Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Sci Rep ; 9(1): 13016, 2019 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-31506584

RESUMEN

Almost a third of patients fulfilling current guidelines criteria have suboptimal responses following cardiac resynchronization therapy (CRT). Circulating biomarkers may help identify these patients. We aimed to assess the predictive role of full blood count (FBC) parameters in prognosis of heart failure (HF) patients undergoing CRT device implantation. We enrolled 612 consecutive CRT patients and FBC was measured within 24 hours prior to implantation. The follow-up period was a median of 1652 days (IQR: 837-2612). The study endpoints were i) composite of all-cause mortality or transplant, and ii) reverse left ventricular (LV) remodeling. On multivariate analysis [hazard ratio (HR), 95% confidence interval (CI)] only red cell count (RCC) (p = 0.004), red cell distribution width (RDW) (p < 0.001), percentage of lymphocytes (p = 0.03) and platelet count (p < 0.001) predicted all-cause mortality. Interestingly, RDW (p = 0.004) and platelet count (p = 0.008) were independent predictors of reverse LV remodeling. This is the first powered single-centre study to demonstrate that RDW and platelet count are independent predictors of long-term all-cause mortality and/or heart transplant in CRT patients. Further studies, on the role of these parameters in enhancing patient selection for CRT implantation should be conducted to confirm our findings.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Índices de Eritrocitos , Insuficiencia Cardíaca/mortalidad , Anciano , Recuento de Células Sanguíneas , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Tasa de Supervivencia , Resultado del Tratamiento , Remodelación Ventricular
2.
Am J Physiol Heart Circ Physiol ; 311(3): H545-54, 2016 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-27371682

RESUMEN

The spatial variation in restitution properties in relation to varying stimulus site is poorly defined. This study aimed to investigate the effect of varying stimulus site on apicobasal and transmural activation time (AT), action potential duration (APD) and repolarization time (RT) during restitution studies in the intact human heart. Ten patients with structurally normal hearts, undergoing clinical electrophysiology studies, were enrolled. Decapolar catheters were placed apex to base in the endocardial right ventricle (RVendo) and left ventricle (LVendo), and an LV branch of the coronary sinus (LVepi) for transmural recording. S1-S2 restitution protocols were performed pacing RVendo apex, LVendo base, and LVepi base. Overall, 725 restitution curves were analyzed, 74% of slopes had a maximum slope of activation recovery interval (ARI) restitution (Smax) > 1 (P < 0.001); mean Smax = 1.76. APD was shorter in the LVepi compared with LVendo, regardless of pacing site (30-ms difference during RVendo pacing, 25-ms during LVendo, and 48-ms during LVepi; 50th quantile, P < 0.01). Basal LVepi pacing resulted in a significant transmural gradient of RT (77 ms, 50th quantile: P < 0.01), due to loss of negative transmural AT-APD coupling (mean slope 0.63 ± 0.3). No significant transmural gradient in RT was demonstrated during endocardial RV or LV pacing, with preserved negative transmural AT-APD coupling (mean slope -1.36 ± 1.9 and -0.71 ± 0.4, respectively). Steep ARI restitution slopes predominate in the normal ventricle and dynamic ARI; RT gradients exist that are modulated by the site of activation. Epicardial stimulation to initiate ventricular activation promotes significant transmural gradients of repolarization that could be proarrhythmic.


Asunto(s)
Potenciales de Acción/fisiología , Endocardio/fisiología , Sistema de Conducción Cardíaco/fisiología , Ventrículos Cardíacos , Corazón/fisiología , Función Ventricular , Adulto , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miocardio
3.
Europace ; 18(8): 1187-93, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26566940

RESUMEN

AIMS: The Goldenberg risk score, comprising five clinical risk factors (New York Heart Association class >2, atrial fibrillation, QRS duration >120 ms, age >70 years, and urea >26 mg/dL), may help identify patients in whom the survival benefit of the defibrillator may be limited. We aim at assessing whether this score can accurately predict the long-term all-cause mortality risk of patients receiving cardiac resynchronization therapy (CRT) and identify those who are more likely to benefit from the defibrillator. METHODS AND RESULTS: In this retrospective observational cohort study, 638 patients with ischaemic or non-ischaemic dilated cardiomyopathy who had CRT-defibrillator (CRT-D) (n = 224) vs. CRT-pacemaker (CRT-P) (n = 414) implantation were prospectively followed up for survival outcomes. The long-term outcome of patients with CRT-D vs. CRT-P was compared within risk score categories and in patients with severe renal dysfunction. Mean follow-up in surviving and deceased patients was 62.7 and 32.5 months, respectively. This score showed higher discriminative performance in all-cause mortality prediction in CRT-D vs. CRT-P patients (area under the curve 0.718 ± 0.041 vs. 0.650 ± 0.032, respectively, P = 0.001). In those with scores 0-2, a CRT-D device decreased mortality rates in the first 4 years of follow-up compared with CRT-P (11.3 vs. 24.7%, P = 0.041), but this effect attenuated with longer follow-up duration (21.2 vs. 32.7%, P = 0.078). In this group, the benefit of CRT-D during the follow-up was seen after adjusting for traditional mortality predictors (hazard ratio 0.339, P = 0.001). No significant differences in mortality rates were seen in patients with score ≥3 (57.9% with CRT-D vs. 56.9%, P = 0.8) and those with severe renal dysfunction (92.9% in CRT-D vs. 76.2%, P = 0.17). Similar results were seen following propensity score matching. CONCLUSION: A simple risk stratification score comprising five clinical risk factors may help identify CRT patients who are more likely to benefit from the presence of the defibrillator.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Anciano , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Resultado del Tratamiento , Reino Unido , Función Ventricular Izquierda
4.
Circ Arrhythm Electrophysiol ; 8(5): 1017-29, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26082515

RESUMEN

BACKGROUND: Ablation of complex fractionated atrial electrograms (CFAEs) has been proposed as a strategy to improve outcomes in atrial fibrillation (AF) catheter ablation, but the use of this technique remains contentious. We aimed to assess the impact of CFAE ablation in addition to pulmonary vein isolation (PVI) in patients undergoing ablation for AF. METHODS AND RESULTS: We performed a random effects meta-analysis of studies comparing PVI versus PVI+CFAE ablation. The outcomes of freedom from AF/atrial tachycardia after 1 or several ablation procedures and acute procedural-related complications were assessed. Studies were searched on MEDLINE, EMBASE, COCHRANE, and clinicaltrials.gov, and sensitivity analyses were performed. Thirteen studies including a total of 1415 patients were considered eligible. Additional ablation of CFAEs resulted in no improvement in mid-term procedural outcome or freedom from AF or atrial tachycardia (odds ratio [OR], 0.80; 95% confidence interval [CI], 0.58-1.10; P=0.17). Sensitivity analysis of 398 paroxysmal AF ablation procedures showed no incremental benefit of CFAE ablation (OR, 0.80; 95% CI, 0.46-1.38; P=0.42). PVI+CFAE ablation versus PVI alone did not improve the overall rate of freedom from AF or atrial tachycardia in patients with persistent AF (OR, 1.01; 95% CI, 0.63-1.64; P=0.96) or longstanding persistent AF (OR, 0.84; 95% CI, 0.24-2.96; P=0.79). There was no increase in procedural-related adverse events (OR, 1.06; 95% CI, 0.41-2.75; P=0.91). CONCLUSIONS: Despite the apparent safety of this technique, CFAE ablation did not improve freedom from AF/atrial tachycardia in patients with paroxysmal or persistent AF. The role of CFAE ablation in addition to PVI should be questioned and other alternatives assessed to improve the outcome of AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Cirugía Asistida por Computador/métodos , Fibrilación Atrial/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/cirugía , Humanos , Complicaciones Posoperatorias , Resultado del Tratamiento
5.
Eur J Heart Fail ; 16(11): 1206-13, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25302484

RESUMEN

AIMS: Optimal delivery of CRT requires appropriate patient selection and device implantation. Echocardiographic predictors of CRT response individually appear to enhance patient selection, but do not fully reflect the complex underlying myocardial dysfunction. We hypothesized that a multiparametric approach would offer greater predictive value and sought to derive a score incorporating baseline characteristics including: dyssynchrony, LV function, and LV lead position. METHODS AND RESULTS: Data were analysed from 294 patients undergoing CRT between June 2008 and December 2012. All patients were in sinus rhythm with QRS >120 ms, NYHA class II-IV, and LVEF <35%. Detailed clinical assessment including echocardiography was completed at baseline and 6 months after CRT. Response was defined as a ≥15% reduction in LV end-systolic volume. Dyssynchrony (interventricular delay and radial strain delay), global longitudinal strain, and LV lead position were independent predictors of LV remodelling and were used to derive a predictive score which correlated with reduction in LV volume (r = - 0.5, P < 0.001) and was higher with QRS >150 ms and non-ischaemic aetiology. A cut-off score <0.6 offered the highest specificity and positive predictive value (100%) to determine non-response. A score >3.28 offered high specificity (specificity 86%, sensitivity 70%) to predict response. Survival proportion at longer term follow-up was low (21%) in the group with predictive score <0.6. CONCLUSION: A multiparametric strategy, which defines anticipated probability of response to CRT, offers potential to predict non-responders with poor long-term survival following CRT. The value of this approach in avoiding unnecessary device implantation with potential for harm requires validation in large multicentre studies.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Remodelación Ventricular/fisiología , Anciano , Ecocardiografía , Femenino , Humanos , Masculino , Selección de Paciente , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Sensibilidad y Especificidad , Análisis de Supervivencia , Resultado del Tratamiento
6.
JACC Heart Fail ; 2(3): 205-12, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24952685

RESUMEN

OBJECTIVES: This study was conducted to assess the impact of left ventricular (LV) lead position on longer-term survival after cardiac resynchronization therapy (CRT). BACKGROUND: An optimal LV lead position in CRT is associated with improved clinical outcome. A strategy of speckle-tracking echocardiography can be used to guide the implanter to the site of latest activation and away from segments of low strain amplitude (scar). Long-term, prospective survival data according to LV lead position in CRT are limited. METHODS: Data from a follow-up registry of 250 consecutive patients receiving CRT between June 2008 and July 2010 were studied. The study population comprised patients recruited to the derivation group and the subsequent TARGET (Targeted Left Ventricular Lead Placement to guide Cardiac Resynchronization Therapy) randomized, controlled trial. Final LV lead position was described, in relation to the pacing site determined by pre-procedure speckle-tracking echocardiography, as optimal (concordant/adjacent) or suboptimal (remote). All-cause mortality was recorded at follow-up. RESULTS: An optimal LV lead position (n = 202) conferred LV remodeling response superior to that of a suboptimal lead position (change in LV end-systolic volume: -24 ± 15% vs. -12 ± 17% [p < 0.001]; change in ejection fraction: +7 ± 8% vs. +4 ± 7% [p = 0.02]). During long-term follow-up (median: 39 months; range: <1 to 61 months), an optimal LV lead position was associated with improved survival (log-rank p = 0.003). A suboptimal LV lead placement independently predicted all-cause mortality (hazard ratio: 1.8; p = 0.024). CONCLUSIONS: An optimal LV lead position at the site of latest mechanical activation, avoiding low strain amplitude (scar), was associated with superior CRT response and improved survival that persisted during follow-up.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Implantación de Prótesis/métodos , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Ecocardiografía/métodos , Ecocardiografía/mortalidad , Electrodos , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Implantación de Prótesis/mortalidad , Ultrasonografía Intervencional/métodos , Ultrasonografía Intervencional/mortalidad , Remodelación Ventricular/fisiología
7.
Heart ; 100(10): 794-9, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24691411

RESUMEN

OBJECTIVE: Studies have shown beneficial effects of cardiac resynchronisation therapy (CRT) on mortality among patients with heart failure. However the incremental benefits in survival from CRT with a defibrillator (CRT-D) are unclear. The choice of appropriate device remains unanswered. METHOD: This is a single-centre observational study in a tertiary cardiac centre. Patients (n=500) implanted with a CRT device with pacing alone (CRT-P) (n=354) and CRT-D (n=146) were followed for at least 2 years (mean 29 months, SD 14 months). The primary end point was all-cause mortality. RESULTS: A total of 116 deaths (23.2%) were recorded: 88 (24.8%) and 28 (19.2%), in the CRT-P and CRT-D groups, respectively. At 1 year there was a trend favouring CRT-D (HR 0.54, 95% CI 0.27 to 1.07, p=0.08) but this was attenuated by the 2nd year and became insignificant at the end of follow-up (HR 0.76, 95% CI 0.50 to 1.170, p=0.21). There was no survival benefit from having an internal cardioverter-defibrillator if patients were deemed non-responders to CRT. 27% of the CRT-P patients with ischaemic cardiomyopathy met indications for potential internal cardioverter-defibrillator implantation for primary prevention. These were older patients with poorer baseline function in comparison with CRT-D patients with devices for primary prevention. Once these differences were adjusted for, there was no difference in outcome between the groups. CONCLUSIONS: CRT-D did not offer additional survival advantage over CRT-P at longer-term follow-up, as the clinical benefit of a defibrillator attenuated with time. Further work is needed to define which subset of patients benefit from CRT-D.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Función Ventricular Izquierda/fisiología , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Reino Unido/epidemiología
8.
Circ Cardiovasc Imaging ; 6(2): 177-84, 2013 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-23363579

RESUMEN

BACKGROUND: Dyssynchrony assessment based on the timing of regional contraction is inherently independent of underlying myocardial contractility. We tested the hypothesis that patient selection for cardiac resynchronization therapy (CRT) would be enhanced using a parameter derived from the net radial strain delay (RSD) for the 12 basal and mid-left ventricular segments (calculated radial strain delay RSD [RSDc]), based on not only timing but also amplitude of segmental strain. METHODS AND RESULTS: Echocardiographic data were analyzed in 240 patients with symptomatic heart failure undergoing CRT (New York Heart Association class III/IV; QRS >120 milliseconds; ejection fraction, 23±7%). RSDc was calculated as the sum of difference between peak radial strain and radial strain at aortic valve closure before CRT implantation. CRT response was defined as >15% reduction in left ventricular end-systolic volume at 6 months. In a derivation group (n=102), RSDc was higher in responders compared with nonresponders (74±39% versus 29±15%; P<0.001) and related to the change in left ventricular end-systolic volume (r=-0.53; P<0.001). RSDc >40% predicted remodeling (sensitivity, 87%; specificity, 88%). In the validation group (n=108), RSDc similarly predicted response (sensitivity, 89%; specificity, 84%). Survival at long-term follow-up was greater in patients with RSDc >40% (P<0.0001). CONCLUSIONS: RSDc, based on both the timing and the amplitude of segmental strain, has a strong predictive value for CRT remodeling response and long-term survival.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Contracción Miocárdica , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda , Remodelación Ventricular , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Ecocardiografía Doppler , Estudios de Factibilidad , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Estimación de Kaplan-Meier , Valor Predictivo de las Pruebas , Recuperación de la Función , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad , Estrés Mecánico , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/fisiopatología
9.
J Am Coll Cardiol ; 59(17): 1509-18, 2012 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-22405632

RESUMEN

OBJECTIVES: This study sought to assess the impact of targeted left ventricular (LV) lead placement on outcomes of cardiac resynchronization therapy (CRT). BACKGROUND: Placement of the LV lead to the latest sites of contraction and away from the scar confers the best response to CRT. We conducted a randomized, controlled trial to compare a targeted approach to LV lead placement with usual care. METHODS: A total of 220 patients scheduled for CRT underwent baseline echocardiographic speckle-tracking 2-dimensional radial strain imaging and were then randomized 1:1 into 2 groups. In group 1 (TARGET [Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy]), the LV lead was positioned at the latest site of peak contraction with an amplitude of >10% to signify freedom from scar. In group 2 (control) patients underwent standard unguided CRT. Patients were classified by the relationship of the LV lead to the optimal site as concordant (at optimal site), adjacent (within 1 segment), or remote (≥2 segments away). The primary endpoint was a ≥15% reduction in LV end-systolic volume at 6 months. Secondary endpoints were clinical response (≥1 improvement in New York Heart Association functional class), all-cause mortality, and combined all-cause mortality and heart failure-related hospitalization. RESULTS: The groups were balanced at randomization. In the TARGET group, there was a greater proportion of responders at 6 months (70% vs. 55%, p = 0.031), giving an absolute difference in the primary endpoint of 15% (95% confidence interval: 2% to 28%). Compared with controls, TARGET patients had a higher clinical response (83% vs. 65%, p = 0.003) and lower rates of the combined endpoint (log-rank test, p = 0.031). CONCLUSIONS: Compared with standard CRT treatment, the use of speckle-tracking echocardiography to the target LV lead placement yields significantly improved response and clinical status and lower rates of combined death and heart failure-related hospitalization. (Targeted Left Ventricular Lead Placement to Guide Cardiac Resynchronization Therapy [TARGET] study); ISRCTN19717943).


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Causas de Muerte , Ecocardiografía/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valores de Referencia , Medición de Riesgo , Índice de Severidad de la Enfermedad , Método Simple Ciego , Volumen Sistólico , Tasa de Supervivencia , Resultado del Tratamiento , Reino Unido , Remodelación Ventricular/fisiología
10.
Heart ; 98(5): 408-13, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21561896

RESUMEN

BACKGROUND: Glucagon-like peptide-1 (GLP-1) is an incretin hormone which has been shown to promote myocardial glucose uptake. Its pharmacological properties as a cardioprotective agent are attractive because it has a short half-life and there is minimal risk of hypoglycaemia. OBJECTIVE: To assess the hypothesis that intravenous infusion of GLP-1 would protect the heart from ischaemic left ventricular (LV) dysfunction during dobutamine stress echocardiography (DSE) in patients with coronary artery disease (CAD). DESIGN: Randomised crossover study. PATIENTS AND INTERVENTIONS: 14 patients with CAD and good LV function awaiting revascularisation underwent two DSE scans in a randomised order. GLP-1 was infused intravenously at 1.2 pmol/kg/min starting 30 min before the DSE for one of the scans and the other scan acted as a control. MAIN OUTCOME MEASUREMENTS: Global and regional wall LV function assessed using tissue Doppler imaging at rest, peak stress and 30 min into recovery. RESULTS: Global LV function was greater at peak stress during GLP-1 infusion compared with control (ejection fraction 77.0±4.4 vs 70.8±5.0%, p<0.0001; mitral annular systolic velocity 12.18±3.10 vs 11.31±3.11 cm/s, p=0.0004). GLP-1 infusion improved regional wall LV function in 12 non-apical segments assessed by velocity, strain and strain rate. This beneficial effect was predominantly seen in ischaemic segments. In recovery, infusion of GLP-1 mitigated the post-ischaemic stunning seen in the control scan. CONCLUSION: Intravenous infusion of GLP-1 protects the heart from ischaemic LV dysfunction induced by dobutamine stress in patients with CAD. CLINICAL TRIAL REGISTRATION: URL: http://isrctn.org. REGISTRATION NUMBER: ISRCTN 69686930.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria/efectos de los fármacos , Dobutamina/efectos adversos , Ecocardiografía de Estrés/métodos , Péptido 1 Similar al Glucagón/uso terapéutico , Daño por Reperfusión Miocárdica/prevención & control , Cardiotónicos/efectos adversos , Enfermedad de la Arteria Coronaria/fisiopatología , Estudios Cruzados , Ecocardiografía de Estrés/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Daño por Reperfusión Miocárdica/etiología , Daño por Reperfusión Miocárdica/fisiopatología , Pronóstico , Estudios Prospectivos
11.
Pacing Clin Electrophysiol ; 34(11): 1527-36, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21797899

RESUMEN

AIMS: Noninvasive cardiac output (CO) measurement (NICOM) is a novel method to assess ventricular function and offers a potential alternative for optimization of cardiac resynchronization therapy (CRT) devices. We compared the effect of NICOM-based optimization to no optimization (empiric settings) on CRT outcomes. METHODS: Two hundred and three patients undergoing CRT were assessed in two consecutive nonrandomized groups; an empiric group (n = 54) was programmed to "out of the box" settings with a fixed AV delay of 120 ms and a VV delay of 0 ms; and the optimization group (n = 149) underwent adjustments of both the AV and VV delays according to the greatest improvement in resting CO. The primary endpoints were improvements in left ventricular (LV) volumes and function from baseline at 6 months. Secondary endpoints were change in New York Heart Association (NYHA) class, quality of life score, and 6-minute walk test (6 MWT) performance. RESULTS: After 6 months of CRT, the optimization group had a better clinical response with lower NYHA class (2.1 ± 0.8 vs 2.4 ± 0.8, P = 0.048) and quality of life scores (35 ± 18 vs 42 ± 20, P = 0.045) but no differences in 6-MWT performance (269 ± 110 vs 277 ± 114 m, P = 0.81). Echocardiographic response was also better in the optimization group with lower LV end systolic volume (108 ± 51 vs 126 ± 60 mL, P = 0.048) and higher ejection fraction (30 ± 7 vs 27 ± 8, P = 0.01) compared to empiric settings. CONCLUSION: Device optimization using noninvasive measures of CO is associated with better clinical and echocardiographic response compared to empiric settings.


Asunto(s)
Gasto Cardíaco , Terapia de Resincronización Cardíaca/métodos , Cardiografía de Impedancia/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/prevención & control , Anciano , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones
12.
Circ Cardiovasc Interv ; 4(3): 266-72, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21586690

RESUMEN

BACKGROUND: The incretin hormone glucagon-like peptide-1 (GLP-1) has been shown to have cardioprotective properties in animal models of ischemia and infarction due to promotion of myocardial glucose uptake and suppression of apoptosis. We investigated whether GLP-1 protected the heart from dysfunction caused by supply ischemia during percutaneous coronary intervention (PCI). METHODS AND RESULTS: Twenty patients with normal left ventricular (LV) function and single-vessel coronary disease within the left anterior descending artery undergoing elective PCI were studied. A conductance catheter was placed into the LV through the femoral artery, and pressure-volume loops were recorded at baseline and during a 1-minute low-pressure balloon occlusion at the site of the stenosis. The patients were randomized to receive an infusion of either GLP-1(7-36) amide at 1.2 pmol/kg per minute or saline immediately after the first balloon occlusion. Coronary balloon occlusion caused LV stunning in the control group with cumulative LV dysfunction on subsequent occlusion that was not seen in the GLP-1 group. GLP-1 improved recovery of LV systolic and diastolic function at 30 minutes after balloon occlusion compared with control (delta dP/dt(max) from baseline, -1.6% versus -12.2%; P=0.02) and reduced the LV dysfunction after the second balloon occlusion (delta dP/dt(max), -13.1% versus -25.3%; P=0.01). CONCLUSIONS: In this pilot study, infusion of GLP-1 has been demonstrated to reduce ischemic LV dysfunction after supply ischemia during coronary balloon occlusion in humans and mitigates stunning. The findings require confirmation in a larger scale clinical trial. CLINICAL TRIAL REGISTRATION: URL: http://www.isrctn.org. Unique identifier: ISRCTN 77442023.


Asunto(s)
Péptido 1 Similar al Glucagón/uso terapéutico , Isquemia Miocárdica/fisiopatología , Daño por Reperfusión Miocárdica/prevención & control , Aturdimiento Miocárdico/prevención & control , Anciano , Angioplastia Coronaria con Balón , Oclusión con Balón/efectos adversos , Ácidos Grasos no Esterificados/sangre , Femenino , Péptido 1 Similar al Glucagón/sangre , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Proyectos Piloto , Función Ventricular Izquierda/efectos de los fármacos
13.
Expert Rev Cardiovasc Ther ; 9(2): 185-97, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21453215

RESUMEN

The number of cardiac resynchronization therapy (CRT) device implantations has been increasing exponentially, with the implant rate doubling over the past few years. While the majority of CRT recipients enjoy symptomatic relief, approximately 30% of individuals reap no benefit and only a minority are rendered completely symptom free. In response, many clinicians engage in the theoretically advantageous process of postimplantation optimization of atrial and ventricular stimulation by altering atrioventricular and interventricular pacing intervals. However, the rationale for routine CRT optimization and the methods of doing so have been the subjects of recent debate. Here, we present an overview of the background, techniques and evidence for CRT optimization.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Corazón/fisiología , Gasto Cardíaco , Dispositivos de Terapia de Resincronización Cardíaca , Medicina Basada en la Evidencia , Humanos , Monitoreo Fisiológico , Guías de Práctica Clínica como Asunto
14.
Europace ; 13(6): 845-52, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21427090

RESUMEN

AIMS: Left ventricular (LV) lead placement to the most delayed segment offers the greatest potential benefit to cardiac resynchronization therapy (CRT). We assessed the impact of interventricular (VV) optimization on acute changes in cardiac output (CO) in patients with and without LV pacing of the most delayed segment. METHODS AND RESULTS: In 124 patients, the most delayed segment was defined by speckle tracking radial strain and the LV lead position by biplane fluoroscopy. Patients were classified as either a concordant (LV lead at latest site), adjacent (within one segment), or remote (two or more segments away) LV lead. Atrioventricular (AV) and VV delays were optimized by echocardiography. Cardiac output was measured non-invasively and a >20% increase in CO from baseline (intrinsic) defined acute response. Changes in CO in patients with concordant, adjacent, or remote LV leads were recorded following atrioventricular optimization alone (AV OPT) and after combined AV and VV optimization (AV/VV OPT). Compared with AV OPT pacing, AV/VV OPT produced a greater rise in CO (5.45 ± 1.1 vs. 5.76 ± 1.2 L/min, P< 0.001) and higher acute response rates (48.4 vs. 61.3%, P= 0.041). In adjacent patients, compared with AV OPT pacing, AV/VV OPT settings increased the response rate from 36.4 to 63.6% (P= 0.037). VV optimization had no effect on acute response rates in patients with remote (26.7 vs. 33.3%, P = 0.581) or concordant LV leads (65.6 vs. 72.1%, P = 0.438). CONCLUSION: VV optimization overcomes some but not all of the deleterious effects of a suboptimal LV lead position.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Hemodinámica/fisiología , Disfunción Ventricular Izquierda/terapia , Anciano , Anciano de 80 o más Años , Gasto Cardíaco/fisiología , Dispositivos de Terapia de Resincronización Cardíaca , Ecocardiografía , Electrodos , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 34(4): 467-74, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21208234

RESUMEN

INTRODUCTION: Left ventricular (LV) lead placement to the latest contracting area (concordant LV lead) is associated with better response to cardiac resynchronization therapy (CRT) compared to a discordant LV lead. However, the effect of the right ventricular (RV) lead site on CRT response is unclear. We investigated the relationship of the RV and LV lead positions on CRT response. METHODS: In 131 CRT patients, the LV lead was positioned preferentially in a lateral or posterolateral vein and the RV lead to either the RV septum (RVS, n = 55) or RV apex (RVA, n = 76). The latest site of contraction was determined with two-dimensional speckle tracking radial strain imaging and patients had a concordant LV lead position if pacing the latest segment, and discordant if not. Response was defined as ≥15% reduction in LV end systolic volume (LVESV) at 6-month follow-up. RESULTS: There were no significant differences in mean reduction of LVESV at follow-up (RVS vs RVA: -23.3 ± 16% vs 22.1 ± 18%, P = 0.70) or rate of responders (58.2% vs 57.9%, P = 0.97) between the two groups. In patients with a concordant LV lead (n = 71), the response rate was significantly higher than those with a discordant lead (76.1% vs 36.7%, P < 0.001). There were no differences in outcomes in patients with a concordant or discordant LV lead according to the RV lead location. CONCLUSION: The extent of LV reverse remodeling following CRT is not related to the RV lead position, but is significantly higher in patients with a concordant LV lead.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Electrodos Implantados , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Implantación de Prótesis/estadística & datos numéricos , Anciano , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos , Humanos , Masculino , Prevalencia , Implantación de Prótesis/métodos , Resultado del Tratamiento , Reino Unido/epidemiología
16.
Circ Cardiovasc Imaging ; 3(2): 195-201, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20075143

RESUMEN

BACKGROUND: Glucagon-like peptide-1 (GLP-1) is an incretin hormone secreted postprandially that promotes myocardial glucose uptake. The active amide GLP-1 (7-36) is degraded by the enzyme DPP-4, and drugs that inhibit this enzyme (such as sitagliptin) have been introduced to treat type 2 diabetes. We assessed the hypothesis that increasing the plasma concentration of GLP-1 by DPP-4 inhibition would protect the heart from ischemic left ventricular (LV) dysfunction during dobutamine stress echocardiography in patients with coronary artery disease. METHODS AND RESULTS: Fourteen patients with coronary artery disease and preserved LV function awaiting revascularization were studied. After either a single dose of 100 mg sitagliptin or placebo, 75 g of glucose was given orally to promote GLP-1 secretion and dobutamine stress echocardiography was conducted with tissue Doppler imaging at rest, peak stress, and 30 minutes. After sitagliptin, plasma GLP-1 (7-36) was increased at peak stress (16.5+/-10.7 versus 9.7+/-8.7 pg/mL; P=0.003) and in recovery (12.4+/-5.5 versus 9.0+/-5.5 pg/mL; P=0.01), and the LV response to stress was enhanced (ejection fraction, 72.6+/-7.2 versus 63.9+/-7.9%, P=0.0001; mitral annular systolic velocity, 12.54+/-3.18 versus 11.49+/-2.52 cm/s; P=0.0006). DPP-4 inhibition also improved LV regional function in the 12 paired nonapical segments assessed by peak systolic tissue Doppler (velocity, 10.56+/-4.49 versus 9.81+/-4.26 cm/s, P=0.002; strain, -15.9+/-6.3 versus -14.6+/-6.6%, P=0.01; strain rate, -2.04+/-1.04 versus -1.75+/-0.98 s(-1), P=0.0003). This was predominantly due to a cardioprotective effect on ischemic segments (velocity in ischemic segments, 9.77+/-4.18 versus 8.74+/-3.87, P=0.007; velocity in nonischemic segments, 11.51+/-4.70 versus 11.14+/-4.38, P=0.14). In recovery, sitagliptin attenuated the postischemic stunning seen after the control study. CONCLUSIONS: The augmentation of GLP-1 (7-36) by inhibition of DPP-4 improves global and regional LV performance in response to stress and mitigates postischemic stunning in humans with coronary artery disease. Clinical Trial Registration- URL: http://www.isrctn.org. Unique identifier: ISRCTN78649100.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Inhibidores de la Dipeptidil-Peptidasa IV/uso terapéutico , Ecocardiografía de Estrés , Péptido 1 Similar al Glucagón/sangre , Aturdimiento Miocárdico/prevención & control , Pirazinas/uso terapéutico , Triazoles/uso terapéutico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/prevención & control , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Fosfato de Sitagliptina
17.
Europace ; 11(12): 1666-74, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19910316

RESUMEN

AIMS: Non-invasive cardiac output monitoring (NICOM) based on bio-reactance offers a portable method to assess ventricular function. Optimization of cardiac resynchronization therapy (CRT) by echocardiography is labour-intensive. We compared the ability of NICOM and echocardiography to facilitate optimum CRT device programming. METHODS AND RESULTS: Forty-seven patients in sinus rhythm were evaluated within 14 days of CRT implantation. The atrio- (AV) and interventricular (VV) delay intervals were incrementally adjusted and at each setting, NICOM and echocardiographic data were recorded. Left ventricular (LV) volumes and function were assessed by echocardiography at baseline and 3 months. Response to CRT was defined as a reduction in LV end-systolic volume (LVESV) by >15%. In all patients, cardiac output (CO) increased significantly at optimized settings compared with baseline (5.66 +/- 1.4 vs. 4.35 +/- 1.1 L/min, P < 0.001). A 20% increase in acute CO following CRT predicted LVESV reduction of >15% with a sensitivity of 81% and specificity of 92% (AUC 0.86). The optimum AV delay determined by NICOM was confirmed by echocardiography in 40 of 47 patients (85%, r = 0.89, P < 0.01) and for VV delay in 39 of 47 patients (83%, r = 0.89, P < 0.01). CONCLUSION: Non-invasive cardiac output monitoring is a simple, reliable, and portable alternative to echocardiography to program CRT devices.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevención & control , Gasto Cardíaco , Pletismografía de Impedancia/métodos , Anciano , Impedancia Eléctrica , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA