RESUMEN
Transmission Fourier transform infrared (FTIR) spectroscopic method using 100 µm KCl cell was applied for the determination of total polar compounds (TPC), carbonyl value (CV), conjugated diene (CD) and conjugated triene (CT) in canola oil (CLO) during potato chips frying at 180 °C. The calibration models were developed for TPC, CV, CD and CT using partial least square (PLS) chemometric technique. Excellent regression coefficients (R(2)) and root mean square error of prediction values for TPC, CV, CD and CT were found to be 0.999, 0.992, 0.998 and 0.999 and 0.809, 0.690, 1.26 and 0.735, respectively. The developed calibration models were applied on samples of canola oil drawn during potato chips frying process. A linear relationship was obtained between CD and TPC with a good correlation of coefficient (R(2)=0.9816). Results of the study clearly indicated that transmission FTIR-PLS method could be used for quick and precise evaluation of oxidative changes during the frying process without using any organic solvent.
Asunto(s)
Culinaria , Bases de Datos de Compuestos Químicos , Ácidos Grasos Monoinsaturados/química , Calibración , Análisis de los Mínimos Cuadrados , Oxidación-Reducción , Aceite de Brassica napus , Espectroscopía Infrarroja por Transformada de FourierRESUMEN
A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887cm(-1). Excellent coefficient of determination (R(2)) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product.
Asunto(s)
Cefixima/análisis , Preparaciones Farmacéuticas/química , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Administración Oral , Calibración , Cefixima/química , Cromatografía Líquida de Alta Presión , Polvos/química , Estándares de Referencia , Suspensiones/químicaRESUMEN
A rapid, reliable and cost effective analytical procedure for the estimation of ibuprofen in pharmaceutical formulations and human urine samples was developed using transmission Fourier Transform Infrared (FT-IR) spectroscopy. For the determination of ibuprofen, a KBr window with 500 µm spacer was used to acquire the FT-IR spectra of standards, pharmaceuticals as well as urine samples. Partial least square (PLS) calibration model was developed based on region from 1807 to 1,461 cm(-1) using ibuprofen standards ranging from 10 to 100 µg ml(-1). The developed model was evaluated by cross-validation to determine standard error of the models such as root mean square error of calibration (RMSEC), root mean square error of cross validation (RMSECV) and root mean square error of prediction (RMSEP). The coefficient of determination (R(2)) achieved was 0.998 with minimum errors in RMSEC, RMSECV and RMSEP with the value of 1.89%, 1.63% and 4.07%, respectively. The method was successfully applied to urine and pharmaceutical samples and obtained good recovery (98-102%).
Asunto(s)
Antiinflamatorios no Esteroideos/análisis , Antiinflamatorios no Esteroideos/orina , Ibuprofeno/análisis , Ibuprofeno/orina , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Calibración , Humanos , Análisis de los Mínimos Cuadrados , Sensibilidad y Especificidad , ComprimidosRESUMEN
The prospect of using single bounce attenuated total reflectance (SB-ATR)-Fourier transform infrared (FTIR) spectroscopy as a rapid quantitative tool to determine the main fatty acid groups present in different edible oils was investigated. Partial least squares (PLS) calibrations were developed using SB-ATR-FTIR spectra which were associated with fatty acid groups (saturated, trans, mono- and polyunsaturated) using quantitative data obtained by gas chromatography (GC). Good calibrations were obtained for all main four fat groups (saturated, mono, trans and polyunsaturated) with excellent precision. The coefficient of determination (R(2)), root mean square error of prediction (RMSEP) and bias for validation set were obtained as 0.999, 2.43 and 0.998 for saturated; 0.999, 1.850 and 0.003 for mono; 0.999, 0.625 and -0.001 for trans while for poly the values were 0.999, 1.170 and 0.003, respectively. The results of 13 validation samples for total saturated, mono, trans and polyunsaturated fats by FI-IR were found in the range of 8.16-55.16, 37.62-74.75, 0.20-18.16 and 1.36-62.35%, respectively. The present study shows that it may well be possible to expand the utility of SB-ATR-FTIR spectroscopy not only to provide isolated trans data, but also serve as a simple, rapid and quantitative means of categorizing the main groups present in the edible oils. The information obtained would be useful for meeting the new lipid nutritional labeling requirements.