Resultados 1 - 17 de 17
Filtrar
1.
Sensors (Basel) ; 24(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38894105

RESUMEN

Combining proton and phosphorus magnetic resonance spectroscopy offers a unique opportunity to study the oxidative and glycolytic components of metabolism in working muscle. This paper presents a 7 T proton calf coil design that combines dipole and loop elements to achieve the high performance necessary for detecting metabolites with low abundance and restricted visibility, specifically lactate, while including the option of adding a phosphorus array. We investigated the transmit, receive, and parallel imaging performance of three transceiver dipoles with six pair-wise overlap-decoupled standard or twisted pair receive-only coils. With a higher SNR and more efficient transmission decoupling, standard loops outperformed twisted pair coils. The dipoles with standard loops provided a four-fold-higher image SNR than a multinuclear reference coil comprising two proton channels and 32% more than a commercially available 28-channel proton knee coil. The setup enabled up to three-fold acceleration in the right-left direction, with acceptable g-factors and no visible aliasing artefacts. Spectroscopic phantom measurements revealed a higher spectral SNR for lactate with the developed setup than with either reference coil and fewer restrictions in voxel placement due to improved transmit homogeneity. This paper presents a new use case for dipoles and highlights their advantages for the integration in multinuclear calf coils.


Asunto(s)
Imagen por Resonancia Magnética , Músculo Esquelético , Fantasmas de Imagen , Humanos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/química , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Relación Señal-Ruido , Ácido Láctico/química , Ácido Láctico/metabolismo
2.
Sci Rep ; 14(1): 2811, 2024 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-38307928

RESUMEN

Magnetic Resonance Imaging (MRI) is a major medical imaging modality, which is non-invasive and provides unique soft tissue contrast without ionizing radiation. The successful completion of MRI exams critically depends on patient compliance, and, thus patient comfort. The design, appearance and usability of local MRI radiofrequency (RF) coils potentially influences the patients' perception of the exam. However, systematic investigations and empirical evidence for these aspects are missing. A questionnaire specifically evaluating the impact of RF coils on patient comfort in MRI would be a valuable addition to clinical studies comparing the performance of novel flexible RF coils with standard rigid coils. This paper describes the development of such a questionnaire in the scope of a citizen science (CS) initiative conducted with a group of students at the upper secondary school level. In this work, the CS initiative is presented in the format of a case report and its impact on scientific projects and the students' education is outlined. The resulting questionnaire is made available in German and English so as to be directly applicable by researchers working on the clinical evaluation of novel RF coils or the comfort evaluation of specific hardware setups in general.


Asunto(s)
Ciencia Ciudadana , Humanos , Ondas de Radio , Imagen por Resonancia Magnética/métodos , Radiación Ionizante , Percepción , Fantasmas de Imagen , Diseño de Equipo
3.
Z Med Phys ; 2023 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-37258388

RESUMEN

Flexible form-fitting radiofrequency coils provide high signal-to-noise ratio (SNR) for magnetic resonance imaging (MRI), and in array configuration large anatomical areas of interest can be covered. We propose a modular system - "ModFlex"- of flexible lightweight 4-channel coaxial coil arrays for 3 T MRI. We investigated the performance difference between commercial reference coils and 8- and 16-channel ModFlex receive-only array systems. In vivo, six anatomical targets in four regions of interest - the neck, the ankle, the spine and the hip - were imaged with the novel coil array system. The versatility of ModFlex and the robustness of the coil characteristics for different use cases is demonstrated. We measured an SNR gain for 4 out of 6 and similar SNR for 2 out of 6 anatomical target regions as compared to commercial reference coils. Parallel imaging capabilities are comparable to standard coils in hip and neck imaging, but ModFlex outperforms standard coils in ankle and spine imaging. High SNR combined with high acceleration possibilities enables faster imaging workflows and/or high-resolution MR acquisitions. The coil's versatility is beneficial for use cases with varying subject sizes and could improve patient comfort.

4.
Invest Radiol ; 58(11): 799-810, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37227137

RESUMEN

BACKGROUND: Breast cancer, the most common malignant cancer in women worldwide, is typically diagnosed by x-ray mammography, which is an unpleasant procedure, has low sensitivity in women with dense breasts, and involves ionizing radiation. Breast magnetic resonance imaging (MRI) is the most sensitive imaging modality and works without ionizing radiation, but is currently constrained to the prone imaging position due to suboptimal hardware, therefore hampering the clinical workflow. OBJECTIVES: The aim of this work is to improve image quality in breast MRI, to simplify the clinical workflow, shorten measurement time, and achieve consistency in breast shape with other procedures such as ultrasound, surgery, and radiation therapy. MATERIALS AND METHODS: To this end, we propose "panoramic breast MRI"-an approach combining a wearable radiofrequency coil for 3 T breast MRI (the "BraCoil"), acquisition in the supine position, and a panoramic visualization of the images. We demonstrate the potential of panoramic breast MRI in a pilot study on 12 healthy volunteers and 1 patient, and compare it to the state of the art. RESULTS: With the BraCoil, we demonstrate up to 3-fold signal-to-noise ratio compared with clinical standard coils and acceleration factors up to 6 × 4. Panoramic visualization of supine breast images reduces the number of slices to be viewed by a factor of 2-4. CONCLUSIONS: Panoramic breast MRI allows for high-quality diagnostic imaging and facilitated correlation to other diagnostic and interventional procedures. The developed wearable radiofrequency coil in combination with dedicated image processing has the potential to improve patient comfort while enabling more time-efficient breast MRI compared with clinical coils.


Asunto(s)
Neoplasias de la Mama , Dispositivos Electrónicos Vestibles , Femenino , Humanos , Proyectos Piloto , Mama/diagnóstico por imagen , Mama/patología , Imagen por Resonancia Magnética/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología
6.
IEEE Trans Med Imaging ; 40(4): 1267-1278, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33439836

RESUMEN

Magnetic resonance has become a backbone of medical imaging but suffers from inherently low sensitivity. This can be alleviated by improved radio frequency (RF) coils. Multi-turn multi-gap coaxial coils (MTMG-CCs) introduced in this work are flexible, form-fitting RF coils extending the concept of the single-turn single-gap CC by introducing multiple cable turns and/or gaps. It is demonstrated that this enables free choice of the coil diameter, and thus, optimizing it for the application to a certain anatomical site, while operating at the self-resonance frequency. An equivalent circuit for MTMG-CCs is modeled to predict their resonance frequency. Possible configurations regarding size, number of turns and gaps, and cable types for different B 0 field strengths are calculated. Standard copper wire loop coils (SCs) and flexible CCs made from commercial coaxial cable were fabricated as receive-only coils for 3 T and transmit/receive coils at 7 T with diameters between 4 and 15 cm. Electromagnetic simulations are used to investigate the currents on MTMG-CCs, and demonstrate comparable specific absorption rate of 7 T CCs and SCs. Signal-to-noise ratio (SNR), transmit efficiency, and active detuning performance of CCs were compared in bench tests and MR experiments. For the form-fitted receive-only CCs at 3 T no significant SNR degradation was found as compared to flat SCs on a balloon phantom. Form-fitted transmit/receive CCs at 7 T showed higher transmit efficiency and SNR. MTMG-CCs can be sized to optimize sensitivity, are flexible and lightweight, and could therefore enable the fabrication of wearable coils with improved patient comfort.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Diseño de Equipo , Humanos , Fantasmas de Imagen , Relación Señal-Ruido
7.
Sensors (Basel) ; 19(15)2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31357545

RESUMEN

The goal of this work is to further improve positron emission tomography (PET) attenuation correction and magnetic resonance (MR) sensitivity for head and neck applications of PET/MR. A dedicated 24-channel receive-only array, fully-integrated with a hydraulic system to move a transmission source helically around the patient and radiofrequency (RF) coil array, is designed, implemented, and evaluated. The device enables the calculation of attenuation coefficients from PET measurements at 511 keV including the RF coil and the particular patient. The RF coil design is PET-optimized by minimizing photon attenuation from coil components and housing. The functionality of the presented device is successfully demonstrated by calculating the attenuation map of a water bottle based on PET transmission measurements; results are in excellent agreement with reference values. It is shown that the device itself has marginal influence on the static magnetic field B0 and the radiofrequency transmit field B1 of the 3T PET/MR system. Furthermore, the developed RF array is shown to outperform a standard commercial 16-channel head and neck coil in terms of signal-to-noise ratio (SNR) and parallel imaging performance. In conclusion, the presented hardware enables accurate calculation of attenuation maps for PET/MR systems while improving the SNR of corresponding MR images in a single device without degrading the B0 and B1 homogeneity of the scanner.


Asunto(s)
Cabeza/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen Multimodal , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido
8.
PLoS One ; 13(11): e0206963, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30383832

RESUMEN

PURPOSE: The purpose of this work is the design, implementation and evaluation of a mechanically flexible receive-only coil array for magnetic resonance imaging (MRI) at 3 T that can be applied to various target organs and provides high parallel imaging performance. METHODS: A 23-channel array was designed based on a rigid-flex printed circuit board (PCB). The flexible multi-layer part contains the copper traces forming the coil elements. The rigid part of the PCB houses the solder joints and lumped elements. The coil housing consists of rigid caps mounted above the rigid parts. Adhesive PTFE sheets cover all flexible parts. The developed array was tested on the bench as well as in phantom and in vivo MRI experiments employing parallel imaging acceleration factors up to six. RESULTS: Efficient mutual decoupling between receive elements and detuning between receive array and body coil was achieved. An increased signal-to-noise ratio in comparison to commercial reference coils is demonstrated, especially in regions close to the developed array and for high parallel imaging acceleration factors. Exemplary in vivo images of head, ankle, knee, shoulder and hand are presented. CONCLUSION: Based on high sensitivity close to the array and low g-factors, this flexible coil is well suited for studies of occipital and temporal cortex, as well as musculoskeletal targets like knee, ankle, elbow and wrist.


Asunto(s)
Diseño de Equipo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Humanos , Articulaciones/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen
9.
J Magn Reson ; 296: 47-59, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30205313

RESUMEN

A flexible transceiver array based on transmission line resonators (TLRs) combining the advantages of coil arrays with the possibility of form-fitting targeting cardiac MRI at 7 T is presented. The design contains 12 elements which are fabricated on a flexible substrate with rigid PCBs attached on the center of each element to place the interface components, i.e. transmit/receive (T/R) switch, power splitter, pre-amplifier and capacitive tuning/matching circuitry. The mutual coupling between elements is cancelled using a decoupling ring-based technique. The performance of the developed array is evaluated by 3D electromagnetic simulations, bench tests, and MR measurements using phantoms. Efficient inter-element decoupling is demonstrated in flat configuration on a box-shaped phantom (Sij < -19 dB), and bent on a human torso phantom (Sij < -16 dB). Acceleration factors up to 3 can be employed in bent configuration with reasonable g-factors (<1.7) in an ROI at the position of the heart. The array enables geometrical conformity to bodies within a large range of size and shape and is compatible with parallel imaging and parallel transmission techniques.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Simulación por Computador , Campos Electromagnéticos , Corazón/diagnóstico por imagen , Humanos , Aumento de la Imagen , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido , Torso/diagnóstico por imagen
10.
Sci Rep ; 8(1): 6211, 2018 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-29670177

RESUMEN

13C magnetic resonance spectroscopy is a viable, non-invasive method to study cell metabolism in skeletal muscles. However, MR sensitivity of 13C is inherently low, which can be overcome by applying a higher static magnetic field strength together with radiofrequency coil arrays instead of single loop coils or large volume coils, and 1H decoupling, which leads to a simplified spectral pattern. 1H-decoupled 13C-MRS requires RF coils which support both, 1H and 13C, Larmor frequencies with sufficient electromagnetic isolation between the pathways of the two frequencies. We present the development, evaluation, and first in vivo measurement with a 7 T 3-channel 13C and 4-channel 1H transceiver array optimized for 1H-decoupled 13C-MRS in the posterior human calf muscles. To ensure minimal cross-coupling between 13C and 1H arrays, several strategies were combined: mutual magnetic flux was minimized by coil geometry, two LCC traps were inserted into each 13C element, and band-pass and low-pass filters were integrated along the signal pathways. The developed coil array was successfully tested in phantom and in vivo MR experiments, showing a simplified spectral pattern and increase in signal-to-noise ratio of approximately a factor 2 between non-decoupled and 1H-decoupled spectra in a glucose phantom and the human calf muscle.


Asunto(s)
Espectroscopía de Resonancia Magnética con Carbono-13 , Músculo Esquelético/química , Espectroscopía de Protones por Resonancia Magnética , Ondas de Radio , Espectroscopía de Resonancia Magnética con Carbono-13/métodos , Campos Electromagnéticos , Fenómenos Electromagnéticos , Glucógeno/análisis , Glucógeno/química , Humanos , Fantasmas de Imagen , Espectroscopía de Protones por Resonancia Magnética/métodos
11.
NMR Biomed ; 31(6): e3905, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29578260

RESUMEN

Exercise studies investigating the metabolic response of calf muscles using 31 P MRS are usually performed with a single knee angle. However, during natural movement, the distribution of workload between the main contributors to force, gastrocnemius and soleus is influenced by the knee angle. Hence, it is of interest to measure the respective metabolic response of these muscles to exercise as a function of knee angle using localized spectroscopy. Time-resolved multivoxel 31 P MRS at 7 T was performed simultaneously in gastrocnemius medialis and soleus during rest, plantar flexion exercise and recovery in 12 healthy volunteers. This experiment was conducted with four different knee angles. PCr depletions correlated negatively with knee angle in gastrocnemius medialis, decreasing from 79±14 % (extended leg) to 35±23 %(∼40°), and positively in soleus, increasing from 20±21 % to 36±25 %; differences were significant. Linear correlations were found between knee angle and end-exercise PCr depletions in gastrocnemius medialis (R2 =0.8) and soleus (R2 =0.53). PCr recovery times and end-exercise pH changes that correlated with PCr depletion were consistent with the literature in gastrocnemius medialis and differences between knee angles were significant. These effects were less pronounced in soleus and not significant for comparable PCr depletions. Maximum oxidative capacity calculated for all knee angles was in excellent agreement with the literature and showed no significant changes between different knee angles. In conclusion, these findings confirm that plantar flexion exercise with a straight leg is a suitable paradigm, when data are acquired from gastrocnemius only (using either localized MRS or small surface coils), and that activation of soleus requires the knee to be flexed. The present study comprises a systematic investigation of the effects of the knee angle on metabolic parameters, measured with dynamic multivoxel 31 P MRS during muscle exercise and recovery, and the findings should be used in future study design.


Asunto(s)
Ejercicio Físico/fisiología , Articulación de la Rodilla/fisiología , Espectroscopía de Resonancia Magnética , Fósforo/química , Rango del Movimiento Articular/fisiología , Adulto , Femenino , Humanos , Concentración de Iones de Hidrógeno , Modelos Lineales , Masculino , Oxidación-Reducción , Fosfocreatina/metabolismo
12.
Magn Reson Med ; 79(1): 588-592, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28295563

RESUMEN

PURPOSE: To demonstrate a dedicated setup for ultrahigh resolution MR imaging of the human finger in vivo. METHODS: A radiofrequency coil was designed for optimized signal homogeneity and sensitivity in the finger at ultrahigh magnetic field strength (7 T), providing high measurement sensitivity. Imaging sequences (2D turbo-spin echo (TSE) and 3D magnetization-prepared rapid acquisition gradient echo (MPRAGE)) were adapted for high spatial resolution and good contrast of different tissues in the finger, while keeping acquisition time below 10 minutes. Data was postprocessed to display finger structures in three dimensions. RESULTS: 3D MPRAGE data with isotropic resolution of 200 µm, along with 2D TSE images with in-plane resolutions of 58 × 78 µm2 and 100 × 97 µm2 , allowed clear identification of various anatomical features such as bone and bone marrow, tendons and annular ligaments, cartilage, arteries and veins, nerves, and Pacinian corpuscles. CONCLUSION: Using this dedicated finger coil at 7 T, together with adapted acquisition sequences, it is possible to depict the internal structures of the human finger in vivo within patient-compatible measurement time. It may serve as a tool for diagnosis and treatment monitoring in pathologies ranging from inflammatory or erosive joint diseases to injuries of tendons and ligaments to nervous or vascular disorders in the finger. Magn Reson Med 79:588-592, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Dedos/diagnóstico por imagen , Imagen por Resonancia Magnética , Simulación por Computador , Humanos , Imagenología Tridimensional , Espectroscopía de Resonancia Magnética , Modelos Anatómicos , Fantasmas de Imagen , Ondas de Radio , Relación Señal-Ruido
13.
Neuroimage ; 150: 262-269, 2017 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-28254457

RESUMEN

PURPOSE: To validate a novel setup for concurrent TMS/fMRI in the human motor cortex based on a dedicated, ultra-thin, multichannel receive MR coil positioned between scalp and TMS system providing greatly enhanced sensitivity compared to the standard birdcage coil setting. METHODS: A combined TMS/fMRI design was applied over the primary motor cortex based on 1Hz stimulation with stimulation levels of 80%, 90%, 100%, and 110% of the individual active motor threshold, respectively. Due to the use of a multichannel receive coil we were able to use multiband-accelerated (MB=2) EPI sequences for the acquisition of functional images. Data were analysed with SPM12 and BOLD-weighted signal intensity time courses were extracted in each subject from two local maxima (individual functional finger tapping localiser, fixed MNI coordinate of the hand knob) next to the hand area of the primary motor cortex (M1) and from the global maximum. RESULTS: We report excellent image quality without noticeable signal dropouts or image distortions. Parameter estimates in the three peak voxels showed monotonically ascending activation levels over increasing stimulation intensities. Across all subjects, mean BOLD signal changes for 80%, 90%, 100%, 110% of the individual active motor threshold were 0.43%, 0.63%, 1.01%, 2.01% next to the individual functional finger tapping maximum, 0.73%, 0.91%, 1.34%, 2.21% next to the MNI-defined hand knob and 0.88%, 1.09%, 1.65%, 2.77% for the global maximum, respectively. CONCLUSION: Our results show that the new setup for concurrent TMS/fMRI experiments using a dedicated MR coil array allows for high-sensitivity fMRI particularly at the site of stimulation. Contrary to the standard birdcage approach, the results also demonstrate that the new coil can be successfully used for multiband-accelerated EPI acquisition. The gain in flexibility due to the new coil can be easily combined with neuronavigation within the MR scanner to allow for accurate targeting in TMS/fMRI experiments.


Asunto(s)
Mapeo Encefálico/instrumentación , Imagen por Resonancia Magnética/instrumentación , Corteza Motora/fisiología , Estimulación Magnética Transcraneal/instrumentación , Adulto , Mapeo Encefálico/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Estimulación Magnética Transcraneal/métodos
14.
Magn Reson Med ; 77(3): 921-927, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-26914656

RESUMEN

PURPOSE: Separate measurements are required when investigating multiple exercising muscles with singlevoxel-localized dynamic 31 P-MRS. With multivoxel spectroscopy, 31 P-MRS time-series spectra are acquired from multiple independent regions during one exercise-recovery experiment with the same time resolution as for singlevoxel measurements. METHODS: Multiple independently selected volumes were localized using temporally interleaved semi-LASER excitations at 7T. Signal loss caused by mutual saturation from shared excitation or refocusing slices was quantified at partial and full overlap, and potential contamination was investigated in phantom measurements. During an exercise-recovery experiment both gastrocnemius medialis and soleus of two healthy volunteers were measured using multivoxel acquisitions with a total TR of 6 s, while avoiding overlap of excitation slices. RESULTS: Signal reduction by shared adiabatic refocusing slices selected 1 s after the preceding voxel was between 10% (full overlap) and 20% (half overlap), in a phantom measurement. In vivo data were acquired from both muscles within the same exercise experiment, with 13-18% signal reduction. Spectra show phosphocreatine, inorganic phosphate, adenosine-triposphate, phosphomonoesters, and phosphodiesters. CONCLUSION: Signal decrease was relatively low compared to the 2-fold increase in information. The approach could help to improve the understanding in metabolic research and is applicable to other organs and nuclei. Magn Reson Med 77:921-927, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Algoritmos , Ejercicio Físico/fisiología , Espectroscopía de Resonancia Magnética/métodos , Músculo Esquelético/fisiología , Compuestos de Fósforo/metabolismo , Isótopos de Fósforo/farmacocinética , Femenino , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Imagen Molecular/métodos , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Magn Reson ; 273: 65-72, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27750073

RESUMEN

A novel design scheme for monolithic transmission line resonators (TLRs) is presented - the multi-turn multi-gap TLR (MTMG-TLR) design. The MTMG-TLR design enables the construction of TLRs with multiple turns and multiple gaps. This presents an additional degree of freedom in tuning self-resonant TLRs, as their resonance frequency is fully determined by the coil geometry (e.g. diameter, number of turns, conductor width, etc.). The novel design is evaluated at 4.7T and 7T by simulations and experiments, where it is demonstrated that MTMG-TLRs can be used for MRI, and that the B1 distribution of MTMG-TLRs strongly depends on the number and distribution of turns. A comparison to conventional loop coils revealed that the B1 performance of MTMG-TLRs is comparable to a loop coil with the same mean diameter; however, lower 10g SAR values were found for MTMG-TLRs. The MTMG-TLR design is expected to bring most benefits at high static field, where it allows for independent size and frequency selection, which cannot be achieved with standard TLR design. However, it also enables more accurate geometric optimization at low static field. Thereby, the MTMG-TLR design preserves the intrinsic advantages of TLRs, i.e. mechanical flexibility, high SAR efficiency, mass production, and coil miniaturization.

16.
Magn Reson Med ; 73(6): 2376-89, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25046817

RESUMEN

PURPOSE: To enhance sensitivity and coverage for calf muscle studies, a novel, form-fitted, three-channel phosphorus-31 ((31) P), two-channel proton ((1) H) transceiver coil array for 7 T MR imaging and spectroscopy is presented. METHODS: Electromagnetic simulations employing individually generated voxel models were performed to design a coil array for studying nonpathological muscle metabolism. Static phase combinations of the coil elements' transmit fields were optimized based on homogeneity and efficiency for several voxel models. The best-performing design was built and tested both on phantoms and in vivo. RESULTS: Simulations revealed that a shared conductor array for (31) P provides more robust interelement decoupling and better homogeneity than an overlap array in this configuration. A static B1 (+) shim setting that suited various calf anatomies was identified and implemented. Simulations showed that the (31) P array provides signal-to-noise ratio (SNR) benefits over a single loop and a birdcage coil of equal radius by factors of 3.2 and 2.6 in the gastrocnemius and by 2.5 and 2.0 in the soleus muscle. CONCLUSION: The performance of the coil in terms of B1 (+) and achievable SNR allows for spatially localized dynamic (31) P spectroscopy studies in the human calf. The associated higher specificity with respect to nonlocalized measurements permits distinguishing the functional responses of different muscles.


Asunto(s)
Aumento de la Imagen/instrumentación , Pierna , Imagen por Resonancia Magnética/instrumentación , Músculo Esquelético/anatomía & histología , Adulto , Simulación por Computador , Diseño de Equipo , Femenino , Voluntarios Sanos , Humanos , Masculino , Fantasmas de Imagen , Isótopos de Fósforo
17.
Magn Reson Med ; 73(4): 1669-81, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24753115

RESUMEN

PURPOSE: This article presents a novel inductive decoupling technique for form-fitting coil arrays of monolithic transmission line resonators, which target biomedical applications requiring high signal-to-noise ratio over a large field of view to image anatomical structures varying in size and shape from patient to patient. METHODS: Individual transmission line resonator elements are mutually decoupled using magnetic flux sharing by overlapping annexes. This decoupling technique was evaluated by electromagnetic simulations and bench measurements for two- and four-element arrays, comparing single- and double-gap transmission line resonator designs, combined either with a basic capacitive matching scheme or inductive pickup loop matching. The best performing array was used in 7T MRI experiments demonstrating its form-fitting ability and parallel imaging potential. RESULTS: The inductively matched double-gap transmission line resonator array provided the best decoupling efficiency in simulations and bench measurements (<-15 dB). The decoupling and parallel imaging performance proved robust against mechanical deformation of the array. CONCLUSION: The presented decoupling technique combines the robustness of conventional overlap decoupling regarding coil loading and operating frequency with the extended field of view of nonoverlapped coils. While demonstrated on four-element arrays, it can be easily expanded to fabricate readily decoupled form-fitting 2D arrays with an arbitrary number of elements in a single etching process.


Asunto(s)
Electrónica Médica/instrumentación , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Transductores , Diseño de Equipo , Análisis de Falla de Equipo , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS