Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Interv Neuroradiol ; : 15910199241248479, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38706147

RESUMEN

OBJECTIVE: There are few studies on flow diverters with diameters >5 mm. We present our preliminary experience with the 5.5-8 mm Derivo Embolization Device (DED) implants for the treatment of cerebral aneurysms. METHODS: A consecutive series of 26 patients (median age: 60 years) treated for 32 aneurysms in 26 procedures was retrospectively analyzed for procedural characteristics, complications, and mid-term angiographic results. RESULTS: The median aneurysm size was 10.5 mm, 2 of 30 (6%) aneurysms were ruptured and 9 (28%) had a fusiform or dissecting morphology. DED implantation was performed in the internal carotid artery in 18 of 26 (69%) procedures and in the vertebrobasilar artery in 8 (31%). Device deployment failed in 1 (4%) procedure. The 7 and 8 mm implants were successfully deployed in 5 cases. Additional balloon angioplasty or stent implantation was performed in 3 (12%) cases to improve wall apposition. Complications included 1 (4%) major stroke and 2 (8%) minor strokes. Angiographic follow up at a mean of 6 months showed complete occlusion in 8 of30 (27%) aneurysms and favorable occlusion in 14 (47%). CONCLUSIONS: The use of large diameter DEDs was safe and feasible. The mid-term occlusion rates are acceptable considering the complex subset of aneurysms studied. Further studies are warranted to define the indications for large-diameter DEDs and to evaluate their long-term efficacy.

2.
J Neurointerv Surg ; 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38569886

RESUMEN

BACKGROUND: This multicenter study evaluated the safety and efficacy of coated flow diverters (cFDs) for the treatment of ruptured intracranial aneurysms. METHODS: Consecutive patients treated with different cFDs for ruptured aneurysms under tirofiban at eight neurovascular centers between 2016 and 2023 were retrospectively analyzed. The majority of patients were loaded with dual antiplatelet therapy after the treatment. Aneurysm occlusion was determined using the O'Kelly-Marotta (OKM) grading scale. Primary outcome measures were major procedural complications and aneurysmal rebleeding during hospitalization. RESULTS: The study included 60 aneurysms (posterior circulation: 28 (47%)) with a mean size of 5.8±4.7 mm. Aneurysm morphology was saccular in 28 (47%), blister-like in 12 (20%), dissecting in 13 (22%), and fusiform in 7 (12%). Technical success was 100% with a mean of 1.1 cFDs implanted per aneurysm. Adjunctive coiling was performed in 11 (18%) aneurysms. Immediate contrast retention was observed in 45 (75%) aneurysms. There was 1 (2%) major procedural complication (a major stroke, eventually leading to death) and no aneurysmal rebleeding. A good outcome (modified Rankin Scale 0-2) was achieved in 40 (67%) patients. At a mean follow-up of 6 months, 27/34 (79%) aneurysms were completely occluded (OKM D), 3/34 (9%) had an entry remnant (OKM C), and 4/34 (12%) had residual filling (OKM A or B). There was 1 (3%) severe in-stent stenosis during follow-up that was treated with balloon angioplasty. CONCLUSIONS: Treatment of ruptured aneurysms with cFDs was reasonably safe and efficient and thus represents a valid treatment option, especially for complex cases.

3.
Radiology ; 311(1): e232714, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38625012

RESUMEN

Background Errors in radiology reports may occur because of resident-to-attending discrepancies, speech recognition inaccuracies, and large workload. Large language models, such as GPT-4 (ChatGPT; OpenAI), may assist in generating reports. Purpose To assess effectiveness of GPT-4 in identifying common errors in radiology reports, focusing on performance, time, and cost-efficiency. Materials and Methods In this retrospective study, 200 radiology reports (radiography and cross-sectional imaging [CT and MRI]) were compiled between June 2023 and December 2023 at one institution. There were 150 errors from five common error categories (omission, insertion, spelling, side confusion, and other) intentionally inserted into 100 of the reports and used as the reference standard. Six radiologists (two senior radiologists, two attending physicians, and two residents) and GPT-4 were tasked with detecting these errors. Overall error detection performance, error detection in the five error categories, and reading time were assessed using Wald χ2 tests and paired-sample t tests. Results GPT-4 (detection rate, 82.7%;124 of 150; 95% CI: 75.8, 87.9) matched the average detection performance of radiologists independent of their experience (senior radiologists, 89.3% [134 of 150; 95% CI: 83.4, 93.3]; attending physicians, 80.0% [120 of 150; 95% CI: 72.9, 85.6]; residents, 80.0% [120 of 150; 95% CI: 72.9, 85.6]; P value range, .522-.99). One senior radiologist outperformed GPT-4 (detection rate, 94.7%; 142 of 150; 95% CI: 89.8, 97.3; P = .006). GPT-4 required less processing time per radiology report than the fastest human reader in the study (mean reading time, 3.5 seconds ± 0.5 [SD] vs 25.1 seconds ± 20.1, respectively; P < .001; Cohen d = -1.08). The use of GPT-4 resulted in lower mean correction cost per report than the most cost-efficient radiologist ($0.03 ± 0.01 vs $0.42 ± 0.41; P < .001; Cohen d = -1.12). Conclusion The radiology report error detection rate of GPT-4 was comparable with that of radiologists, potentially reducing work hours and cost. © RSNA, 2024 See also the editorial by Forman in this issue.


Asunto(s)
Radiología , Humanos , Estudios Retrospectivos , Radiografía , Radiólogos , Confusión
4.
Sci Rep ; 14(1): 6154, 2024 03 14.
Artículo en Inglés | MEDLINE | ID: mdl-38486099

RESUMEN

Intra-arterial nimodipine administration is a widely used rescue therapy for cerebral vasospasm. Although it is known that its effect sets in with delay, there is little evidence in current literature. Our aim was to prove that the maximal vasodilatory effect is underestimated in direct angiographic controls. We reviewed all cases of intra-arterial nimodipine treatment for subarachnoid hemorrhage-related cerebral vasospasm between January 2021 and December 2022. Inclusion criteria were availability of digital subtraction angiography runs before and after nimodipine administration and a delayed run for the most affected vessel at the end of the procedure to decide on further escalation of therapy. We evaluated nimodipine dose, timing of administration and vessel diameters. Delayed runs were performed in 32 cases (19 patients) with a mean delay of 37.6 (± 16.6) min after nimodipine administration and a mean total nimodipine dose of 4.7 (± 1.2) mg. Vessel dilation was more pronounced in delayed vs. immediate controls, with greater changes in spastic vessel segments (n = 31: 113.5 (± 78.5%) vs. 32.2% (± 27.9%), p < 0.0001) vs. non-spastic vessel segments (n = 32: 23.1% (± 13.5%) vs. 13.3% (± 10.7%), p < 0.0001). In conclusion intra-arterially administered nimodipine seems to exert a delayed vasodilatory effect, which should be considered before escalation of therapy.


Asunto(s)
Hemorragia Subaracnoidea , Vasoespasmo Intracraneal , Humanos , Nimodipina/farmacología , Vasodilatadores/uso terapéutico , Vasoespasmo Intracraneal/diagnóstico por imagen , Vasoespasmo Intracraneal/tratamiento farmacológico , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/tratamiento farmacológico , Angiografía de Substracción Digital
5.
Rofo ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38479409

RESUMEN

PURPOSE: Due to the increasing number of COVID-19 infections since spring 2020 the patient care workflow underwent changes in Germany. To minimize face-to-face exposure and reduce infection risk, non-time-critical elective medical procedures were postponed. Since ultrasound examinations include non-time-critical elective examinations and often can be substituted by other imaging modalities not requiring direct patient contact, the number of examinations has declined significantly. The aim of this study is to quantify the baseline number of ultrasound examinations in the years before, during, and in the early post-pandemic period of the COVID-19 pandemic (since January 2015 to September 2023), and to measure the number of examinations at different German university hospitals. MATERIALS AND METHODS: The number of examinations was assessed based on a web-based database at all participating clinics at the indicated time points. RESULTS: N = 288 562 sonographic examinations from four sites were included in the present investigation. From January 2020 to June 2020, a significantly lower number of examinations of n = 591.21 vs. 698.43 (p = 0.01) per month and included center was performed. Also, excluding the initial pandemic period until June 2020, significantly fewer ultrasound examinations were performed compared to pre-pandemic years 648.1 vs. 698.4 (p < 0.05), per month and included center, while here differences between the individual centers were observed. In the late phase of the pandemic (n = 681.96) and in the post-pandemic phase (as defined by the WHO criteria from May 2023; n = 739.95), the number of sonographic examinations returned to pre-pandemic levels. CONCLUSION: The decline in the number of sonographic examinations caused by the COVID-19 pandemic was initially largely intentional and can be illustrated quantitatively. After an initial abrupt decline in sonographic examinations, the pre-pandemic levels could not be reached for a long time, which could be due to restructuring of patient care and follow-up treatment. In the post-pandemic phase, the pre-pandemic level has been achieved again. The reasons for a prolonged reduction in ultrasound examinations are discussed in this article. KEY POINTS: · During the pandemic, significantly fewer ultrasound examinations were performed in the included centers.. · The number of examinations could not be reach the pre-pandemic level for a long time, which could be due to restructuring of patient care and follow-up treatment.. · Identifying causes for sonographic exam reduction is crucial in pandemic preparedness to uphold healthcare quality and continuity for all patients.. · The prolonged decline in sonographic examinations during the pandemic does not represent a lasting trend, as evidenced by the return to pre-pandemic levels..

6.
Bioengineering (Basel) ; 11(3)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38534481

RESUMEN

CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

7.
World Neurosurg ; 183: e210-e217, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38101543

RESUMEN

OBJECTIVE: The Pipeline Vantage Embolization Device is a fourth-generation flow diverter with an antithrombotic coating and a reduced profile compared to previous Pipeline versions. The objective of this study was to evaluate the procedural feasibility, safety, and efficacy of this device. METHODS: The Pipe-VADER study was designed as a retrospective, observational study of consecutive patients treated with the Vantage at 3 neurovascular centers. Patient and aneurysm characteristics, procedural parameters, early complications, and extent of postinterventional contrast retention were analyzed on an intention-to-treat basis. RESULTS: Twenty-eight patients with 31 aneurysms (median size: 5.0 mm, posterior circulation: 4 [12.9%], ruptured: 5 [16.1%]) were included. The technical success rate was 100%, with multiple stents used in 4/30 (13.3%) procedures. Of the 30 procedures, adjunctive coiling was performed in 3 (10.0%) and balloon angioplasty in 2 (6.7%). Median procedure time was 62 minutes. Procedural ischemic stroke occured in 4 (13.3%) cases, whereof 2 were major strokes (6.6%). There were no hemorrhagic complications. Initial contrast retention was observed in 29/31 (93.5%) aneurysms. All 27 overstented side vessels were patent at the end of the procedure. Short-term follow-up (median: 5 months) showed complete and favorable occlusion rates of 70% (14/20) and 80% (16/20), respectively. CONCLUSIONS: The new Pipeline Vantage appears to be safe and feasible for the treatment of intracranial aneurysms and warrants further evaluation.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Embolización Terapéutica/métodos , Angiografía Cerebral/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Stents , Procedimientos Endovasculares/métodos , Estudios de Seguimiento
10.
Front Endocrinol (Lausanne) ; 14: 1098898, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37274340

RESUMEN

Purpose: The bone marrow's iodine uptake in dual-energy CT (DECT) is elevated in malignant disease. We aimed to investigate the physiological range of bone marrow iodine uptake after intravenous contrast application, and examine its dependence on vBMD, iodine blood pool, patient age, and sex. Method: Retrospective analysis of oncological patients without evidence of metastatic disease. DECT examinations were performed on a spectral detector CT scanner in portal venous contrast phase. The thoracic and lumbar spine were segmented by a pre-trained neural network, obtaining volumetric iodine concentration data [mg/ml]. vBMD was assessed using a phantomless, CE-certified software [mg/cm3]. The iodine blood pool was estimated by ROI-based measurements in the great abdominal vessels. A multivariate regression model was fit with the dependent variable "median bone marrow iodine uptake". Standardized regression coefficients (ß) were calculated to assess the impact of each covariate. Results: 678 consecutive DECT exams of 189 individuals (93 female, age 61.4 ± 16.0 years) were evaluated. AI-based segmentation provided volumetric data of 97.9% of the included vertebrae (n=11,286). The 95th percentile of bone marrow iodine uptake, as a surrogate for the upper margin of the physiological distribution, ranged between 4.7-6.4 mg/ml. vBMD (p <0.001, mean ß=0.50) and portal vein iodine blood pool (p <0.001, mean ß=0.43) mediated the strongest impact. Based thereon, adjusted reference values were calculated. Conclusion: The bone marrow iodine uptake demonstrates a distinct profile depending on vBMD, iodine blood pool, patient age, and sex. This study is the first to provide the adjusted reference values.


Asunto(s)
Inteligencia Artificial , Yodo , Humanos , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Médula Ósea/diagnóstico por imagen , Valores de Referencia , Tomografía Computarizada por Rayos X
11.
Quant Imaging Med Surg ; 13(2): 1058-1070, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36819239

RESUMEN

Background: Diagnosing a coronavirus disease 2019 (COVID-19) infection with high specificity in chest computed tomography (CT) imaging is considered possible due to distinctive imaging features of COVID-19 pneumonia. Since other viral non-COVID pneumonia show mostly a different distribution pattern, it is reasonable to assume that the patterns observed caused by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are a consequence of its genetically encoded molecular properties when interacting with the respiratory tissue. As more mutations of the initial SARS-CoV-2 wild-type with varying aggressiveness have been detected in the course of 2021, it became obvious that its genome is in a state of transformation and therefore a potential modification of the specific morphological appearance in CT may occur. The aim of this study was to quantitatively analyze the morphological differences of the SARS-CoV-2-B.1.1.7 mutation and wildtype variant in CT scans of the thorax. Methods: We analyzed a dataset of 140 patients, which was divided into pneumonias caused by n=40 wildtype variants, n=40 B.1.1.7 variants, n=20 bacterial pneumonias, n=20 viral (non-COVID) pneumonias, and a test group of n=20 unremarkable CT examinations of the thorax. Semiautomated 3D segmentation of the lung tissue was performed for quantification of lung pathologies. The extent, ratio, and specific distribution of inflammatory affected lung tissue in each group were compared in a multivariate group analysis. Results: Lung segmentation revealed significant difference between the extent of ground glass opacities (GGO) or consolidation comparing SARS-CoV-2 wild-type and B.1.1.7 variant. Wildtype and B.1.1.7 variant showed both a symmetric distribution pattern of stage-dependent GGO and consolidation within matched COVID-19 stages. Viral non-COVID pneumonias had significantly fewer consolidations than the bacterial, but also than the COVID-19 B.1.1.7 variant groups. Conclusions: CT based segmentation showed no significant difference between the morphological appearance of the COVID-19 wild-type variant and the SARS-CoV-2 B.1.1.7 mutation. However, our approach allowed a semiautomatic quantification of bacterial and viral lung pathologies. Quantitative CT image analyses, such as the one presented, appear to be an important component of pandemic preparedness considering an organism with ongoing genetic change, to describe a potential arising change in CT morphological appearance of possible new upcoming COVID-19 variants of concern.

12.
Diagnostics (Basel) ; 13(3)2023 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-36766523

RESUMEN

Compressed sensing accelerates magnetic resonance imaging (MRI) acquisition by undersampling of the k-space. Yet, excessive undersampling impairs image quality when using conventional reconstruction techniques. Deep-learning-based reconstruction methods might allow for stronger undersampling and thus faster MRI scans without loss of crucial image quality. We compared imaging approaches using parallel imaging (SENSE), a combination of parallel imaging and compressed sensing (COMPRESSED SENSE, CS), and a combination of CS and a deep-learning-based reconstruction (CS AI) on raw k-space data acquired at different undersampling factors. 3D T2-weighted images of the lumbar spine were obtained from 20 volunteers, including a 3D sequence (standard SENSE), as provided by the manufacturer, as well as accelerated 3D sequences (undersampling factors 4.5, 8, and 11) reconstructed with CS and CS AI. Subjective rating was performed using a 5-point Likert scale to evaluate anatomical structures and overall image impression. Objective rating was performed using apparent signal-to-noise and contrast-to-noise ratio (aSNR and aCNR) as well as root mean square error (RMSE) and structural-similarity index (SSIM). The CS AI 4.5 sequence was subjectively rated better than the standard in several categories and deep-learning-based reconstructions were subjectively rated better than conventional reconstructions in several categories for acceleration factors 8 and 11. In the objective rating, only aSNR of the bone showed a significant tendency towards better results of the deep-learning-based reconstructions. We conclude that CS in combination with deep-learning-based image reconstruction allows for stronger undersampling of k-space data without loss of image quality, and thus has potential for further scan time reduction.

13.
Eur Radiol ; 33(6): 4280-4291, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36525088

RESUMEN

OBJECTIVES: Differentiation between COVID-19 and community-acquired pneumonia (CAP) in computed tomography (CT) is a task that can be performed by human radiologists and artificial intelligence (AI). The present study aims to (1) develop an AI algorithm for differentiating COVID-19 from CAP and (2) evaluate its performance. (3) Evaluate the benefit of using the AI result as assistance for radiological diagnosis and the impact on relevant parameters such as accuracy of the diagnosis, diagnostic time, and confidence. METHODS: We included n = 1591 multicenter, multivendor chest CT scans and divided them into AI training and validation datasets to develop an AI algorithm (n = 991 CT scans; n = 462 COVID-19, and n = 529 CAP) from three centers in China. An independent Chinese and German test dataset of n = 600 CT scans from six centers (COVID-19 / CAP; n = 300 each) was used to test the performance of eight blinded radiologists and the AI algorithm. A subtest dataset (180 CT scans; n = 90 each) was used to evaluate the radiologists' performance without and with AI assistance to quantify changes in diagnostic accuracy, reporting time, and diagnostic confidence. RESULTS: The diagnostic accuracy of the AI algorithm in the Chinese-German test dataset was 76.5%. Without AI assistance, the eight radiologists' diagnostic accuracy was 79.1% and increased with AI assistance to 81.5%, going along with significantly shorter decision times and higher confidence scores. CONCLUSION: This large multicenter study demonstrates that AI assistance in CT-based differentiation of COVID-19 and CAP increases radiological performance with higher accuracy and specificity, faster diagnostic time, and improved diagnostic confidence. KEY POINTS: • AI can help radiologists to get higher diagnostic accuracy, make faster decisions, and improve diagnostic confidence. • The China-German multicenter study demonstrates the advantages of a human-machine interaction using AI in clinical radiology for diagnostic differentiation between COVID-19 and CAP in CT scans.


Asunto(s)
COVID-19 , Infecciones Comunitarias Adquiridas , Aprendizaje Profundo , Neumonía , Humanos , Inteligencia Artificial , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos , Prueba de COVID-19
14.
Quant Imaging Med Surg ; 12(11): 5156-5170, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36330188

RESUMEN

Background: The extent of lung involvement in coronavirus disease 2019 (COVID-19) pneumonia, quantified on computed tomography (CT), is an established biomarker for prognosis and guides clinical decision-making. The clinical standard is semi-quantitative scoring of lung involvement by an experienced reader. We aim to compare the performance of automated deep-learning- and threshold-based methods to the manual semi-quantitative lung scoring. Further, we aim to investigate an optimal threshold for quantification of involved lung in COVID pneumonia chest CT, using a multi-center dataset. Methods: In total 250 patients were included, 50 consecutive patients with RT-PCR confirmed COVID-19 from our local institutional database, and another 200 patients from four international datasets (n=50 each). Lung involvement was scored semi-quantitatively by three experienced radiologists according to the established chest CT score (CCS) ranging from 0-25. Inter-rater reliability was reported by the intraclass correlation coefficient (ICC). Deep-learning-based segmentation of ground-glass and consolidation was obtained by CT Pulmo Auto Results prototype plugin on IntelliSpace Discovery (Philips Healthcare, The Netherlands). Threshold-based segmentation of involved lung was implemented using an open-source tool for whole-lung segmentation under the presence of severe pathologies (R231CovidWeb, Hofmanninger et al., 2020) and consecutive quantitative assessment of lung attenuation. The best threshold was investigated by training and testing a linear regression of deep-learning and threshold-based results in a five-fold cross validation strategy. Results: Median CCS among 250 evaluated patients was 10 [6-15]. Inter-rater reliability of the CCS was excellent [ICC 0.97 (0.97-0.98)]. Best attenuation threshold for identification of involved lung was -522 HU. While the relationship of deep-learning- and threshold-based quantification was linear and strong (r2 deep-learning vs. threshold=0.84), both automated quantification methods translated to the semi-quantitative CCS in a non-linear fashion, with an increasing slope towards higher CCS (r2 deep-learning vs. CCS= 0.80, r2 threshold vs. CCS=0.63). Conclusions: The manual semi-quantitative CCS underestimates the extent of COVID pneumonia in higher score ranges, which limits its clinical usefulness in cases of severe disease. Clinical implementation of fully automated methods, such as deep-learning or threshold-based approaches (best threshold in our multi-center dataset: -522 HU), might save time of trained personnel, abolish inter-reader variability, and allow for truly quantitative, linear assessment of COVID lung involvement.

15.
J Clin Neurosci ; 102: 5-12, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35687921

RESUMEN

Vaccine-induced immune thrombotic thrombocytopenia (VITT) with cerebral venous thrombosis (CVST) is an improbable (0.0005%), however potentially lethal complication after ChAdOx1 vaccination. On the other hand, headache is among the most frequent side effects of ChAdOx1 (29.3%). In September 2021, the American Heart Association (AHA) suggested a diagnostic workflow to facilitate risk-adapted use of imaging resources for patients with neurological symptoms after ChAdOx1. We aimed to evaluate the AHA workflow in a retrospective patient cohort presenting at four primary care hospitals in Germany for neurological complaints after ChAdOx1. Scientific literature was screened for case reports of VITT with CVST after ChAdOx1, published until September 1st, 2021. One-hundred-thirteen consecutive patients (77 female, mean age 38.7 +/- 11.9 years) were evaluated at our institutes, including one case of VITT with CVST. Further 228 case reports of VITT with CVST are published in recent literature, which share thrombocytopenia (225/227 reported) and elevated d-dimer levels (100/101 reported). The AHA workflow would have recognized all VITT cases with CVST (100% sensitivity), the number needed to diagnose (NND) was 1:113. Initial evaluation of thrombocytopenia or elevated d-dimer levels would have lowered the NND to 1:68, without cost of sensitivity. Hence, we suggest that in case of normal thrombocyte and d-dimer levels, the access to further diagnostics should be limited by the established clinical considerations regardless of vaccination history.


Asunto(s)
Vacunas contra la COVID-19 , Trombosis de los Senos Intracraneales , Adulto , Algoritmos , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Femenino , Humanos , Masculino , Uso Significativo , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis de los Senos Intracraneales/diagnóstico por imagen , Trombosis de los Senos Intracraneales/etiología
16.
Front Cardiovasc Med ; 9: 835732, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35391852

RESUMEN

Objectives: To evaluate the usefulness of spectral detector CT (SDCT)-derived pulmonary perfusion maps and pulmonary parenchyma characteristics for the semiautomated classification of pulmonary hypertension (PH). Methods: A total of 162 consecutive patients with right heart catheter (RHC)-proven PH of different aetiologies as defined by the current ESC/ERS guidelines who underwent CT pulmonary angiography (CTPA) on SDCT and 20 patients with an invasive rule-out of PH were included in this retrospective study. Semiautomatic lung segmentation into normal and malperfused areas based on iodine density (ID) as well as automatic, virtual non-contrast-based emphysema quantification were performed. Corresponding volumes, histogram features and the ID SkewnessPerfDef-Emphysema-Index (δ-index) accounting for the ratio of ID distribution in malperfused lung areas and the proportion of emphysematous lung parenchyma were computed and compared between groups. Results: Patients with PH showed a significantly greater extent of malperfused lung areas as well as stronger and more homogenous perfusion defects. In group 3 and 4 patients, ID skewness revealed a significantly more homogenous ID distribution in perfusion defects than in all other subgroups. The δ-index allowed for further subclassification of subgroups 3 and 4 (p < 0.001), identifying patients with chronic thromboembolic PH (CTEPH, subgroup 4) with high accuracy (AUC: 0.92, 95%-CI, 0.85-0.99). Conclusion: Abnormal pulmonary perfusion in PH can be detected and quantified by semiautomated SDCT-based pulmonary perfusion maps. ID skewness in malperfused lung areas, and the δ-index allow for a classification of PH subgroups, identifying groups 3 and 4 patients with high accuracy, independent of reader expertise.

17.
Eur Radiol ; 32(9): 6427-6434, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35389049

RESUMEN

OBJECTIVES: The aim of this study was to evaluate whether simple 2D measurements in axial slices of head and neck CT examinations correlate with generally established measurements of body composition in abdominal CT at the height of the third lumbar vertebra and thus allow for an estimation of muscle and fat masses. METHODS: One hundred twenty-two patients who underwent concurrent CT of the head and neck and the abdomen between July 2016 and July 2020 were retrospectively included. For a subset of 30 patients, additional bioelectrical impedance analysis (BIA) was available. Areas of paraspinal muscles at the height of the third (C3) and fifth cervical vertebrae (C5) as well as the total cross-sectional area at the height of C3 and at the submandibular level were correlated with the results of abdominal measurements and BIA. Furthermore, intra- and interreader variabilities of all measurements were assessed. RESULTS: Regarding adipose tissue, good correlations were found between the total cross-sectional area of the patient's body at the submandibular level and at the height of C3 between both abdominal measurements and BIA results (r = 0.8-0.92; all p < 0.001). Regarding muscle, the total paraspinal muscle area at the height of C3 and C5 showed strong correlations with abdominal measurements and moderate to strong correlations with BIA results (r = 0.44-0.80; all p < 0.001), with the muscle area on C5 yielding slightly higher correlations. CONCLUSIONS: Body composition information can be obtained with comparable reliability from head and neck CT using simple biplanar measurements as from abdominal CT. KEY POINTS: • The total paraspinal muscle area at the height of C3 and C5 correlates strongly with abdominal muscle mass. • The total cross-sectional area at the submandibular level and at the height of C3 shows good correlations with abdominal fat mass. • The described measurements facilitate a rapid, opportunistic assessment of relevant body composition parameters.


Asunto(s)
Composición Corporal , Tomografía Computarizada por Rayos X , Abdomen , Composición Corporal/fisiología , Impedancia Eléctrica , Humanos , Músculo Esquelético , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
18.
Diagnostics (Basel) ; 12(3)2022 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-35328224

RESUMEN

Virtual non-calcium (VNCa) images from dual-energy computed tomography (DECT) have shown high potential to diagnose bone marrow disease of the spine, which is frequently disguised by dense trabecular bone on conventional CT. In this study, we aimed to define reference values for VNCa bone marrow images of the spine in a large-scale cohort of healthy individuals. DECT was performed after resection of a malignant skin tumor without evidence of metastatic disease. Image analysis was fully automated and did not require specific user interaction. The thoracolumbar spine was segmented by a pretrained convolutional neuronal network. Volumetric VNCa data of the spine's bone marrow space were processed using the maximum, medium, and low calcium suppression indices. Histograms of VNCa attenuation were created for each exam and suppression setting. We included 500 exams of 168 individuals (88 female, patient age 61.0 ± 15.9). A total of 8298 vertebrae were segmented. The attenuation histograms' overlap of two consecutive exams, as a measure for intraindividual consistency, yielded a median of 0.93 (IQR: 0.88-0.96). As our main result, we provide the age- and sex-specific bone marrow attenuation profiles of a large-scale cohort of individuals with healthy trabecular bone structure as a reference for future studies. We conclude that artificial-intelligence-supported, fully automated volumetric assessment is an intraindividually robust method to image the spine's bone marrow using VNCa data from DECT.

19.
PLoS One ; 17(2): e0263261, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35113939

RESUMEN

PURPOSE: To evaluate the association between the coronavirus disease 2019 (COVID-19) and post-inflammatory emphysematous lung alterations on follow-up low-dose CT scans. METHODS: Consecutive patients with proven COVID-19 infection and a follow-up CT were retrospectively reviewed. The severity of pulmonary involvement was classified as mild, moderate and severe. Total lung volume, emphysema volume and the ratio of emphysema/-to-lung volume were quantified semi-automatically and compared inter-individually between initial and follow-up CT and to a control group of healthy, age- and sex-matched patients. Lung density was further assessed by drawing circular regions of interest (ROIs) into non-affected regions of the upper lobes. RESULTS: A total of 32 individuals (mean age: 64 ± 13 years, 12 females) with at least one follow-up CT (mean: 52 ± 66 days, range: 5-259) were included. In the overall cohort, total lung volume, emphysema volume and the ratio of lung-to-emphysema volume did not differ significantly between the initial and follow-up scans. In the subgroup of COVID-19 patients with > 30 days of follow-up, the emphysema volume was significantly larger as compared to the subgroup with a follow-up < 30 days (p = 0.045). Manually measured single ROIs generally yielded lower attenuation values prior to COVID-19 pneumonia, but the difference was not significant between groups (all p > 0.05). CONCLUSION: COVID-19 patients with a follow-up CT >30 days showed significant emphysematous lung alterations. These findings may help to explain the long-term effect of COVID-19 on pulmonary function and warrant validation by further studies.


Asunto(s)
COVID-19/complicaciones , Enfisema Pulmonar/complicaciones , Enfisema Pulmonar/diagnóstico por imagen , Dosis de Radiación , SARS-CoV-2/genética , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , COVID-19/virología , Estudios de Casos y Controles , Femenino , Estudios de Seguimiento , Humanos , Pulmón/fisiopatología , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad , Enfisema Pulmonar/fisiopatología , Estudios Retrospectivos
20.
Eur Radiol ; 32(5): 2901-2911, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34921619

RESUMEN

OBJECTIVES: To demonstrate the feasibility of an automated, non-invasive approach to estimate bone marrow (BM) infiltration of multiple myeloma (MM) by dual-energy computed tomography (DECT) after virtual non-calcium (VNCa) post-processing. METHODS: Individuals with MM and monoclonal gammopathy of unknown significance (MGUS) with concurrent DECT and BM biopsy between May 2018 and July 2020 were included in this retrospective observational study. Two pathologists and three radiologists reported BM infiltration and presence of osteolytic bone lesions, respectively. Bone mineral density (BMD) was quantified CT-based by a CE-certified software. Automated spine segmentation was implemented by a pre-trained convolutional neural network. The non-fatty portion of BM was defined as voxels > 0 HU in VNCa. For statistical assessment, multivariate regression and receiver operating characteristic (ROC) were conducted. RESULTS: Thirty-five patients (mean age 65 ± 12 years; 18 female) were evaluated. The non-fatty portion of BM significantly predicted BM infiltration after adjusting for the covariable BMD (p = 0.007, r = 0.46). A non-fatty portion of BM > 0.93% could anticipate osteolytic lesions and the clinical diagnosis of MM with an area under the ROC curve of 0.70 [0.49-0.90] and 0.71 [0.54-0.89], respectively. Our approach identified MM-patients without osteolytic lesions on conventional CT with a sensitivity and specificity of 0.63 and 0.71, respectively. CONCLUSIONS: Automated, AI-supported attenuation assessment of the spine in DECT VNCa is feasible to predict BM infiltration in MM. Further, the proposed method might allow for pre-selecting patients with higher pre-test probability of osteolytic bone lesions and support the clinical diagnosis of MM without pathognomonic lesions on conventional CT. KEY POINTS: • The retrospective study provides an automated approach for quantification of the non-fatty portion of bone marrow, based on AI-supported spine segmentation and virtual non-calcium dual-energy CT data. • An increasing non-fatty portion of bone marrow is associated with a higher infiltration determined by invasive biopsy after adjusting for bone mineral density as a control variable (p = 0.007, r = 0.46). • The non-fatty portion of bone marrow might support the clinical diagnosis of multiple myeloma when conventional CT images are negative (sensitivity 0.63, specificity 0.71).


Asunto(s)
Médula Ósea , Mieloma Múltiple , Anciano , Inteligencia Artificial , Médula Ósea/diagnóstico por imagen , Médula Ósea/patología , Calcio , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/patología , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA