (LV) global longitudinal strain (GLS), LV global radial strain (GRS), LV global longitudinal systolic strain rate (SR), and right ventricular (RV) GLS were quantified using a dedicated software optimized for fetal strain analysis. Analysis was performed in normal fetuses and different CHD subtypes (d-Transposition of the great arteries (dTGA), hypoplastic left heart syndrome (HLHS), coarctation of the aorta (CoA), tetralogy of Fallot (TOF), RV-dominant atrioventricular septal defect (AVSD), and critical pulmonary stenosis or atresia (PS/PA)). Analyses of variance (ANOVA) with Tukey post-hoc test was used for group comparisons. RESULTS: A total of 60 fetuses were analyzed (8/60 (13%) without CHD, 52/60 (87%) with CHD). Myocardial strain was successfully assessed in 113/120 ventricles (94%). Compared to controls, LV GLS was significantly reduced in fetuses with HLHS (-18.6±2.7% vs. -6.2±5.6%; p<0.001) and RV-dominant AVSD (-18.6±2.7% vs. -7.7±5.0%; p=0.003) and higher in fetuses with CoA (-18.6±2.7% vs. -25.0±4.3%; p=0.038). LV GRS was significantly reduced in fetuses with HLHS (25.7±7.5% vs. 11.4±9.7%; p=0.024). Compared to controls, RV GRS was significantly reduced in fetuses with PS/PA (-16.1±2.8% vs. -8.3±4.2%; p=0.007). Across all strain parameters, no significant differences were present between controls and fetuses diagnosed with dTGA and TOF. CONCLUSIONS: Fetal myocardial strain assessment with CMR FT in CHD is feasible. Distinct differences are present between various types of CHD, suggesting potential implications for clinical decision-making and prognostication in fetal CHD.

4.
Radiologie (Heidelb) ; 2024 Aug 13.
Artículo en Alemán | MEDLINE | ID: mdl-39138672

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA) has become a central tool for the primary diagnosis of stable coronary artery disease (CAD). Its integration into the service catalog of the German statutory health insurance will not only transform the way patients are examined and treated but also enhance the collaboration between nonradiologists and radiologists. OBJECTIVE: This article explores the requirements nonradiologists have for CCTA and identifies ways to promote successful interdisciplinary communication. MATERIALS AND METHODS: The study addresses criteria for proper patient selection and preparation for CCTA. It considers the perspectives and needs of patients and various medical specialties, highlighting essential aspects of interdisciplinary communication. RESULTS: CCTA enables precise clarification of CAD and should be used for patients with a pretest probability of chronic CAD between 15 and 50%. Clear action plans in the diagnostic report are crucial to assist general practitioners and cardiologists in treatment planning. Patients expect clear information about the procedure, possible risks, and results. CONCLUSION: Close collaboration between various medical disciplines is essential for the successful implementation of CCTA. Clear, structured diagnostic reports with annotated images, along with regular case discussions and feedback loops, can improve report interpretation and interdisciplinary communication. Patient-friendly reports can make diagnostic results more understandable and enhance patient adherence.

5.
Eur Heart J Cardiovasc Imaging ; 25(10): 1451-1461, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-38912832

RESUMEN

AIMS: To evaluate different cardiovascular magnetic resonance (CMR) parameters for the differentiation of light chain amyloidosis (AL) and transthyretin-related amyloidosis (ATTR). METHODS AND RESULTS: In total, 75 patients, 53 with cardiac amyloidosis {20 patients with AL [66 ± 12 years, 14 males (70%)] and 33 patients with ATTR [78 ± 5 years, 28 males (88%)]} were retrospectively analysed regarding CMR parameters such as T1 and T2 mapping, extracellular volume (ECV), late gadolinium enhancement (LGE) distribution patterns, and myocardial strain, and compared to a control cohort with other causes of left ventricular hypertrophy {LVH; 22 patients [53 ± 16 years, 17 males (85%)]}. One-way ANOVA and receiver operating characteristic analysis were used for statistical analysis. ECV was the single best parameter to differentiate between cardiac amyloidosis and controls [area under the curve (AUC): 0.97, 95% confidence intervals (CI): 0.89-0.99, P < 0.0001, cut-off: >30%]. T2 mapping was the best single parameter to differentiate between AL and ATTR amyloidosis (AL: 63 ± 4 ms, ATTR: 58 ± 2 ms, P < 0.001, AUC: 0.86, 95% CI: 0.74-0.94, cut-off: >61 ms). Subendocardial LGE was predominantly observed in AL patients (10/20 [50%] vs. 5/33 [15%]; P = 0.002). Transmural LGE was predominantly observed in ATTR patients (23/33 [70%] vs. 2/20 [10%]; P < 0.001). The diagnostic performance of T2 mapping to differentiate between AL and ATTR amyloidosis was further increased with the inclusion of LGE patterns [AUC: 0.96, 95% CI: (0.86-0.99); P = 0.05]. CONCLUSION: ECV differentiates cardiac amyloidosis from other causes of LVH. T2 mapping combined with LGE differentiates AL from ATTR amyloidosis with high accuracy on a patient level.


Asunto(s)
Neuropatías Amiloides Familiares , Imagen por Resonancia Cinemagnética , Humanos , Masculino , Femenino , Estudios Retrospectivos , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/complicaciones , Anciano , Diagnóstico Diferencial , Persona de Mediana Edad , Imagen por Resonancia Cinemagnética/métodos , Cardiomiopatías/diagnóstico por imagen , Amiloidosis/diagnóstico por imagen , Estudios de Casos y Controles , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/complicaciones , Anciano de 80 o más Años , Curva ROC , Análisis de Varianza , Estudios de Cohortes , Medios de Contraste
6.
Radiol Cardiothorac Imaging ; 6(2): e230182, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38602469

RESUMEN

Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Imagen por Resonancia Magnética , Atención Prenatal , Femenino , Embarazo , Humanos , Radiografía , Corazón Fetal/diagnóstico por imagen , Tecnología
7.
J Cardiovasc Magn Reson ; 26(1): 101035, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38460841

RESUMEN

BACKGROUND: Patients are increasingly using Generative Pre-trained Transformer 4 (GPT-4) to better understand their own radiology findings. PURPOSE: To evaluate the performance of GPT-4 in transforming cardiovascular magnetic resonance (CMR) reports into text that is comprehensible to medical laypersons. METHODS: ChatGPT with GPT-4 architecture was used to generate three different explained versions of 20 various CMR reports (n = 60) using the same prompt: "Explain the radiology report in a language understandable to a medical layperson". Two cardiovascular radiologists evaluated understandability, factual correctness, completeness of relevant findings, and lack of potential harm, while 13 medical laypersons evaluated the understandability of the original and the GPT-4 reports on a Likert scale (1 "strongly disagree", 5 "strongly agree"). Readability was measured using the Automated Readability Index (ARI). Linear mixed-effects models (values given as median [interquartile range]) and intraclass correlation coefficient (ICC) were used for statistical analysis. RESULTS: GPT-4 reports were generated on average in 52 s ± 13. GPT-4 reports achieved a lower ARI score (10 [9-12] vs 5 [4-6]; p < 0.001) and were subjectively easier to understand for laypersons than original reports (1 [1] vs 4 [4,5]; p < 0.001). Eighteen out of 20 (90%) standard CMR reports and 2/60 (3%) GPT-generated reports had an ARI score corresponding to the 8th grade level or higher. Radiologists' ratings of the GPT-4 reports reached high levels for correctness (5 [4, 5]), completeness (5 [5]), and lack of potential harm (5 [5]); with "strong agreement" for factual correctness in 94% (113/120) and completeness of relevant findings in 81% (97/120) of reports. Test-retest agreement for layperson understandability ratings between the three simplified reports generated from the same original report was substantial (ICC: 0.62; p < 0.001). Interrater agreement between radiologists was almost perfect for lack of potential harm (ICC: 0.93, p < 0.001) and moderate to substantial for completeness (ICC: 0.76, p < 0.001) and factual correctness (ICC: 0.55, p < 0.001). CONCLUSION: GPT-4 can reliably transform complex CMR reports into more understandable, layperson-friendly language while largely maintaining factual correctness and completeness, and can thus help convey patient-relevant radiology information in an easy-to-understand manner.


Asunto(s)
Comprensión , Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Variaciones Dependientes del Observador , Alfabetización en Salud , Educación del Paciente como Asunto , Enfermedades Cardiovasculares/diagnóstico por imagen , Femenino , Masculino
8.
Epilepsia ; 65(5): 1462-1474, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38436479

RESUMEN

OBJECTIVE: Interictal blood-brain barrier dysfunction in chronic epilepsy has been demonstrated in animal models and pathological specimens. Ictal blood-brain barrier dysfunction has been shown in humans in vivo using an experimental quantitative magnetic resonance imaging (MRI) protocol. Here, we hypothesized that interictal blood-brain barrier dysfunction is also present in people with drug-resistant epilepsy. METHODS: Thirty-nine people (21 females, mean age at MRI ± SD = 30 ± 8 years) with drug-resistant epilepsy were prospectively recruited and underwent interictal T1-relaxometry before and after administration of a paramagnetic contrast agent. Likewise, quantitative T1 was acquired in 29 people without epilepsy (12 females, age at MRI = 48 ± 18 years). Quantitative T1 difference maps were calculated and served as a surrogate imaging marker for blood-brain barrier dysfunction. Values of quantitative T1 difference maps inside hemispheres ipsilateral to the presumed seizure onset zone were then compared, on a voxelwise level and within presumed seizure onset zones, to the contralateral side of people with epilepsy and to people without epilepsy. RESULTS: Compared to the contralateral side, ipsilateral T1 difference values were significantly higher in white matter (corrected p < .05), gray matter (uncorrected p < .05), and presumed seizure onset zones (p = .04) in people with epilepsy. Compared to people without epilepsy, significantly higher T1 difference values were found in the anatomical vicinity of presumed seizure onset zones (p = .004). A subgroup of people with hippocampal sclerosis demonstrated significantly higher T1 difference values in the ipsilateral hippocampus and in regions strongly interconnected with the hippocampus compared to people without epilepsy (corrected p < .01). Finally, z-scores reflecting the deviation of T1 difference values within the presumed seizure onset zone were associated with verbal memory performance (p = .02) in people with temporal lobe epilepsy. SIGNIFICANCE: Our results indicate a blood-brain barrier dysfunction in drug-resistant epilepsy that is detectable interictally in vivo, anatomically related to the presumed seizure onset zone, and associated with cognitive deficits.


Asunto(s)
Barrera Hematoencefálica , Epilepsia Refractaria , Imagen por Resonancia Magnética , Humanos , Barrera Hematoencefálica/fisiopatología , Barrera Hematoencefálica/patología , Barrera Hematoencefálica/diagnóstico por imagen , Femenino , Masculino , Adulto , Persona de Mediana Edad , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/diagnóstico por imagen , Adulto Joven , Estudios Prospectivos , Epilepsia/fisiopatología , Epilepsia/diagnóstico por imagen
9.
Front Radiol ; 4: 1346550, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38445105

RESUMEN

Purpose: Due to a lack of data, there is an ongoing debate regarding the optimal frontline interventional therapy for unresectable hepatocellular carcinoma (HCC). The aim of the study is to compare the results of transarterial radioembolization (TARE) as the first-line therapy and as a subsequent therapy following prior transarterial chemoembolization (TACE) in these patients. Methods: A total of 83 patients were evaluated, with 38 patients having undergone at least one TACE session prior to TARE [27 male; mean age 67.2 years; 68.4% stage Barcelona clinic liver cancer (BCLC) B, 31.6% BCLC C]; 45 patients underwent primary TARE (33 male; mean age 69.9 years; 40% BCLC B, 58% BCLC C). Clinical [age, gender, BCLC stage, activity in gigabecquerel (GBq), Child-Pugh status, portal vein thrombosis, tumor volume] and procedural [overall survival (OS), local tumor control (LTC), and progression-free survival (PFS)] data were compared. A regression analysis was performed to evaluate OS, LTC, and PFS. Results: No differences were found in OS (95% CI: 1.12, P = 0.289), LTC (95% CI: 0.003, P = 0.95), and PFS (95% CI: 0.4, P = 0.525). The regression analysis revealed a relationship between Child-Pugh score (P = 0.005), size of HCC lesions (>10 cm) (P = 0.022), and OS; neither prior TACE (Child-Pugh B patients; 95% CI: 0.120, P = 0.729) nor number of lesions (>10; 95% CI: 2.930, P = 0.087) correlated with OS. Conclusion: Prior TACE does not affect the outcome of TARE in unresectable HCC.

10.
Heliyon ; 10(6): e28142, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38533048

RESUMEN

Rationale and objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated. Additionally, readers had to assign the scans to reduced or regular CMD. Regions-of-interest (ROIs) were placed in defined segments of portal vein, inferior vena cava, liver, spleen, kidneys, abdominal aorta and muscular tissue. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Results: Overall 158 CT scans performed on a PCD-CT and 68 examinations on an EID-CT were analyzed. Overall diagnostic quality showed no significant differences for PCD-CT with standard CMD which scored a median 5 (IQR:5-5) and PCD-CT with 70% CMD scoring 5 (4-5). (For PCD-CT, 71.69% of the examinations with reduced CMD were assigned to regular CMD by the readers, for EID-CT 9.09%. Averaged for all measurements SNR for 50% CMD was reduced by 19% in PCD-CT (EID-CT 34%) and CNR by 48% (EID-CT 56%). Virtual monoenergetic images (VMI)50keV for PCD-CT images acquired with 50% CMD showed an increase in SNR by 72% and CNR by 153%. Conclusions: Diagnostic interpretability of PCD-CT examinations with reduction of up to 50% CMD is maintained. PCD-CT deducted scans especially with 70% CMD were often not recognized as CMD reduced scans. Compared to EID-CT less decline in SNR and CNR is observed for CMD reduced PCD-CT images. Employing VMI50keV for CMD-reduced PCD-CT images compensated for the effects.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA