Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-29550684

RESUMEN

Vaccine production is a biological process in which variation in time and output is inevitable. Thus, the application of Process Analytical Technologies (PAT) will be important in this regard. Headspace solid - phase microextraction (HS-SPME) coupled with GC-MS can be used as a PAT for process monitoring. This method is suitable to chemical profiling of volatile organic compounds (VOCs) emitted from microorganisms. Tetanus is a lethal disease caused by Clostridium tetani (C. tetani) bacterium and vaccination is an ultimate way to prevent this disease. In this paper, SPME fiber was used for the investigation of VOCs emerging from C. tetani during cultivation. Different types of VOCs such as sulfur-containing compounds were identified and some of them were selected as biomarkers for bioreactor monitoring during vaccine production. In the second step, the portable dynamic air sampling (PDAS) device was used as an interface for sampling VOCs by SPME fibers. The sampling procedure was optimized by face-centered central composite design (FC-CCD). The optimized sampling time and inlet gas flow rates were 10 min and 2 m L s-1, respectively. PDAS was mounted in exhausted gas line of bioreactor and 42 samples of VOCs were prepared by SPME fibers in 7 days during incubation. Simultaneously, pH and optical density (OD) were evaluated to cultivation process which showed good correlations with the identified VOCs (>80%). This method could be used for VOCs sampling from off-gas of a bioreactor to monitoring of the cultivation process.


Asunto(s)
Reactores Biológicos/microbiología , Clostridium tetani/metabolismo , Cromatografía de Gases y Espectrometría de Masas/métodos , Microextracción en Fase Sólida/métodos , Clostridium tetani/química , Compuestos Orgánicos Volátiles/análisis , Compuestos Orgánicos Volátiles/metabolismo
2.
Anal Bioanal Chem ; 409(29): 6739-6744, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29030669

RESUMEN

A novel and efficient headspace solid-phase microextraction (HS-SPME) method, followed by gas chromatography mass spectrometry (GC-MS), was developed to study volatile organic compounds (VOCs) emerging from microorganisms. Two homemade SPME fibers, a semi-polar poly (dimethylsiloxane) (PDMS) fiber, and a polar polyethylene glycol (PEG) fiber, along with two commercial fibers (PDMS and PDMS/DVB) were used to collect VOCs emerging from Clostridium tetani which was cultured in different media. The adsorbed VOCs were desorbed and identified, in vitro, using GC-MS. The adsorption efficiency was improved by optimizing the time duration of adsorption and desorption. About 50 components were identified by the proposed method. The main detected compounds appeared to be sulfur containing compounds such as butanethioic acid S-methyl ester, dimethyl trisulfide, and dimethyl tetrasulfide. These volatile sulfur containing compounds are derived from amino acids containing the sulfur element, which probably coexist in the mentioned bacterium or are added to the culture media. The developed HS-SPME-GC-MS method allowed the determination of the chemical fingerprint of Clostridium tetani volatile constituents, and thus provides a new, simple, and reliable tool for studying the growth of microorganisms. Graphical abstract Investigation of biogenic VOCs released from Clostridium tetani using SPME-GC-MS.


Asunto(s)
Clostridium tetani/química , Microextracción en Fase Sólida/métodos , Compuestos Orgánicos Volátiles/análisis , Adsorción , Dimetilpolisiloxanos/química , Cromatografía de Gases y Espectrometría de Masas , Polietilenglicoles/química , Compuestos Orgánicos Volátiles/química
3.
Appl Opt ; 56(11): E58-E63, 2017 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-28414342

RESUMEN

In this work, a combined flow injection-photo thermal lens microscopy (FI-PTLM) system was used for highly sensitive determination of captopril as an angiotensin-converting enzyme inhibitor. Captopril has no absorption in the visible range, but due to its thiol group could interact with gold nanoparticles (GNPs). GNPs, because of their surface plasmon resonance (SPR), have absorption in the visible range, but their interaction with a low concentration of captopril shows no effective change in UV-Vis spectrophotometry because their aggregation is slight. On the contrary, at the same condition, the PTLM with a visible light source enables sensitive measurement of this compound. The thiol group of captopril binds to the surface of GNPs and decreases the SPR. At the optimum condition in the focal volume of 2.68 fL (f=10-15), the obtained range of linearity was 50-800 nM. The developed method was successfully applied for the determination of captopril in human serum and pharmaceutical samples.


Asunto(s)
Inhibidores de la Enzima Convertidora de Angiotensina/análisis , Captopril/análisis , Oro , Nanopartículas del Metal/análisis , Microscopía Electrónica de Transmisión , Inhibidores de la Enzima Convertidora de Angiotensina/sangre , Inhibidores de la Enzima Convertidora de Angiotensina/química , Captopril/sangre , Captopril/química , Diseño de Equipo , Humanos , Lentes , Luz , Nanopartículas del Metal/química , Espectrofotometría/instrumentación , Espectrofotometría/métodos , Resonancia por Plasmón de Superficie , Comprimidos/química
4.
Talanta ; 135: 7-17, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25640119

RESUMEN

In this work, a rapid HPLC-DAD method has been developed for the analysis of six antibiotics (amoxicillin, metronidazole, sulfamethoxazole, ofloxacine, sulfadiazine and sulfamerazine) in the sewage treatment plant influent and effluent samples. Decreasing the chromatographic run time to less than 4 min as well as lowering the cost per analysis, were achieved through direct injection of the samples into the HPLC system followed by chemometric analysis. The problem of the complete separation of the analytes from each other and/or from the matrix ingredients was resolved as a posteriori. The performance of MCR/ALS and U-PLS/RBL, as second-order algorithms, was studied and comparable results were obtained from implication of these modeling methods. It was demonstrated that the proposed methods could be used promisingly as green analytical strategies for detection and quantification of the targeted pollutants in wastewater samples while avoiding the more complicated high cost instrumentations.


Asunto(s)
Antibacterianos/análisis , Aguas Residuales/análisis , Contaminantes Químicos del Agua/análisis , Amoxicilina/análisis , Cromatografía Líquida de Alta Presión/métodos , Tecnología Química Verde , Metronidazol/análisis , Ofloxacino/análisis , Sulfadiazina/análisis , Sulfamerazina/análisis , Sulfametoxazol/análisis
5.
J Fluoresc ; 24(3): 855-8, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24522346

RESUMEN

A very sensitive and selective spectrofluorimetric method has been developed for nickel (ΙΙ) determination in environmental samples. The method is based on measuring the decrease in fluorescence intensity of murexide after nickel (ΙΙ) binding. The intensity of the fluorescence emission peak was measured at ex/em 345/431 nm in several solutions with pH interval 3.0-7.0. The fluorescence intensity decrease was found to be linear in the concentration range of 0.007 mg.L(-1) to 0.1 mg.L(-1) and 0.1 mg.L(-1) to 20 mg.L(-1) of nickel (ΙΙ) by using 10(-4) M murexide at pH 3. The detection limit was found 0.004 mg.L(-1). Relatively large excesses of over 20 cations and anions do not interfere. The method was successfully applied to the analysis of nickel (ΙΙ) in sea, rain and ground water. This method is very precise and accurate (R.S.D. = 0.42% for the determination of 0.05 mg.L-(1) nickel in 10 replicates).


Asunto(s)
Agua Subterránea/análisis , Murexida/química , Níquel/análisis , Níquel/química , Lluvia/química , Agua de Mar/análisis , Espectrometría de Fluorescencia/métodos , Fluorescencia , Concentración de Iones de Hidrógeno , Límite de Detección , Murexida/metabolismo , Níquel/metabolismo
6.
Pharm Dev Technol ; 12(6): 573-80, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-18161630

RESUMEN

A novel analytical procedure has been developed for quantitative determination of levodopa and carbidopa in aqueous binary solutions acidified by HCl and without any other sample pretreatment. The method is based partially on least squares treatment of data obtained by attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectrometry in 1211-1315 cm(-1) and 1488-1550 cm(-1) spectral regions. The simple, rapid, and accurate proposed method was applied to determine levodopa and carbidopa in Levodopa-C tablets. The statistical parameters, such as R2, RSD, SEE, SECV, LOD, and recovery were evaluated. Number of factors, scans, and resolution were optimized. In this method R2 and RSD for levodopa and carbidopa were (0.9965, 1.209) and (0.9537, 0.813), respectively.


Asunto(s)
Antiparkinsonianos/análisis , Carbidopa/análisis , Levodopa/análisis , Cromatografía Líquida de Alta Presión , Interpretación Estadística de Datos , Combinación de Medicamentos , Espectroscopía Infrarroja por Transformada de Fourier , Comprimidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA