Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Materials (Basel) ; 16(18)2023 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-37763605

RESUMEN

The objective of this study was to evaluate different delaying times after bleaching and the use of different sodium ascorbate (SA) concentrations (10% and 35%) in the bond strength of adhesive cementation to enamel. This study used 54 sound bovine incisors, which were randomly assigned to the following groups: G1 (unbleached/control+ adhesive cementation (AC)); G2 (bleached + AC after 7 days); G3 (bleached + 10% SA + AC after 24 h); G4 (bleached + 10% SA + AC after 7 days); G5 (bleached + 35% SA + AC after 24 h); and G6 (bleached + 35% SA + AC after 7 days). After bleaching, G3, G4, G5, and G6 received an application of SA before the cylinders build up with RelyX Veneer cement. The samples were subjected to microshear test, and the results were analyzed by two-way ANOVA with Tukey's post hoc test. Group one presented the highest mean bond strength (19.1 MPa) and G3 the lowest (16.96 MPa). There was no statistical difference between the groups tested (p ˃ 0.05). The fracture pattern observed was predominantly mixed. The adhesive cementation may be performed 24 h after bleaching when SA (10% or 35%) is used or after 7 days, without compromising bond strength.

2.
Clin Cosmet Investig Dent ; 15: 63-70, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37091917

RESUMEN

Aim: The study evaluated the influence of tucupi on enamel surface roughness, microhardness, ultramorphology, and mass variation. Materials and Methods: Ninety healthy bovine incisors were divided into three experimental groups, according to the acidic challenge adopted, being: G1- tucupi, G2- cola-based soft drink, G3-distilled water. The enamel properties (surface roughness, microhardness, ultramorphology and mass variation) of all specimens were evaluated at times T0 (before any intervention), T10 (10 days after the proposed treatments), T20 (20 days after the proposed treatments) and T30 (30 days after the proposed treatments). After confirming the normality of the data (Shapiro-Wilk test), a two-way ANOVA (α = 5%) was performed, followed by Sidak post-test, with results described as mean and standard deviation. Results: The roughness means increased for all tested groups, with no statistical difference only in G3 for all evaluated times. Microhardness of all groups showed a significant decrease over the time, with the lowest average observed in G1 in T30. Considering enamel mass variation, the lowest average was in G2 at time T3, with no statistical difference only in G3 (distilled water) over the time. Regarding ultramorphology (scanning electron microscopy - SEM), only groups G1 and G2, that were exposed to acidic challenges, showed disorganization of the enamel surface layer. Conclusion: It was possible to conclude that tucupi has low pH and high titratable total acidity, being able to gradually decrease enamel microhardness, increasing surface roughness and causing loss of dental enamel.

3.
Materials (Basel) ; 15(21)2022 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-36363088

RESUMEN

This study aimed to evaluate the effects of 22% carbamide peroxide combined with an erosive challenge and simulated brushing on enamel. Bovine incisor teeth were divided into G1, tooth bleaching; G2, tooth bleaching + erosive challenge; and G3, tooth bleaching + erosive challenge + simulated brushing, and evaluated at T0, before any intervention; T1, 14 days after the proposed treatments; and T2, 28 days after the proposed treatments. Tooth bleaching was performed daily for 1 h for 28 days. The microhardness, surface roughness, mass variation, and ultrastructure were analyzed at T0, T1, and T2. Two-way analysis of variance for repeated measures was performed and Tukey's post hoc test (α = 5%) was used. The surface roughness increased in groups G2 and G3 as a function of time, whereas microhardness and mass measurements demonstrated a significant reduction for groups associated with challenges. Ultrastructural evaluation indicated a loss of the aprismatic layer and exposure of the enamel prisms in all groups after 14 days of bleaching, with more pronounced results in G2 and G3 after 28 days. In conclusion, abrasive and erosive challenges potentiated the deleterious effects of tooth whitening on microhardness, ultramorphology, and mass, without affecting the roughness of dental enamel.

4.
Braz Oral Res ; 35: e113, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34816901

RESUMEN

The ultrastructural and mechanical properties of enamel surface were evaluated after prolonged bleaching treatments with 10% carbamide peroxide in the presence or absence of orange juice (erosive challenge) and toothbrushing (abrasive challenge). In total, 145 incisor bovine teeth were used in this study. Twenty-five samples were prepared for the ultrastructural evaluations, and 120 samples were prepared for microhardness and roughness tests. These 120 samples were divided into eight experimental groups (n = 15): G1- artificial saliva; G2- abrasion; G3- erosion; G4- dental bleaching; G5- erosion + abrasion; G6- bleaching + abrasion; G7- bleaching + erosion; and G8- bleaching + erosion + abrasion. All groups were tested at T0 (before treatment), T1 (14 days), T2 (21 days), and T3 (28 days). Two-way analysis of variance for repeated measures and the post hoc Sidak tests (p ≤ 0.05) were used. The roughness evaluation demonstrated an increase in damage for all experimental groups with an increase in the time period. For microhardness, the groups exposed to artificial saliva (AS) and abrasive challenge did not show any differences at any time points, while the other groups showed a decrease in microhardness from T0 to T3. Ultrastructural evaluation showed different surface alterations in response to the treatments. Despite prolonged bleaching periods, the procedure caused lesser enamel surface alterations than exposure to orange juice alone or in combination with brushing.


Asunto(s)
Blanqueamiento de Dientes , Animales , Peróxido de Carbamida , Bovinos , Esmalte Dental , Hábitos , Blanqueamiento de Dientes/efectos adversos , Cepillado Dental
5.
J Evid Based Dent Pract ; 21(2): 101542, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34391554

RESUMEN

OBJECTIVE: Reporting of randomized controlled trials (RCTs) in dentistry remains suboptimal. Considering the positive impact of the Consolidated Standards of Reporting Trials (CONSORT) guidelines on the quality of evidence in RCTs, the main objective of this systematic review was to determine whether RCTs on dental caries prevention conform to these guidelines. The secondary objective was to assess the association between CONSORT adherence and the year and impact factor of the journal in which the study was published. METHODS: A systematic search was conducted in different databases using appropriate terms to retrieve RCTs that assessed the caries-preventive effect of at least 2 of the following materials-fluoride varnish, resin-based fissure sealants, and ionomer-based fissure sealants-on the occlusal surfaces of permanent molars. Since the first CONSORT statement was published in 1996, a time frame from 1997 to 2020 was established for the identification of studies. Selected articles were assessed according to their adherence to the CONSORT statement, risk of bias (Cochrane risk of bias tool, RoB 2.0), and journal impact factor based on the InCites Journal Citation Reports. The year of publication and other relevant data were also recorded. SPSS (SPSS Statistics 25.0, IBM©) was used to perform the linear correlation analyses to determine the relationship between the article CONSORT score (previously determined) and the year of publication and journal impact factor. A significance level of 5% was established for all analyses. RESULTS: Of 3196 references retrieved, 30 articles were selected and evaluated. Using RoB 2.0, 8 studies were classified as having a high risk of bias, 16 as having some concerns about the risk of bias assessment, and 6 as having a low risk of bias. Concerning CONSORT adherence, 77% of the studies adequately reported the intervention domain, since the methodology for the application of fluoride varnish or sealant materials was thoroughly described. However, the participants' setting and location, random sequence generation, randomization, and the flowchart description of the losses/exclusions domains were poorly reported. Meanwhile, the allocation concealment process was not reported in 83% of the articles. Correlation analyses indicated a positive relationship between CONSORT adherence and the year of publication, as well as the journal impact factor. CONCLUSION: When assessing clinical trials on the prevention of occlusal caries, most RCTs examined followed the CONSORT statement. However, some methodological domains remain poorly reported, demonstrating the need to improve CONSORT compliance in these RCTs.


Asunto(s)
Caries Dental , Selladores de Fosas y Fisuras , Caries Dental/prevención & control , Fluoruros , Humanos , Diente Molar , Ensayos Clínicos Controlados Aleatorios como Asunto
6.
Int. j. odontostomatol. (Print) ; 15(2): 415-420, jun. 2021. tab
Artículo en Inglés | LILACS | ID: biblio-1385747

RESUMEN

The objective of this study was to determine the enamel mass variation after a prolonged bleaching treatment using a calcium-containing 4% hydrogen peroxide gel Twenty sound bovine incisors were randomly assigned to two groups (n=10) stored in G1) distilled water and G2) artificial saliva. An electronic analytic scale (.000 grams measurements) was used to determine the enamel mass variation before and after the bleaching procedures at the following evaluation times: T0) before the bleaching procedures; T1) 14 days of treatment, as instructed by the manufacturer; T2) 21 days of treatment, 50 % beyond what is instructed by the manufacturer; and T3) 28 days of treatment, 100 % beyond what is instructed by the manufacturer. The highest mean was observed at T2/G2 (0.3259 g) and the lowest at T2/G1 (0.3265 g). The specimens stored in distilled water (G1) showed 6 % mass reduction when T0 (0.3277 g) was compared to T3 (0.3277 g). On the other hand, the specimens stored in artificial saliva exhibited a significant mass increase of 19 % when T0 (0.3521 g) was compared to T3 (0.3528 g). Prolonged bleaching therapy using 4 % hydrogen peroxide with calcium resulted in a massive reduction when water was used as a storage medium. When the specimens were stored in artificial saliva, an increase in mass was observed, probably due to the mineralizing properties of the artificial saliva.


El objetivo de este estudio fue determinar la variación de la masa del esmalte después de un tratamiento de blanqueamiento prolongado utilizando calcio conteniendo un gel de peróxido de hidrógeno al 4 %. Veinte incisivos bovinos intactos fueron asignados aleatoriamente a dos grupos (n-10) almacenados en G1 - agua destilada y G2- saliva artificial. Se utilizó una escala analítica electrónica (.000 gramos) para determinar la variación de la masa de esmalte antes y después de los procedimientos de blanqueamiento en los siguientes tiempos de evaluación: T0) antes de los procedimientos blanqueadores; T1) 14 días de tratamiento, según las instrucciones del fabricante; T2) 21 días de tratamiento, 50 % más allá del tiempo indicado por el fabricante; y T3) 28 días de tratamiento, 100 % más allá del tiempo indicado por el fabricante. La media más alta se observó en T2/G2 (0,3259 g) y la más baja en T2/G1 (0,3265 g). Los especímenes almacenados en agua destilada (G1) mostraron una reducción de masa del 6 % cuando se comparó T0 (0,3277 g) con T3 (0,3277 g). Por otro lado, los dientes almacenados en saliva artificial mostraron un aumento significativo de masa del 19 % cuando se comparó T0 (0,3521 g) con T3 (0,3528 g). La terapia de blanqueamiemto prolongado con calcio conteniendo un gel de peróxido de hidrógeno al 4 % condujo a una reducción masiva cuando se utilizó agua como medio de almacenamiento, mientras que los dientes almacenados en saliva artificial mostraron un aumento en la masa, probablemente debido a las propiedades remineralizadoras de la saliva artificial.


Asunto(s)
Animales , Esmalte Dental/metabolismo , Blanqueadores , Peróxidos/uso terapéutico , Saliva Artificial , Ensayo de Materiales , Agua Destilada , Análisis de Varianza
7.
Braz. oral res. (Online) ; 35: e113, 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1350359

RESUMEN

Abstract The ultrastructural and mechanical properties of enamel surface were evaluated after prolonged bleaching treatments with 10% carbamide peroxide in the presence or absence of orange juice (erosive challenge) and toothbrushing (abrasive challenge). In total, 145 incisor bovine teeth were used in this study. Twenty-five samples were prepared for the ultrastructural evaluations, and 120 samples were prepared for microhardness and roughness tests. These 120 samples were divided into eight experimental groups (n = 15): G1- artificial saliva; G2- abrasion; G3- erosion; G4- dental bleaching; G5- erosion + abrasion; G6- bleaching + abrasion; G7- bleaching + erosion; and G8- bleaching + erosion + abrasion. All groups were tested at T0 (before treatment), T1 (14 days), T2 (21 days), and T3 (28 days). Two-way analysis of variance for repeated measures and the post hoc Sidak tests (p ≤ 0.05) were used. The roughness evaluation demonstrated an increase in damage for all experimental groups with an increase in the time period. For microhardness, the groups exposed to artificial saliva (AS) and abrasive challenge did not show any differences at any time points, while the other groups showed a decrease in microhardness from T0 to T3. Ultrastructural evaluation showed different surface alterations in response to the treatments. Despite prolonged bleaching periods, the procedure caused lesser enamel surface alterations than exposure to orange juice alone or in combination with brushing.

8.
J. health sci. (Londrina) ; 21(4): https://seer.pgsskroton.com/index.php/JHealthSci/article/view/6496, 20/12/2019.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1051636

RESUMEN

This study evaluated the effect of different time intervals between tooth bleaching sessions on the variation of tooth enamel mass, using a 35% hydrogen peroxide (HP35) gel. Twenty bovine incisor teeth were collected and cross-sectioned twice, leaving only the middle coronal portion. The dentin layer was removed, leaving only the buccal dental enamel. The samples were randomly divided into 2 groups (n = 10): G1 (with a 7-day time interval between each bleaching session), and G2 (with a 2-day time interval between each bleaching session). Three bleaching sessions were performed for each group. Each specimen's mass was measured using an electronic analytical scale, first at the beginning of the experiments (T0), and then immediately after each bleaching intervention (T1, T2 and T3, respectively). All samples were stored in artificial saliva and kept in a biological chamber during the time of the study. The data analysis was performed using ANOVA for the related samples (p = 0.05). The results showed a reduction in the enamel mass values in G2 after the 3rd session when comparing to enamel mass values presented at the beginning of the study. On the other hand, G1 presented an increase in the mass values at the end of the third session, and these intragroup differences were statistically significant (p <0.001). It was concluded that bleaching treatment with 7-day intervals between sessions leads to no tooth enamel mass loss, whereas the reduced 2­day time interval between sessions caused a significant tooth enamel mass loss. (AU)


Este estudo avaliou a influência de diferentes intervalos de tempo entre as sessões de clareamento com peróxido de hidrogênio a 35% (PH35) sobre a variação de massa do esmalte dental. Foram utilizados 20 dentes incisivos bovinos hígidos, seccionados em duas porções transversais, com a camada de dentina vestibular toda removida, restando apenas o esmalte dental vestibular. As amostras foram distribuídas em 2 grupos (n=10): G1 - intervalo de tempo de 7 dias entre as sessões de clareamento, e G2 - Intervalo de 2 dias entre as sessões de clareamento. Foram realizadas 3 aplicações de gel clareador em cada grupo. A pesagem dos espécimes foi realizada antes do início do tratamento clareador e ao final de cada intervenção clareadora, em uma balança analítica eletrônica. Os espécimes foram armazenados em saliva artificial, e mantidos em estufa biológica. Os dados foram submetidos à ANOVA para amostras relacionadas (p=0.05). O G2 apresentou uma redução nos valores de massa do esmalte quando comparados os tempos antes do clareamento (T0 - 0.1650g) e após a 3° sessão (T3 - 0.1643g). Entretanto, o G1 apresentou um aumento nos valores de massa ao término da terceira sessão (T0 - 0.1615g e T3 - 0.1624g), sendo essas diferenças intragrupos estatisticamente significantes (p<0.001). Foi possível concluir que no clareamento com intervalo de 7 dias entre as sessões não houve perda de massa do esmalte dental, ao passo que quando reduzido o intervalo entre as sessões para 2 dias, uma perda significativa de massa foi observada. (AU)

9.
Clin Cosmet Investig Dent ; 11: 259-265, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31692502

RESUMEN

AIM: This study evaluated the effect of sodium ascorbate (SA) on the proteolytic activity of matrix metalloproteinases (MMPs) and investigated the related effects on the bond strength of bleached dentin. MATERIALS AND METHODS: Eighty freshly extracted human third molars were randomly divided according to treatment (bleaching or SA application), type of analysis (microshear or measuring MMP activity), and post-bleaching time to assess bond strength (24 hrs or 30 days). Data from both analyses were subjected to one-way analysis of variance to detect differences among groups, followed by Tukey's multiple comparison test (p≤0.05). RESULTS: Dental bleaching significantly reduced bond strength values when the adhesive strategy was performed after 24 hrs (despite the SA treatment) or 30 days after the bleaching procedure. However, after 30 days, the bond strength values of the groups who received bleaching or SA application were similar to those of the unbleached group. Dental bleaching caused the activation of MMPs, and SA did not influence this activity. CONCLUSION: It was concluded that SA does not affect the activity of MMPs or the bond strength in bleached dentin immediately after the bleaching treatment.

10.
Int. j. odontostomatol. (Print) ; 13(3): 305-309, set. 2019. tab
Artículo en Inglés | LILACS | ID: biblio-1012427

RESUMEN

ABSTRACT: The objective evaluate was the influence of prolonged tooth bleaching with 10 % carbamide peroxide (10CP) on tooth enamel mass variation. Ten healthy bovine incisor teeth were divided (n = 5) into G1 - storage in distilled water and G2 - storage in artificial saliva. The samples were weighed in an electronic analytical balance at the following times: T0 - before application of the bleaching gel, T1 - after 14 days of bleaching (the time recommended by the manufacturer), T2 - after 21 days of bleaching (50 % increase in the time recommended by the manufacturer), and T3 - after 28 days of bleaching (100 % increase in the time recommended by the manufacturer). The data were subjected to ANOVA for related samples (p = 0.05). The highest mean was observed in G2 (0.5982 g) and the lowest mean was observed in G1 (0.3074 g) at T2 and T3, respectively. Significant differences were observed between the groups at all times. Overall, 10CP caused variation in the enamel mass after a 100 % increase in the use time recommended by the manufacturer, with a decrease in mass when distilled water was used as the storage medium and an increase when artificial saliva was used.


RESUMEN: El objetivo fue investigar la influencia del blanqueamiento dental prolongado con peróxido de carbamida al 10 % (10CP) sobre la variación de masa del esmalte dental. Las muestras se dividieron en dos grupos: G1, diez dientes sanos de los incisivos bovinos (n = 5) en agua destilada, y G2, almacenamiento en saliva artificial. Las muestras se midieron en una escala analítica electrónica de precisión en los siguientes tiempos: T0-antes de la aplicación del gel blanqueador, T1-después de 14 días de blanqueo (el tiempo recomendado por el fabricante), T2-después de 21 días de blanqueo (aumento de 50 % en el tiempo recomendado por el fabricante), y T3-después de 28 días de blanqueo (aumento de 100 % en el tiempo recomendado por el fabricante). Los datos se presentaron al ANOVA para las muestras relacionadas (P = 0,5). La media más alta se observó en G2 (0,5982 g) y la media más baja se observó en G1 (0,3074 g) en T2 y T3, respectivamente. Se observaron diferencias significativas entre los grupos en todo momento. En general, la 10 CP causó variación en la masa del esmalte después de un aumento de 100 % en el tiempo de uso recomendado por el fabricante, con una disminución en la masa cuando el agua destilada se utilizó como medio de almacenamiento y aumentó cuando se usó saliva artificial.


Asunto(s)
Animales , Bovinos , Blanqueamiento de Dientes , Esmalte Dental/química , Solubilidad del Esmalte Dental/efectos de los fármacos , Blanqueadores Dentales/farmacología , Peróxidos , Brasil , Comités de Ética , Ganado , Peróxido de Carbamida
11.
Clin Cosmet Investig Dent ; 11: 81-87, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31040720

RESUMEN

AIM: The aim of this study was to compare the bonding strength of dental materials in buffalo (Bubalus bubalis var. kerebau), bovine, and human enamel and the susceptibility of these substrates in acid etching. MATERIALS AND METHODS: A total of 20 human third molars, 20 bovine incisors, and 20 buffalo incisors were used in a mechanical assay of microshear. The substrates were demineralized via conditioning with 37% phosphoric acid, and the ultra-morphological pattern of each substrate was analyzed by scanning electron microscopy. RESULTS: The results showed that there was no significant difference in adhesive bonding strength values between buffalo and human enamel (P≥0.05), with a fracture pattern of mixed type for all experimental groups. CONCLUSION: The results indicate that buffalo enamel is similar to human dental substrate in tests of adhesive bonding strength and also show a similar behavior in the acid conditioning of the enamel.

12.
PLoS One ; 14(4): e0214948, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30951549

RESUMEN

This work aimed to evaluate the roughness, microhardness, ultrastructure, chemical composition and crystalline structure in submitted teeth to a prolonged home bleaching regimen with 10% carbamide peroxide (10% PC) for different periods. The specimens were divided into the following groups: G1: negative control (application of water-soluble gel); G2: tooth whitening group (positive control), under application time recommended by the manufacturer (4h/14 days); G3: prolonged whitening 50%, under prolonged time recommended by the manufacturer in 50% (4h/21 days); G4: excessive whitening 100%, under exceeded manufacturer recommended time by 100% (4h/ 28 days). The results were evaluated descriptively and analytically. There were no changes in the roughness in any of the evaluated groups. However, the microhardness decreased in the G4 group. Scanning electron microscopy showed changes in the enamel surface of groups G2, G3 and G4. Dispersive X-ray spectroscopy identified changes in the concentration of chemical elements O, Mg, P, K in all groups. Thus, this study showed that prolonged home bleaching could cause changes in the ultrastructure, chemical composition and microhardness of the enamel.


Asunto(s)
Peróxido de Carbamida/farmacología , Esmalte Dental , Dureza/efectos de los fármacos , Blanqueamiento de Dientes , Animales , Bovinos , Esmalte Dental/metabolismo , Esmalte Dental/ultraestructura , Microscopía Electrónica de Rastreo , Propiedades de Superficie/efectos de los fármacos
13.
Open Dent J ; 12: 555-559, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30197694

RESUMEN

BACKGROUND: Dental bleaching has been increasingly sought out to improve dental aesthetics, but it may cause changes in dental enamel. OBJECTIVE: To assess the influence of different time intervals on bleaching gel applications with regard to the Microhardness (MH) and Surface Roughness (SR) on dental enamel. MATERIAL AND METHODS: Forty bovine incisors were randomly divided into two groups (G1 and G2) and both were bleached with 35% Hydrogen Peroxide (HP35) (n=20; G1: seven-day interval and G2: two-day interval). The MH and SR tests were performed before bleaching (T0) and after the first (T1), second (T2), and third (T3) bleaching gel applications. The specimens were stored in artificial saliva between each application (37°C). The data were analyzed using the student's t-test (p ≤ 0.05) for dependent samples. RESULTS: The reduced time interval (two days) led to a significant reduction in MH, while MH was not affected during the seven-day interval. The SR results increased regardless of the bleaching gel application time interval. CONCLUSION: The decreased time interval of two days between bleaching gel applications caused changes in MH but did not influence the SR of dental enamel.

14.
Iran Endod J ; 13(3): 367-372, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30083208

RESUMEN

INTRODUCTION: The aim of this in vitro study was to evaluate the effects of sodium hypochlorite (NaOCl), ethylenediaminetetraacetic acid (EDTA), chlorhexidine (CHX) and hydroxyethylidene bisphosphonate (HEBP), also known as etidronate, on susceptibility to root fracture resistance (RFR) in human teeth subjected to endodontic preparation. METHODS AND MATERIALS: Seventy extracted single-rooted human teeth were selected, endodontically prepared using the ProTaper Next rotary system (PTN, Dentsply, Maillefer, Ballaigues, Switzerland) and then randomly divided according to the following irrigation regimes (n=10): G1, saline solution (0.9% NaCl); G2, 2.5% NaOCl + 17% EDTA; G3, 2% CHX gel + 17% EDTA; and G4, a mixture of 5% NaOCl + 18% HEBP. After this step, all samples received a final irrigation with distilled water. The samples were subjected to axial forces by mechanical compression testing in a universal testing machine (Dynamometers KRATOS, LTDA, SP, Brazil). Data analyses included the Shapiro-Wilk normality test, analysis of variance (one-way ANOVA) and a subsequent multiple comparison test (Tukey's test). RESULTS: The results indicated that G1 (0.9% NaCl) presented greater resistance to root fracture. No significant differences were observed in G2 (2.5% NaOCl + 17% EDTA) and G3 (2% CHX gel + 17% EDTA). A significant difference was identified in G4 (mixture of 5% NaOCl + 18% HEBP) (P<0.05). CONCLUSION: A mixture of 5% NaOCl + 18% HEBP resulted in a lower fracture resistance when used to irrigate canals during endodontic instrumentation.

15.
Braz. dent. j ; Braz. dent. j;28(3): 346-353, May-June 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-888655

RESUMEN

Abstract The aim of this study was to evaluate the influence of an extended use of desensitizing toothpastes (DTs) on dentin bonding, microhardness and roughness. One hundred and twenty bovine incisor teeth were randomly divided into four groups: G1, distilled water (WATER); G2, Colgate Total 12 (CT12); G3, Colgate Sensitive Pro-Relief (CSPR); and G4, Sensodyne Repair ?αμπ; Protect (SRP). Dentin surfaces were etched with 17% EDTA and 2 years of simulated tooth brushing (20,000 cycles) was performed on their surfaces. Knoop microhardness, surface roughness and scanning electron microscopy (SEM) were performed before and after the simulated tooth brushing. For microshear bonding test, a 2-step self-etching adhesive system (Clearfil SE Bond) was used and 0.8 mm diameter composite resin (Filtek Z350 XT) cylinders were built. Microshear test was performed with an orthodontic wire and with a crosshead speed of 0.5 mm/min. The data were analyzed for: 1) bond strength (one-way ANOVA), 2) microhardness intra-group (Student's test) and inter-group (one-way ANOVA/Tukey's test) comparisons, 3) roughness intra-group (Student's test/Wilcoxon's test) and inter-group (Kruskal-Wallis/Student-Newman-Keuls test) comparisons. The extended use of both dentifrices (conventional and for sensitive teeth) did not affect the bond strength and produced a significant increase in microhardness and roughness of the dentin, except for the microhardness of the SRP group. The simulated tooth brushing technique with water produced an increase in roughness, without reducing significantly the dentin microhardness.


Resumo O objetivo deste estudo foi avaliar a influência do uso prolongado de dentifrícios dessensibilizantes (DTs) na adesão, microdureza e rugosidade da dentina. Cento e vinte dentes incisivos bovinos foram divididos aleatoriamente em quatro grupos: G1, água destilada (WATER); G2, Colgate Total 12 (CT12); G3, Colgate Sensitive Pro-alívio (CSPR); e G4, Sensodyne Repair ?αμπ; Protect (SRP). As superfícies dentinárias foram condicionadas com EDTA a 17% e foram realizados 2 anos de escovação dental simulada (20.000 ciclos) em suas superfícies. A microdureza Knoop, rugosidade de superfície e microscopia eletrônica de varredura (MEV) foram realizadas antes e após escovação dental simulada. Para o teste de adesão por microcisalhamento, foi aplicado um sistema adesivo auto condicionante de 2 passos (Clearfil SE Bond) e foram construídos cilindros de resina composta (Filtek Z350 XT) de 0,8 mm de diâmetro. O teste de microcisalhamento foi realizado com um fio ortodôntico e com velocidade de 0,5mm/min. Os dados foram analisados para: 1) resistência de união (ANOVA 1 fator), 2) comparações de microdureza intra grupo (teste t de Student) e inter grupo (ANOVA 1 fator / teste de Tukey), 3) comparações de rugosidade intra grupo (teste t de Student / teste de Wilcoxon) e inter grupo (Kruskal Wallis / teste de Student-Newman-Keuls). O uso prolongado de ambos dentifrícios (convencional e para dentes sensíveis) não interferiu na resistência de união e produziu um aumento significativo na microdureza e rugosidade da dentina, exceto para a microdureza do grupo SRP. A técnica de escovação dental simulada com água promoveu aumento na rugosidade, sem reduzir significativamente a microdureza da dentina.


Asunto(s)
Animales , Bovinos , Recubrimiento Dental Adhesivo , Dentífricos/administración & dosificación , Desensibilizantes Dentinarios/administración & dosificación , Dentina/ultraestructura , Pastas de Dientes/administración & dosificación , Pruebas de Dureza , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cepillado Dental
16.
Braz Dent J ; 28(3): 346-353, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29297556

RESUMEN

The aim of this study was to evaluate the influence of an extended use of desensitizing toothpastes (DTs) on dentin bonding, microhardness and roughness. One hundred and twenty bovine incisor teeth were randomly divided into four groups: G1, distilled water (WATER); G2, Colgate Total 12 (CT12); G3, Colgate Sensitive Pro-Relief (CSPR); and G4, Sensodyne Repair ?αµπ; Protect (SRP). Dentin surfaces were etched with 17% EDTA and 2 years of simulated tooth brushing (20,000 cycles) was performed on their surfaces. Knoop microhardness, surface roughness and scanning electron microscopy (SEM) were performed before and after the simulated tooth brushing. For microshear bonding test, a 2-step self-etching adhesive system (Clearfil SE Bond) was used and 0.8 mm diameter composite resin (Filtek Z350 XT) cylinders were built. Microshear test was performed with an orthodontic wire and with a crosshead speed of 0.5 mm/min. The data were analyzed for: 1) bond strength (one-way ANOVA), 2) microhardness intra-group (Student's test) and inter-group (one-way ANOVA/Tukey's test) comparisons, 3) roughness intra-group (Student's test/Wilcoxon's test) and inter-group (Kruskal-Wallis/Student-Newman-Keuls test) comparisons. The extended use of both dentifrices (conventional and for sensitive teeth) did not affect the bond strength and produced a significant increase in microhardness and roughness of the dentin, except for the microhardness of the SRP group. The simulated tooth brushing technique with water produced an increase in roughness, without reducing significantly the dentin microhardness.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentífricos/administración & dosificación , Desensibilizantes Dentinarios/administración & dosificación , Dentina/ultraestructura , Pastas de Dientes/administración & dosificación , Animales , Bovinos , Pruebas de Dureza , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cepillado Dental
17.
J Adhes Dent ; 18(5): 375-386, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27695714

RESUMEN

PURPOSE: To perform a systematic review of the clinical performance of a low polymerization shrinkage, siloranebased composite (SBC) compared with a methacrylate-based composite (MBC) in posterior restorations. MATERIALS AND METHODS: Electronic databases were searched: PubMed, Scopus, Bireme, Science Direct, Web of Science, ClinicalTrials.gov and OpenGrey. The search strategy included MeSH terms, synonyms and keywords with no language or date restrictions. Reference lists of eligible studies were cross checked in an attempt to identify additional studies. Based on the PICOS strategy, only randomized clinical trials (RCTs) were included. The risk of bias in the included studies was assessed and classified through the Cochrane Collaboration common scheme for bias. Two meta-analyses were performed using RevMan software, one with all 11 studies and another that included only studies with over 24 months of follow-up, for the main parameters analyzed. RESULTS: A total of 544 studies were identified. After removing duplicates and examinating titles and abstracts, 17 texts were selected and read in full. Six of them were excluded, so the final sample of this systematic review included 11 studies. Six of the 11 studies were classified as having a "low risk of bias" and five were "unclear". The heterogeneity (I²) in all parameters was not significant. The exclusion of studies with less than 24 months of follow- up did not change the final result of the meta-analysis: both SBC and MBC have satisfactory and statistically similar clinical performances. CONCLUSION: Low polymerization shrinkage is not the principal factor that determines the superiority of a resin.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Resinas de Silorano , Humanos , Metacrilatos , Ensayos Clínicos Controlados Aleatorios como Asunto
18.
Int. j. odontostomatol. (Print) ; 10(2): 267-276, ago. 2016. ilus
Artículo en Inglés | LILACS | ID: lil-794487

RESUMEN

The objective of this randomized clinical trial was to evaluate the clinical performance up to 18 months of restorations placed using ethanol-wet bonding technique (EWBT) compared with the three-step etch-and-rinse (TSER) and one-step self-etching (OSSE) approaches. Ninety-three non-carious cervical lesions (31 for each group) were restored by one experienced operator in 17 patients under relatively dry conditions using gingival retraction cord, cotton rolls and saliva ejector. Each adhesive system was randomly allocated to one of randomized cervical lesions until the three groups were present in the same subject in equal amounts. The restorations were evaluated at baseline, 6, 12 and 18 months by two blinded and calibrated examiners using the modified US Public Health Service guidelines (USPHS) for the following outcomes: retention (kappa= 1.00), staining and marginal adaptation (kappa=0.81) and analyzed by Fisher's exact and Kruskal-Wallis tests, respectively. No significant differences were observed among groups after 18 months for any of the assessed criteria (p>0.05). The intra-group analysis performed by Cochran's test (for retention) and Wilcoxon test (for marginal adaptation/staining) revealed significant differences between the time intervals baseline/18 months in marginal adaptation (p= 0.0117) and retention (p= 0.0101) for OSSE and in marginal staining for TSER (0.0051) and EWBT (p= 0.0277) groups. The survival analysis for retention criteria and the overall clinical success were performed using a log-rank test and did not show significant differences among groups (p> 0.05). All three adhesives protocols presented similar clinical performance up to 18 months.


El propósito de este ensayo clínico aleatorizado fue evaluar, durante 18 meses, el éxito clínico de las restauraciones realizadas por la técnica de adhesión húmeda en etanol (TAHE) en comparación con las técnicas de grabado independiente de tres pasos (GTP) y de autograbado de un paso (AUP). Un solo operador, especializado en odontología restaurativa, realizó sobre 17 pacientes 93 restauraciones en lesiones cervicales no cariosas (31 para cada grupo). Los diferentes protocolos adhesivos se distribuyeron aleatoriamente en las lesiones cervicales hasta que los tres grupos estuviesen presentes en el mismo paciente y en cantidades iguales. Las restauraciones fueron evaluadas a los 6, 12 y 18 meses, por dos examinadores calibrados y que no participaron del procedimiento restaurador. Las directrices modificadas del Servicio de Salud Pública de Estados Unidos (SSPEU) fueron la base para las evaluaciones de las siguientes variables: retención (kappa= 1,00), adaptación y decoloración marginal (kappa= 0,81). Estas variables fueron analizadas mediante la prueba exacta de Fisher y Kruskal-Wallis, respectivamente. No se observó diferencia significativa entre los grupos después de 18 meses en las tres variables evaluadas (p >0,05). El análisis intra-grupo hecho por la prueba de Cochran (para la retención) y la prueba de Wilcoxon (para la adaptación y decoloración marginal) revelaron diferencias significativas entre los intervalos de tiempo de la línea de base / 18 meses para la retención (p= 0,0101) y adaptación marginal en el grupo AUP (p= 0,0117), y para la decoloración marginal en los grupos GTP (p= 0,0051) e TAHE (p= 0,0277). El análisis de supervivencia para la retención, así como la comparación del éxito clínico de los protocolos adhesivos, fueron realizados con la prueba de log-rank, y no hubo diferencias significativas (p >0,05) entre los grupos. No hubo diferencia en el éxito clínico de los tres protocolos adhesivos después de 18 meses.


Asunto(s)
Humanos , Masculino , Femenino , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Restauración Dental Permanente/métodos , Etanol/química , Grabado Ácido Dental/métodos , Ensayo de Materiales , Agua , Análisis de Supervivencia , Color , Adaptación Marginal Dental , Cementos de Resina/química , Dentina , Retención de la Prótesis
19.
Int. j. odontostomatol. (Print) ; 10(1): 135-142, abr. 2016. ilus
Artículo en Inglés | LILACS | ID: lil-782633

RESUMEN

Dentin hypersensitivity is a relatively common clinical condition, which affects a large part of the world's population. The objective of this study was to evaluate the influence of previous and prolonged treatment with desensitizing dentifrices (DD) on bond strength to dentin, promoted by a self-etching adhesive system. Seventy non-carious bovine incisors were used, and divided into five groups (n= 14), according to the desensitizing toothpaste used, such as, G1: distilled water (WATER) (control); G2: Colgate Total 12 (CT12) (control); G3: Colgate Sensitive Pro-Relief (CSPR); G4: Sensodyne Rapid Relief (SRR); G5: Sensodyne Repair & Protect (SRP). Teeth had their buccal surfaces flattened until the exposure of dentin, and fragments of 4x4x2 mm were obtained. Fragments were included in polyvinyl chloride (PVC) cylinders and exposed to 17 % EDTA for 1 min. Subsequently, specimens were submitted to 20 000 cycles of simulated dental toothbrushing. After 24 h in artificial saliva, specimens were hybridized (Clearfil SE Bond ­ Kuraray), as well as resin composite cylinders built on dentin surfaces. Samples were stored in distilled water, at 37 C for 24 h, and the shear bond strength was determined. The highest bond strength (MPa) value was seen in CT12 group (4.39), and the lowest one in CSPR group (3.34). Data were statistically analyzed by 1-way ANOVA (ð= 0.05), and results showed that there were no significant differences (p= 0.5986) considering the DD factor. The predominant fracture pattern was cohesive on dentin. The previous and prolonged use of different DD did not affect dentin bond strength promoted by a self-etching adhesive system.


La hipersensibilidad dentinaria es una condición clínica relativamente común, que afecta a una gran parte de la población mundial. El objetivo fue evaluar la influencia del tratamiento previo y prolongado con dentífricos desensibilizantes (DD) en fuerza de adhesión a la dentina, que promueve un sistema adhesivo de autograbado. Se utilizaron 70 incisivos bovinos no cariados, y se dividieron en cinco grupos (n= 14), de acuerdo con la pasta de dientes desensibilizante utilizada: G1: agua destilada (agua) (control), G2: Colgate Total 12 (CT12) (control), G3: Colgate Sensitive Pro-Alivio (CSPR), G4: Sensodyne Rápido Alivio (SRR) y G5: Sensodyne Repair & Protect (SRP). Los dientes tenían sus superficies bucales aplanadas hasta la exposición de la dentina, y se obtuvieron fragmentos de 4x4x2 mm. Los fragmentos se incluyeron en cilindros de cloruro de polivinilo y se expusieron a 17 % de EDTA durante un 1 min. Después, las muestras se sometieron a 20 000 ciclos de cepillado dental simulado. Después de 24 h en saliva artificial, las muestras se hibridaron (Clearfil SE Bond - Kuraray), y cilindros de resina compuesta fueron construidos sobre superficies de dentina. Las muestras se almacenaron en agua destilada, a 37 °C durante 24 h y luego se determinó la resistencia al cizallamiento. El mayor valor de resistencia a la unión (MPa) se observó en el grupo CT12 (4,39), y el menor en el grupo CSPR (3,34). Los datos fueron analizados estadísticamente mediante ANOVA de un factor 1 (ð= 0,05), y los resultados no mostraron diferencias significativas (p= 0,5986) teniendo en cuenta el factor de los DD. El patrón de fractura predominante sobre la dentina fue el cohesivo. El uso previo y prolongado de diferente DD no afectó resistencia de unión a la dentina promovido por un sistema adhesivo de autograbado.


Asunto(s)
Animales , Recubrimientos Dentinarios , Dentífricos/farmacología , Dentina/efectos de los fármacos , Sensibilidad de la Dentina/tratamiento farmacológico , Desensibilizantes Dentinarios/farmacología , Estrés Mecánico , Factores de Tiempo , Adhesivos , Análisis de Varianza , Grabado Dental
20.
Int. j. odontostomatol. (Print) ; 9(3): 497-504, dic. 2015. ilus
Artículo en Inglés | LILACS | ID: lil-775478

RESUMEN

Bleaching procedures can interfere on adhesive bonding of methacrylate-based restorative materials. After introduction of silorane-based composites, little information is available about this interaction. The objective is evaluate the influence of bleaching on enamel shear bond strength of silorane-based restorative system. Forty sound incisive bovine teeth were randomly divided into 04 groups (n= 10), being: G1 (control) ­ not bleached + Clearfil SE Bond (CSEB)/Filtek Z250 (Z250), G2 (control) not bleached + Silorane Adhesive (SA)/Filtek P90 (P90), G3 ­ bleached + CSEB/Z250; G4 ­ bleached + SA/P90. The teeth were sectioned, had crowns included in a PVC rings, and the enamel surfaces gridded and polished with silicon carbide abrasive papers. G1 and G2 were stored in artificial saliva (37 C), daily renewed, for a period of 04 days. G3 and G4 were exposed to 02 sessions of 38% hydrogen peroxide (38HP), with 03 applications of 15 min in each session. Composite resin cylinders were built up on the enamel surfaces. Bonding procedures were performed according the manufacturer's instructions. After storage in distilled water for 24 h (37 C), the samples were submitted to shear bond test. Data were analyzed by two-way ANOVA and t (LSD) tests (5%). Intra group comparison showed significant difference for Z250 after bleaching, but not for P90. Shear strength was significant lower for P90, despite bleaching procedures. In conclusion, 38HP bleaching had no influence on the enamel bond strength of P90, even though presenting lower bond strength than Z250.


Los procedimientos de blanqueamiento dental pueden interferir en la unión adhesiva de los materiales de restauración a base de metacrilato. Después de la introducción de materiales compuestos a base de silorano, hay poca información disponible acerca de esta interacción. El objetivo fue evaluar la influencia del blanqueamiento en la cizalladura de la fuerza de adhesion sobre esmalte del sistema restaurativo a base de silorano. Cuarenta dientes incisivos bovinos fueron divididos aleatoriamente en 4 grupos (n= 10), siendo: G1 (control) - no aclarado + Clearfil SE Bond (CSEB)/Filtek Z250 (z250), G2 (control) - no aclarado + adhesivo de silorane (AS)/Filtek P90 (P90), G3 - aclarado + CSEB / Z250; g4 - aclarado + AS/P90. Los dientes fueron seccionados, tenían coronas incluidas en anillos de pvc, y las superficies de esmalte fueron molidas y pulidas con papeles abrasivos de silicona de silicio. G1 y G2 fueron almacenados en saliva artificial (37 °C), renovada diariamente, durante un período de 04 días. G3 y G4 se expusieron a 2 sesiones de peróxido de hidrógeno al 38% (38 HP) con 03 aplicaciones de 15 min en cada sesión. Los cilindros de resina compuesta fueron construidos en las superficies de esmalte. Los procedimientos de unión se realizaron según las instrucciones del fabricante. Después del almacenamiento en agua destilada durante 24 h (37 °C), las muestras fueron sometidas al ensayo de resistencia de adhesión al cizallamiento. Los datos fueron analizados por ANOVA de dos vías y prueba t (5%). La comparación intragrupo mostró diferencias significativas para Z250 después del aclaramiento, pero no para P90. La resistencia al corte fue significativamente menor para P90, a pesar de los procedimientos de blanqueamiento. En conclusión, el blanqueamiento con 38HP no tuvo influencia en la resistencia de la unión esmalte de P90, a pesar de presentar una fuerza de unión más baja que Z250.


Asunto(s)
Animales , Bovinos , Blanqueamiento de Dientes , Resistencia al Corte , Resinas de Silorano , Resinas Compuestas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA