Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Biomed Mater Res B Appl Biomater ; 108(7): 2878-2888, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32578348

RESUMEN

The in vitro and in vivo handling and performance characteristics of a small caliber radiopaque embolic microsphere, 40-90 µm DC Bead LUMI™ (LUMI40-90), were studied. Microsphere drug loading and elution and effects on size, suspension, and microcatheter delivery were evaluated using established in vitro methodologies. In vivo evaluations of vascular penetration (rabbit renal artery embolization), long-term biocompatibility and X-ray imaging properties, pharmacokinetics and local tissue effects of both doxorubicin (Dox) and irinotecan (Iri) loaded microspheres (swine hepatic artery embolization) were conducted. Compared to 70-150 µm DC Bead LUMI (LUMI70-150), LUMI40-90 averaged 70 µm versus 100 µm, which was unchanged upon drug loading. Handling, suspension, and microsphere delivery studies were successfully performed. Dox loading was faster (20 min) and Iri equivalent (<10 min) while drug elution rates were similar. Contrast suspension times were longer with no delivery complications. Vascular penetration was statistically greater (rabbit) with no unexpected adverse safety findings (swine). Microspheres ± drug were visible under X-ray imaging (CT) at 90 days. Peak plasma drug levels and area under the curve were greater for LUMI40-90 compared to LUMI70-150 but comparable to 70-150 µm DC BeadM1™ (DC70-150). Local tissue effects showed extensive hepatic necrosis for Dox, whereas Iri displayed lower toxicity with more pronounced lobar fibrosis. LUMI40-90 remains suspended for longer and have greater vessel penetration compared to the other DC Bead LUMI sizes and are similarly highly biocompatible with long-term visibility under X-ray imaging. Drug loading is equivalent or faster with pharmacokinetics similar to DC70-150 for both Dox and Iri.


Asunto(s)
Medios de Contraste , Doxorrubicina , Portadores de Fármacos , Embolización Terapéutica , Irinotecán , Microesferas , Tomografía Computarizada por Rayos X , Animales , Medios de Contraste/química , Medios de Contraste/farmacocinética , Medios de Contraste/farmacología , Doxorrubicina/química , Doxorrubicina/farmacocinética , Doxorrubicina/farmacología , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Portadores de Fármacos/farmacología , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/metabolismo , Irinotecán/química , Irinotecán/farmacocinética , Irinotecán/farmacología , Conejos , Porcinos
2.
Radiology ; 293(3): 695-703, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31617791

RESUMEN

Background Transarterial chemoembolization with cytotoxic drugs is standard treatment for unresectable intermediate-stage hepatocellular carcinoma but achieves suboptimal outcomes because of hypoxic stress and the production of detrimental proangiogenic factors. An alternative approach using radiopaque embolization beads loaded with the antiangiogenic drug vandetanib may provide improved anticancer efficacy. Purpose To evaluate the pharmacokinetics, safety, and efficacy of vandetanib-eluting radiopaque bead (VERB) chemoembolization of rabbit liver tumors. Materials and Methods Between April 2015 and March 2016, 60 New Zealand white rabbits with VX2 liver tumors were randomly treated with VERBs at different doses, with nonloaded radiopaque beads (ROBs), or with intra-arterial vandetanib suspension (VS) or were not treated. Vandetanib plasma concentration and tumor growth at US were evaluated. Animals were euthanized after 3 days or 3 weeks. Assessment included bead distribution at x-ray imaging and histologic examination, tumor viability at histologic examination, and vandetanib tissue concentration. Group comparison analysis (Mann-Whitney, Kruskal-Wallis, and χ2 tests) and predictive factor analysis for tumor growth and viability were performed. Results Vandetanib plasma concentration was lower with VERBs than with VS (P < .01), while concentration in tumor was higher for VERBs (than for VS) at 3 days (median, 29.2 vs 2.74 ng/mg; P = .48). Tumor growth was lower with VERBs than with ROBs and with VS at both time points, with median values of +114%, +192%, and +466% at 3 weeks, respectively. Tumor viability was lower at 3 days for VERBs than for ROBs and for VS (3%, 18%, and 38%, respectively) but was not significantly different at 3 weeks. The volume of bead in tumor was a significant predictive factor for lower tumor growth in multivariable analysis at 3 days (P = .03). Drug tumor concentration was a significant predictive factor for lower tumor growth at 3 weeks (P = .04). Conclusion Vandetanib-eluting radiopaque bead chemoembolization showed a pharmacokinetic advantage over intra-arterial drug administration in a preclinical model of liver cancer. High deposition of beads and high vandetanib concentration in tumor led to stronger antitumor effects. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Kim and Van den Abbeele in this issue.


Asunto(s)
Quimioembolización Terapéutica , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Neoplasias Hepáticas Experimentales/tratamiento farmacológico , Piperidinas/farmacología , Quinazolinas/farmacología , Animales , Tomografía Computarizada de Haz Cónico , Microesferas , Piperidinas/farmacocinética , Quinazolinas/farmacocinética , Conejos
3.
Theranostics ; 9(19): 5626-5641, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31534507

RESUMEN

There are currently two methods widely used in clinical practice to perform transarterial chemoembolization (TACE). One is based on mixing an aqueous drug with an iodized oil (Lipiodol) and creating an emulsion that is delivered intraarterially, followed by embolization with a particulate agent. The other is based on a one-step TACE using Drug-eluting Beads (DEBs) loaded with drug. It is not recommended to mix Lipiodol with DEBs due to incompatibility. For the first time, novel DEB: Lipiodol: doxorubicin (Dox) emulsions are identified using lyophilized polyvinyl alcohol (PVA) hydrogels (non-iodinated or iodinated) DEBs. METHODS: 15 DEB emulsions (50mg Dox) were assessed for stability and deliverability in vitro and in vivo in a swine model. Dox release from selected formulations was measured in vitro using a vascular flow model and in vivo in a VX2 rabbit tumor model. RESULTS: Both DEB formats were shown to be able to form emulsions, however only Iodinated DEBs consistently met defined handling criteria. Those based on the non-iodinated DEB achieved >99%+ Dox loading in <5 minutes but were generally less stable. Those prepared using iodinated DEBs, which are more hydrophobic, were able to form stable Pickering-like emulsions (separation time ≥ 20 minutes) and demonstrated handling, administration and imaging observations more akin to Lipiodol™ TACE emulsions in both embolization models. Controlled Dox release and hence beneficial in vivo pharmacokinetics associated with DEB-TACE were maintained. CONCLUSIONS: This study demonstrates that it is possible to formulate novel DEB emulsions suitable for TACE that combine positive elements of both Lipiodol™ based and DEB-TACE procedures.


Asunto(s)
Quimioembolización Terapéutica , Doxorrubicina/administración & dosificación , Sistemas de Liberación de Medicamentos/métodos , Aceite Etiodizado/química , Animales , Doxorrubicina/química , Sistemas de Liberación de Medicamentos/instrumentación , Emulsiones/administración & dosificación , Emulsiones/química , Aceite Etiodizado/administración & dosificación , Femenino , Masculino , Conejos , Porcinos
4.
Eur J Pharm Sci ; 136: 104943, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31152772

RESUMEN

Drug-eluting Embolic Bead - Transarterial Chemoembolisation (DEB-TACE) is a minimally invasive embolising treatment for liver tumours that allows local release of chemotherapeutic drugs via ion exchange, following delivery into hepatic arterial vasculature. Thus far, no single in vitro model has been able to accurately predict the complete kinetics of drug release from DEB, due to heterogeneity of rate-controlling mechanisms throughout the process of DEB delivery. In this study, we describe two in vitro models capable of distinguishing between early phase and late phase drug release by mimicking in vivo features of each phase. First, a vascular flow system (VFS) was used to simulate the early phase by delivering DEB into a silicon vascular cast under high pulsatile flow. This yielded a burst release profile of drugs from DEB which related to the dose adjusted Cmax observed in pharmacokinetic plasma profiles from a preclinical swine model. Second, an open loop flow-through cell system was used to model late phase drug release by packing beads in a column with an ultra-low flow rate. DEB loaded with doxorubicin, irinotecan and vandetanib showed differential drug release rates due to their varying chemical properties and unique drug-bead interactions. Using more representative in vitro models to map discrete phases of DEB drug release will provide a better capability to predict the pharmacokinetics of developmental formulations, which has implications for treatment safety and efficacy.


Asunto(s)
Doxorrubicina/farmacocinética , Liberación de Fármacos/fisiología , Irinotecán/farmacocinética , Piperidinas/farmacocinética , Quinazolinas/farmacocinética , Animales , Quimioembolización Terapéutica/métodos , Sistemas de Liberación de Medicamentos/métodos , Técnicas In Vitro , Hígado/efectos de los fármacos , Hígado/metabolismo , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/metabolismo , Porcinos
5.
J Mech Behav Biomed Mater ; 78: 46-55, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29132100

RESUMEN

The purpose of this study was to evaluate LC Bead LUMI™ (40-90µm and 70-150µm) in order to determine if their increased resistance to compression influences microsphere penetration and distribution compared to more compressible commercial microspheres. LC Bead LUMI™ 40-90µm and 70-150µm, LC BeadM1® 70-150µm, Embozene™ 40µm and Embozene™ 100µm size and distributions were measured using optical microscopy. Penetration in vitro was evaluated using an established 'plate model', consisting of a calibrated tapered gap between a glass plate and plastic housing to allow visual observation of microsphere penetration depth. Behaviour in vivo was assessed using a rabbit renal embolization model with histopathologic confirmation of vessel penetration depth. Penetration behaviour in vitro was reproducible and commensurate with the measured microsphere size, the smaller the microsphere the deeper the penetration. Comparison of the microsphere diameter measured on the 2D plate model versus the corresponding average microsphere size measured by histopathology in the kidney showed no significant differences (p = > 0.05 Mann-Whitney, demonstrating good in vitro - in vivo predictive capabilities of the plate model) confirming predictable performance for LC Bead LUMI™ (40-90µm and 70-150µm) based on microsphere size, their increased rigidity having no bearing on their depth of penetration and distribution. An assessment of a LC Bead LUMI™ (40-90µm and 70-150µm) has shown that despite having greater resistance to compression, these microspheres behave in a predictable manner within in vitro and in vivo models comparable with more compressible microspheres of similar sizes.


Asunto(s)
Fuerza Compresiva , Microesferas , Animales , Transporte Biológico , Embolización Terapéutica , Vidrio/química , Riñón/citología , Riñón/metabolismo , Ensayo de Materiales , Conejos
6.
Theranostics ; 7(8): 2164-2176, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28740542

RESUMEN

PURPOSE: To evaluate the plasma and tissue pharmacokinetics, safety and toxicity following intra-arterial hepatic artery administration of Vandetanib (VTB)-eluting Radiopaque Beads (VERB) in healthy swine. MATERIALS AND METHODS: In a first phase, healthy swine were treated with hepatic intra-arterial administration of VERB at target dose loading strengths of 36 mg/mL (VERB36), 72 mg/mL (VERB72) and 120 mg/mL (VERB120). Blood and tissue samples were taken and analysed for VTB and metabolites to determine pharmacokinetic parameters for the different dose forms over 30 days. In a second phase, animals were treated with unloaded radiopaque beads or high dose VTB loaded beads (VERB100, 100 mg/mL). Tissue samples from embolized and non-embolized areas of the liver were evaluated at necropsy (30 and 90 days) for determination of VTB and metabolite levels and tissue pathology. Imaging was performed prior to sacrifice using multi-detector computed tomography (MDCT) and imaging findings correlated with pathological changes in the tissue and location of the radiopaque beads. RESULTS: The peak plasma levels of VTB (Cmax) released from the various doses of VERB ranged between 6.19-17.3 ng/mL indicating a low systemic burst release. The plasma profile of VTB was consistent with a distribution phase up to 6 h after administration followed by elimination with a half-life of 20-23 h. The AUC of VTB and its major metabolite N-desmethyl vandetanib (NDM VTB) was approximately linear with the dose strength of VERB. VTB plasma levels were at or below limits of detection two weeks after administration. In liver samples, VTB and NDM VTB were present in treated sections at 30 days after administration at levels above the in vitro IC50 for biological effectiveness. At 90 days both analytes were still present in treated liver but were near or below the limit of quantification in untreated liver sections, demonstrating sustained release from the VERB. Comparison of the reduction of the liver lobe size and associated tissue changes suggested a more effective embolization with VERB compared to the beads without drug. CONCLUSIONS: Hepatic intra-arterial administration of VERB results in a low systemic exposure and enables sustained delivery of VTB to target tissues following embolization. Changes in the liver tissue are consistent with an effective embolization and this study has demonstrated that VERB100 is well tolerated with no obvious systemic toxicity.


Asunto(s)
Medios de Contraste/efectos adversos , Medios de Contraste/farmacocinética , Embolización Terapéutica/métodos , Hígado/patología , Piperidinas/efectos adversos , Piperidinas/farmacocinética , Quinazolinas/efectos adversos , Quinazolinas/farmacocinética , Animales , Medios de Contraste/administración & dosificación , Inyecciones Intraarteriales , Hígado/diagnóstico por imagen , Modelos Animales , Piperidinas/administración & dosificación , Quinazolinas/administración & dosificación , Radiografía Abdominal , Porcinos , Tomografía Computarizada por Rayos X
7.
Biomaterials ; 103: 293-304, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27419364

RESUMEN

The objective of this study was to undertake a comprehensive long-term biocompatibility and imaging assessment of a new intrinsically radiopaque bead (LC Bead LUMI™) for use in transarterial embolization. The sterilized device and its extracts were subjected to the raft of ISO10993 biocompatibility tests that demonstrated safety with respect to cytotoxicity, mutagenicity, blood contact, irritation, sensitization, systemic toxicity and tissue reaction. Intra-arterial administration was performed in a swine model of hepatic arterial embolization in which 0.22-1 mL of sedimented bead volume was administered to the targeted lobe(s) of the liver. The beads could be visualized during the embolization procedure with fluoroscopy, DSA and single X-ray snapshot imaging modalities. CT imaging was performed before and 1 h after embolization and then again at 7, 14, 30 and 90 days. LC Bead LUMI™ could be clearly visualized in the hepatic arteries with or without administration of IV contrast and appeared more dense than soluble contrast agent. The CT density of the beads did not deteriorate during the 90 day evaluation period. The beads embolized predictably and effectively, resulting in areas devoid of contrast enhancement on CT imaging suggesting ischaemia-induced necrosis nearby the sites of occlusion. Instances of off target embolization were easily detected on imaging and confirmed pathologically. Histopathology revealed a classic foreign body response at 14 days, which resolved over time leading to fibrosis and eventual integration of the beads into the tissue, demonstrating excellent long-term tissue compatibility.


Asunto(s)
Embolización Terapéutica/métodos , Hemostáticos/uso terapéutico , Nanopartículas/uso terapéutico , Radiografía Intervencional/métodos , Animales , Materiales Biocompatibles/efectos adversos , Materiales Biocompatibles/síntesis química , Medios de Contraste/efectos adversos , Medios de Contraste/síntesis química , Embolización Terapéutica/efectos adversos , Hemostáticos/efectos adversos , Hemostáticos/química , Nanopartículas/efectos adversos , Nanopartículas/ultraestructura , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Porcinos , Nanomedicina Teranóstica/métodos
8.
Toxicol Sci ; 131(1): 311-24, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22977166

RESUMEN

Erythrocyte-encapsulated thymidine phosphorylase (EE-TP) is currently under development as an enzyme replacement therapy for mitochondrial neurogastrointestinal encephalomyopathy (MNGIE), an autosomal recessive disorder caused by a deficiency of thymidine phosphorylase. The rationale for the development of EE-TP is based on the pathologically elevated metabolites (thymidine and deoxyuridine) being able to freely diffuse across the erythrocyte membrane where the encapsulated enzyme catalyses their metabolism to the normal products. The systemic toxic potential of EE-TP was assessed when administered intermittently by iv bolus injection to BALB/c mice and Beagle dogs for 4 weeks. The studies consisted of one control group receiving sham-loaded erythrocytes twice weekly and two treated groups, one dosed once every 2 weeks and the other dosed twice per week. The administration of EE-TP to BALB/c mice resulted in thrombi/emboli in the lungs and spleen enlargement. These findings were also seen in the control group, and there was no relationship to the number of doses administered. In the dog, transient clinical signs were associated with EE-TP administration, suggestive of an immune-based reaction. Specific antithymidine phosphorylase antibodies were detected in two dogs and in a greater proportion of mice treated once every 2 weeks. Nonspecific antibodies were detected in all EE-TP-treated animals. In conclusion, these studies do not reveal serious toxicities that would preclude a clinical trial of EE-TP in patients with MNGIE, but caution should be taken for infusion-related reactions that may be related to the production of nonspecific antibodies or a cell-based immune response.


Asunto(s)
Portadores de Fármacos , Terapia de Reemplazo Enzimático , Eritrocitos , Seudoobstrucción Intestinal/tratamiento farmacológico , Encefalomiopatías Mitocondriales/tratamiento farmacológico , Timidina Fosforilasa/toxicidad , Pruebas de Toxicidad/métodos , Animales , Transfusión de Sangre Autóloga , Perros , Portadores de Fármacos/química , Evaluación Preclínica de Medicamentos , Transfusión de Eritrocitos , Eritrocitos/química , Seudoobstrucción Intestinal/enzimología , Ratones , Ratones Endogámicos BALB C , Encefalomiopatías Mitocondriales/enzimología , Distrofia Muscular Oculofaríngea , Oftalmoplejía/congénito , Timidina Fosforilasa/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA