Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Interv Neuroradiol ; : 15910199241284792, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39311026

RESUMEN

PURPOSE: Contact aspiration mechanical thrombectomy (CAMT) with 0.088-inch catheters may improve first-pass success rates, but delivery of such catheters can be challenging and limit effectiveness. This study examines the initial multicenter experience using the FreeClimb 88 catheter paired with the Tenzing 8 delivery catheter. MATERIALS AND METHODS: Retrospective analysis was performed of consecutive patients with large vessel occlusion (LVO) of the internal carotid artery (ICA) or M1 segment of the middle cerebral artery treated with off-label CAMT using the FreeClimb 88 and Tenzing 8 at eight sites participating in the early limited release for these devices. Demographic and procedural variables were collected and analyzed with descriptive statistics and multivariable analysis. RESULTS: Fifty-three consecutive patients were treated. Large vessel occlusion was located in the ICA in 19/53 (35.8%) patients; 34/53 (64.2%) were in the M1 segment. FreeClimb 88 was successfully delivered to the site of occlusion in 50/53 (94.3%) of patients. First-pass TICI 2c or 3 was achieved with FreeClimb 88 delivered by Tenzing 8 in 36 (67.9%) cases. Among cases with successful FreeClimb 88 delivery 9/50 (18.0%) required additional smaller devices to perform thrombectomy of distal occlusions after recanalization of the initial LVO. No complications or symptomatic hemorrhages occurred following thrombectomy. CONCLUSION: Contact aspiration mechanical thrombectomy performed for ICA or M1 LVOs using FreeClimb 88 delivered with Tenzing 8 was safe, effective, and efficient in this early experience, with first-pass TICI 2c or 3 was achieved in 68% of patients without procedural complications occurring in any cases.

2.
Interv Neuroradiol ; : 15910199231216765, 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38018024

RESUMEN

INTRODUCTION: Aspiration mechanical thrombectomy traditionally includes use of an inner microcatheter and leading microwire to navigate an aspiration catheter (AC) to the site of occlusion. Early clinical experience suggests that a leading microwire is often not needed with the Tenzing 7 (T7, Route 92 Medical, San Mateo, CA), a soft tapered tip ledge-reducing delivery catheter. This multicenter experience aims to describe AC delivery success in single-pass thrombectomy using T7 with and without a leading microwire. METHODS: A retrospective review was conducted of consecutive patients who underwent single-pass thrombectomy with T7 at six institutions between 2020 and 2022. We examined the percentage of successful AC delivery, puncture-to-revascularization time, and procedural complication rate. RESULTS: A leading microwire with T7 was used in 19/89 (21%) of patients, and it was not used with T7 in 70/89 (79%) of patients. Successful AC delivery was similar with and without microwires (97% vs. 90%, p = 0.15). Median puncture-to-revascularization times were similar (17 min microwire vs. 16 min no-microwire, p = 0.12). No complications were associated with microwire use; one (1.4%) patient had a T7-related vasospasm resolved with verapamil during thrombectomy without a leading microwire. Differences in complication rates were not statistically significant (p = 0.46). CONCLUSION: In our real-world clinical experience, leading microwire use was infrequently necessary with the T7 delivery catheter. Successful AC delivery and complication rates were similar with and without microwire use in single-pass T7 thrombectomies. Initial pass with T7 may be performed without use of leading microwire, reserving microwire use for refractory cases or known difficult-to-navigate vasculature.

3.
Interv Neuroradiol ; : 15910199231177754, 2023 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-37246314

RESUMEN

PURPOSE: Previous comparative mechanical thrombectomy device trials reported a substantial crossover rate from first-line aspiration to stent-retriever thrombectomy. A specialized delivery catheter may help track large-bore aspiration catheters to target occlusions. We report our multicenter experience of aspiration thrombectomy of intracranial large vessel occlusions using the FreeClimbTM 70 and Tenzing® 7 delivery catheter (Route 92, San Mateo, CA). METHODS: After local Institutional Review Board approval, we retrospectively reviewed the clinical, procedural, and imaging data of patients who underwent mechanical thrombectomy with the FreeClimb 70 and Tenzing 7. RESULTS: FreeClimb 70 was successfully delivered using Tenzing 7 to target occlusion in 30/30 (100%) patients (18 M1, 6 M2, 4 ICA-terminus, and 2 basilar artery occlusions), without the use of a stent-retriever for anchoring. In 21/30 (70%) cases, a leading microwire was not needed to advance the Tenzing 7 to the target. Median (interquartile range) time from groin puncture to first pass was 12 (interquartile range 8-15) minutes. Overall first pass effect, or first pass effect (modified thrombolysis in cerebral ischemia 2C-3), was achieved 16/30 (53%). For M1 occlusions, first pass effect was 11/18 (61%). Successful reperfusion (modified thrombolysis in cerebral ischemia ≥ 2B) was achieved in 29/30 (97%) cases after a median of 1 pass (interquartile range 1-3). Median groin puncture to reperfusion time was 16 (interquartile range 12-26) minutes. There were no procedural complications or symptomatic intracranial hemorrhage. Average improvement in National Institutes of Health Stroke Scale at discharge was 6.6 ± 7.1. There were three patient deaths (renal failure, respiratory failure, and comfort care). CONCLUSIONS: Initial data support the use of Tenzing 7 with FreeClimb 70 catheter for reliable access to rapid, effective, and safe aspiration thrombectomy of large vessel occlusions.

4.
Neurointervention ; 18(1): 47-57, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36328761

RESUMEN

Aspiration catheters are widely used for thrombectomy either alone or in combination with a stent-retriever, with a distal inner diameter and trackability keys to their success. In an illustrative case series, we report our clinical experience with AXS Vecta (Stryker Neurovascular, Fremont, CA, USA), available in both 0.071-inch and 0.074-inch distal inner diameters, including the first 2 Vecta 74 cases reported. A literature review on AXS Vecta is also provided. In our series, 9 thrombectomies were performed (Vecta 71: 2 M1, 5 M2 occlusions; Vecta 74: 1 M1 and 1 ICA-terminus occlusion). The AXS Vecta was successfully delivered to the target site in all cases. In 7 of 9 cases, the catheter was delivered over a Tenzing 7 delivery catheter (Route 92 Medical, San Mateo, CA, USA). For 2 of 9 combination approach cases, Vecta was delivered using the stent-retriever wire as a rail. The median improvement in NIHSS score during hospitalization was 9 (IQR 5-12). Successful mTICI 2C or 3 recanalization was achieved in 8 of 9 (89%) patients after a median 2 (IQR 1-2) passes. Our median groin-to-reperfusion time was 23 (IQR 12.5-32) minutes, with no procedural complications. Two previous clinical studies of a total of 29 patients treated with Vecta 71 reported successful mTICI 2b-3 recanalization in 89-90% of cases. The Median groin-to-reperfusion time was 30 minutes. Complications were seen in 2 of 29 (6.9%) cases (vessel perforation and/or intracerebral hemorrhage). These data support the efficacy, deliverability, and safety of AXS Vecta for mechanical thrombectomy.

5.
J Hand Surg Eur Vol ; 47(4): 387-392, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34851782

RESUMEN

We investigated the reliability of the 4Fusion® quadripodal memory staple in a consecutive series of 59 four-corner arthrodeses in a single centre. Forty-one patients (46 wrists) had a radiological and clinical assessment at a mean follow-up of 7.4 years. Thirteen patients (13 wrists) were lost to follow-up. Bone union was achieved in all but one patient. Seven patients were reoperated, six for device removal and one for nonunion. Most patients were satisfied, had a functional range of wrist mobility, good strength and were free of pain, comparable with the best previously reported series.Level of evidence: IV.


Asunto(s)
Hueso Escafoides , Artrodesis , Fuerza de la Mano , Humanos , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Estudios Retrospectivos , Hueso Escafoides/cirugía , Articulación de la Muñeca/cirugía
7.
J Neurointerv Surg ; 13(4): 378-383, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33443128

RESUMEN

BACKGROUND: Intraoperative neuromonitoring (IONM) is often used during cerebral endovascular procedures. OBJECTIVE: To investigate the relationship between intraoperative vascular complications and IONM signal changes, and the impact of interventions on signal resolution and postoperative outcomes. METHODS: A series of 2278 cerebral endovascular procedures conducted under general anesthesia and using electroencephalography and somatosensory evoked potential monitoring were retrospectively reviewed. A subset of 763 procedures also included motor evoked potentials (MEPs). IONM alerts were categorized as either a partial attenuation or complete loss of signal. Vascular complications were subcategorized as due to rupture, emboli, instrumentation, or vasospasm. Odds ratios (ORs) for new postoperative motor deficits were calculated and diagnostic accuracy was measured using sensitivity, specificity, and likelihood ratios. RESULTS: The overall incidence of new postoperative motor deficit was 1.2%; 20.4% in cases with an IONM alert and 0.09% in cases without an alert. Relative to procedures with no alerts, odds of a new deficit increased if there was partial signal attenuation (OR=210.9, 95% CI 44.3 to 1003.5, p<0.0001) and increased further with complete loss of signal (OR=1437.3, 95% CI 297.3 to 6948.2, p<0.0001). Relative to procedures with unresolved alerts, odds of a new deficit decreased if the alert was fully resolved (OR=0.039, 95% CI 0.005 to 0.306, p<0.002). Procedures using MEPs had slightly higher sensitivity (92.3% vs 85.7%) but slightly lower specificity (96.7% vs 98.2%). CONCLUSIONS: An IONM alert associated with an arterial complication is associated with a dramatic increase in odds of a new postoperative deficit; however, if there is resolution of the alert prior to closure, odds of a new deficit decrease significantly.


Asunto(s)
Procedimientos Endovasculares/efectos adversos , Potenciales Evocados Motores/fisiología , Potenciales Evocados Somatosensoriales/fisiología , Complicaciones Intraoperatorias/diagnóstico por imagen , Complicaciones Intraoperatorias/etiología , Monitorización Neurofisiológica Intraoperatoria/métodos , Adulto , Anestesia General/efectos adversos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Complicaciones Intraoperatorias/fisiopatología , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/métodos , Estudios Retrospectivos , Resultado del Tratamiento
8.
J Neurointerv Surg ; 13(8): 722-726, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32883781

RESUMEN

BACKGROUND: In large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience. METHODS: In a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7. RESULTS: In vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%). CONCLUSION: Compared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model's observations.


Asunto(s)
Arterias Carótidas/cirugía , Catéteres , Revascularización Cerebral , Diseño de Equipo , Embolia Intracraneal , Accidente Cerebrovascular Isquémico , Arteria Cerebral Media/cirugía , Trombectomía , Revascularización Cerebral/instrumentación , Revascularización Cerebral/métodos , Humanos , Embolia Intracraneal/complicaciones , Embolia Intracraneal/cirugía , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/cirugía , Ensayo de Materiales/métodos , Estudios Retrospectivos , Trombectomía/instrumentación , Trombectomía/métodos , Resultado del Tratamiento
9.
Interv Neuroradiol ; 20(3): 261-74, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24976087

RESUMEN

Arterial fenestrations are an anatomic variant with indeterminate significance. Given the controversy surrounding fenestrations we sought their prevalence within our practice along with their association with other cerebrovascular anomalies. We retrospectively reviewed 10,927 patients undergoing digital subtraction angiography between 1992 and 2011. Dictated reports were searched for the terms "fenestration" or "fenestrated" with images reviewed for relevance, yielding 228 unique cases. A Medline database search from February 1964 to January 2013 generated 304 citations, 127 cases of which were selected for analysis. Cerebral arterial fenestrations were identified in 228 patients (2.1%). At least one aneurysm was noted in 60.5% of patients, with an aneurysm arising from the fenestration in 19.6% of patients. Aneurysmal subarachnoid hemorrhage or non-aneurysmal subarachnoid hemorrhage were present in 60.1% and 15.8%, respectively. For the subset of patients with an aneurysm arising directly from a fenestration relative to those patients with an aneurysm not immediately associated with a fenestration, the prevalence of aneurysmal subarachnoid hemorrhage was 66.7% vs. 58.6% (p = 0.58). Fenestrations were more often within the posterior circulation (73.2%) than the anterior circulation (24.6%), though there was no difference in the prevalence of aneurysms within these groups (61.1% vs. 60.7%, p = 1.0). Cerebral arterial fenestrations are an anatomic variant more often manifesting at the anterior communicating arterial complex and basilar artery and with no definite pathological relationship with aneurysms.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central/epidemiología , Arterias Cerebrales/anomalías , Aneurisma Intracraneal/epidemiología , Hemorragia Subaracnoidea/epidemiología , Adulto , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Angiografía Cerebral/estadística & datos numéricos , Arterias Cerebrales/diagnóstico por imagen , Comorbilidad , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Factores de Riesgo , Hemorragia Subaracnoidea/diagnóstico por imagen
10.
J Neurointerv Surg ; 6(10): 785-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24385553

RESUMEN

BACKGROUND AND PURPOSE: Retinoblastoma (RB) is a rare malignancy affecting the pediatric population. Intravenous chemotherapy is the longstanding delivery method, although intra-arterial (IA) chemotherapy is gaining popularity given the reduced side effects compared with systemic chemotherapy administration. Given the sensitivity of the target organ, patient age, and secondary tumor susceptibility, a premium has been placed on minimizing procedural related radiation exposure. MATERIALS AND METHODS: To reduce patient x-ray dose during the IA infusion procedure, customized surgical methods and fluoroscopic techniques were employed. The routine fluoroscopic settings were changed from the standard 7.5 pulses/s and dose level to the detector of 36 nGy/pulse, to a pulse rate of 4 pulses/s and detector dose to 23 nGy/pulse. The angiographic dose indicators (reference point air kerma (Ka) and fluoroscopy time) for a cohort of 10 consecutive patients (12 eyes, 30 infusions) were analyzed. An additional four cases (five eyes, five infusions) were analyzed using dosimeters placed at anatomic locations to reflect scalp, eye, and thyroid dose. RESULTS: The mean Ka per treated eye was 20.1±11.9 mGy with a mean fluoroscopic time of 8.5±4.6 min. Dosimetric measurements demonstrated minimal dose to the lens (0.18±0.10 mGy). Measured entrance skin doses varied from 0.7 to 7.0 mGy and were 73.4±19.7% less than the indicated Ka value. CONCLUSIONS: Ophthalmic arterial melphalan infusion is a safe and effective means to treat RB. Modification to contemporary fluoroscopic systems combined with parsimonious fluoroscopy can minimize radiation exposure.


Asunto(s)
Neoplasias de la Retina/terapia , Retinoblastoma/terapia , Antineoplásicos Alquilantes/administración & dosificación , Antineoplásicos Alquilantes/uso terapéutico , Terapia Combinada , Femenino , Fluoroscopía , Humanos , Lactante , Infusiones Intraarteriales , Masculino , Melfalán/administración & dosificación , Melfalán/uso terapéutico , Dosis de Radiación , Neoplasias de la Retina/tratamiento farmacológico , Neoplasias de la Retina/radioterapia , Retinoblastoma/tratamiento farmacológico , Retinoblastoma/radioterapia
12.
J Neurointerv Surg ; 5(5): 478-82, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22693248

RESUMEN

Segmental arterial mediolysis (SAM) is a rare, non-inflammatory, non-atherosclerotic vasculopathy typically affecting the abdominal arteries although it may also affect the great vessels and cerebral vasculature. Diseased vessels manifest with aneurysms and/or dissections, often presenting clinically with catastrophic thromboembolic injury and less frequently with subarachnoid hemorrhage (SAH). The etiology of SAM remains indeterminate although there is evidence it may be an endogenous pathological response to vasospasm. The SAM literature is reviewed and a case of SAH related to a ruptured dissecting-type vertebral artery aneurysm is described. In addition to furthering awareness of SAM, this unique case offers insight into the acute phase of the disease and the potential role of vasospastic induction.


Asunto(s)
Fístula Arteriovenosa/diagnóstico por imagen , Angiografía Cerebral/métodos , Arterias Mamarias/diagnóstico por imagen , Hemorragia Subaracnoidea/diagnóstico por imagen , Disección de la Arteria Vertebral/diagnóstico por imagen , Angiografía de Substracción Digital , Aorta Abdominal/diagnóstico por imagen , Humanos , Hipertensión/inducido químicamente , Masculino , Persona de Mediana Edad , Paresia/etiología , Tomografía Computarizada por Rayos X , Estimulación Magnética Transcraneal , Ultrasonografía Doppler Transcraneal , Vasoespasmo Intracraneal/etiología
13.
Stroke ; 44(1): 243-5, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23111438

RESUMEN

BACKGROUND AND PURPOSE: Can lysability of large vessel thrombi in acute ischemic stroke be predicted by measuring clot density on admission nonenhanced CT (NECT), postcontrast enhanced CT, or CT angiogram (CTA)? METHODS: We retrospectively studied 90 patients with acute large vessel ischemic strokes treated with intravenous (IV) tPA, intra-arterial (IA) tPA, and/or mechanical thrombectomy devices. Clot density [in Hounsfield unit (HU)] was measured on NECT, postcontrast enhanced CT, and CTA. Recanalization was assessed by the Thrombolysis in Cerebral Infarction grading system (TICI) on digital subtraction angiography. RESULTS: Thrombus density on preintervention NECT correlated with postintervention TICI grade regardless of pharmacological (IV tPA r=0.69, IA tPA r=0.72, P<0.0001) or mechanical treatment (r=0.73, P<0.0001). Patients with TICI≥2 demonstrated higher HU on NECT (mean corrected HU IV tPA=1.58, IA tPA=1.66, mechanical treatment=1.7) compared with patients with TICI<2 (IV tPA=1.39, IA tPA=1.4, mechanical treatment=1.3) (P=0.01, 0.006, <0.0001 respectively). There was no association between recanalization and age, sex, baseline National Institute of Health Stroke Scale, treatment method, time to treatment, or clot volume. CONCLUSIONS: Thrombi with lower HU on NECT appear to be more resistant to pharmacological lysis and mechanical thrombectomy. Measuring thrombus density on admission NECT provides a rapid method to analyze clot composition, a potentially useful discriminator in selecting the most appropriate reperfusion strategy for an individual patient.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Revascularización Cerebral/tendencias , Trombosis Intracraneal/diagnóstico por imagen , Admisión del Paciente/tendencias , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/tendencias , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/cirugía , Revascularización Cerebral/métodos , Femenino , Humanos , Trombosis Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Accidente Cerebrovascular/cirugía , Resultado del Tratamiento
14.
J Neurointerv Surg ; 4(4): e16, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21990490

RESUMEN

Retinoblastoma is a rare and curable malignancy affecting the pediatric population. For advanced stage intraocular retinoblastoma, enucleation remains the primary treatment modality, although the use of laser photocoagulation, cryotherapy, radiotherapy and chemotherapy are frequently used, particularly in the setting of bilateral disease. Intravenous chemotherapy is the long-standing method of delivery, but local administration (subtenon, intravitreal or intra-arterial) is gaining in popularity because of the reduced side effects related to systemic administration. Of these newer methods, intra-arterial infusion has demonstrated technical feasibility, few procedural complications and robust tumor response. A case is described where a collateral supply to the affected ophthalmic artery was via the zygomatico-orbital branch of the ipsilateral superficial temporal artery. Melphalan infusion was performed via this pathway without incident.


Asunto(s)
Melfalán/administración & dosificación , Neoplasias de la Retina/tratamiento farmacológico , Retinoblastoma/tratamiento farmacológico , Arterias Temporales/efectos de los fármacos , Preescolar , Humanos , Infusiones Intraarteriales , Masculino , Órbita/irrigación sanguínea , Órbita/diagnóstico por imagen , Radiografía , Neoplasias de la Retina/diagnóstico por imagen , Retinoblastoma/diagnóstico por imagen , Arterias Temporales/diagnóstico por imagen , Cigoma/irrigación sanguínea , Cigoma/diagnóstico por imagen
15.
Proc Natl Acad Sci U S A ; 99(26): 17143-8, 2002 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-12481038

RESUMEN

Synaptojanin 1 is a polyphosphoinositide phosphatase implicated in synaptic vesicle recycling. We used FM1-43 imaging and electron microscopy in cultured cortical neurons from control and synaptojanin 1 knockout mice to study how the absence of this protein affects specific steps of the synaptic vesicle cycle. Exoendocytosis after a moderate stimulus was unchanged. However, during prolonged stimulation, the regeneration of fusion-competent synaptic vesicles was severely impaired. In stimulated nerve terminals, there was a persistent accumulation of clathrin-coated vesicles and a backup of newly reformed vesicles in the cytomatrix-rich area around the synaptic vesicle cluster. These findings demonstrate that synaptojanin 1 function is needed for the progression of recycling vesicles to the functional synaptic vesicle pool.


Asunto(s)
Proteínas del Tejido Nervioso/fisiología , Monoéster Fosfórico Hidrolasas/fisiología , Vesículas Sinápticas/fisiología , Animales , Fusión Celular , Células Cultivadas , Corteza Cerebral/fisiología , Vesículas Cubiertas por Clatrina/fisiología , Endocitosis , Exocitosis , Ratones , Ratones Noqueados , Microscopía Electrónica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA