Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Am Coll Cardiol ; 82(21): 1973-1985, 2023 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-37968015

RESUMEN

BACKGROUND: Exercise echocardiography is used for assessment of pulmonary circulation and right ventricular function, but limits of normal and disease-specific changes remain insufficiently established. OBJECTIVES: The objective of this study was to explore the physiological vs pathologic response of the right ventricle and pulmonary circulation to exercise. METHODS: A total of 2,228 subjects were enrolled: 375 healthy controls, 40 athletes, 516 patients with cardiovascular risk factors, 17 with pulmonary arterial hypertension, 872 with connective tissue diseases without overt pulmonary hypertension, 113 with left-sided heart disease, 30 with lung disease, and 265 with chronic exposure to high altitude. All subjects underwent resting and exercise echocardiography on a semirecumbent cycle ergometer. All-cause mortality was recorded at follow-up. RESULTS: The 5th and 95th percentile of the mean pulmonary artery pressure-cardiac output relationships were 0.2 to 3.5 mm Hg.min/L in healthy subjects without cardiovascular risk factors, and were increased in all patient categories and in high altitude residents. The 5th and 95th percentile of the tricuspid annular plane systolic excursion to systolic pulmonary artery pressure ratio at rest were 0.7 to 2.0 mm/mm Hg at rest and 0.5 to 1.5 mm/mm Hg at peak exercise, and were decreased at rest and exercise in all disease categories and in high-altitude residents. An increased all-cause mortality was predicted by a resting tricuspid annular plane systolic excursion to systolic pulmonary artery pressure <0.7 mm/mm Hg and mean pulmonary artery pressure-cardiac output >5 mm Hg.min/L. CONCLUSIONS: Exercise echocardiography of the pulmonary circulation and the right ventricle discloses prognostically relevant differences between healthy subjects, athletes, high-altitude residents, and patients with various cardio-respiratory conditions. (Right Heart International NETwork During Exercise in Different Clinical Conditions; NCT03041337).


Asunto(s)
Hipertensión Pulmonar , Disfunción Ventricular Derecha , Humanos , Ecocardiografía de Estrés/efectos adversos , Circulación Pulmonar , Prueba de Esfuerzo/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Disfunción Ventricular Derecha/diagnóstico por imagen
2.
J Clin Med ; 12(8)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37109352

RESUMEN

BACKGROUND: Frequent premature ventricular complexes (PVCs) can cause PVC-induced cardiomyopathy. The value of PVC ablation in patients with preserved left ventricular function in the low-normal range (ejection fraction: 50-55%) is not established. Strain analysis has been used to estimate changes in left ventricular function beyond assessment of the ejection fraction (EF). Longitudinal strain has been proposed as a method to detect changes over time in the setting of frequent asymptomatic premature ventricular complexes and preserved left ventricular (LV) function. A decrease in strain may be evidence of PVC-induced cardiomyopathy. OBJECTIVE: In this study, we assessed the role of PVC ablation in patients with low-normal EF and the effect on EF and myocardial strain before and after PVC ablation. METHODS: A total of 70 consecutive patients with either low-normal EF (0.5-<0.55, n = 35) or high-normal EF (≥0.55; n = 35), using available imaging and Holter data, were referred for ablation due to frequent PVCs. EF and longitudinal strain were assessed pre- and post-ablation. RESULTS: There was a significant increase in EF (53.2 ± 0.4% to 58.3 ± 0.5%, p < 0.001) and improvement in longitudinal strain (-15.2 ± 3.3 to -16.6 ± 3, p = 0.007) post-ablation in patients with low-normal EF and successful ablation. There was no change in EF or longitudinal strain in patients with high-normal EF and a successful ablation pre- vs. post-ablation. CONCLUSIONS: Patients with frequent PVCs and low-normal LV EF compared to patients with frequent PVCs and high-normal LV EF have evidence of PVC-induced cardiomyopathy and may benefit from ablation despite a preserved left ventricular EF.

3.
J Clin Med ; 11(14)2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35887884

RESUMEN

Background: Restrictive cardiomyopathy (RCM) places patients at high risk for adverse events. In this study, we aim to evaluate the association between left atrial function and time to adverse events such as all-cause mortality and cardiovascular hospitalizations related to RCM. Material and Methods: In this single-center study, ninety-eight patients with a clinical diagnosis of RCM were recruited from our registry: 30 women (31%); age (mean ± standard deviation) 61 ± 13 years. These patients underwent cardiac magnetic resonance (CMR) imaging from May 2007 to September 2015. Left atrial (LA) function (reservoir, contractile, and conduit strain), LA diameter and area, and left ventricular function (global longitudinal strain, ejection fraction), and volume were quantified, and the presence of late gadolinium enhancement was visually assessed. The cutoff value of the LA reservoir strain was selected based on tertile. An adjusted Cox proportional regression analysis was used to assess time to adverse outcomes with a median follow up of 49 months. Results: In our cohort, all-cause mortality was 36% (35/98). Composite events (all-cause mortality and cardiovascular hospitalizations) occurred in 56% of patients (55/98). All-cause mortality and composite events were significantly associated with a decreased LA reservoir strain (adjusted hazard ratio (aHR) = 0.957, p = 0.002 and aHR = 0.969, p = 0.008) using a stepwise elimination of imaging variables, demographics, and comorbidities. All-cause mortality and composite events were six and almost four times higher, respectively, in patients with the LA reservoir strain <15% (aHR = 5.971, p = 0.005, and HR = 4.252, p = 0.001) compared to patients with the LA reservoir strain >34%. Survival was significantly reduced in patients with an LA reservoir strain <15% (p = 0.008). Conclusions: The decreased LA reservoir strain is independently associated with time to adverse events in patients with RCM.

4.
Int J Cardiovasc Imaging ; 37(7): 2151-2167, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33866467

RESUMEN

Exercise Doppler echocardiography (EDE) is a well-validated tool in ischemic and valvular heart diseases. However, its use in the assessment of the right heart and pulmonary circulation unit (RH-PCU) is limited. The aim of this study is to assess the semi-recumbent bicycle EDE feasibility for the evaluation of RH-PCU in a large multi-center population, from healthy individuals and elite athletes to patients with overt or at risk of developing pulmonary hypertension (PH). From January 2019 to July 2019, 954 subjects [mean age 54.2 ± 16.4 years, range 16-96, 430 women] underwent standardized semi-recumbent bicycle EDE with an incremental workload of 25 watts every 2 min, were prospectively enrolled among 7 centers participating to the RIGHT Heart International NETwork (RIGHT-NET). EDE parameters of right heart structure, function and pressures were obtained according to current recommendations. Right ventricular (RV) function at peak exercise was feasible in 903/940 (96%) by tricuspid annular plane systolic excursion (TAPSE), 667/751 (89%) by tissue Doppler-derived tricuspid lateral annular systolic velocity (S') and 445/672 (66.2%) by right ventricular fractional area change (RVFAC). RV-right atrial pressure gradient [RV-RA gradient = 4 × tricuspid regurgitation velocity2 (TRV)] was feasible in 894/954 patients (93.7%) at rest and in 816/954 (85.5%) at peak exercise. The feasibility rate in estimating pulmonary artery pressure improved to more than 95%, if both TRV and/or right ventricular outflow tract acceleration time (RVOT AcT) were considered. In high specialized echocardiography laboratories semi-recumbent bicycle EDE is a feasible tool for the assessment of the RH-PCU pressure and function.


Asunto(s)
Circulación Pulmonar , Disfunción Ventricular Derecha , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ciclismo , Ecocardiografía Doppler , Estudios de Factibilidad , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Función Ventricular Derecha , Adulto Joven
5.
Cardiovasc Ultrasound ; 19(1): 9, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33472662

RESUMEN

PURPOSE: This study was a quality-control study of resting and exercise Doppler echocardiography (EDE) variables measured by 19 echocardiography laboratories with proven experience participating in the RIGHT Heart International NETwork. METHODS: All participating investigators reported the requested variables from ten randomly selected exercise stress tests. Intraclass correlation coefficients (ICC) were calculated to evaluate the inter-observer agreement with the core laboratory. Inter-observer variability of resting and peak exercise tricuspid regurgitation velocity (TRV), right ventricular outflow tract acceleration time (RVOT Act), tricuspid annular plane systolic excursion (TAPSE), tissue Doppler tricuspid lateral annular systolic velocity (S'), right ventricular fractional area change (RV FAC), left ventricular outflow tract velocity time integral (LVOT VTI), mitral inflow pulsed wave Doppler velocity (E), diastolic mitral annular velocity by TDI (e') and left ventricular ejection fraction (LVEF) were measured. RESULTS: The accuracy of 19 investigators for all variables ranged from 99.7 to 100%. ICC was > 0.90 for all observers. Inter-observer variability for resting and exercise variables was for TRV = 3.8 to 2.4%, E = 5.7 to 8.3%, e' = 6 to 6.5%, RVOT Act = 9.7 to 12, LVOT VTI = 7.4 to 9.6%, S' = 2.9 to 2.9% and TAPSE = 5.3 to 8%. Moderate inter-observer variability was found for resting and peak exercise RV FAC (15 to 16%). LVEF revealed lower resting and peak exercise variability of 7.6 and 9%. CONCLUSIONS: When performed in expert centers EDE is a reproducible tool for the assessment of the right heart and the pulmonary circulation.


Asunto(s)
Ecocardiografía Doppler/normas , Ventrículos Cardíacos/diagnóstico por imagen , Circulación Pulmonar/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Derecha/diagnóstico , Función Ventricular Derecha/fisiología , Anciano , Prueba de Esfuerzo , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Curva ROC , Sístole , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Izquierda/fisiología
6.
J Am Soc Echocardiogr ; 34(2): 176-184, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33139140

RESUMEN

BACKGROUND: Transthoracic echocardiograms (TTEs) account for approximately half of U.S. spending on cardiac imaging. We developed an electronic medical record (EMR)-based decision-support algorithm for TTE ordering and hypothesized that it would increase the appropriateness of TTE orders. METHODS: This prospective observational study was performed at the Veterans Affairs Ann Arbor Healthcare System. From October to December 2016 (preintervention), consecutive TTEs ordered in the inpatient, outpatient, and emergency department settings were included. In May 2017, a decision-support algorithm was incorporated into the EMR, giving immediate feedback to providers. Chart review was performed for TTEs ordered from June to August 2017 (early intervention) and from June to August 2018 (late intervention). Appropriateness was determined based on the 2011 appropriate use criteria for echocardiography. RESULTS: Appropriate TTE orders increased from 87.6% preintervention to 94.5% at early intervention (z = 0.00018) but decreased to 90.0% at late intervention (z = 0.51, compared with preintervention). Among patients with no previous TTEs in our system, 95.3% of TTEs were appropriate, compared with 87.7% of TTEs for patients with prior TTEs within 30 days prior (odds ratio = 2.85; 95% CI, 1.18-6.31; P = .005). CONCLUSIONS: The EMR algorithm initially increased the percentage of appropriate TTEs, but this effect decayed over time. Further study is needed to develop EMR-based interventions that will have lasting impacts on provider ordering patterns.


Asunto(s)
Registros Electrónicos de Salud , Adhesión a Directriz , Ecocardiografía , Humanos , Pautas de la Práctica en Medicina , Estudios Prospectivos
7.
JACC Case Rep ; 2(1): 82-85, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34316970

RESUMEN

Dyspnea in the postpartum period can be a symptom of a wide range of causes spanning normal pregnancy to life-threatening pathology. We describe a case of acute postpartum heart failure with preserved systolic function in the absence of pre-eclampsia or prior cardiovascular disease. (Level of Difficulty: Beginner.).

8.
Am J Cardiol ; 124(5): 812-818, 2019 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31296366

RESUMEN

The relations between race and cardiac structure and function are incompletely understood. We hypothesized that race-specific differences in echocardiography measurements exist. We compared the relation between echocardiography measurements and race among 12,429 nonobese adults without known cardiovascular disease who underwent echocardiography. We compared measurements between whites (n = 10,508), blacks (n = 792), Asians (n = 628), Hispanics (n = 315), Native Americans (n = 34), and multiracial/other (n = 152) cohorts. Multivariate analysis compared measurements indexed to body surface area (BSA) between races and adjusted for variables including age, gender, and mean blood pressure. Mean age was 46.9 ± 17.4 years and 60.5% were women. After multivariable adjustment and using whites as a baseline, there were significant differences (p <0.05) in left ventricular end-diastolic diameter/BSA for blacks (-0.5 mm/m2), Asians (0.4 mm/m2), Hispanics (0.2 mm/m2), and multiracial/others (0.1 mm/m2); septal wall thickness/BSA for blacks (0.4 mm/m2) and Asians (0.1 mm/m2); posterior wall thickness/BSA for blacks (0.4 mm/m2), Asians (0.1 mm/m2), Hispanics (0.04 mm/m2), and multiracial/others (0.03 mm/m2); left atrial diameter/BSA for Asians (0.2 mm/m2), Hispanics (0.3 mm/m2), and multiracial/others (0.1 mm/m2); septal and lateral e' for blacks (-0.7 cm/s; -0.9 cm/s); and peak tricuspid regurgitation gradient for blacks (4.3 mm Hg) and Asians (-0.9 mm Hg). Race is associated with significant differences in left ventricular size, left atrial size, mitral annular velocity, and tricuspid regurgitation gradient. Normal reference ranges for echocardiography measurements should utilize racially diverse cohorts to prevent misclassification of echocardiography findings based on race.


Asunto(s)
Ecocardiografía/métodos , Corazón/anatomía & histología , Grupos Raciales , Función Ventricular Izquierda/fisiología , Función Ventricular Derecha/fisiología , Centros Médicos Académicos , Voluntarios Sanos , Corazón/diagnóstico por imagen , Pruebas de Función Cardíaca , Humanos , Persona de Mediana Edad , Valores de Referencia , Centros de Atención Terciaria
9.
Am J Cardiol ; 123(12): 2015-2021, 2019 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-30955867

RESUMEN

It is not clear whether there are differences in aortic dimensions by race. Our hypothesis was that race-specific differences in aortic size exist. We compared the relation between race and aortic dimensions among 15,295 adults without known risk factors for cardiovascular disease or aortic dilatation, who underwent clinically indicated transthoracic echocardiography. We compared inner edge-to-inner edge measurements between whites (n = 12,932), blacks (n = 958), Asians (n = 827), Hispanics (n = 366), Native Americans (n = 38), and others (n = 174). Multivariate analysis compared measurements indexed with body surface area (BSA) between races and adjusted for variables including age, gender, and mean blood pressure. Mean age was 49.9 ± 17.6 years, and 58.7% were female. On gender-specific comparisons, there were significant differences in aortic size between races (p <0.001 for each). Using whites as a baseline, multivariable analysis demonstrated that blacks had smaller BSA-indexed aortic sinus (-0.34 mm/m2, p <0.001) and ascending aorta (-0.43 mm/m2, p <0.001) dimensions; Asians had larger BSA-indexed aortic sinus (0.36 mm/m2, p <0.001), ascending aorta (0.41 mm/m2, p <0.001), and aortic arch (0.20 mm/m2, p = 0.002) dimensions; Hispanics had larger BSA-indexed aortic arch dimensions (0.15 mm/m2, p = 0.01); Native Americans had increased BSA-indexed aortic arch dimensions (0.32 mm/m2, p = 0.01); and other races had increased BSA-indexed aortic arch dimensions (0.11 mm/m2, p = 0.03). In a cohort without known risk factors for aortic dilatation, race is associated with significant differences in aortic dimensions. In conclusion, these findings suggest that reference ranges for aortic size should be established using racially diverse cohorts to prevent misdiagnosis of aortic dilatation based on race.


Asunto(s)
Aorta/anatomía & histología , Aorta/diagnóstico por imagen , Etnicidad , Población Blanca , Adulto , Anciano , Estudios de Cohortes , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia
10.
Echocardiography ; 36(5): 824-830, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30905085

RESUMEN

BACKGROUND: Guidelines provide normal ranges of left ventricular (LV) wall thicknesses (WT) without indexing. We hypothesized that indexing WT to body surface area (BSA) improves prognostic value. METHODS: We examined the relationship between WT and BSA in 9737 patients undergoing echocardiography without risk factors for LV hypertrophy other than obesity. We compared WT to BSA and examined the relationship of WT and LV mass index (LVMI) to mortality. RESULTS: There is a linear relationship between BSA and septal and posterior WT (r = 0.38, P < 0.001 for each). Higher quartiles of BSA were associated with increased WT (P < 0.001). After adjusting for age and gender, greater mean WT (MWT) (Hazards Ratio [HR] 1.10 per mm, 95% Confidence Interval [CI] 1.04-1.16, P = 0.001, C-statistic 0.66), LVMI (HR 1.01, 95% CI 1.001-1.01, P = 0.01, C-statistic 0.66), and indexed MWT (HR 1.34 per mm/m2 , 95% CI 1.23-1.47, P < 0.001, C-statistic 0.67) are each associated with increased mortality, with indexed MWT having the highest prognostic value. Each decile of indexed MWT ≥8th decile was associated with increased mortality compared to the 1st decile (P < 0.01 for each). Individuals with indexed MWT ≥8th decile (≥5.0 mm/m2 ) had increased adjusted mortality (HR 1.67, 95% CI 1.43-1.94, P < 0.001, C-statistic 0.67); this had improved prognostic value over guideline definitions of increased MWT (C-statistic 0.66) or LVMI (P = NS). CONCLUSIONS: We observe a linear relationship between BSA and WT. Indexing WT improves mortality prediction over LVMI and nonindexed WT. These findings support indexing WT to BSA.


Asunto(s)
Superficie Corporal , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Mortalidad , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico
11.
Heart Fail Clin ; 14(3): 443-465, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29966641

RESUMEN

The Right Heart International Network is a multicenter international study aiming to prospectively collect exercise Doppler echocardiography tests of the right heart pulmonary circulation unit (RHPCU) in large cohorts of healthy subjects, elite athletes, and individuals at risk of or with overt pulmonary hypertension. It is going to provide standardization of exercise stress echocardiography of RHPCU and explore the full physiopathologic response.


Asunto(s)
Ecocardiografía Doppler/métodos , Ecocardiografía de Estrés/métodos , Hipertensión Pulmonar/fisiopatología , Circulación Pulmonar/fisiología , Función Ventricular Derecha/fisiología , Ejercicio Físico/fisiología , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Masculino , Estudios Prospectivos , Proyectos de Investigación
12.
Eur Heart J Cardiovasc Imaging ; 19(6): 591-600, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29596561

RESUMEN

The EACVI/ASE/Industry Task Force to standardize deformation imaging prepared this consensus document to standardize definitions and techniques for using two-dimensional (2D) speckle tracking echocardiography (STE) to assess left atrial, right ventricular, and right atrial myocardial deformation. This document is intended for both the technical engineering community and the clinical community at large to provide guidance on selecting the functional parameters to measure and how to measure them using 2D STE.This document aims to represent a significant step forward in the collaboration between the scientific societies and the industry since technical specifications of the software packages designed to post-process echocardiographic datasets have been agreed and shared before their actual development. Hopefully, this will lead to more clinically oriented software packages which will be better tailored to clinical needs and will allow industry to save time and resources in their development.


Asunto(s)
Ecocardiografía/normas , Atrios Cardíacos/fisiopatología , Ventrículos Cardíacos/fisiopatología , Procesamiento de Imagen Asistido por Computador/normas , Guías de Práctica Clínica como Asunto/normas , Comités Consultivos , Técnicas de Imagen Cardíaca/normas , Ecocardiografía Tridimensional/normas , Femenino , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Estándares de Referencia , Sociedades Médicas
13.
J Card Fail ; 24(2): 90-100, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29051079

RESUMEN

INTRODUCTION: Coronary microvascular dysfunction (MVD) may contribute to the pathogenesis of heart failure with preserved ejection fraction (HFpEF). Using myocardial flow reserve (MFR) measured by positron emission tomography (PET) as an assessment of microvascular function, we hypothesized that abnormal MFR is associated with LV diastolic dysfunction (DD) and reduced LV and LA strain in patients with risk factors for HFpEF and normal epicardial perfusion on cardiac PET. METHODS AND RESULTS: Retrospective study of patients without heart failure who underwent cardiac rubidium-82 PET and echocardiography. Global MFR was calculated as the ratio of global stress to rest myocardial blood flow. Echocardiographic measures of diastolic function were recorded. Global longitudinal LA and LV strain were measured with a 2-dimensional speckle-tracking technique. Relationships among MFR and echocardiographic measures were assessed with linear regression, analysis of variance, and test for trend. Seventy-three patients (age 64 ± 11 years, 52% male) were identified with no epicardial perfusion defect on cardiac PET and an ejection fraction ≥50%. Decreased MFR was associated with LV DD (P = .02) and increased E/e', an estimation of LV filling pressure (low E/e' [<8] vs. high E/e' [>15], P < .001). MFR was associated with LA strain independent of age, gender, and common comorbidities (adjusted ß = 2.6% per unit MFR, P = 0.046); however, MFR was only marginally related to LV strain. CONCLUSIONS: In patients with risk factors for HFpEF, MVD assessed with MFR was associated with DD, increased estimated LV filling pressure, and abnormal LA strain.


Asunto(s)
Función del Atrio Izquierdo/fisiología , Ecocardiografía Doppler de Pulso/métodos , Reserva del Flujo Fraccional Miocárdico/fisiología , Atrios Cardíacos/fisiopatología , Insuficiencia Cardíaca Diastólica/fisiopatología , Pericardio/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Anciano , Femenino , Estudios de Seguimiento , Atrios Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca Diastólica/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
14.
Int J Cardiovasc Imaging ; 33(6): 847-855, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28168563

RESUMEN

Transthoracic echocardiography (TTE) is a practical and widely used tool for risk stratification in pulmonary arterial hypertension (PAH). We hypothesized that right atrial (RA) reservoir function, represented by peak RA systolic strain, correlates with invasive hemodynamic measurements and clinical outcomes in PAH. Patients with group 1 PAH who had TTE within 6 months of index PAH clinic visit and right heart catheterization were included in this retrospective study. Peak RA strain in the 2D apical 4-chamber view was measured with speckle-tracking software. The primary endpoint was a composite of prostacyclin initiation, lung transplantation, and death. RA strain was also measured in healthy control subjects. Among the 37 patients studied, 25 (68%) met the primary endpoint. RA strain was significantly lower among patients who met the primary endpoint than among those who did not (mean 20% vs. 33%, P = 0.002). Strain was lower in PAH patients than in controls (mean 24% vs. 35%, P = 0.0001). RA strain correlated negatively with hemodynamic data including RA pressure (R = -0.31), mean pulmonary arterial pressure (R = -0.33), and pulmonary vascular resistance (R = -0.39), and positively with cardiac index (R = 0.44). In receiver operating characteristic analysis to distinguish between patients meeting the primary endpoint and event-free survivors, RA strain was not significantly different from RA volume, right ventricular (RV) fractional area change, RV basal diameter, or right ventricular systolic pressure (area under the curve 0.82, 0.81, 0.83, 0.86, and 0.97, respectively). Our results demonstrate that RA strain is predictive of clinical outcomes in PAH. Further research is needed to determine if RA strain is independently associated with outcomes in this population.


Asunto(s)
Presión Arterial , Función del Atrio Derecho , Cateterismo Cardíaco , Ecocardiografía , Hipertensión Pulmonar/diagnóstico , Arteria Pulmonar/fisiopatología , Adulto , Anciano , Antihipertensivos/uso terapéutico , Área Bajo la Curva , Fenómenos Biomecánicos , Epoprostenol/uso terapéutico , Femenino , Humanos , Hipertensión Pulmonar/mortalidad , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/terapia , Trasplante de Pulmón , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Factores de Riesgo , Estrés Mecánico
16.
Eur J Cardiothorac Surg ; 50(2): 361-7, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26819292

RESUMEN

OBJECTIVES: The purpose of this study was to compare haemodynamics at rest and during exercise after clinically indicated aortic valve replacement (AVR) for aortic stenosis among patients randomly assigned to one of three haemodynamically excellent bioprostheses. METHODS: In a single-centre, prospective trial, 60 patients undergoing clinically indicated AVR were randomly assigned to Freestyle, Magna Ease or Trifecta bioprostheses. Six months after surgery, patients underwent supine bicycle stress echocardiography for the assessment of aortic valve haemodynamics. RESULTS: There were 5 protocol deviations from random valve assignments, and 4 patients did not return for follow-up stress echo, yielding a study group of 56 patients {17 Freestyle, 21 Magna Ease, 18 Trifecta; median age 70 [interquartile range (IQR) 63-78 years], 37 (66%) men}. There were no statistically significant differences between groups in valve size, concomitant procedures or exercise variables. Resting haemodynamics revealed significant differences between groups in mean gradient [Freestyle 7 (IQR 5-9) mmHg, Magna Ease 9 (IQR 7-11) mmHg, Trifecta 5 (IQR 4-8) mmHg; P = 0.04], effective orifice area (EOA) [2.5 (IQR 2.2-2.7), 2.1 (IQR 1.7-2.3) and 2.6 (IQR 2.3-2.8), respectively; P = 0.02] and EOA index [1.22 (IQR 1.11-1.32), 1.02 (IQR 0.89-1.14) and 1.31 (IQR 1.00-1.42), respectively; P = 0.03]; in each case, Trifecta had better haemodynamics compared with Magna Ease. With exercise, significant differences between groups were evident in peak velocity at 50 watts and peak exercise; mean gradient at 25 watts, 50 watts and maximal exercise; and EOA at 25 watts and at peak exercise; all with haemodynamic superiority of Trifecta compared with Magna Ease. There were no statistically significant differences between Trifecta and Freestyle haemodynamics at rest or with exercise. CONCLUSIONS: In a prospective, randomized study comparing haemodynamics after Freestyle, Magna Ease and Trifecta, all three valves exhibited good haemodynamics at rest and with exercise. There were small but significant differences between groups, with favourable haemodynamics associated with Trifecta compared to Magna Ease, and no significant differences between Trifecta and Freestyle. The Trifecta valve appears to offer haemodynamics similar to a stentless valve without the technical complexity of stentless valve implantation. CLINICALTRIALSGOV IDENTIFIER: NCT01635244.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Ejercicio Físico/psicología , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía Doppler , Ecocardiografía de Estrés , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad
17.
Am J Cardiol ; 116(7): 1128-31, 2015 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-26279109

RESUMEN

Takotsubo cardiomyopathy (TC) is believed to be an increasingly diagnosed syndrome; however, data on its incidence are limited. The purpose of this study was to determine the reported incidence of TC in the United States and to examine its trend over several years. Data was obtained from the Nationwide Inpatient Sample, created by the Agency for Healthcare Research and Quality, for each of the years from 2006 to 2012. Hospital discharges with principal diagnosis of TC, identified using Internal Classification of Diseases, Ninth Revision, code 429.83, were included. We tabulated estimated total numbers of discharges, incidence per 100,000 persons, mean length of stay, inhospital death rates, and diagnoses stratified by age group and gender. The reported incidence of TC based on principal diagnosis at hospital discharge increased significantly over the study period, with 315 cases ± 43 (standard error) in 2006 and 6,230 cases ± 232 (standard error) in 2012 (p <0.001 for trend). Mean length of hospital stay was stable over the study period (3.4 days in 2006 vs 3.6 days in 2012; p = 0.74 for trend). The diagnosis was most frequent in patients aged 65 to 84 years (50% of all diagnoses in 2012), followed by those aged 45 to 64 years (39% of all diagnoses in 2012). Women accounted for >90% of diagnoses throughout the study period. In conclusion, the reported incidence of TC has increased significantly from 2006 to 2012, most likely because of increasing recognition of the syndrome.


Asunto(s)
Predicción , Sistema de Registros , Cardiomiopatía de Takotsubo/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Estados Unidos/epidemiología , Adulto Joven
18.
J Am Soc Echocardiogr ; 28(2): 183-93, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25623220

RESUMEN

Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard.


Asunto(s)
Comités Consultivos , Ecocardiografía/normas , Procesamiento de Imagen Asistido por Computador/normas , Guías de Práctica Clínica como Asunto/normas , Consenso , Europa (Continente) , Humanos , Estándares de Referencia , Sociedades Médicas , Estados Unidos
19.
Eur Heart J Cardiovasc Imaging ; 16(1): 1-11, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25525063

RESUMEN

Recognizing the critical need for standardization in strain imaging, in 2010, the European Association of Echocardiography (now the European Association of Cardiovascular Imaging, EACVI) and the American Society of Echocardiography (ASE) invited technical representatives from all interested vendors to participate in a concerted effort to reduce intervendor variability of strain measurement. As an initial product of the work of the EACVI/ASE/Industry initiative to standardize deformation imaging, we prepared this technical document which is intended to provide definitions, names, abbreviations, formulas, and procedures for calculation of physical quantities derived from speckle tracking echocardiography and thus create a common standard.


Asunto(s)
Consenso , Ecocardiografía/normas , Procesamiento de Imagen Asistido por Computador/normas , Disfunción Ventricular Izquierda/diagnóstico por imagen , Comités Consultivos , Europa (Continente) , Humanos , Industrias , Estándares de Referencia , Sociedades Médicas
20.
Echocardiography ; 31(8): 947-55, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24446589

RESUMEN

BACKGROUND: We have developed new universal strain software (USS) that can be used to perform speckle tracking of any Digital Imaging and Communications in Medicine (DICOM) image, regardless of the ultrasound system used to obtain it. METHODS: Fifty patients prospectively underwent echocardiography immediately prior to cardiac catheterization. Biplane peak global longitudinal strain (GLS), peak systolic longitudinal strain rate (SSR), peak early diastolic longitudinal strain rate (DSR), and peak early diastolic circumferential strain rate (DCSR) were determined using conventional strain software (CSS) that uses raw data, and using the new USS applied to DICOM images. RESULTS: Universal strain software correlated with CSS for GLS (r = 0.78, P < 0.001), SSR (r = 0.78, P < 0.001), DSR (r = 0.54, P < 0.001), and DCSR (r = 0.43, P = 0.019). GLS and SSR using USS correlated with left ventricular ejection fraction (LVEF) (r = -0.67 and -0.71, respectively) as well as using CSS (r = -0.66 and -0.71). Patients with diastolic dysfunction had significantly lower DSR (0.61 vs. 0.87/sec, P = 0.02) and DCSR (0.89 vs. 1.23/sec, P = 0.03), and less negative GLS (-10.8 vs. -16.1%, P = 0.002) using USS in all patients, as well as among those with LVEF ≥ 50%. Receiver-operating characteristic (ROC) analysis for detection of diastolic dysfunction revealed a sensitivity and specificity of 82% and 83% for DCSR < 1.09/sec (area under the curve [AUC = 0.80]) and 85% and 83% for GLS > -13.7% (AUC = 0.84) using USS. CONCLUSION: Universal strain software can be used to accurately assess LV systolic and diastolic function using speckle tracking echocardiography.


Asunto(s)
Algoritmos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Programas Informáticos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Diástole , Módulo de Elasticidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Validación de Programas de Computación , Estrés Mecánico , Volumen Sistólico , Sístole , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA