RESUMEN
Background: Although mortality after acute coronary syndrome (ACS) has improved in the acute phase, cardiovascular events occur at a certain frequency in the chronic phase. A hospital lipid-lowering protocol (HLP) could be effective in providing optimal lipid-lowering therapy to improve long-term clinical outcomes after ACS. Aims: This study investigated the impact of HLP on clinical outcomes in patients with ACS. Methods: We retrospectively analysed 1,114 ACS patients who had undergone successful percutaneous coronary intervention between November 2011 and June 2021. In December 2018, we introduced a HLP that included the prescription of the maximum tolerated dose of statin, ezetimibe, and eicosapentaenoic acid after ACS treatment. We compared 2-year clinical outcomes before (control group: 791 patients) and after the HLP's introduction (HLP group: 323 patients). The primary outcome was the non-target vessel revascularisation (non-TVR) rate. A multivariate Cox proportional hazard model and inverse probability weighting (IPW) based on the propensity score were used to evaluate the effect of HLP on the outcomes. Results: The cumulative 2-year non-TVR incidence was significantly lower in the HLP group than in the control group (8.5% vs 13.8%; p=0.019). Multivariable analysis revealed non-TVR risk was significantly lower in the HLP group than in the control group (adjusted hazard ratio [aHR]: 0.637 [95% confidence interval [CI]: 0.416-0.975]; p=0.038). The IPW analysis confirmed a significant association between the HLP and a lower non-TVR risk (aHR: 0.544 [95% CI: 0.350-0.847]; p=0.007). Conclusions: Implementing HLP for ACS patients improved the 2-year clinical outcome.
RESUMEN
Background: Cilostazol has reported effectiveness for preventing aspiration pneumonia in patients with ischemic stroke, but whether it is similarly beneficial for patients with chronic limb-threatening ischemia (CLTI) is unclear. Methods and Results: This retrospective single-center study enrolled 1,368 CLTI patients treated with endovascular therapy (EVT). In the multivariate analysis, predictors for aspiration pneumonia were age (hazard ratio [HR] 1.06 [95% confidence interval (CI) 1.03-1.10]), non-ambulatory status (HR 2.54 [95% CI 1.38-4.65]), the Geriatric Nutritional Risk Index (HR 0.97 [95% CI 0.95-0.99]), and cilostazol (HR 0.37 [95% CI 0.16-0.87]). Conclusions: Cilostazol administration reduced the risk of aspiration pneumonia in patients with CLTI undergoing EVT.
RESUMEN
Background: Because the clinical benefit of antiplatelet therapy (APT) for patients with nonsignificant coronary artery disease (CAD) remains poorly understood, we evaluated it in patients after fractional flow reserve (FFR)-guided deferral of revascularization. Methods and Results: From the J-CONFIRM (Long-Term Outcomes of Japanese Patients with Deferral of Coronary Intervention Based on Fractional Flow Reserve in Multicenter Registry), we investigated 265 patients with deferred lesions who did not require APT for secondary prevention of cardiovascular disease. A 2-year landmark analysis assessed the relationship between APT at 2 years and 5-year major cardiac adverse events (MACE: composite of all-cause death, target vessel-related myocardial infarction, clinically driven target vessel revascularization). Of the 265 patients, 163 (61.5%) received APT. The 5-year MACE did not significantly differ between the APT and non-APT groups after adjustment for baseline clinical characteristics (9.2% vs. 6.9%, inverse probability weighted hazard ratio, 1.40 [95% confidence interval, 0.53-3.69]; P=0.49). There was a marginal interaction between the effect of APT on MACE and FFR values (< or ≥0.84) (P for interaction=0.066). Conclusions: The 5-year outcomes after FFR-guided deferral of revascularization did not significantly differ between the APT and non-APT groups, suggesting that APT might not be a critical requirement for nonsignificant obstructive CAD patients not requiring APT for secondary prevention of cardiovascular disease.
RESUMEN
An 83-year-old woman with claudication in the right lower extremity was referred to our hospital. Since angiography showed severe stenosis with a severely calcified lesion extending from the ostial to proximal part of the right superficial femoral artery (SFA), endovascular therapy (EVT) with the Jetstream™ atherectomy system (Boston Scientific, Marlborough, MA, USA) and paclitaxel-coated balloon (PCB) was performed. Atherectomy was performed using the Jetstream™ atherectomy catheter SC 1.85, followed by an additional atherectomy using the Jetstream™ atherectomy catheter XC 2.1/3.0. Subsequently, angiography and intravascular ultrasound (IVUS) images showed the enlargement of lumen area due to the reduction of calcified plaque, but even some of the healthy media on the side free of calcified plaque had been removed. Next, a PCB dilation was performed, and the final angiography showed adequate dilation. However, the symptoms recurred 9â¯months after EVT. Angiography revealed an enlarged vessel suggestive of pseudoaneurysm at the ostial part of the right SFA and severe stenosis distal to the enlarged vessel. IVUS images showed a pseudoaneurysm and severe stenosis due to calcified nodules distal to the pseudoaneurysm. This case suggests that pseudoaneurysm is a potential complication of EVT with the Jetstream™ atherectomy system and PCB for SFA lesions. Learning objective: The Jetstream™ atherectomy system (Boston Scientific, Marlborough, MA, USA) has developed to improve outcomes for femoropopliteal artery lesions with severely calcified lesions in lower extremity arterial disease by removing calcified plaque and improving vascular compliance. Several clinical reports demonstrated durable patency rates and low complication rates after endovascular therapy using the atherectomy device. However, pseudoaneurysm is a potential complication of endovascular therapy with the Jetstream™ atherectomy system.
RESUMEN
BACKGROUND: Coronary angioscopy (CAS) has 2 unique abilities: direct visualization of thrombi and plaque color. However, in the recent drug-eluting stent (DES) era, serial CAS findings after DES implantation have not been fully elucidated. We investigated the impact of CAS findings after implantation of a polymer-free biolimus A9-coated stent (PF-BCS) or durable polymer everolimus-eluting stent (DP-EES). METHODS AND RESULTS: We investigated serial CAS and optical coherence tomography (OCT) findings at 1 and 12 months in 99 patients who underwent PF-BCS or DP-EES implantation. We evaluated factors correlated with angioscopic thrombi and yellow plaque, and the clinical impact of both thrombi and yellow plaque at 12 months (BTY). The BTY group included 17 (22%) patients. The incidence and grade of thrombi and yellow plaque decreased from 1 to 12 months. Although no patients had newly appearing thrombi at 12 months, 2 DP-EES patients had newly appearing yellow plaque at 12 months. Multivariable analysis revealed HbA1c, minimum stent area, and adequate strut coverage were significant factors correlated with 12-month angioscopic thrombi, and DP-EESs were significantly correlated with 12-month yellow plaque. However, BTY was not correlated with clinical events. CONCLUSIONS: The management of diabetes, stent area, and adequate stent coverage are important for intrastent thrombogenicity and polymer-free stents are useful for stabilizing plaque vulnerability.
Asunto(s)
Angioscopía , Stents Liberadores de Fármacos , Everolimus , Placa Aterosclerótica , Tomografía de Coherencia Óptica , Humanos , Stents Liberadores de Fármacos/efectos adversos , Anciano , Masculino , Femenino , Persona de Mediana Edad , Angioscopía/métodos , Everolimus/administración & dosificación , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Trombosis Coronaria/etiología , Trombosis Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapiaRESUMEN
BACKGROUNDS: Lead dislodgement is a severe complication in cardiac implantable electronic device (CIED) implantation. Inflammation after CIED implantation results in the development of adhesions between lead and tissues, resulting in the lead becoming fixed in the body. In patients with immunosuppressive therapy, however, adhesion is inhibited by anti-inflammatory effects. However, the association between lead dislodgement and immunosuppressive therapy has not been clarified. The purpose of this study was to investigate the association between lead dislodgement and immunosuppressive therapy. HYPOTHESIS: We hypothesized that lead dislodgement more frequently occur in patients with immunosuppressive therapy than those without. METHODS: In total, 651 consecutive patients who underwent CIED implantation or lead addition (age, 76 ± 11 years; and males, 374 [58%], high voltage device, 121 [19%], lead addition 23 [4%]) were retrospectively enrolled. Immunosuppressive therapy was with regular steroids or immunosuppressants. Lead placement was guided by fluoroscopy, and active fixation leads were used. Restraint of the upper limb by chest tape was performed for 1 week after the procedure. Lead dislodgement was defined as a change in lead position and/or lead failure requiring reoperation. RESULTS: Twenty (3.1%) patients received immunosuppressive therapy. Among these, 15 (2.3%) patients regularly took steroids and 8 (1.2%) took immunosuppressants. Lead dislodgement occurred in 10 (1.5%) patients. Lead dislodgement was more frequent in patients with immunosuppressive therapy than in those without (3 [15%] vs. 7 [1%], p = 0.003). CONCLUSION: In patients with CIED implantation or lead addition, lead dislodgement is more frequent in patients with immunosuppressive therapy than in those without.
Asunto(s)
Desfibriladores Implantables , Inmunosupresores , Marcapaso Artificial , Humanos , Masculino , Femenino , Anciano , Estudios Retrospectivos , Inmunosupresores/efectos adversos , Inmunosupresores/uso terapéutico , Anciano de 80 o más Años , Factores de Riesgo , Resultado del Tratamiento , Persona de Mediana Edad , Remoción de Dispositivos , Dispositivos de Terapia de Resincronización CardíacaRESUMEN
AIMS: Atrial fibrillation (AF) and heart failure (HF) affect each other and are often co-morbid. The fact that HF development is not uncommon even after ablation suggests that we need a deeper understanding of the pathology of these conditions. Atrial myocardial degeneration is an underlying factor in AF patients and may be associated with HF development after ablation. This study aimed to investigate the impact of low-voltage areas (LVAs) on HF prognosis after AF ablation. METHODS AND RESULTS: This observational study included 1481 consecutive patients undergoing initial ablation for AF. Left atrial LVAs were defined as regions with a bipolar peak-to-peak voltage of <0.50 mV. Patients were divided into three groups: no LVA (LVA size indexed to body surface area <3 cm2/m2, n = 1129), small LVA (3-10 cm2/m2, n = 217), and extensive LVA (≥10 cm2/m2, n = 135). A composite endpoint of HF hospitalization or death occurred more frequently in patients with larger LVAs (3.3% vs. 6.5% vs. 13.3%, P < 0.0001) during the 3-year follow up period. The extent of LVAs was independently related to the risk of the composite endpoint with an adjusted hazard ratio of 1.55 (95% confidence interval, 1.16-2.10) for each additional step of LVA classification (P = 0.003). CONCLUSIONS: LVA presence and its extent were associated with frequent HF hospitalization and death. Underlying atrial myopathy appears to define a poor HF prognosis after AF ablation.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/etiología , Masculino , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/etiología , Atrios Cardíacos/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/métodos , Estudios de Seguimiento , Anciano , Pronóstico , Estudios Retrospectivos , Función del Atrio Izquierdo/fisiologíaRESUMEN
AIMS: Understanding of the tissue cooling properties of cryoballoon ablation during pulmonary vein (PV) isolation is lacking. The purpose of this study was to delineate the depth of the tissue cooling effect during cryoballoon freezing at the pulmonary venous ostium. METHODS AND RESULTS: A left atrial-PV model was constructed using a three-dimensional printer with data from a patient to which porcine thigh muscle of various thicknesses could be affixed. The model was placed in a 37°C water tank with a PV water flow at a rate that mimicked biological blood flow. Cryofreezing at the PV ostium was performed five times each for sliced porcine thigh muscle of 2, 4, and 6â mm thickness, and sliced muscle cooling on the side opposite the balloon was monitored. The cooling effect was assessed using the average temperature of 12 evenly distributed thermocouples covering the roof region of the left superior PV. Tissue cooling effects were in the order of the 2, 4, and 6â mm thicknesses, with an average temperature of -41.4 ± 4.2°C for 2â mm, -33.0 ± 4.0°C for 4â mm, and 8.0 ± 8.7°C for 6â mm at 180â s (P for trend <0.0001). In addition, tissue temperature drops were steeper in thin muscle (maximum temperature drop per 5 s: 5.2 ± 0.9°C, 3.9 ± 0.7°C, and 1.3 ± 0.7°C, P for trend <0.0001). CONCLUSION: The cooling effect of cryoballoon freezing is weaker in the deeper layers. Cryoballoon ablation should be performed with consideration to myocardial thickness.
Asunto(s)
Criocirugía , Venas Pulmonares , Criocirugía/métodos , Criocirugía/instrumentación , Criocirugía/efectos adversos , Animales , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Porcinos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Humanos , Modelos Cardiovasculares , Músculo Esquelético/cirugía , Modelos AnatómicosRESUMEN
BACKGROUND: The relationship between baseline yellow plaque (YP) and vascular response after stent implantation has not been fully investigated. METHODS: This was a sub-analysis of the Collaboration-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention were analyzed. Optical coherence tomography (OCT) and coronary angioscopy (CAS) were serially performed immediately and 11â¯months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. OCT and CAS findings at 11â¯months were compared between lesions with baseline YP (YP group) and lesions without baseline YP (Non-YP group). RESULTS: Baseline YP was detected in 37 lesions (42â¯%). OCT findings at 11â¯months showed that the incidence of neoatherosclerosis was significantly higher in the YP group (11â¯% versus 0â¯%, pâ¯=â¯0.028) and mean neointimal thickness tended to be lower (104⯱â¯43⯵m versus 120⯱â¯48⯵m, pâ¯=â¯0.098). CAS findings at 11â¯months demonstrated that the dominant and minimum neointimal coverage grades were significantly lower (pâ¯=â¯0.049 and Pâ¯=â¯0.026) and maximum yellow color grade was significantly higher (pâ¯<â¯0.001) in the YP group. CONCLUSIONS: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11â¯months after stent implantation.
Asunto(s)
Angioscopía , Vasos Coronarios , Intervención Coronaria Percutánea , Placa Aterosclerótica , Stents , Tomografía de Coherencia Óptica , Humanos , Masculino , Femenino , Estudios Retrospectivos , Placa Aterosclerótica/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Intervención Coronaria Percutánea/efectos adversos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Neointima/patología , Neointima/diagnóstico por imagen , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapiaRESUMEN
Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm2; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm2; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm2; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Atrios Cardíacos , Frecuencia Cardíaca , Venas Pulmonares/cirugía , Recurrencia , Factores de Riesgo , Resultado del TratamientoRESUMEN
Background: The relationship between sex differences and long-term outcomes after fractional flow reserve (FFR)- and instantaneous wave-free ratio (iFR)-guided deferral of revascularization has yet to be elucidated. MethodsâandâResults: From the J-CONFIRM registry (long-term outcomes of Japanese patients with deferral of coronary intervention based on FFR in a multicenter registry), this study included 432 lesions from 385 patients (men, 323 lesions in 286 patients; women, 109 lesions in 99 patients) with paired data of FFR and iFR. The primary endpoint was the cumulative 5-year incidence of target vessel failure (TVF), including cardiac death, target vessel-related myocardial infarction, and clinically driven target vessel revascularization. The median FFR value was lower in men than in women (0.85 [0.81, 0.88] vs. 0.87 [0.83, 0.91], P=0.002), but the iFR value was comparable between men and women (0.94 [0.90, 0.98] vs. 0.93 [0.89, 0.98], P=0.26). The frequency of discordance between FFR and iFR was comparable between men and women (19.5% vs. 23.9%, P=0.34), although with different discordance patterns (P=0.036). The cumulative incidence of 5-year TVF did not differ between men and women after adjustment for baseline characteristics (13.9% vs. 6.9%, adjusted hazard ratio 1.82 [95% confidence interval: 0.44-7.56]; P=0.41). Conclusions: Despite sex differences in the results for physiological indexes, the 5-year TVF in deferred lesions did not differ between men and women after adjustment for baseline characteristics.
RESUMEN
INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Diabetes Mellitus , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Prevalencia , Hemoglobina Glucada , Control Glucémico , Atrios Cardíacos/cirugía , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Resultado del TratamientoRESUMEN
PURPOSE: To investigate the impact of compliance with recommended procedural techniques on the midterm patency of a fluoropolymer-based drug-eluting stent (FP-DES) in the femoropopliteal artery. MATERIALS AND METHODS: This retrospective study included 200 femoropopliteal lesions (chronic limb-threatening ischemia, 59%; chronic total occlusion, 41%) in 173 patients (male, 66%; diabetes mellitus, 62%; hemodialysis, 40%) with lower extremity arterial disease who underwent intravascular ultrasound (IVUS)-guided endovascular therapy with FP-DES between January 2016 and July 2021. The primary outcome measure was restenosis, defined as a peak systolic velocity ratio of >2.4 based on the duplex US findings. The association between procedural techniques and incidence of restenosis was investigated using Cox proportional hazards regression models. RESULTS: The 2-year cumulative incidence of restenosis was 19.5% (SD ± 3.3). Multivariate analysis revealed that noncompliance with recommended procedural techniques, such as plaque burden at the stent edge of <50%, a minimum stent area (MSA) of >12 mm2, and stent placement within the P1 segment, was independently associated with an increased risk of restenosis (hazard ratios [HRs], 3.22, 4.71, and 4.67 and P = .004, P < .001, and P < .001, respectively). The 2-year restenosis risk for procedures performed in compliance with all 3-technical criteria was 8.4% (SD ± 3.4), whereas the risks for those in compliance with 2-technical criteria or 0- or 1-technical criteria were 25.0% (SD ± 6.2) and 48.6% (SD ± 10.4), respectively. HRs relative to 3-technical criteria compliance were 3.79 (P = .007) and 11.85 (P < .001), respectively. CONCLUSIONS: Noncompliance with recommended procedural techniques, including plaque burden at the stent edge of <50%, MSA of >12 mm2, and stent placement within the P1 segment, was significantly associated with an increased risk of 2-year restenosis after FP-DES implantation in the femoropopliteal artery.
Asunto(s)
Stents Liberadores de Fármacos , Enfermedad Arterial Periférica , Humanos , Masculino , Arteria Femoral/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Polímeros de Fluorocarbono , Estudios Retrospectivos , Resultado del Tratamiento , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Grado de Desobstrucción Vascular , Diseño de PrótesisAsunto(s)
Procedimientos Endovasculares , Enfermedad Arterial Periférica , Humanos , Enfermedad Crónica , Isquemia Crónica que Amenaza las Extremidades , Isquemia/diagnóstico , Isquemia/terapia , Japón/epidemiología , Recuperación del Miembro , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/epidemiología , Enfermedad Arterial Periférica/terapia , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Ensayos Clínicos como AsuntoRESUMEN
BACKGROUND: Recently, a new OCTARAY® mapping catheter was commercially launched. The catheter is designed to enable high-density mapping and precise signal recording via 48 small electrodes arranged on eight radiating splines. The purpose of this study was to compare bipolar voltage and low-voltage-area size, and mapping efficacy between the OCTARAY catheter and the PENTARAY® catheter METHODS: Twelve consecutive patients who underwent initial and second ablations for persistent atrial fibrillation within 2 years were considered for enrollment. Voltage mapping was performed twice, first during the initial ablation using the PENTARY catheter and second during the second ablation using the OCTARAY Long 3-3-3-3-3 (L3) catheter. RESULTS: Mean voltage with the OCTARAY-L3 catheter (1.64 ± 0.57 mV) was 32.3% greater than that with the PENTARAY catheter (1.24 ± 0.46 mV, p < .0001) in total left atrium. Low-voltage-area (<0.50 mV) size with the OCTARAY-L3 catheter was smaller than that with the PENTARAY catheter (6.9 ± 9.7 vs. 11.4 ± 13.0 cm2 , p < .0001). The OCTARAY-L3 catheter demonstrated greater efficacy than the PENTARAY catheter in terms of shorter mapping time (606 ± 99 vs. 782 ± 211 s, p = .008) and more mapping points (3,026 ± 838 vs. 781 ± 342 points, p < .0001). CONCLUSION: The OCTARAY catheter demonstrated higher voltage recordings, narrower low-voltage areas, and a more efficacious mapping procedure than the PENTARAY catheter.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Técnicas Electrofisiológicas Cardíacas , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , CatéteresRESUMEN
INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Remodelación Atrial , Insuficiencia Cardíaca , Femenino , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Recurrencia , Resultado del Tratamiento , MasculinoRESUMEN
BACKGROUND: Atrial cardiomyopathy is known as an underlying pathophysiological factor in the majority of patients with atrial fibrillation (AF). Left atrial low-voltage areas (LVAs) are reported to coincide with fibrosis and likely represent atrial cardiomyopathy. OBJECTIVE: The purpose of this study was to delineate differences in the long-term prognosis of patients stratified by the size of LVAs. METHODS: This observational study included 1488 consecutive patients undergoing initial ablation for AF. LVAs were defined as regions with a bipolar peak-to-peak voltage <0.50 mV. The total study population was divided into 3 groups stratified by LVA size: patients with no LVAs (n = 1136); those with small (<20 cm2) LVAs (n = 250) LVAs; and those with extensive (≥20 cm2) LVAs (n = 102). Composite endpoints of death, heart failure, and stroke were followed for up to 5 years. RESULTS: Composite endpoints developed in 105 of 1488 patients (7.1%), and AF recurrence occurred in 410 (27.6%). Composite endpoints developed more frequently in the order of patients with extensive LVAs (19.1%), small LVAs (10.8%), and no LVAs (5.1%) (P for trend <.0001). Multivariable analysis revealed that LVA presence was independently associated with higher incidence of composite endpoints, irrespective of AF recurrence (modified hazard ratio 1.73; 95% confidence interval 1.13-2.64; P = .011) CONCLUSION: LVA presence and its extent both were associated with poor long-term composite endpoints of death, heart failure, and stroke, irrespective of AF recurrence or other confounders. Underlying atrial cardiomyopathy seems to define a poor prognosis after AF ablation.
Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Insuficiencia Cardíaca , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Pronóstico , Estudios de Seguimiento , Atrios Cardíacos , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Ablación por Catéter/efectos adversos , RecurrenciaRESUMEN
BACKGROUND: There are little clinical data on imaging-guided percutaneous coronary intervention (PCI) 1 year after the biodegradable-polymer sirolimus-eluting stents (BP-SES) implantation, when the polymer disappears. METHODS: We retrospectively analyzed 2455 patients who underwent successful PCI with BP-SES or durable-polymer everolimus-eluting stents (DP-EES) between September 2011 and March 2021, and compared 2-year clinical outcomes of BP-SES (n = 459) with DP-EES (n = 1996). The outcome measures were target lesion revascularization (TLR) and major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target vessel revascularization, and stent thrombosis. Multivariate analysis using the Cox proportional hazard model and inverse probability weighting (IPW) analysis based on the propensity score were used to evaluate the clinical outcomes. RESULTS: The 2-year cumulative incidences of TLR (BP-SES: 4.9% vs. DP-SES: 6.1%, p = 0.304) and MACE (10.3% vs. 12.5%, p = 0.159) were similar between the two groups. Multivariable and IPW analysis revealed the risks of TLR (p = 0.388 and p = 0.500) and MACE (p = 0.139 and p = 0.083) also had no significant difference. There was a significant interaction between none/mild and moderate/severe calcification with respect to MACE and TLR (adjusted p for interaction = 0.036 and 0.047, respectively). The risk of MACE was significantly lower in BP-SES than in DP-EES in lesions with none/mild calcification (adjusted hazard ratio [aHR]: 0.53; 95% confidence interval [CI]: 0.30-0.91), while it was similar in those with moderate/severe calcification (aHR: 0.95; 95% CI: 0.58-1.55). CONCLUSIONS: Compared with DP-EES, BP-SES demonstrated durable 2-year clinical outcomes. However, BP-SES showed better clinical performance than DP-EES for lesions with none/mild calcification.
Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Sirolimus/farmacología , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Everolimus , Polímeros , Implantes Absorbibles , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugíaRESUMEN
PURPOSE: Despite widespread use of anti-restenosis devices, drug-coated balloons (DCBs) and drug-eluting stents (DESs), their appropriate use for femoropopliteal (FP) lesions has not been well investigated and the risk factors for restenosis have not been compared. To investigate risk factors associated with restenosis after endovascular therapy using DCB and DES for contemporary FP lesions. MATERIALS AND METHODS: This single-center, retrospective, observational study evaluated 378 FP lesions in 273 patients treated with DCB (278 lesions in 193 patients) or DES (120 lesions in 106 patients). The DCB used was high-dose DCB (IN.PACT, Admiral. Medtronic, Inc.) and DES was fluoropolymer-based DES (ELUVIA, Boston Scientific). Vessel preparation failure was defined as a residual stenosis of ≥50% and a dissection grade of D or greater on pre-dilatation angiography. The outcome measure was restenosis, and factors associated with restenosis in the DCB and DES groups were assessed using a Cox proportional hazards model. RESULTS: The 2-year restenosis rate was not significantly different between the DCB and DES groups (29%±4% vs. 24%±5%, p=0.42). Interaction analysis demonstrated that popliteal lesions and plaque burden of ≥50% were restenosis-related factors for DES but not for DCB, whereas vessel preparation failure was a factor for DCB but not for DES (p<0.05). Vessel diameter of <6 mm and nodular calcification were risk factors in both groups (p<0.05). CONCLUSION: In contemporary FP lesions, smaller vessels and nodular calcification were shared restenosis-related factors for high-dose DCB and fluoropolymer-based DES. Popliteal lesions and plaque burden of ≥50% were restenosis-related factors for fluoropolymer-based DES and vessel preparation failure for high-dose DCB. CLINICAL IMPACT: Shared and differential restenosis-related factors after endovascular therapy using high-dose drug-coated balloons (DCBs) and fluoropolymer-based drug-eluting stents (DESs) in contemporary femoropopliteal (FP) lesions are unclear. This single-center retrospective study included 378 FP lesions in 273 patients with lower-extremity arterial disease (high-dose DCB, 278 lesions in 193 patients; fluoropolymer-based DES, 120 lesions in 106 patients). Smaller vessels and calcified nodules were shared restenosis-related factors for both high-dose DCB and fluoropolymer-based DES, whereas popliteal lesions and plaque burden of ≥50% were restenosis-related factors for fluoropolymer-based DES and vessel preparation failure for high-dose DCB.