Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Coron Artery Dis ; 35(1): 44-49, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37990534

RESUMEN

INTRODUCTION: Elevated peak cardiac troponin levels have been linked with increased morbidity and mortality in patients with acute myocardial infarction (AMI). Immature Platelets are young and relatively large platelets that are hyper-reactive and pro-thrombotic compared to regular platelets. Increased immature platelet fraction (IPF) has been associated with an elevated risk of thrombotic events. We hypothesize that patients with higher IPF levels during AMI, will experience a more severe infarct, leading to elevated peak troponin levels. METHODS: Clinical data from patients admitted to the cardiology division between 2018 and 2022, who were diagnosed with AMI and underwent an IPF testing. Univariate and multivariate regression analyses were performed to identify predictors of elevated peak troponin. RESULTS: Among the 277 patients diagnosed with AMI who underwent IPF testing, 113 had (STEMI) and 164 had (NSTEMI). The median value of IPF of 4.2% was used as the threshold for defining elevated IPF. Notably, among STEMI patients, those with IPF ≥ 4.2% had significantly higher peak troponin levels ( P  = 0.021). Conversely, no significant difference in peak troponin levels was observed among NSTEMI patients ( P  = 0.348). Multivariate analysis identified patients with STEMI in the higher IPF group as one of the significant predictors for elevated peak troponin levels. CONCLUSION: This study revealed a correlation between higher baseline IPF levels and increased peak troponin levels specifically in STEMI patients, while no such association was found in NSTEMI patients. Incorporating IPF levels above the median into risk stratification scores for STEMI patients may provide valuable support for adopting a more proactive therapeutic approach.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Infarto del Miocardio con Elevación del ST , Humanos , Troponina , Infarto del Miocardio sin Elevación del ST/diagnóstico , Biomarcadores
2.
Am Heart J ; 261: 127-136, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37225386

RESUMEN

BACKGROUND: A robotic Radiaction Shielding System (RSS) was developed to provide a full-body protection to all medical personnel during fluoroscopy-guided procedures, by encapsulating the imaging beam and blocking scattered radiation. OBJECTIVES: We aimed to evaluate its efficacy in real-world electrophysiologic (EP) laboratory- both during ablations and cardiovascular implantable electronic devices (CIED) procedures. METHODS: A prospective controlled study comparing consecutive real-life EP procedures with and without RSS using highly sensitive sensors in different locations. RESULTS: Thirty-five ablations and 19 CIED procedures were done without RSS installed and 31 ablations and 24 CIED procedures (17 with usage levels ≥70%) were done with RSS. Overall, there was 95% average usage level for ablations and 88% for CIEDs. For all procedures with ≥70% usage level and for all sensors, the radiation with RSS was significantly lower than radiation without RSS. For ablations, there was 87% reduction in radiation with RSS (76%-97% for different sensors). For CIEDs, there was 83% reduction in radiation with RSS (59%-92%). RSS usage did not increase procedure time and radiation time. User feedback showed a high-level of integration in the clinical workflow and safety profile for all types of EP procedures. CONCLUSIONS: For both CIED and ablation procedures the radiation with RSS was significantly lower than without RSS. Higher usage level brings higher reduction rates. Thus, RSS may have an important role in full-body protection to all medical personnel from scattered radiation during EP and CIED procedures. Until more data is available, it is recommended to maintain existing standard shielding.


Asunto(s)
Técnicas de Ablación , Procedimientos Quirúrgicos Robotizados , Humanos , Estudios Prospectivos , Electrónica
3.
Coron Artery Dis ; 34(2): 96-101, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36515228

RESUMEN

INTRODUCTION: Patients who present to the emergency department with chest pain during an episode of atrial fibrillation (AF) impose a clinical challenge regarding the source of pain - being coronary artery disease (CAD) or AF in origin. The aim of this study was to identify clinical, imaging or laboratory markers which can predict significant CAD among patients with an AF episode and chest pain. METHODS: We included 57 consecutive patients admitted to our hospital with AF and chest pain. All patients underwent coronary evaluation. Significant CAD was defined as >50% stenosis in a major coronary artery by coronary angiography or cardiac CT. We compared CAD and non-CAD groups and analyzed risk factorsby regression analysis. RESULTS: Twenty-four patients (42%) were diagnosed with- and 33 patients (58%) without obstructive CAD. In a multivariate analysis of regional wall motion abnormality (RWMA), elevated troponin and hypertension were found to be predictors for CAD [odds ratio (OR), 22.4 (confidence interval (CI), 1.8-272.4; P = 0.02); OR, 5.6 (CI, 1-31.0; P = 0.05) and OR, 21.4 (CI, 1.6-284.6; P = 0.02), respectively]. There were no significant differences regarding the rate of typical chest pain at presentation in the CAD vs. the non-CAD group [13 (54%) vs. 20 (60%), P = 0.374], or in ECG ST-changes [12 (50%) vs.9 (27%), respectively; P = 0.08]. CONCLUSION: In patients who present acutely with chest pain and AF, troponin elevation and RWMA appear to be highly predictive of obstructive CAD, whereas clinical symptoms and ECG changes are not predictive. These findings may be helpful for guiding the management of patients admitted with AF and chest pain.


Asunto(s)
Fibrilación Atrial , Enfermedad de la Arteria Coronaria , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/epidemiología , Dolor en el Pecho/etiología , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Troponina , Hospitalización
5.
Isr Med Assoc J ; 24(1): 25-32, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35077042

RESUMEN

BACKGROUND: Endocardial leads of permanent pacemakers (PPM) and implantable defibrillators (ICD) across the tricuspid valve (TV) can lead to tricuspid regurgitation (TR) or can worsen existing TR with subsequent severe morbidity and mortality. OBJECTIVES: To evaluate prospectively the efficacy of intraprocedural 2-dimentional-transthoracic echocardiography (2DTTE) in reducing/preventing lead-associated TR. METHODS: We conducted a prospective randomized controlled study comparing echocardiographic results in patients undergoing de-novo PPM/ICD implantation with intraprocedural echo-guided right ventricular (RV) lead placement (Group 1, n=56) versus non-echo guided implantation (Group 2, n=55). Lead position was changed if TR grade was more than baseline in Group 1. Cohort patients underwent 2DTTE at baseline and 3 and/or 6 months after implantation. Excluded were patients with baseline TR > moderate or baseline ≥ moderate RV dysfunction. RESULTS: The study comprised 111 patients (74.14 ± 11 years of age, 58.6% male, 19% ICD, 42% active leads). In 98 patients there was at least one follow-up echo. Two patients from Group 1 (3.6%) needed intraprocedural RV electrode repositioning. Four patients (3.5%, 2 from each group, all dual chamber PPM, 3 atrial fibrillation, 2 RV pacing > 40%, none with intraprocedural reposition) had TR deterioration during 6 months follow-up. One patient from Group 2 with baseline mild-moderate aortic regurgitation (AR) had worsening TR and AR within 3 months and underwent aortic valve replacement and TV repair. CONCLUSIONS: The rate of mechanically induced lead-associated TR is low; thus, a routine intraprocedural 2DTTE does not have a significant role in reducing/preventing it.


Asunto(s)
Ecocardiografía/métodos , Complicaciones Posoperatorias , Ajuste de Prótesis , Implantación de Prótesis , Cirugía Asistida por Computador/métodos , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide/diagnóstico por imagen , Anciano , Estimulación Cardíaca Artificial/métodos , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Femenino , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Marcapaso Artificial , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Ajuste de Prótesis/efectos adversos , Ajuste de Prótesis/métodos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/prevención & control
6.
J Atr Fibrillation ; 13(5): 2459, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34950336

RESUMEN

BACKGROUND: Recent trials found poor temporal relationship between atrial fibrillation (AF) episodes and strokes. Thus, stroke in AF patients probably involves more mechanisms than cardiac embolism. We compared factors of inflammation, thrombosis and platelet reactivity between left (LA) and right atria (RA) and femoral vein (FV) in patients with AF. METHODS: Blood samples were collected from patients undergoing AF-ablation from the FV, RA and LA for neutrophil to lymphocyte ratio (NLR), immature platelet fraction (IPF) and count (IPC), CD40 ligand, P-selectin and E-Selectin. IPF was measured by an autoanalyzer; CD40 ligand, P-selectin, and E-Selectin were measured by ELISA and NLR was calculated from complete blood counts. RESULTS: Sixty-seven patients were included (age 65±10y, 63% male, CHA2DS2-VASc score 2.8±1.8, LA volume index 40±24 mL/m2, 63% paroxysmal AF). There was no difference between FV, RA and LA regarding NLR and CD40 ligand. Factors associated with platelets activity: P-selectin, IPC and IPF% were higher in RA vs LA (60.3 IQR 49.0-76.4 ng/ml vs. 59.3 IQR 49.0-74.7, respectively, p=0.03 for P-selectin, 7.5 IQR 5.2-10 103/µL vs. 7.1 IQR 5-9.8, p<0.01 for IPC, and 3.6 IQR 2.7-5.0 % vs. 3.6 IQR 2.6-4.8, p<0.01 for IPF%). Similar trends were for E-selectin (41.2 IQR 31.1-51.2 ng/mL vs. 38.7 IQR 27.9-50.4 p=0.09). Similar significant differences were found in patients with CHA2DS2-VASC≥2 but not in patients with low score. CONCLUSIONS: Patients with AF, especially those with CHA2DS2-VASc≥2, have higher markers of thrombogenicity in RA compared to LA. There was no difference in inflammatory properties between the atria.

7.
J Cardiovasc Electrophysiol ; 32(2): 305-315, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33331056

RESUMEN

BACKGROUND: Strain imaging during left atrial (LA) reservoir phase (LASr) is used as a surrogate for LA structural remodeling and fibrosis. Atrial fibrillation (AF) patients with >5% low-voltage zones (LVZs) obtained by 3D-electro-anatomical-mapping have higher recurrence rate post-ablation. We investigated the relationship between LA remodeling using two-dimensional-speckle-tracking echocardiography (2D-STE) and high-density voltage mapping in AF patients. METHODS: A prospective study of 42 consecutive patients undergoing AF ablation. 2D-echo, 2D-STE, and high-density contact LA bipolar voltage maps were constructed before ablation. LVZs were determined with different bipolar amplitudes and their ratio per patient's LA area were investigated for correlation with LASr. We compared 2D-LASr results in patients with LVZs ≥ 5% (LVZs group) versus those with LVZ < 5% (non-LVZs group). RESULTS: Compared with non-LVZs group (n = 15), LVZs group (n = 27) included significantly older patients, more women, more persistent AF, higher CHA2 DS2 -VASc score, higher E/A ratio and higher LA volume index (p < .05). LVZs group had lower %LASr values (12.4 ± 5.9% vs. 21.1 ± 6.3, respectively; p<.001). LVZs% in different amplitudes (<0.1 mV, <0.2 mV, and <0.5 mV) were negatively correlated with %LASr (r = -.63, r = -.68, and r = -.72, respectively; p< .001). Atrial strain thresholds for LVZs ≥ 5% in amplitudes <0.1 mV, <0.2 mV, and <0.5 mV were associated with %LASr 12.98, 16.16 and 19.55, respectively; p< .05). In a multivariate analysis, %LASr was the only independent indicator of LVZs (OR, 0.8; 95% CI, 0.6-0.9; p= .04). CONCLUSIONS: LVZs ≥ 5% has a negative association with atrial %LASr. Thus, a simple 2D-STE measurement of %LASr can be used as a noninvasive method to evaluate significant LA remodeling and fibrosis in AF patients.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ecocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Estudios Prospectivos
8.
Int J Lab Hematol ; 43(4): 602-608, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33289968

RESUMEN

PURPOSE: Atrial fibrillation (AF) is associated with platelet hyperactivity and a higher proportion of immature platelets. We aimed to examine whether immature platelet fraction (IPF) and inflammatory markers differ between AF types and whether they are affected by ablation. METHODS: A prospective study included patients with atrial fibrillation/flutter (AFL). We excluded patients with hematologic, inflammatory, or acute coronary states. Blood samples for IPF, white blood cells (WBC), neutrophil-to-lymphocyte ratio (NLR), and C-reactive protein (CRP) were collected at baseline, within one-hour postablation in those undergoing ablations, and the day after ablation. IPF was measured by an autoanalyzer (Sysmex 2100 XE). RESULTS: One hundred and four patients were included (paroxysmal AF-63, persistent AF-36, AF and AFL-7, AFL alone-5), (Mean age 67.7 ± 12.8 years, 54.8% male, CHA2 D2 -VASC2 3.2 ± 1.8). Seventy-two patients underwent ablation (cryoballoon AF ablation-60, AFL radiofrequency ablation-5, both-7). There was no difference between paroxysmal and persistent AF regarding baseline markers. There was a significant change in the following parameters after ablation: WBC (baseline 6.9 ± 2.0, 1-h post 8.0 ± 2.4, and 1-day post 9.0 ± 2.8 ×109 /L), NLR (2.9 ± 2.2, 3.0 ± 2.4, 4.2 ± 2.9, respectively), and CRP (3.6 ± 3.7, 3.6 ± 3.5, 12.4 ± 9.0 mg/L, respectively) (P < .05 for all). However, there were no differences in immature platelet count (8.6 ± 4.8, 8.5 ± 4.9, 8.4 ± 5.2 ×109 /L) or IPF (4.6 ± 3.2, 4.7 ± 3.3, 4.9 ± 3.6%) from baseline to postablation (p = NS). CONCLUSIONS: AF persistency does not affect IPF and inflammation. In patients undergoing cryoablation of AF, there is a postablation inflammatory process; however, platelet activation is probably not affected.


Asunto(s)
Fibrilación Atrial , Plaquetas/metabolismo , Proteína C-Reactiva/metabolismo , Ablación por Catéter , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/sangre , Fibrilación Atrial/cirugía , Biomarcadores/sangre , Femenino , Humanos , Inflamación/sangre , Inflamación/cirugía , Masculino , Persona de Mediana Edad , Recuento de Plaquetas , Estudios Prospectivos
9.
Eur Heart J Case Rep ; 4(6): 1-9, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33442601

RESUMEN

INTRODUCTION: Cannabis use is known to be associated with significant cardiovascular morbidity. We describe three cases of cannabis-related malignant arrhythmias, who presented to the cardiac department at our institution within the last 2 years. All three patients were known to smoke cannabis on daily basis. CASE SUMMARIES: Case 1: A 30-year-old male, presented with recent onset of palpitations. A 12-lead electrocardiogram (ECG), transthoracic echocardiogram (TTE), and blood tests were all normal. During an inpatient exercise treadmill test (ETT) he developed polymorphic ventricular tachycardia (VT), which converted spontaneously to supraventricular tachycardia (SVT) in the recovery phase of the test. Subsequent risk stratification with cardiac magnetic resonance imaging and coronary angiography showed no abnormalities and an electrophysiological study was negative for sustained VT, however, SVT was easily induced with rapid conversion to atrial fibrillation. The patient successfully stopped smoking all tobacco products including cannabis and was treated with beta-blockers, with no further episodes of arrhythmia. Case 2: A 30-year-old male presented to the Emergency Department with palpitations, chest pain, and dizziness that improved during exertion. His initial ECG demonstrated complete atrioventricular block (AVB). Subsequent traces showed Mobitz Type I and second-degree AVB, which converted to atrial flutter after exertion. Routine blood tests, TTE, and an ETT were all normal and he was discharged home with no conduction abnormalities. Case 3: A 24-year-old male presented with two episodes of syncope. Baseline examination was normal, with an ECG showing a low atrial rhythm. Interrogation of his implantable loop recorder showed episodes of early morning bradycardia episodes with no associated symptoms. DISCUSSION: Cannabis-related arrhythmia can be multiform regarding their presentation. Therefore, ambiguous combinations of arrhythmia should raise suspicion of underlying cannabis abuse, where clinically appropriate. Although causality with regards to cannabis use cannot be proven definitively in these cases, the temporal relationship between drug use and the onset of symptoms suggests a strong association.

12.
J Electrocardiol ; 49(2): 171-3, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26850499

RESUMEN

Adenosine can produce arrhythmias, which are generally short living. It may induce PACs and PVCs, sinus bradycardia, and atrial fibrillation. There have been reports of transient polymorphic VT (torsades de pointes) in patients with LQTS and others in people with normal QT interval. We report a case of a long episode of polymorphic VT induced by adenosine. A 27 year old woman received 6 mg adenosine for PSVT, which terminated and torsades de pointes developed, persisting for 17 seconds and terminated spontaneously. This is the longest described duration of the torsades after adenosine administration in patients with normal QT interval.


Asunto(s)
Adenosina/efectos adversos , Electrocardiografía/efectos de los fármacos , Electrocardiografía/métodos , Torsades de Pointes/inducido químicamente , Torsades de Pointes/diagnóstico , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Vasodilatadores/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA