Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Front Pharmacol ; 15: 1412188, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38948466

RESUMEN

The management of neurological disorders heavily relies on neurotherapeutic drugs, but notable concerns exist regarding their possible negative effects on reproductive health. Traditional preclinical models often fail to accurately predict reprotoxicity, highlighting the need for more physiologically relevant systems. Organoid models represent a promising approach for concurrently studying neurotoxicity and reprotoxicity, providing insights into the complex interplay between neurotherapeutic drugs and reproductive systems. Herein, we have examined the molecular mechanisms underlying neurotherapeutic drug-induced reprotoxicity and discussed experimental findings from case studies. Additionally, we explore the utility of organoid models in elucidating the reproductive complications of neurodrug exposure. Have discussed the principles of organoid models, highlighting their ability to recapitulate neurodevelopmental processes and simulate drug-induced toxicity in a controlled environment. Challenges and future perspectives in the field have been addressed with a focus on advancing organoid technologies to improve reprotoxicity assessment and enhance drug safety screening. This review underscores the importance of organoid models in unraveling the complex relationship between neurotherapeutic drugs and reproductive health.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38917652

RESUMEN

Dried Blood Spots (DBS) revolutionize therapeutic drug monitoring using LC-MS for the precise quantification of cardiovascular drugs (CDs), enabling personalized treatment adapted to patient-specific pharmacokinetics with minimal invasiveness. This study aims to achieve simultaneous quantification of eight CDs in DBS, overcoming physicochemical challenges. A two-step protein precipitation method was used for simple and precise sample preparation. The drugs were analyzed using LC-MS/MS in ESI positive-ion mode, showing high sensitivity and linearity, with a correlation coefficient (r2) exceeding 0.999, after being separated on a reversed-phase chromatography by gradient elution of DW-acetonitrile containing 0.1 % formic acid + 2 mM ammonium formate. The validation results indicate good selectivity, with no observed matrix effect and carry-over. The intra- and inter-day accuracy and precision were within 6 % for most drugs, except for digoxin and deslanoside at low therapeutic levels where the variation was within 20 %. Stability tests confirmed suitable DBS handling and storage conditions, indicating drug stability for at least 30 days at room temperature. The analysis of whole spot has demonstrated remarkable precision and reliability in all target drugs. The analysis of 3 mm internal diameter discs, punched in and out of DBS, presumed to contain 3 µL of blood, showed acceptable accuracy for most drugs, with less polar drugs like digoxin and deslanoside showing lower accuracy, indicating a need for further correction due to non-uniform drug distribution. Consequently, the developed LC-MS/MS method enables the quantification of multiple CDs in a single DBS analysis, while suggesting the potential for accuracy-based analysis.


Asunto(s)
Fármacos Cardiovasculares , Pruebas con Sangre Seca , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Pruebas con Sangre Seca/métodos , Humanos , Reproducibilidad de los Resultados , Modelos Lineales , Cromatografía Liquida/métodos , Fármacos Cardiovasculares/sangre , Fármacos Cardiovasculares/farmacocinética , Límite de Detección , Monitoreo de Drogas/métodos
3.
Reprod Toxicol ; 128: 108628, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38848930

RESUMEN

Bisphenol A (BPA), a widespread environmental contaminant, poses concerns due to its disruptive effects on physiological functions of the uterine endometrium. In contrast, melatonin (MT) and Resveratrol (RSV) are under scrutiny for their potential protective roles against BPA-induced damage. For the efficacy and ethical concerns in the animal test, endometrial organoids, three-dimensional models mimicking endometrium, serve as crucial tools for unraveling the impact of environmental factors on reproductive health. This study aimed to comprehensively characterize the morphological, molecular and metabolic responses of porcine endometrial organoids to BPA and assess the potential protective effects of MT and RSV. Porcine uteri were prepared, digested with collagenase, mixed with Matrigel, and incubated at 38°C with 5 % CO2. Passaging involved dissociation through trypsin-EDTA treatment and subculturing. The culture medium was refreshed every 2-3 days. To investigate the environmental impact on reproductive health, endometrial organoids were treated with BPA (0.5 µM), MT (with/without BPA at 0.1 µM), and/or RSV (10 µM). Various molecular screening using gene expression, western blotting, immunofluorescence staining, and metabolites profiling were assessed the effects of BPA, MT, and RSV in terms of cell viability, morphology, reproductivity, and metabolism alteration in the endometrial organoids. As expected, BPA induced structural and molecular disruptions in organoids, affecting cytoskeletal proteins, Wnt/ß-catenin signaling, and epithelial/mesenchymal markers. It triggered oxidative stress and apoptotic pathways, altered miRNA expression, and disrupted the endocannabinoid system. The level of glucose, galactose, and essential amino acids were increased or decreased by approximately 1.5-3 times in BPA-treated groups compared to the control groups (p-value < 0.05), indicating metabolic changes. Moreover, MT and RSV treated groups exhibited protective effects, mitigating BPA-induced disruptions across multiple pathways. For the first time, our study models endometrial organoids, advancing understanding of environmental impacts on reproductive health.


Asunto(s)
Compuestos de Bencidrilo , Endometrio , Melatonina , Organoides , Fenoles , Resveratrol , Femenino , Compuestos de Bencidrilo/toxicidad , Fenoles/toxicidad , Resveratrol/farmacología , Animales , Organoides/efectos de los fármacos , Endometrio/efectos de los fármacos , Endometrio/metabolismo , Porcinos , Melatonina/farmacología , Antioxidantes/farmacología , Estrés Oxidativo/efectos de los fármacos
4.
Artículo en Inglés | MEDLINE | ID: mdl-38761469

RESUMEN

This study aims to establish an LC-MS/MS method to simultaneously analyze 11 antiepileptic drugs with a particular focus on maintaining accuracy while reducing the number of isotope-labeled internal standards employed for cost-effectiveness. By applying a water/acetonitrile gradient elution containing 0.1 % formic acid and 2 mM ammonium formate as the mobile phase, optimal sensitivity for the target drugs could be obtained in positive ESI mode in LC-MS/MS. After optimizing various extraction techniques, extraction with 70 % acetonitrile was selected as it provided good recoveries (>93 %) for all targets without matrix effects. Accuracies within 3 % were achieved from the combination of six internal standards, while accuracies of 5 % and 10 % were obtained by reducing the number of internal standards to four and two, respectively, for more economical analysis. The accuracy of the established method was maintained in hyperglycemia, hyperlipidemia, and hyperalbuminemia sera, suggesting that it can be successfully applied to individual serum samples with various properties.


Asunto(s)
Anticonvulsivantes , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Anticonvulsivantes/sangre , Anticonvulsivantes/análisis , Humanos , Reproducibilidad de los Resultados , Cromatografía Liquida/métodos , Modelos Lineales , Límite de Detección , Marcaje Isotópico/métodos , Cromatografía Líquida con Espectrometría de Masas
5.
Nat Commun ; 15(1): 2983, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38582860

RESUMEN

Akkermansia muciniphila has received great attention because of its beneficial roles in gut health by regulating gut immunity, promoting intestinal epithelial development, and improving barrier integrity. However, A. muciniphila-derived functional molecules regulating gut health are not well understood. Microbiome-secreted proteins act as key arbitrators of host-microbiome crosstalk through interactions with host cells in the gut and are important for understanding host-microbiome relationships. Herein, we report the biological function of Amuc_1409, a previously uncharacterised A. muciniphila-secreted protein. Amuc_1409 increased intestinal stem cell (ISC) proliferation and regeneration in ex vivo intestinal organoids and in vivo models of radiation- or chemotherapeutic drug-induced intestinal injury and natural aging with male mice. Mechanistically, Amuc_1409 promoted E-cadherin/ß-catenin complex dissociation via interaction with E-cadherin, resulting in the activation of Wnt/ß-catenin signaling. Our results demonstrate that Amuc_1409 plays a crucial role in intestinal homeostasis by regulating ISC activity in an E-cadherin-dependent manner and is a promising biomolecule for improving and maintaining gut health.


Asunto(s)
Verrucomicrobia , beta Catenina , Masculino , Ratones , Animales , beta Catenina/metabolismo , Verrucomicrobia/metabolismo , Intestinos , Cadherinas/metabolismo , Akkermansia
6.
Reproduction ; 167(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38112579

RESUMEN

In brief: Porcine endometrial organoids (EOs) were isolated and characterized, revealing distinctive features such as unique extracellular matrix formation, fusion into uterine bud-like structures, and facilitation of embryo elongation. The yield of EOs was significantly enhanced by cryopreservation medium supplemented with the rock inhibitor (Y-27632), resulting in reduced expression of apoptotic mRNAs and microRNAs. Abstract: Endometrial organoids (EOs) are acceptable models for understanding maternal-embryonic cross talk. This study was conducted to generate EOs and optimize their cryopreservation and provide coculture modeling with embryos. The endometrial tissues were used for culturing the organoids inside domes of Matrigel®. To improve the long-term storage of EOs, 10 µM ROCK inhibitor (RI) was added to the cryopreservation medium. Day 7 parthenogenetically activated embryos were cocultured with EOs or EO outgrowths, and embryonic cell numbers and embryo attachment were monitored. Spherical EOs 100-300 µm in size can be retrieved on day 7 of culture, and larger EOs, approximately 1.5 mm in diameter, can be maintained in the Matrigel® dome for 21 days. The nuclear expression of Ki67 indicates that more than 80% of EOs nuclei were proliferative. EOs exhibit unique novel characters such as formation of extracellular matrix and ability for fusion. RI increased the yield and quality of organoids after freezing or thawing. The cell number of cocultured embryos increased five-fold, and the proportion of trophoblast outgrowths increased seven-fold compared with those of control embryos. The embryos cultured with EO-conditioned medium showed a better attachment rate than the other models, and - for the first time - we report embryonic elongation. Immunofluorescence staining of the attached embryos showed CDX2 in the periphery of EOs outgrowths. The 3D assembly and cryopreservation of EOs was optimized, and EO coculture supported embryo attachment, trophoblast outgrowth, and elongation, which would provide a valuable tool for studying the intricate processes involved in porcine embryo implantation.


Asunto(s)
Implantación del Embrión , Quinasas Asociadas a rho , Animales , Porcinos , Trofoblastos , Embrión de Mamíferos , Técnicas de Cocultivo
7.
Molecules ; 28(22)2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-38005289

RESUMEN

Analytical methods based on the mass balance approach were developed for the purity evaluation of tetracycline hydrochloride, a representative salt compound used in pure veterinary drug analysis. The purity assignment method was used to quantify individual classes of impurities via independent analytical techniques. The mass fraction of the free base or salt form contained in a high-purity organic compound with a hydrochloride salt can be determined. The chloride content by ion chromatography-conductivity detector (IC-CD) and general classes of impurities, including structurally related impurities by liquid chromatography-ultraviolet (LC-UV) detector, water by Karl Fischer (KF) coulometric titration, residual solvents by headspace sampler gas chromatography/mass spectrometry (HS-GC/MS), and non-volatiles by thermogravimetric analyzer (TGA), were considered to calculate the purity of the mass fraction. The chloride content of the salt compound can be considered the main impurity in the mass fraction of the free base in the salt compound. A purity assay using quantitative nuclear magnetic resonance (q-NMR) as a direct determination method was performed to confirm the results of the mass balance method. The assigned purities of the tetracycline free form and its salt form in mass fraction were (898.80 ± 1.60) mg/g and (972.65 ± 1.58) mg/g, respectively, which are traceable to the international system of units (SI). Thus, the procedure for evaluating the purity of the free base and salt forms in the salt compound is newly demonstrated in this study.


Asunto(s)
Cloruros , Tetraciclina , Cromatografía Liquida/métodos , Cromatografía de Gases y Espectrometría de Masas
8.
Artículo en Inglés | MEDLINE | ID: mdl-37992562

RESUMEN

We describe the simultaneous quantification of six antiviral drugs in serum based on high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The target drugs-hydroxychloroquine, chloroquine, favipiravir, umifenovir, ritonavir, and lopinavir-were extracted and purified from serum with 75 % v/v methanol as the precipitant reagent. The six analytes were clearly separated within 15 min using gradient elution and mixed-mode stationary phase. The measurement accuracy and precision were assured by adopting isotopes as internal standards. The optimized measurement procedure was strictly validated in linearity, sensitivity, accuracy, and precision. To confirm the robustness of the method in matrix, the method was additionally applied to various types of serum, namely hyperlipidemic and hyperglycemic serum. The method was then applied to assess the stability of the drugs in serum in order to set sample handling and storage guides for laboratory testing. Lastly, the method was implemented in different LC-MS systems to confirm its applicability across similar equipment commonly used in clinical testing laboratories. The overall results show that the optimized protocol is suitable for the accurate, simultaneous quantification of the six antiviral drugs in serum, and it is anticipated to satisfactorily serve as a reference protocol for the analysis of a wide range of other antiviral drugs for drug monitoring with various purposes.


Asunto(s)
Antivirales , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Isótopos , Reproducibilidad de los Resultados
9.
Heliyon ; 9(1): e12684, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36685467

RESUMEN

We developed a method combining ultraviolet (UV) detection and integrated pulsed amperometric detection (IPAD) to simultaneously analyze eleutheroside B, eleutheroside E, chiisanoside, and sesamin. The gradient elution system allowed complete separation of all target components within 35 min, and showed limits of detection of 0.006-0.020 µg/mL and limits of quantification of 0.018-0.050 µg/mL. The linear regression coefficients of determination were 0.9990-0.9998. All inter- and intra-day precision values were below 4.89%, and the average recoveries were 97.79-104.40%. The developed approach exhibits excellent reproducibility, sensitivity, and selectivity without requiring any complicated pre-treatment, and is therefore expected to be helpful as a tool for establishing appropriate content criteria for Acanthopanax species.

10.
Artículo en Inglés | MEDLINE | ID: mdl-36469961

RESUMEN

Therapeutic drug monitoring (TDM) of cardiovascular drugs is essential to improve treatment efficacy and minimize toxicity because of the usage of multiple drugs with a very limited therapeutic range and the high pharmacokinetic variation in patients. We developed and validated a reliable and economical liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of seven cardiovascular drugs-procainamide, lidocaine, quinidine, deslanoside, digoxin, atorvastatin, and digitoxin-for clinical usage. Serum samples were prepared by simple protein precipitation with an organic solvent consisting of acetonitrile and methanol (2:1 v/v) and analyzed under optimized LC-MS/MS conditions. The chromatographic separations were accomplished within 15 min on a reversed-phase C18 column with a gradient elution of aqueous solvent and acetonitrile while maintaining 0.1 (v/v) % formic acid and 2 mM ammonium formate. The optimized MS/MS conditions in ESI-positive mode offered sufficient sensitivity for the seven cardiovascular drugs (LOQs between 0.5 and 1 ng/mL). This method was fully validated including linearity, selectivity, accuracy, precision, carry-over, and matrix effects. Additionally, stability under several conditions was tested to determine how to handle the standard solutions and serum samples. The seven cardiovascular drugs, simultaneously, were precisely and accurately analyzed in intra- and inter-day assays (RSD < 6 % and recovery between 96.3 and 102.8 %) using only two isotope-labeled internal standards (lidocaine-(diethyl-d10) and digoxin-21, 21, 22-d3). The presented method also showed good accuracy in analyzing the seven drugs in hyperlipidemia, hyperalbuminemia, and hyperglycemia serum, allowing it to be recommended as a common and routine analysis method for cardiovascular drugs in clinical practice.


Asunto(s)
Fármacos Cardiovasculares , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Monitoreo de Drogas/métodos , Solventes , Digoxina , Lidocaína , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados
11.
Anal Chem ; 94(28): 10127-10134, 2022 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-35802862

RESUMEN

To achieve the measurement reliability of amino acids used as diagnostic markers in clinical fields, establishing a reference measurement system is required, in which certified reference materials (CRMs) are an essential step in the hierarchy of measurement traceability. This study describes the development of dried blood spot (DBS) CRMs for amino acid analysis with complete measurement traceability to the International System of Units (SI). Six essential amino acids─proline, valine, isoleucine, leucine, phenylalanine, and tyrosine─were analyzed using isotope-dilution liquid chromatography-mass spectrometry (ID-MS). For minimizing measurement bias and uncertainty overestimation, whole spots with 50 µL of whole blood were adopted in the certification. The between-spot homogeneities by whole spot sampling were lower than 2.1%. The relative expanded uncertainties of the six amino acids in the developed DBS CRMs were lower than 5.7% at 95% confidence. The certified values are traceable to SI through both gravimetric preparation and the primary method in certification, ID-MS. Comparison among DBS testing laboratories revealed discrepancies between the whole spot and disc sampling methods. The actual sampling volume was accurately estimated by weighing, which revealed the possibility of underestimation in routine DBS testing. The candidate CRMs can support the standardization of DBS testing for amino acids through the qualification and validation of many kinds of measurement procedures to compensate the measurement bias caused by matrix-specific sampling error.


Asunto(s)
Aminoácidos , Pruebas con Sangre Seca , Aminoácidos/análisis , Certificación , Cromatografía Liquida/métodos , Estándares de Referencia , Reproducibilidad de los Resultados
12.
J Clin Lab Anal ; 36(7): e24521, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35622611

RESUMEN

BACKGROUND: The standardization of measurement aims to achieve comparability of results regardless of the analytical methods and the laboratory where analyses are carried out. In this paper, a comparison of results from several immunoassay-based insulin analysis kits is described, and the steps necessary to improve comparability are discussed. METHODS: Four manual enzyme-linked immunosorbent assay (ELISA) kits produced by Mercodia, Alpco, Epitope Diagnostics, and Abcam, and three automated chemiluminescent (CLIA) insulin assay kits (Siemens Centaur XP, Unicel Dxl800, Cobas e801) were compared by analyzing human serum samples and certified reference materials for human insulin. RESULTS: The seven evaluated assay kits showed substantial discrepancies in the results, with relative standard deviation ranges between 1.7% and 23.2%. We find that the traceability chains and the unit conversion factors are not yet harmonized, and current reference materials for insulin are not applicable for immunoassay-based method validation due to the use of different matrices. CONCLUSIONS: The findings suggest the need to fine tune insulin analysis methods, measurement traceability, and any conversion factor used in post-analysis steps in accordance with the necessity for standardization.


Asunto(s)
Pruebas Inmunológicas , Insulina , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Inmunoensayo/métodos , Estándares de Referencia
13.
Anal Bioanal Chem ; 413(21): 5517-5527, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34286356

RESUMEN

To achieve the measurement reliability of monosaccharides used as diagnostic markers in clinical fields, it is essential to establish certified reference materials (CRMs). The purpose of this study is to develop a serum CRM by adopting high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) as a new candidate reference measurement procedure for the measurement of glucose and galactose, common diagnostic markers of diabetes and galactosemia, respectively. Using various monosaccharides as internal standards, the accuracy of the HPAEC-PAD method was tested by measuring glucose CRM following treatment with three different deproteinization methods: ultrafiltration, protein precipitation by trichloroacetic acid (TCA), and protein precipitation by acetonitrile. Results showed that ultrafiltration and 5% TCA provided good accuracy with every tested monosaccharide as the internal standard. Accordingly, serum samples in this study were treated by ultrafiltration after adding 2-deoxy-D-glucose and arabinose, which were selected as internal standards for galactose and glucose, respectively. Both intra- and inter-day recovery tests showed good precision and accuracy within 2%. From the serum CRM batches prepared at two levels, 11 units were analyzed by exact-matched calibration methods, and the mass fractions of galactose and glucose were determined via HPAEC-PAD. The between-unit relative standard deviations were not more than 1.5%, showing homogeneity. The expanded uncertainties (%) of galactose and glucose for both levels were less than 3.6% and 2.3% at 95% confidence. The HPAEC-PAD method presented in this study can significantly improve the accuracy and precision of simultaneous monosaccharide analysis, allowing for the development of further serum CRMs for monosaccharides. Graphical abstract.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Monosacáridos/sangre , Glucemia/análisis , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Líquida de Alta Presión/normas , Cromatografía por Intercambio Iónico/normas , Galactosa/sangre , Humanos , Límite de Detección , Estándares de Referencia , Reproducibilidad de los Resultados
14.
Anal Bioanal Chem ; 411(28): 7341-7355, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31667564

RESUMEN

Over two decades, the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) has organized a number of comparisons for clinically relevant small molecule organic biomarkers. The aim of the OAWG community is to be part of the coordinated international movement towards accuracy and comparability of clinical measurements that will, in turn, minimize the wastage of repeat testing and unnecessary therapy to create a sustainable healthcare industry. International and regional directives/requirements on metrological traceability of calibrators and control materials are in place. Metrology institutes worldwide maintain infrastructure for the practical realization of metrological traceability and demonstrate the equivalence of their measurement capabilities through participation in key comparisons organized under the auspices of the CCQM. These institutes provide certified reference materials, as well as other dedicated value-assignment services benefiting the in-vitro diagnostic (IVD) industry, reference (calibration) laboratories and the clinical chemistry laboratories. The roles of these services in supporting national, regional, and international activities to ensure the metrological traceability of clinical chemistry measurements are described. Graphical abstract.


Asunto(s)
Biomarcadores/análisis , Compuestos Orgánicos/análisis , Bibliotecas de Moléculas Pequeñas/análisis , Calibración , Pruebas de Química Clínica , Humanos , Técnicas In Vitro , Estándares de Referencia , Reproducibilidad de los Resultados
15.
Artículo en Inglés | MEDLINE | ID: mdl-31476578

RESUMEN

A baseline dip caused by the reduction of dissolved oxygen in samples has been a source of trouble in the analysis of major monosaccharides (galactose, glucose, mannose, and fructose) in the high-performance anion-exchange chromatography with pulsed amperometric detection system. This study attempted three different methods to remove the baseline dip from the resulting chromatograms, and among the approaches, sodium sulfite was found to act as the best oxygen scavenger. Clean chromatograms were obtained by adding at least 3 mg/mL sodium sulfite to samples, which removed the baseline dip and improved the accuracy of sugar analysis. Although sodium sulfite does not influence analytical sensitivity, it can cause a reduction of sugar retention; however, retention time can be recovered by washing with 200 mM sodium hydroxide solution. Results demonstrated that sodium sulfite is an effective means either to remove the baseline dip for low concentration analysis under 1 mg/L, or to separate the target sugar from the baseline dip by retention time rearrangement.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Monosacáridos/análisis , Oxígeno/química , Sulfitos/química , Modelos Lineales , Monosacáridos/química , Reproducibilidad de los Resultados
16.
Anal Chem ; 91(6): 3936-3943, 2019 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-30773003

RESUMEN

Conventional DNA quantification methods require a DNA purification step that limits their reliability in estimating the original DNA amount, especially in complex matrix. To overcome this limitation, we developed a method to calibrate the variable DNA extraction efficiencies during the purification process, allowing for the accurate quantification of DNA in complex matrix. This method is based on isotope dilution-liquid chromatography-mass spectrometry using stable isotope labeled DNA (SILD) as an internal standard. Steps include spiking prepared SILD into samples, purification, enzymatic hydrolysis, and detection of DNA monomers via mass spectrometry, where the spiked SILD is expected to behave the same as the target DNA throughout the entire procedure. We show that the mean recoveries of four different DNA purification kits were dramatically improved by using the SILD internal standard, both for Escherichia coli and human genomic DNA. As standards for calibration, deoxyribonucleoside monophosphates and purified genomic DNA were tested, with genomic DNA from corresponding species found to calibrate the variable extraction efficiencies more effectively. With this successful calibration, our newly developed procedure enables International System of Units-traceable quantification of total DNA in complex matrix.


Asunto(s)
Cromatografía Liquida/métodos , ADN Bacteriano/análisis , ADN/sangre , Escherichia coli/metabolismo , Marcaje Isotópico/métodos , Espectrometría de Masas en Tándem/métodos , Humanos , Técnicas de Dilución del Indicador , Reproducibilidad de los Resultados
17.
Artículo en Inglés | MEDLINE | ID: mdl-29102246

RESUMEN

Astragali Radix, the root of Astragalus membranaceus Bunge, is one of the most frequently used crude drugs in Asian medicine. We developed a quantification method for 6 components (calycosin, formononetin, astragaloside I-IV) of Astragali Radix and Hwanggi-gyeji-omul-tang (HGOT) using reverse-phase high-performance liquid chromatography coupled with integrated pulsed amperometric detection (RP-HPLC-IPAD). The plants were extracted in 80% ethanol for 2h. All target components were detected with good sensitivity using sodium hydroxide (as a post-column eluent). The limit of detection (S/N=3) and limit of quantification (S/N=10) of the target components ranged from 0.10-1.00ng and from 0.30-3.00ng, respectively. The coefficients of linear regression ranged from 0.9993-1.0000, all interday and intraday precision values were <3.64%, and the average recovery ranged from 99.00-102.97% for Astragali Radix and 97.73-102.57% for HGOT. This method exhibited good selectivity, sensitivity, and reproducibility and can be used directly without any pretreatment steps. Our method will therefore be useful as a quality control measure for Astragali Radix.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Medicamentos Herbarios Chinos/química , Flavonoides/análisis , Saponinas/análisis , Triterpenos/análisis , Astragalus propinquus , Cromatografía de Fase Inversa , Flavonoides/química , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Saponinas/química , Triterpenos/química
18.
J Chromatogr A ; 1513: 183-193, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28743392

RESUMEN

Glycated hemoglobin (HbA1c), defined as hemoglobin (Hb) molecules having a stable adduct of glucose on the N-terminal of the ß-chains, has been endorsed as a diagnostic tool for diabetes mellitus and a prediction indicator for the development of diabetes complications. Here we describe an accurate procedure using two stages of isotope dilution-ultra performance liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) for the quantification of HbA1c that provides full traceability to International System of Units (SI). First, synthetic peptides representing specific markers of HbA1c (G-hexa) and hemoglobin A0 (Hexa) were certified by amino acid analysis via acid hydrolysis as reference materials (RMs) for the next step. For this peptide certification, three amino acids (proline, valine, and leucine) were determined by hydrolysis with 10M hydrochloric acid at 130°C for 48h followed by ID-LC-MS/MS. Then, HbA1c content in blood was quantified with the ratio of specific proteolytic peptides from HbA1c and HbA0 via enzyme digestion using ID-LC-MS/MS with the certified peptides as RMs and isotope-labeled peptides as internal standards. Results demonstrate complete traceability to SI-units throughout this procedure. Reliability was confirmed through comparative studies with commercially available RMs for HbA1c, and other routine HbA1c diagnostic methods as well. Following full method validation, we applied this procedure to the certification of candidate hemolysate-certified RMs for HbA1c content, as well as 52 real clinical samples. All of the results showed the suitability of this method to act as a primary reference measurement procedure for HbA1c in complex biological samples.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Hemoglobina Glucada/análisis , Técnicas de Dilución del Indicador , Sistema Internacional de Unidades , Espectrometría de Masas en Tándem/métodos , Adsorción , Aminoácidos/análisis , Calibración , Femenino , Humanos , Hidrólisis , Masculino , Péptidos/análisis , Estándares de Referencia , Reproducibilidad de los Resultados
19.
Biomed Chromatogr ; 30(2): 191-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26096721

RESUMEN

The purpose of this study is to evaluate the vitamin stabilities in dentifrices by analyzing various vitamins according to the level and storage temperature. The stabilities of water- and fat-soluble vitamins were investigated in buffer solution at different pH values (4, 7, 8, 10 and 11) for 14 days and in dentifrices at different pH (7 and 10) for 5 months at two temperature conditions (room and refrigeration temperature) by analyzing the remaining amounts using HPLC methods. In the buffer solution, the stability of vitamins B1 , B6 and C was increased as the pH values increased. Vitamins E and K showed poor stability at pH 4, and vitamin B3 showed poor stability at pH 11. In dentifrices, the storage temperature highly influenced vitamin stability, especially vitamins C and E, but the stabilities of vitamins B1 and C according to pH values did not correspond to the buffer solution tests. Vitamin B group was relatively stable in dentifrices, but vitamin C completely disappeared after 5 months. Vitamin K showed the least initial preservation rates. Vitamins were not detected in commercial dentifrices for adults and detected amounts were less than the advertised contents in dentifrices for children.


Asunto(s)
Dentífricos/química , Vitaminas/análisis , Vitaminas/química , Cromatografía Líquida de Alta Presión , Estabilidad de Medicamentos , Concentración de Iones de Hidrógeno , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Solubilidad , Temperatura
20.
Dent Mater J ; 34(3): 327-35, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25904171

RESUMEN

The aim of this study was to analyze the unreacted monomers of four commonly used composite resins, which were released after curing with different polymerization conditions. Four composite resins, consisting of two hybrid types and two flowable types from two manufacturers, were photopolymerized using different curing times and curing distances. After polymerization, samples were extracted for analysis at different time points up to 24 h. Released monomers were analyzed by reversed-phase liquid chromatography at UV 210 nm. Longer curing times and shorter curing distances resulted in higher polymerization rates and decreased release of TEGDMA and UDMA, but changes in curing time and distance had no significant effect on Bis-GMA. Release of BPA increased with increase in curing time or decrease in curing distance, in contrast to the results of TEGDMA and UDMA. Polymerization conditions need to be differently applied according to both monomer and resin types.


Asunto(s)
Compuestos de Bencidrilo/química , Resinas Compuestas/química , Fenoles/química , Polimerizacion , Cromatografía de Fase Inversa , Ensayo de Materiales , Metacrilatos/química , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA