Perfusion ; 38(5): 1045-1052, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-35676779

RESUMEN

OBJECTIVE: Cerebrovascular autoregulation impairment has been associated with stroke risk in cardiac surgery. We hypothesized that greater arterial emboli exposure in open-chamber surgery might promote dysautoreguation. METHODS: Forty patients underwent closed or open-chamber surgery. Transcranial Doppler detected emboli and measured bilateral middle cerebral artery flow velocities. Cerebral autoregulation was assessed by averaging the mean velocity index ("Mx," a continuous moving correlation between cerebral blood flow velocity and mean arterial pressure) over 30 min before and after aortic cross-clamp removal. RESULTS: Median (interquartile range) emboli counts were 775 (415, 1211) and 2664 (793, 3734) in the closed-chamber and open-chamber groups. Most appeared after the removal of the aortic cross-clamp (open-chamber 1631 (606, 2296)), (closed-chamber 229 (142, 384)), with emphasis on the right hemisphere (open-chamber: 826 (371, 1622)), (closed-chamber 181 (66, 276)). Linear mixed model analyses of mean velocity index change showed no significant overall effect of group (0.08, 95% CI: -0.04, 0.21; p = 0.19) or side (0.01, 95% CI: -0.03, 0.05; p = 0.74). There was an interaction between group and side (p = 0.001), manifesting as a greater increase in mean velocity index in the right hemisphere in the open than the closed group (mean difference: 0.15, 95% CI: 0.02, 0.27; p = 0.03). CONCLUSIONS: Overall, change in mean velocity index before and after cross-clamp removal did not differ between groups. However, most emboli entered the right cerebral hemisphere where this change was significantly greater in the open-chamber group, suggesting a possible association between embolic exposure and dysautoregulation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Humanos , Monitoreo Intraoperatorio , Estudios Prospectivos , Homeostasis/fisiología , Circulación Cerebrovascular/fisiología , Ultrasonografía Doppler Transcraneal , Velocidad del Flujo Sanguíneo/fisiología
2.
Perfusion ; 37(7): 715-721, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34112049

RESUMEN

OBJECTIVE: Exposure to cerebral emboli is ubiquitous and may be harmful in cardiac surgery utilizing cardiopulmonary bypass. This was a prospective observational study aiming to compare emboli exposure in closed-chamber with open-chamber cardiac surgery, distinguish particulate from gaseous emboli and examine cerebral laterality in distribution. METHODS: Forty patients underwent either closed-chamber procedures (n = 20) or open-chamber procedures (n = 20). Emboli (gaseous and solid) were detected using transcranial Doppler in both middle cerebral arteries in two monitoring phases: 1, initiation of bypass to the removal of the aortic cross-clamp; and 2, removal of aortic cross-clamp to 20 minutes after venous decannulation. RESULTS: Total (median (interquartile range)) emboli counts (both phases) were 898 (499-1366) and 2617 (1007-5847) in closed-chamber and open-chamber surgeries, respectively. The vast majority were gaseous; median 794 (closed-chamber surgery) and 2240 (open-chamber surgery). When normalized for duration, there was no difference between emboli exposures in closed-chamber and open-chamber surgery in phase 1: 6.8 (3.6-15.2) versus 6.4 (2.0-18.1) emboli per minute, respectively. In phase 2, closed-chamber surgery cases were exposed to markedly fewer emboli than open-chamber surgery cases: 9.6 (5.1-14.9) versus 43.3 (19.7-60.3) emboli per minute, respectively. More emboli (total) passed into the right cerebral circulation: 985 (397-2422) right versus 376 (198-769) left. CONCLUSIONS: Patients undergoing open-chamber surgery are exposed to considerably higher numbers of cerebral arterial emboli after removal of the aortic cross-clamp than those undergoing closed-chamber surgery, and more emboli enter the right middle cerebral artery than the left. These results may help inform the evaluation of the pathophysiological impact of emboli exposure.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Embolia Aérea , Embolia Intracraneal , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Puente Cardiopulmonar/métodos , Embolia Aérea/etiología , Humanos , Embolia Intracraneal/etiología , Ultrasonografía Doppler Transcraneal
3.
Perfusion ; 31(5): 409-17, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26643883

RESUMEN

OBJECTIVE: To compare the emboli filtration efficiency of five integrated or non-integrated oxygenator-filter combinations in cardiopulmonary bypass circuits. METHODS: Fifty-one adult patients underwent surgery using a circuit with an integrated filtration oxygenator or non-integrated oxygenator with a separate 20 µm arterial line filter (Sorin Dideco Avant D903 + Pall AL20 (n=12), Sorin Inspire 6 M + Pall AL20 (n=10), Sorin Inspire 6M F (n=9), Terumo FX25 (n=10), Medtronic Fusion (n=10)). The Emboli Detection and Classification quantifier was used to count emboli upstream and downstream of the primary filter throughout cardiopulmonary bypass. The primary outcome measure was to compare the devices in respect of the median proportion of emboli removed. RESULTS: One device (Sorin Inspire 6 M + Pall AL20) exhibited a significantly greater median percentage reduction (96.77%, IQR=95.48 - 98.45) in total emboli counts compared to all other devices tested (p=0.0062 - 0.0002). In comparisons between the other units, they all removed a greater percentage of emboli than one device (Medtronic Fusion), but there were no other significant differences. CONCLUSION: The new generation Sorin Inspire 6 M, with a stand-alone 20 µm arterial filter, appeared most efficient at removing incoming emboli from the circuit. No firm conclusions can be drawn about the relative efficacy of emboli removal by units categorised by class (integrated vs non-integrated); however, the stand-alone 20 µm arterial filter presently sets a contemporary standard against which other configurations of equipment can be judged.


Asunto(s)
Puente Cardiopulmonar/efectos adversos , Embolia Aérea/prevención & control , Oxigenadores , Dispositivos de Acceso Vascular , Embolia Aérea/diagnóstico , Filtración/instrumentación , Humanos