1.
BMC Oral Health ; 24(1): 986, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39180005

RESUMEN

BACKGROUND: The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions. Therefore, this study aimed to examine how repeated up-and-down movements at the working length affect torque/force generation, surface defects, and canal shaping ability of JIZAI and TruNatomy instruments. METHODS: An original automated root canal instrumentation device was used to prepare canals and to record torque/force changes. The mesial roots of human mandibular molars with approximately 30˚ of canal curvature were selected through geometric matching using micro-computed tomography. The samples were divided into three groups according to the number of up-and-down movements at the working length (1, 3, and 6 times; n = 24 each) and subdivided according to the instruments: JIZAI (#13/0.04 taper, #25/0.04 taper, and #35/0.04 taper) or TruNatomy (#17/0.02 taper, #26/0.04 taper, and #36/0.03 tape) (n = 12 each). The design, surface defects, phase transformation temperatures, nickel-titanium ratios, torque, force, shaping ability, and surface deformation were evaluated. Data were analyzed with the Kruskal-Wallis and Dunn's tests (α = 0.05). RESULTS: The instruments had different designs and phase transformation temperatures. The 3 and 6 up-and-down movements resulted in a smaller upward force compared to 1 movement (p < 0.05). TruNatomy generated significantly less maximum torque, force, and surface wear than JIZAI (p < 0.05). However, TruNatomy exhibited a larger canal deviation (p < 0.05). No statistical differences in shaping ability were detected between different up-and-down movements. CONCLUSIONS: Under laboratory conditions with JIZAI and TruNatomy, a single up-and-down movement at the working length increased the screw-in force of subsequent instruments in severely curved canals in the single-length instrumentation technique. A single up-and-down movement generated more surface defects on the file when using JIZAI. TruNatomy resulted in less stress generation during instrumentation, while JIZAI better maintained the curvature of root canals.


Asunto(s)
Níquel , Preparación del Conducto Radicular , Propiedades de Superficie , Titanio , Torque , Preparación del Conducto Radicular/instrumentación , Humanos , Níquel/química , Microtomografía por Rayos X , Estrés Mecánico , Diseño de Equipo , Aleaciones Dentales/química , Técnicas In Vitro , Ensayo de Materiales , Diente Molar , Instrumentos Dentales
2.
J Dent Sci ; 19(2): 929-936, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38618130

RESUMEN

Background/purpose: Temperature-dependent phase compositional changes influence the mechanical properties of heat-treated nickel-titanium (NiTi) rotary instruments. This study evaluated the phase composition, bending properties, and cyclic fatigue resistance of HyFlex EDM NiTi rotary instruments against differently heat-treated and non-heat-treated NiTi instruments at body temperature (BT). Materials and methods: HyFlex EDM OneFile (EDM) instruments, heat-treated HyFlex CM (CM) and Twisted File (TF) instruments, and non-heat-treated K3 instruments (size #25/.08) were subjected to differential scanning calorimetry, and the martensitic, R-phase, and reverse transformation starting and finishing temperatures were determined. A cantilever bending test and a cyclic fatigue test were conducted at BT (37 °C ± 1.0 °C), and the bending load and number of cycles to failure (NCF) were recorded. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Results: TF and K3 had reverse transformation finishing temperatures lower than BT, while those for EDM and CM were higher than BT. The bending loads at a 0.5 mm deflection were in the order of EDM < TF < CM < K3 (P < 0.05), and those at a 2.0 mm deflection were EDM < CM and TF < K3 (P < 0.05). EDM had the highest NCF among the four instruments (P < 0.05). Conclusion: The EDM instrument had a reverse transformation finishing temperature higher than BT indicating its martensite/R-phase composition at BT. The EDM instrument had superior flexibility and greater resistance to cyclic fatigue than the CM, TF, and K3 instruments at BT.

3.
Dent Mater J ; 43(3): 329-337, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38583993

RESUMEN

The aim of this study was to evaluate how preset torque settings influence the torque, vertical force, and root canal-centering ability of ProGlider and ProTaper NEXT nickel-titanium rotary instruments in canals with different curvature locations. Based on micro-computed tomography, mesial roots of human mandibular molars (25°-40° curvature) were allocated to the apical curvature (apical 1-5 mm) or the middle curvature (apical 5-9 mm) groups, and mandibular incisors (curvature <5°) to the straight canal group. Each group was subjected to automated instrumentation and torque/force measurement with the preset torque of 1, 2.5, or 5 N•cm. Canal-centering ratios were determined with micro-computed tomography. Instrument fracture occurred only in the 2.5 and 5 N•cm groups in curved canals. The preset torque setting and curvature location did not influence canal shaping ability.


Asunto(s)
Níquel , Preparación del Conducto Radicular , Propiedades de Superficie , Titanio , Torque , Microtomografía por Rayos X , Humanos , Titanio/química , Níquel/química , Preparación del Conducto Radicular/instrumentación , Técnicas In Vitro , Cavidad Pulpar , Diente Molar , Instrumentos Dentales , Ensayo de Materiales , Diseño de Equipo , Aleaciones Dentales/química , Análisis del Estrés Dental
4.
J Dent Sci ; 18(4): 1598-1603, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37799866

RESUMEN

Background/purpose: The glide path instruments are the introductory instruments into the canals; thus, they should be durable enough to withstand torsional stress/screw-in force. This study aimed to investigate the torque and screw-in force of TruNatomy Glider (TN), ProGLIDER (PG), Hyflex EDM (EDM) and Dent Craft RE (RE) glide path instruments in single- and double-curved canals. Materials and methods: Each instrument brand was divided into two groups (n = 7 each) according to the canal configuration. Torque and screw-in force were recorded during automated instrumentation of simulated resin canals with XSmart IQ cordless motor after the canal patency was checked with a #10 K-file. The values were statistically analyzed using the Kolmogorov-Smirnov test followed by the Kruskal Wallis test and the Mann-Whitney U test with Bonferroni correction (α = 0.05). Results: TN produced significantly higher torque than RE in single-curved canals and PG in double-curved canals (P < 0.05). EDM yielded significantly higher screw-in force than TN and RE in single-curved canals (P < 0.05), but there was no significant difference in double-curved canals (P > 0.05). A significant effect of different canal configurations was only detected for screw-in force in EDM (P < 0.05). Conclusion: TN in single-curved canals and RE in double-curved canals yielded higher torque values, while EDM exhibited greater screw-in force in both canal configurations. No effect of different canal configurations was detected for torque, but a significant impact was detected for screw-in force in EDM.

5.
J Dent Sci ; 18(3): 1170-1176, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37404613

RESUMEN

Background/purpose: Using conventional approach to examine stationary torque of nickel-titanium rotary instruments contradicts the clinical condition, and its validity for motions involving clockwise and counterclockwise rotations is questionable. This study aimed to examine the effect of different kinematics on the torsional behavior using a JIZAI instrument (#25/.04) under stationary/dynamic test conditions using clinical torque limit settings. Materials and methods: In the stationary test, the 5-mm tip of JIZAI was fixed in a cylinder-shaped vise and rotated in continuous rotation (CR) with auto-torque-reverse, optimum-torque-reverse (OTR), or reciprocation (REC) until fracture (n = 10, each). In the dynamic test, straight and severe curved canals were instrumented with JIZAI using the single-length technique with CR, OTR, or REC (n = 10, each). The stationary torque at fracture, time to fracture (Tf), dynamic torque, and screw-in force were recorded using automated-shaping-device with torque/force measuring unit. One-way ANOVA or Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction were used for statistical analysis (⍺ = 0.05). Results: The kinematics did not influence the stationary or dynamic torques (P > 0.05); however, did influence the screw-in force in straight canals (P < 0.05). REC had significantly longer Tf, and severe curved canals yielded significantly greater torque and screw-in force in CR (P < 0.05). Conclusion: Under the present experimental conditions, parameters other than torque showed significant effects on different kinematics. The dynamic torque and screw-in force of OTR were similar to the other rotational modes and not influenced by the canal curvature.

6.
BMC Oral Health ; 22(1): 617, 2022 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-36529721

RESUMEN

BACKGROUND: To evaluate the effect of pecking motions with faster upward speed on the dynamic cyclic fatigue resistance of nickel-titanium rotary instruments with different metallurgy. METHODS: Forty each of ProTaper Universal F3 (PTU) and ProTaper Gold F3 (PTG) instruments (size #30/.09) were equally divided into four groups. The test was performed using an 18-mm-long stainless steel artificial canal with a 5-mm radius of curvature, a 45° canal curvature and a 2-mm canal diameter. A downward speed of 100 mm/min was employed, while the upward speed was set at 100, 150, 200 or 300 mm/min. Time to failure (Tf), number of cycles to failure (Nf) and number of pecking motions to failure (Np) were recorded. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests for Tf, Nf, and Np (α = 0.05). RESULTS: The 100/300 mm/min group showed significantly higher Np values than the 100/100 mm/min group (p < 0.05), whereas there were no significant differences in Tf and Nf among the tested speed groups (p < 0.05) in either PTU or PTG. PTG exhibited significantly higher Tf, Nf, and Np than PTU (p < 0.05). CONCLUSIONS: Under the tested conditions, the fastest upward speed group showed significantly higher cyclic fatigue resistance, as demonstrated by larger Np, than the same speed group. PTG had significantly higher cyclic fatigue resistance than PTU in all groups.


Asunto(s)
Níquel , Titanio , Humanos , Preparación del Conducto Radicular , Ensayo de Materiales , Falla de Equipo , Aleaciones Dentales , Instrumentos Dentales , Diseño de Equipo , Estrés Mecánico
7.
J Endod ; 47(1): 94-99, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33002538

RESUMEN

INTRODUCTION: This study aimed to analyze torque/force generation and transportation in double-curved canals instrumented with 3 types of glide path files using optimum glide path (OGP) motion in comparison with continuous rotation. METHODS: Sixty simulated double-curved canals were prepared with #10/0.05 or #15/0.03 HyFlex EDM Glidepath files (Coltene/Whaledent, Altstätten, Switzerland) or a #13/0.04 prototype MANI Glidepath file (Tochigi, Japan) using OGP motion or continuous rotation (n = 10 each). Canals were sequentially prepared to 20 mm and 22 mm (full working length) using automated root canal instrumentation and a torque/force analyzing device. Transportation was calculated at 1-9 mm from the apex. Data were compared using 2-way analysis of variance followed by a post hoc simple main effect test with Bonferroni correction and a Kruskal-Wallis test (α = 5%). RESULTS: All #10/0.05 instruments fractured. In the 22-mm preparation, the OGP motion resulted in lower clockwise torque and screw-in force than did continuous rotation (P < .05). In the 20-mm preparation, #15/0.03 instruments recorded a lower screw-in force for OGP motion than for continuous rotation (P < .05). Comparing the 2 preparation phases, OGP motion generated no significant differences; however, continuous rotation developed higher clockwise torque and screw-in force in the 22-mm preparation than in the 20-mm preparation (P < .05). There was no significant difference among the tested groups for transportation values. CONCLUSIONS: Compared with continuous rotation, OGP motion generated less screw-in force, lower clockwise torque, and similar transportation. The #15/0.03 HyFlex EDM instrument and the #13/0.04 prototype MANI instrument performed similarly well.


Asunto(s)
Tornillos Óseos , Preparación del Conducto Radicular , Instrumentos Dentales , Cavidad Pulpar , Diseño de Equipo , Rotación , Titanio , Torque