Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Open Heart ; 9(2)2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36288820

RESUMEN

BACKGROUND: Bioresorbable vascular scaffolds (BVS) were designed to reduce the rate of late adverse events observed in conventional drug-eluting stents (DES) by dissolving once they have restored lasting patency. OBJECTIVES: Compare the safety and efficacy of BVS versus DES in patients receiving percutaneous coronary intervention for coronary artery disease across a complete range of randomised controlled trial (RCT) follow-up intervals. METHODS: A systematic review and meta-analysis was performed using Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. MEDLINE, EMBASE and Web of Science were searched from inception through 5 January 2022 for RCTs comparing the clinical outcomes of BVS versus DES. The primary safety outcome was stent/scaffold thrombosis (ST), and the primary efficacy outcome was target lesion failure (TLF: composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR)). Secondary outcomes were patient-oriented composite endpoint (combining all-death, all-MI and all-revascularisation), its individual components and those of TLF. Studies were appraised using Cochrane's Risk of Bias tool and meta-analysis was performed using RevMan V.5.4. RESULTS: 11 919 patients were randomised to receive either BVS (n=6438) or DES (n=5481) across 17 trials (differing follow-up intervals from 3 months to 5 years). BVS demonstrated increased risk of ST across all timepoints (peaking at 2 years with risk ratio (RR): 3.47; 95% CI 1.80 to 6.70; p=0.0002). Similarly, they showed increased risk of TLF (peaking at 3 years, RR: 1.35; 95% CI 1.07 to 1.70; p=0.01) resulting from high rates of TVMI and ID-TLR. Though improvements were observed after device dissolution (5-year follow-up), these were non-significant. All other outcomes were statistically equivalent. Applicability to all BVS is limited by 91% of the BVS group receiving Abbott's Absorb. CONCLUSION: This meta-analysis demonstrates that current BVS are inferior to contemporary DES throughout the first 5 years at minimum.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Humanos , Stents Liberadores de Fármacos/efectos adversos , Implantes Absorbibles , Resultado del Tratamiento , Intervención Coronaria Percutánea/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Infarto del Miocardio/complicaciones , Trombosis/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA