Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
1.
Sci Rep ; 14(1): 15359, 2024 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-38965290

RESUMEN

We sought to validate the ability of a novel handheld ultrasound device with an artificial intelligence program (AI-POCUS) that automatically assesses left ventricular ejection fraction (LVEF). AI-POCUS was used to prospectively scan 200 patients in two Japanese hospitals. Automatic LVEF by AI-POCUS was compared to the standard biplane disk method using high-end ultrasound machines. After excluding 18 patients due to infeasible images for AI-POCUS, 182 patients (63 ± 15 years old, 21% female) were analyzed. The intraclass correlation coefficient (ICC) between the LVEF by AI-POCUS and the standard methods was good (0.81, p < 0.001) without clinically meaningful systematic bias (mean bias -1.5%, p = 0.008, limits of agreement ± 15.0%). Reduced LVEF < 50% was detected with a sensitivity of 85% (95% confidence interval 76%-91%) and specificity of 81% (71%-89%). Although the correlations between LV volumes by standard-echo and those by AI-POCUS were good (ICC > 0.80), AI-POCUS tended to underestimate LV volumes for larger LV (overall bias 42.1 mL for end-diastolic volume). These trends were mitigated with a newer version of the software tuned using increased data involving larger LVs, showing similar correlations (ICC > 0.85). In this real-world multicenter study, AI-POCUS showed accurate LVEF assessment, but careful attention might be necessary for volume assessment. The newer version, trained with larger and more heterogeneous data, demonstrated improved performance, underscoring the importance of big data accumulation in the field.


Asunto(s)
Inteligencia Artificial , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Femenino , Masculino , Persona de Mediana Edad , Volumen Sistólico/fisiología , Anciano , Función Ventricular Izquierda/fisiología , Ecocardiografía/métodos , Ultrasonografía/métodos , Estudios Prospectivos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
2.
Int J Cardiol Heart Vasc ; 53: 101449, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39022741

RESUMEN

Background: Percutaneous left atrial appendage closure (LAAC) is an effective therapy to prevent thromboembolic events among patients with atrial fibrillation (AF). However, since the left atrial appendage (LAA) contributes to left atrial volume and serves as a buffer for increasing left atrial pressure, this procedure may impair left atrium (LA) compliance, enlarge LA, and deteriorate diastolic function. In this study, we sought to investigate the change in left atrial volume index (LAVI) following LAAC and its effect on prognosis. Methods and Results: We analyzed 225 patients from the OCEAN-LAAC registry, an ongoing, multicenter Japanese study. Comparing LAVI measurements at baseline and 6 months after LAAC, no significant increase was observed (55.0 [44.0, 70.0] ml/m2 vs. 55.0 [42.0, 75.6] ml/m2; P = 0.31). However, some patients underwent LAVI increase. Particularly, a smaller LAVI (odds ratio [OR]: 0.98 [95 % confidence interval (CI): 0.97-0.996]) and elevated tricuspid regurgitation pressure (TRPG) at baseline (OR: 1.04 [95 % CI: 1.00 - 1.08]) were significantly related to the increase in LAVI at 6-month follow-up. In addition, a 5 ml/m2 increase in LAVI was significantly associated with subsequent heart failure hospitalization (HFH) (hazard ratio: 3.37 [95 % CI: 1.18-9.65]). This association, however, was not observed in patients with lower baseline LAVI (≤55 ml/m2) but was only seen in those with a baseline LAVI over 55 ml/m2. Conclusion: Our study demonstrated an increase in LAVI after LAAC was related to smaller LAVI or elevated TRPG at baseline. The LAVI increase was significantly associated with subsequent HFH.

3.
Int J Cardiol ; : 132375, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39025133

RESUMEN

BACKGROUND: Current guidelines recommend direct oral anticoagulants (DOACs) and warfarin for patients with atrial fibrillation (AF) who have a bioprosthetic valve (BPV). However, the data related to elderly patients (aged ≥80 years) with BPV replacement and AF are limited. METHODS: This post-hoc subgroup analysis of a BPV-AF Registry enrolled 752 patients with BPV replacement and AF. The primary net outcome was a composite of cardiac death, stroke, systemic embolism, major bleeding, and cardiovascular events. RESULTS: Among 752 patients, 429 (57%) patients were ≥ 80 and 323 (43%) were < 80 years old. The higher risk in patients aged ≥80 than <80 years was significant for the net outcome (hazard ratio [HR], 2.04; 95% confidence interval [CI], 1.31-3.17; P = 0.001). After adjustment for confounders, there was no statistically significant difference between warfarin (reference) and DOAC users in the risk of net outcomes (adjusted HR, 1.26; 95% CI, 0.71-2.24; P = 0.44), stroke and systemic embolism (adjusted HR, 2.01; 95% CI, 0.48-8.38; P = 0.34), and major bleeding (adjusted HR, 0.73; 95% CI, 0.11-4.98; P = 0.75) in patients aged ≥80 years old as well as those aged <80 years. Among 489 warfarin users, the cumulative incidence of net outcomes tended to be higher in patients aged ≥80 than <80 years (12.2% vs. 5.7% at 1 year, log-rank P = 0.002). Among 263 DOAC users, however, it was similar between patients aged ≥80 and < 80 years. CONCLUSIONS: The present study demonstrated that DOAC showed similar efficacy and safety compared with warfarin even in elderly patients aged ≥80 years with BPV replacement and AF.

4.
Echocardiography ; 41(8): e15892, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39023286

RESUMEN

PURPOSE: The extraaortic-valvular cardiac damage (EVCD) Stage has shown potential for risk stratification for patients with aortic stenosis (AS). This study aimed to examine the usefulness of the EVCD Stage in risk stratification of patients with moderate AS and reduced left ventricular ejection fraction (LVEF). METHODS: Clinical data from patients with moderate AS (aortic valve area, .60-.85 cm2/m2; peak aortic valve velocity, 2.0-4.0 m/s) and reduced LVEF (LVEF 20%-50%) were analyzed during 2010-2019. Patients were categorized into three groups: EVCD Stages 1 (LV damage), 2 (left atrium and/or mitral valve damage), and 3/4 (pulmonary artery vasculature and/or tricuspid valve damage or right ventricular damage). The primary endpoint included a composite of cardiac death and heart failure hospitalization, with non-cardiac death as a competing risk. RESULTS: The study included 130 patients (mean age 76.4 ± 6.8 years; 62.3% men). They were categorized into three groups: 26 (20.0%) in EVCD Stage 1, 66 (50.8%) in Stage 2, and 48 (29.2%) in Stage 3/4. The endpoint occurred in 54 (41.5%) patients during a median follow-up of 3.2 years (interquartile range, 1.4-5.1). Multivariate analysis indicated EVCD Stage 3/4 was significantly associated with the endpoint (hazard ratio 2.784; 95% confidence interval 1.197-6.476; P = .017) compared to Stage 1, while Stage 2 did not (hazard ratio 1.340; 95% confidence interval .577-3.115; P = .500). CONCLUSION: The EVCD staging system may aid in the risk stratification of patients with moderate AS and reduced LVEF.


Asunto(s)
Estenosis de la Válvula Aórtica , Volumen Sistólico , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Anciano , Volumen Sistólico/fisiología , Pronóstico , Ecocardiografía/métodos , Medición de Riesgo/métodos , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda/fisiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología
5.
Circ J ; 88(7): 1187-1197, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38763735

RESUMEN

BACKGROUND: Limited data are available regarding clinical outcomes after percutaneous left atrial appendage closure using WATCHMAN FLX (WM-FLX) and WATCHMAN-2.5 (WM2.5) devices in Asian patients.Methods and Results: Data of 1,464 consecutive patients (WM-FLX, n=909; WM2.5, n=555) were extracted from a Japanese multicenter registry, and clinical data were compared between the 2 groups. No in-hospital deaths, periprocedural stroke, or device embolization occurred. Procedural success was significantly higher in the WM-FLX than WM2.5 group (95.8% vs. 91.9%; P=0.002) owing to the lower incidence of periprocedural pericardial effusion (0.55% vs. 1.8%; P=0.021). No significant differences in all-cause death, postprocedural stroke, and device-related thrombus were observed between the 2 groups. However, the cumulative bleeding rate at 1 year was substantially lower in the WM-FLX group (7.8% vs. 16.4%; P<0.001). Landmark analysis of bleeding events highlighted lower bleeding rates in the WM-FLX than WM2.5 group within the first 6 months (6.4% vs. 14.8%; P<0.001), with comparable bleeding rates over the 6- to 12-month period (1.5% vs. 3.2%, respectively; P=0.065). CONCLUSIONS: This study demonstrated higher early safety and lower 1-year bleeding rates in the WM-FLX than WM2.5 group. The lower bleeding events with WM-FLX are likely due to multiple factors other than purely difference in devices, such as postprocedural drug regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Sistema de Registros , Humanos , Anciano , Apéndice Atrial/cirugía , Masculino , Femenino , Anciano de 80 o más Años , Fibrilación Atrial/cirugía , Japón , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Persona de Mediana Edad , Cierre del Apéndice Auricular Izquierdo
6.
Heart Vessels ; 39(8): 687-695, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38710808

RESUMEN

BACKGROUND: Severe aortic valve stenosis (AS) and atrial fibrillation (AF) are risk factors of hemodynamic instability in heart failure (HF) management due to low cardiac output, respectively. Therefore, the treatment of HF due to severe AS complicated with AF is anticipated to be difficult. Tolvaptan, a vasopressin V2 receptor inhibitor, is effective in controlling acute decompensated heart failure (ADHF) with hemodynamic stability. However, its clinical efficacy against ADHF caused by AS with AF remains to be determined. METHODS: Clinical information (from September 2014 to December 2017) of 59 patients diagnosed with ADHF due to severe AS (20 patients with AF; 39 patients with sinus rhythm [SR]) was obtained from the LOHAS registry. The registry collected data from seven hospitals and assessed the short-term effects of tolvaptan in patients hospitalized for ADHF with severe AS. We attempted to identify clinical differences from baseline up to 4 days, comparing patients with AF (AF group) versus those with SR (SR group). RESULTS: There were no significant differences between the groups in age (83.7 ± 4.5 vs. 85.8 ± 6.9 years, respectively; p = 0.11) and aortic valve area (0.60 [0.46-0.73] vs. 0.56 [0.37-0.70] cm2, respectively; p = 0.50). However, left atrial volume was larger (104 [85-126] vs. 87 [64-103] mL, respectively; p < 0.01), whereas stroke volume was lower (51.6 ± 14.8 vs. 59.0 ± 18.7 mL, respectively; p = 0.08) in the AF group versus the SR group. Body weight decreased daily from baseline up to day 4 in both groups (from 55.4 to 53.2 kg [p < 0.01] and from 53.5 to 51.0 kg [p < 0.01], respectively) without change in heart rate. Notably, the systolic blood pressure decreased slightly in the AF group after 2 days of treatment with tolvaptan. CONCLUSIONS: Short-term treatment with tolvaptan improved HF in patients hospitalized for severe AS, regardless of the presence of AF or SR. After achieving sufficient diuresis, a slight decrease in blood pressure was observed in the AF group, suggesting an appropriate timeframe for safe and effective use of tolvaptan.


Asunto(s)
Antagonistas de los Receptores de Hormonas Antidiuréticas , Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Sistema de Registros , Tolvaptán , Humanos , Tolvaptán/uso terapéutico , Masculino , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/diagnóstico , Antagonistas de los Receptores de Hormonas Antidiuréticas/uso terapéutico , Anciano de 80 o más Años , Resultado del Tratamiento , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Anciano , Enfermedad Aguda , Japón/epidemiología , Hemodinámica/efectos de los fármacos
7.
Am J Cardiol ; 223: 156-164, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-38797196

RESUMEN

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estudios Retrospectivos , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Causas de Muerte/tendencias , Anciano , Puntaje de Propensión , Incidencia , Válvula Aórtica/cirugía , Estudios de Seguimiento , Insuficiencia Cardíaca , Resultado del Tratamiento , Factores de Riesgo
9.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726714

RESUMEN

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Hemodinámica , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Mortalidad Hospitalaria
10.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629311

RESUMEN

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Anciano , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Japón , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Factores de Tiempo , Estudios Prospectivos , Factores de Riesgo , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Medición de Riesgo , Recuperación de la Función , Lesiones Cardíacas/mortalidad , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Lesiones Cardíacas/diagnóstico por imagen
11.
J Clin Med ; 13(7)2024 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-38610628

RESUMEN

Background: Transthoracic echocardiography (TTE) is the gold standard modality for evaluating cardiac morphology, function, and hemodynamics in clinical practice. While artificial intelligence (AI) is expected to contribute to improved accuracy and is being applied clinically, its impact on daily clinical practice has not been fully evaluated. Methods: We retrospectively examined 30 consecutive patients who underwent AI-equipped TTE at a single institution. All patients underwent manual and automatic measurements of TTE parameters using the AI-equipped TTE. Measurements were performed by three sonographers with varying experience levels: beginner, intermediate, and expert. Results: A comparison between the manual and automatic measurements assessed by the experts showed extremely high agreement in the left ventricular (LV) filling velocities (E wave: r = 0.998, A wave: r = 0.996; both p < 0.001). The automated measurements of LV end-diastolic and end-systolic diameters were slightly smaller (-2.41 mm and -1.19 mm) than the manual measurements, although without significant differences, and both methods showing high agreement (r = 0.942 and 0.977, both p < 0.001). However, LV wall thickness showed low agreement between the automated and manual measurements (septum: r = 0.670, posterior: r = 0.561; both p < 0.01), with automated measurements tending to be larger. Regarding interobserver variabilities, statistically significant agreement was observed among the measurements of expert, intermediate, and beginner sonographers for all the measurements. In terms of measurement time, automatic measurement significantly reduced measurement time compared to manual measurement (p < 0.001). Conclusions: This preliminary study confirms the accuracy and efficacy of AI-equipped TTE in routine clinical practice. A multicenter study with a larger sample size is warranted.

12.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38660100

RESUMEN

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

13.
Eur Heart J Open ; 4(2): oeae018, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38529170

RESUMEN

Aims: Current evidence on the prognostic value of exercise stress echocardiography (ESE) in asymptomatic patients with low-gradient severe aortic stenosis (AS) is limited. Therefore, this study aimed to elucidate its prognostic implications for patients with low-gradient severe AS and determine the added value of ESE in risk stratification for this population. Methods and results: This retrospective observational study included 122 consecutive asymptomatic patients with either moderate [mean pressure gradient (MPG) < 40 mmHg and aortic valve area (AVA) 1.0-1.5 cm2] or low-gradient severe (MPG < 40 mmHg and AVA < 1.0 cm2) AS and preserved left ventricular ejection fraction (≥50%) who underwent ESE. All patients were followed up for AS-related events. Of 143 patients, 21 who met any exclusion criteria, including early interventions, were excluded, and 122 conservatively managed patients [76.5 (71.0-80.3) years; 48.3% male] were included in this study. During a median follow-up period of 989 (578-1571) days, 64 patients experienced AS-related events. Patients with low-gradient severe AS had significantly lower event-free survival rates than those with moderate AS (log-rank test, P < 0.001). Multivariable Cox regression analysis showed that the mitral E/e' ratio during exercise was independently associated with AS-related events (hazard ratio = 1.075, P < 0.001) in patients with low-gradient severe AS. Conclusion: This study suggests that asymptomatic patients with low-gradient severe AS have worse prognoses than those with moderate AS. Additionally, the mitral E/e' ratio during exercise is a useful parameter for risk stratification in patients with low-gradient severe AS.

15.
J Echocardiogr ; 22(1): 1-15, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38358595

RESUMEN

Stress echocardiography has been one of the most promising methods for the diagnosis of ischemic heart disease, hypertrophic cardiomyopathy, and pulmonary hypertension. The Japanese Society of Echocardiography produced practical guidance for the implementation of stress echocardiography in 2018. At that time, stress echocardiography was not yet widely disseminated in Japan; therefore, the 2018 practical guidance for the implementation of stress echocardiography included a report on stress echocardiography and a specific protocol to promote its use at many institutions in Japan in the future. And now, an era of renewed interest and enthusiasm surrounding the diagnosis and treatment of valvular heart disease and heart failure with preserved ejection fraction (HFpEF) has come, which are driven by emerging trans-catheter procedures and new recommended guideline-directed medical therapy. Based on the continued evidence of stress echocardiography, the new practical guideline that describes the safe and effective methodology of stress echocardiography is now created by the Guideline Development Committee of the Japanese Society of Echocardiography and is designed to expand the use of stress echocardiography for valvular heart disease and HFpEF, as well as ischemic heart disease, hypertrophic cardiomyopathy, and pulmonary hypertension. The readers are encouraged to perform stress echocardiography which will enhance the diagnosis and management of these patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Insuficiencia Cardíaca , Enfermedades de las Válvulas Cardíacas , Hipertensión Pulmonar , Isquemia Miocárdica , Humanos , Ecocardiografía de Estrés/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Hipertensión Pulmonar/diagnóstico por imagen , Volumen Sistólico , Isquemia Miocárdica/diagnóstico por imagen
16.
J Clin Med ; 13(3)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38337545

RESUMEN

Background: Transcatheter edge-to-edge mitral valve repair (TEER) has emerged as a viable approach to addressing substantial secondary mitral regurgitation. In the contemporary landscape where ultimate heart failure-specific therapies, such as cardiac replacement modalities, are available, prognosticating a high-risk cohort susceptible to early cardiac mortality post-TEER is pivotal for formulating an effective therapeutic regimen. Methods: Our study encompassed individuals with secondary mitral regurgitation and chronic heart failure enlisted in the multi-center (Optimized CathEter vAlvular iNtervention (OCEAN)-Mitral registry. We conducted an assessment of baseline variables associated with cardiac death within one year following TEER. Results: Amongst the 1517 patients (median age: 78 years, 899 males), 101 experienced cardiac mortality during the 1-year observation period after undergoing TEER. Notably, a history of heart failure-related admissions within the preceding year, utilization of intravenous inotropes, and elevated plasma B-type natriuretic peptide levels emerged as independent prognosticators for the primary outcome (p < 0.05 for all). Subsequently, we devised a novel risk-scoring system encompassing these variables, which significantly stratified the cumulative incidence of the 1-year primary outcome (16%, 8%, and 4%, p < 0.001). Conclusions: Our study culminated in the development of a new risk-scoring system aimed at predicting 1-year cardiac mortality post-TEER.

17.
JACC Case Rep ; 29(4): 102216, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38379648

RESUMEN

A 70-year-old patient with paroxysmal atrial fibrillation underwent left atrial appendage closure. The patient experienced transient hypotension during device implantation. The procedure was abandoned because of ST-T-wave changes on electrocardiography and elevated coronary flow velocity on transesophageal echocardiography, which indicated that the device caused coronary artery compression.

19.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37543193

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Calidad de Vida , Análisis Costo-Beneficio , Estudios Prospectivos , Fragilidad/etiología , Estenosis de la Válvula Aórtica/etiología , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
20.
Circ J ; 88(4): 510-516, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37438144

RESUMEN

BACKGROUND: Renal congestion is a potential prognostic factor in patients with heart failure and recently, assessment has become possible with intrarenal Doppler ultrasonography (IRD). The association between renal congestion assessed by IRD and outcomes after mitral transcatheter edge-to-edge repair (TEER) is unknown, so we aimed to clarify renal congestion and its prognostic implications in patients with mitral regurgitation (MR) who underwent TEER using MitraClip system.Methods and Results: Patients with secondary MR who underwent TEER and were assessed for intrarenal venous flow (IRVF) by IRD were classified according to their IRVF pattern as continuous or discontinuous. Of the 105 patients included, 78 patients (74%) formed the continuous group and 27 (26%) were the discontinuous group. Kaplan-Meier analysis revealed significant prognostic power of the IRVF pattern for predicting the composite outcome of all-cause death and heart failure rehospitalization (log-rank P=0.0257). On multivariate Cox regression analysis, the composite endpoint was independently associated with the discontinuous IRVF pattern (hazard ratio, 3.240; 95% confidence interval, 1.300-8.076; P=0.012) adjusted using inverse probability of treatment weighting. CONCLUSIONS: IRVF patterns strongly correlated with clinical outcomes without changes in renal function. Thus, they may be useful for risk stratification after mitral TEER for patients with secondary MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Angiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Riñón/diagnóstico por imagen , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA