Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Histochem Cell Biol ; 155(1): 19-73, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33040183

RESUMEN

This multidisciplinary study examined the pharmacokinetics of nanoparticles based on albumin-DTPA-gadolinium chelates, testing the hypothesis that these nanoparticles create a stronger vessel signal than conventional gadolinium-based contrast agents and exploring if they are safe for clinical use. Nanoparticles based on human serum albumin, bearing gadolinium and designed for use in magnetic resonance imaging, were used to generate magnet resonance images (MRI) of the vascular system in rats ("blood pool imaging"). At the low nanoparticle doses used for radionuclide imaging, nanoparticle-associated metals were cleared from the blood into the liver during the first 4 h after nanoparticle application. At the higher doses required for MRI, the liver became saturated and kidney and spleen acted as additional sinks for the metals, and accounted for most processing of the nanoparticles. The multiple components of the nanoparticles were cleared independently of one another. Albumin was detected in liver, spleen, and kidneys for up to 2 days after intravenous injection. Gadolinium was retained in the liver, kidneys, and spleen in significant concentrations for much longer. Gadolinium was present as significant fractions of initial dose for longer than 2 weeks after application, and gadolinium clearance was only complete after 6 weeks. Our analysis could not account quantitatively for the full dose of gadolinium that was applied, but numerous organs were found to contain gadolinium in the collagen of their connective tissues. Multiple lines of evidence indicated intracellular processing opening the DTPA chelates and leading to gadolinium long-term storage, in particular inside lysosomes. Turnover of the stored gadolinium was found to occur in soluble form in the kidneys, the liver, and the colon for up to 3 weeks after application. Gadolinium overload poses a significant hazard due to the high toxicity of free gadolinium ions. We discuss the relevance of our findings to gadolinium-deposition diseases.


Asunto(s)
Albúminas/farmacocinética , Quelantes/farmacocinética , Medios de Contraste/farmacocinética , Gadolinio DTPA/farmacocinética , Imagen por Resonancia Magnética , Nanopartículas/química , Albúminas/administración & dosificación , Animales , Quelantes/administración & dosificación , Medios de Contraste/administración & dosificación , Femenino , Gadolinio DTPA/administración & dosificación , Inyecciones Intravenosas , Masculino , Ratones , Ratones Endogámicos BALB C , Nanopartículas/administración & dosificación , Ratas , Ratas Sprague-Dawley , Distribución Tisular
4.
Histochem Cell Biol ; 134(2): 171-96, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20628754

RESUMEN

We are developing a nanoparticulate histochemical reagent designed for histochemistry in living animals (molecular imaging), which should finally be useful in clinical imaging applications. The iterative development procedure employed involves conceptual design of the reagent, synthesis and testing of the reagent, then redesign based on data from the testing; each cycle of testing and development generates a new generation of nanoparticles, and this report describes the synthesis and testing of the third generation. The nanoparticles are based on human serum albumin and the imaging modality selected is magnetic resonance imaging (MRI). Testing the second particle generation with newly introduced techniques revealed the presence of impurities in the final product, therefore we replaced dialysis with diafiltration. We introduced further testing methods including thin layer chromatography, arsenazo III as chromogenic assay for gadolinium, and several versions of polyacrylamide gel electrophoresis, for physicochemical characterisation of the nanoparticles and intermediate synthesis compounds. The high grade of chemical purity achieved by combined application of these methodologies allowed standardised particle sizes to be achieved (low dispersities), and accurate measurement of critical physicochemical parameters influencing particle size and imaging properties. Regression plots confirmed the high purity and standardisation. The good degree of quantitative physicochemical characterisation aided our understanding of the nanoparticles and allowed a conceptual model of them to be prepared. Toxicological screening demonstrated the extremely low toxicity of the particles. The high magnetic resonance relaxivities and enhanced mechanical stability of the particles make them an excellent platform for the further development of MRI molecular imaging.


Asunto(s)
Medios de Contraste/química , Imagen por Resonancia Magnética/métodos , Nanopartículas/uso terapéutico , Albúmina Sérica/uso terapéutico , Diseño de Fármacos , Estabilidad de Medicamentos , Humanos , Ensayo de Materiales , Nanopartículas/química , Albúmina Sérica/química
5.
Histochem Cell Biol ; 133(4): 375-404, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20174817

RESUMEN

To develop a platform for molecular magnetic resonance imaging, we prepared gadolinium-bearing albumin-polylactic acid nanoparticles in the size range 20-40 nm diameter. Iterative cycles of design and testing upscaled the synthesis procedures to gram amounts for physicochemical characterisation and for pharmacokinetic testing. Morphological analyses showed that the nanoparticles were spheroidal with rough surfaces. Particle sizes were measured by direct transmission electron microscopical measurements from negatively contrasted preparations, and by use of photon correlation spectroscopy; the two methods each documented nanoparticle sizes less than 100 nm and generally 10-40 nm diameter, though with significant intrabatch and interbatch variability. The particles' charge sufficed to hold them in suspension. HSA retained its tertiary structure in the particles. The nanoparticles were stable against turbulent flow conditions and against heat, though not against detergents. MRI imaging of liquid columns was possible at nanoparticle concentrations below 10 mg/ml. The particles were non-cytotoxic, non-thrombogenic and non-immunogenic in a range of assay systems developed for toxicity testing of nanoparticles. They were micellar prior to lyophilisation, but loosely structured aggregated masses after lyophilisation and subsequent resuspension. These nanoparticles provide a platform for further development, based on non-toxic materials of low immunogenicity already in clinical use, not expensive, and synthesized using methods which can be upscaled for industrial production.


Asunto(s)
Medios de Contraste/química , Gadolinio/química , Espectroscopía de Resonancia Magnética , Nanopartículas/química , Nanopartículas/ultraestructura , Albúminas/química , Albúminas/ultraestructura , Imagen por Resonancia Magnética/métodos , Microscopía Electrónica de Transmisión , Tamaño de la Partícula
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA