Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
1.
Diabetes Res Clin Pract ; 212: 111719, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38789009

RESUMEN

AIMS: We assessed association between how teens with type 1 diabetes (T1D) perceived a text-messaging (TM) reminder system to check glucose levels and how their perceptions related to their responsiveness to TM reminders to check glucose levels. METHODS: Teens received TM reminders 1-4 times daily to check glucose levels and to reply with the result. Qualitative assessments were performed quarterly. Teens were categorized by perceptions expressed at the majority of the visits and their TM responsiveness over 18 months. RESULTS: There were 135 teens (51 % male), with a mean age of 14.8 ± 1.2 years, receiving TM reminders. Distribution of participants' perceptions was 37 % positive (POS), 35 % neutral (with both positive and negative responses (POS/NEG)), and 28 % negative (NEG). Teens with POS perceptions about TM reminders were more likely to respond with a glucose value to the TM reminders than teens with NEG or POS/NEG perceptions (p = 0.002). Youth with POS perceptions and TM responsiveness on ≥ 50 % of days had an 0.81 % improvement in their HbA1c (p = 0.004) over 18 months. CONCLUSIONS: Teens with POS perceptions to TM reminders were likely to respond and their responsiveness yielded glycemic benefit, suggesting need to consider opinions of teens with T1D to maximize their intervention engagement and resulting benefits.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38696672

RESUMEN

Objective: To evaluate the safety and explore the efficacy of use of ultra-rapid lispro (URLi, Lyumjev) insulin in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology in children, teenagers, and adults living with type 1 diabetes (T1D). Methods: At 14 U.S. diabetes centers, youth and adults with T1D completed a 16-day lead-in period using lispro in a t:slim X2 insulin pump with Control-IQ 1.5 technology, followed by a 13-week period in which URLi insulin was used in the pump. Results: The trial included 179 individuals with T1D (age 6-75 years). With URLi, 1.7% (3 participants) had a severe hypoglycemia event over 13 weeks attributed to override boluses or a missed meal. No diabetic ketoacidosis events occurred. Two participants stopped URLi use because of infusion-site discomfort, and one stopped after developing a rash. Mean time 70-180 mg/dL increased from 65% ± 15% with lispro to 67% ± 13% with URLi (P = 0.004). Mean insulin treatment satisfaction questionnaire score improved from 75 ± 13 at screening to 80 ± 11 after 13 weeks of URLi use (mean difference = 6; 95% confidence interval 4-8; P < 0.001), with the greatest improvement reported for confidence avoiding symptoms of high blood sugar. Mean treatment-related impact measure-diabetes score improved from 74 ± 12 to 80 ± 12 (P < 0.001), and mean TRIM-Diabetes Device (score improved from 82 ± 11 to 86 ± 12 (P < 0.001). Conclusions: URLi use in the Tandem t:slim X2 insulin pump with Control-IQ 1.5 technology was safe for adult and pediatric participants with T1D, with quality-of-life benefits of URLi use perceived by the study participants. Clinicaltrials.gov registration: NCT05403502.

3.
Front Clin Diabetes Healthc ; 5: 1332159, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38774897

RESUMEN

Introduction: Emerging adulthood is challenging for young people with type 1 diabetes (T1D). This study evaluated transition to diabetes self-management and perceptions of care transfer using mixed methods. Methods: An online survey queried demographics, management characteristics, diabetes knowledge, self-care readiness, adherence, and diabetes distress. T-tests compared survey scores between those with self-reported target A1c <7.0% versus ≥7.0%. Pearson correlations assessed associations between A1c and diabetes distress, stratified by A1c <7.0% versus ≥7.0%. Qualitative semi-structured interviews elicited perceptions of young adults; transcripts were analyzed using directed qualitative content analysis. Results: Of 141 participants (30% male, 84% non-Hispanic white) completing the survey, 41% self-reported target A1c <7.0%. Diabetes knowledge and self-care readiness scores did not differ between those with A1c <7.0% versus ≥7.0%, while diabetes distress was lower (45 ± 20 vs 52 ± 20, p=0.01) and adherence higher (77 ± 12 vs 71 ± 14, p=0.02) in those with A1c <7.0% versus ≥7.0%. Diabetes distress was significantly associated with glycemic outcomes in those reporting A1c ≥7.0% (R=0.36, p<0.01). Qualitative analysis (24 participants) revealed five themes and two sub-themes, notable for need for more mental health support, support from others with T1D, benefits of technology for care autonomy, and challenges of obtaining diabetes supplies. Discussion: Emerging adults with self-reported target A1c endorsed lower diabetes distress and higher adherence than those with elevated A1c. Mental health access, support from others with T1D, technology use, and guidance for supply acquisition may improve transition to self-management and care transfer for emerging adults with T1D.

4.
Diabetes Ther ; 15(5): 893-896, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38578395

RESUMEN

The increasing occurrence of childhood overweight and obesity has been followed by a substantial increase in youth-onset type 2 diabetes (T2D). Pharmacological treatment options for youth-onset T2D remain limited, with a clear unmet need for additional oral agents. This summary of research reports on the efficacy and safety of empagliflozin and linagliptin on glycaemic control in children and adolescents aged 10-17 years with T2D in the randomised, double-blind, parallel group, phase 3 DINAMO trial. Empagliflozin provided a clinically relevant, statistically significant, and durable improvement in glycaemic control; however, linagliptin did not. The safety profile of both empagliflozin and linagliptin was comparable to those observed in studies in adults. These results suggest that empagliflozin could be a new oral therapy option for youth-onset T2D.

5.
JAMA Netw Open ; 7(2): e240447, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38421647

RESUMEN

Importance: Youth-onset type 2 diabetes (T2D) has a more aggressive phenotype than adult-onset T2D, including rapid loss of glycemic control and increased complication risk. Objective: To identify associations of growth hormone mediators with glycemic failure, beta cell function, and insulin sensitivity in youth-onset T2D. Design, Setting, and Participants: This post hoc secondary analysis of the Treatment Options for Type 2 Diabetes in Adolescents and Youth (TODAY) randomized clinical trial, which enrolled participants from July 2004 to February 2009, included 398 participants from 15 university-affiliated medical centers with available plasma samples from baseline and 36 months. Participants were youths aged 10 to 17 years with a duration of T2D of less than 2 years who were randomized to metformin, metformin plus lifestyle intervention, or metformin plus rosiglitazone. Participants were followed up for a mean (SD) of 3.9 (1.5) years during the trial, ending in 2011. Statistical analysis was performed from August 2022 to November 2023. Exposure: Plasma insulin-like growth factor-1 (IGF-1), growth hormone receptor (GHR), and insulin-like growth factor binding protein 1 (IGFBP-1). Main Outcomes and Measures: Main outcomes were (1) loss of glycemic control during the TODAY study, defined as hemoglobin A1c (HbA1c) level of 8% or more for 6 months or inability to wean from insulin therapy, and (2) baseline and 36-month measures of glycemia (fasting glucose, HbA1c), insulin sensitivity (1/fasting C-peptide), high-molecular-weight adiponectin, and beta cell function (C-peptide index, C-peptide oral disposition index). Results: This analysis included 398 participants (mean [SD] age, 13.9 [2.0] years; 248 girls [62%]; 166 Hispanic participants [42%]; 134 non-Hispanic Black participants [34%], and 84 non-Hispanic White participants [21%]). A greater increase in IGF-1 level between baseline and 36 months was associated with lower odds of glycemic failure (odds ratio [OR], 0.995 [95% CI, 0.991-0.997]; P < .001) and higher C-peptide index per 100-ng/mL increase in IGF-1 (ß [SE], 0.015 [0.003]; P < .001). A greater increase in log2 GHR level between baseline and 36 months was associated with higher odds of glycemic failure (OR, 1.75 [95% CI, 1.05-2.99]; P = .04) and lower C-peptide index (ß [SE], -0.02 [0.006]; P < .001). A greater increase in log2 IGFBP-1 level between baseline and 36 months was associated with higher odds of glycemic failure (OR, 1.37 [95% CI, 1.09-1.74]; P = .007) and higher high-molecular-weight adiponectin (ß [SE], 431 [156]; P = .007). Conclusions and Relevance: This study suggests that changes in plasma growth hormone mediators are associated with loss of glycemic control in youth-onset T2D, with IGF-1 associated with lower risk and GHR and IGFBP-1 associated with increased risk. Trial Registration: ClinicalTrials.gov Identifier: NCT00081328.


Asunto(s)
Diabetes Mellitus Tipo 2 , Resistencia a la Insulina , Metformina , Adulto , Femenino , Adolescente , Humanos , Hormona del Crecimiento , Proteína 1 de Unión a Factor de Crecimiento Similar a la Insulina , Factor I del Crecimiento Similar a la Insulina , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Control Glucémico , Adiponectina , Péptido C , Hemoglobina Glucada , Metformina/uso terapéutico
6.
Diabetes Technol Ther ; 26(5): 307-312, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38315503

RESUMEN

Background: We evaluated accuracy and safety of a seventh-generation real-time continuous glucose monitoring (CGM) system during pregnancy. Materials and Methods: Evaluable data for accuracy analysis were obtained from 96 G7 sensors (Dexcom, Inc.) worn by 96 of 105 enrolled pregnant women with type 1 (n = 59), type 2 (n = 21), or gestational diabetes (n = 25). CGM values were compared with arterialized venous glucose values from the YSI comparator instrument during 6-h clinic sessions at different time points throughout the sensors' 10-day wear period. The primary endpoint was the proportion of CGM values in the 70-180 mg/dL range within 15% of comparator glucose values. Secondary endpoints included the proportion of CGM values within 20% or 20 mg/dL of comparator values ≥ or <100 mg/dL, respectively (the %20/20 agreement rate). Results: Of the 1739 pairs with CGM in the 70-180 mg/dL range, 83.2% were within 15% of comparator values. The lower bound of the 95% confidence interval was 79.8%. Of the 2102 pairs with CGM values in the 40-400 mg/dL range, the %20/20 agreement rate was 92.5%. Of the 1659 pairs with comparator values in the 63-140 mg/dL range, the %20/20 agreement rate was 92.3%. The %20/20 agreement rates on days 1, 4 and 7, and 10 were 78.6%, 96.3%, and 97.3%, respectively. Consensus error grid analysis showed 99.8% of pairs in the clinically acceptable A and B zones. There were no serious adverse events. The sensors' 10-day survival rate was 90.3%. Conclusion: The G7 system is accurate and safe during pregnancies complicated by diabetes and does not require confirmatory fingerstick testing. Clinical Trial Registration: clinicaltrials.gov NCT04905628.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Diabetes Gestacional , Embarazo en Diabéticas , Humanos , Femenino , Embarazo , Adulto , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Embarazo en Diabéticas/sangre , Embarazo en Diabéticas/tratamiento farmacológico , Diabetes Gestacional/sangre , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Adulto Joven , Monitoreo Continuo de Glucosa
7.
Diabetes Care ; 47(6): 941-947, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38295397

RESUMEN

OBJECTIVE: To determine how diabetes technologies, including continuous glucose monitoring (CGM) and automated insulin delivery (AID) systems, impact glycemic metrics, prevalence of severe hypoglycemic events (SHEs), and impaired awareness of hypoglycemia (IAH) in people with type 1 diabetes in a real-world setting within the U.S. RESEARCH DESIGN AND METHODS: In this retrospective, observational study with cross-sectional elements, participants aged ≥18 years were enrolled from the T1D Exchange Registry/online community. Participants completed a one-time online survey describing glycemic metrics, SHEs, and IAH. The primary objective was to determine the proportions of participants who reported achieving glycemic targets (assessed according to self-reported hemoglobin A1c) and had SHEs and/or IAH. We performed additional subgroup analyses focusing on the impact of CGM and insulin delivery modality. RESULTS: A total of 2,074 individuals with type 1 diabetes were enrolled (mean ± SD age 43.0 ± 15.6 years and duration of type 1 diabetes 26.3 ± 15.3 years). The majority of participants (91.7%) were using CGM, with one-half (50.8%) incorporating AID. Despite high use of diabetes technologies, only 57.7% reported achieving glycemic targets (hemoglobin A1c <7%). SHEs and IAH still occurred, with ∼20% of respondents experiencing at least one SHE within the prior 12 months and 30.7% (95% CI 28.7, 32.7) reporting IAH, regardless of CGM or AID use. CONCLUSIONS: Despite use of advanced diabetes technologies, a high proportion of people with type 1 diabetes do not achieve glycemic targets and continue to experience SHEs and IAH, suggesting an ongoing need for improved treatment strategies.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Estudios Transversales , Femenino , Adulto , Masculino , Hipoglucemia/epidemiología , Persona de Mediana Edad , Estudios Retrospectivos , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Insulina/administración & dosificación , Glucemia/metabolismo , Hemoglobina Glucada/metabolismo , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación
8.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38277156

RESUMEN

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Hemoglobina Glucada , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Preescolar , Insulina/administración & dosificación , Insulina/uso terapéutico , Femenino , Masculino , Glucemia/análisis , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada/análisis , Hipoglucemia/prevención & control , Resultado del Tratamiento , Control Glucémico/métodos , Automonitorización de la Glucosa Sanguínea
9.
Diabetes Technol Ther ; 26(6): 420-425, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38277162

RESUMEN

Objective: Insulin bolus doses derive from glucose levels and planned carbohydrate intake, although fat and protein impact glycemic excursions. We examined the impact of macronutrients and number of daily meals/snacks on glycemic outcomes in youth with type 1 diabetes. Methods: Youth (N = 136, ages 8-17) with type 1 diabetes completed 3-day food records, wore 3-day masked continuous glucose monitoring, and had A1c measurements every 3 months for 1 year. Diet data were analyzed using Nutrition Data System for Research. Longitudinal mixed models assessed effects of macronutrient intake and number of meals/snacks on glycemic outcomes. Results: At baseline, youth (48% male) had mean age of 12.8 ± 2.5 years and diabetes duration of 5.9 ± 3.1 years; 73% used insulin pumps. Baseline A1c was 8.1% ± 1.0%, percent time in range 70-180 mg/dL (%TIR) was 49% ± 17%, % time below range <70 mg/dL (%TBR) was 6% ± 8%, % time above range >180 mg/dL (%TAR) was 44% ± 20%, and glycemic variability as coefficient of variation (CV) was 41% ± 8%; macronutrient intake included 48% ± 5% carbohydrate, 36% ± 5% fat, and 16% ± 2% protein. Most youth (56%) reported 3-4 meals/snacks daily (range 1-9). Over 1 year, greater carbohydrate intake was associated with lower A1c (P = 0.0003), more %TBR (P = 0.0006), less %TAR (P = 0.002), and higher CV (P = 0.03). Greater fat intake was associated with higher A1c (P = 0.006), less %TBR (P = 0.002), and more %TAR (P = 0.005). Greater protein intake was associated with higher A1c (P = 0.01). More daily meals/snacks were associated with lower A1c (P = 0.001), higher %TIR (P = 0.0006), and less %TAR (P = 0.0001). Conclusions: Both fat and protein impact glycemic outcomes. Future automated insulin delivery systems should consider all macronutrients for timely insulin provision. The present research study derived from secondary analysis of the study registered under NCT00999375.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Insulina , Comidas , Humanos , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Masculino , Adolescente , Femenino , Niño , Glucemia/análisis , Insulina/administración & dosificación , Insulina/uso terapéutico , Hemoglobina Glucada/análisis , Nutrientes/administración & dosificación , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/uso terapéutico , Carbohidratos de la Dieta/administración & dosificación , Automonitorización de la Glucosa Sanguínea , Control Glucémico , Sistemas de Infusión de Insulina , Ingestión de Energía , Grasas de la Dieta/administración & dosificación
11.
Nat Metab ; 6(2): 226-237, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38278947

RESUMEN

The prevalence of youth-onset type 2 diabetes (T2D) and childhood obesity has been rising steadily1, producing a growing public health concern1 that disproportionately affects minority groups2. The genetic basis of youth-onset T2D and its relationship to other forms of diabetes are unclear3. Here we report a detailed genetic characterization of youth-onset T2D by analysing exome sequences and common variant associations for 3,005 individuals with youth-onset T2D and 9,777 adult control participants matched for ancestry, including both males and females. We identify monogenic diabetes variants in 2.4% of individuals and three exome-wide significant (P < 2.6 × 10-6) gene-level associations (HNF1A, MC4R, ATXN2L). Furthermore, we report rare variant association enrichments within 25 gene sets related to obesity, monogenic diabetes and ß-cell function. Many youth-onset T2D associations are shared with adult-onset T2D, but genetic risk factors of all frequencies-and rare variants in particular-are enriched within youth-onset T2D cases (5.0-fold increase in the rare variant and 3.4-fold increase in common variant genetic liability relative to adult-onset cases). The clinical presentation of participants with youth-onset T2D is influenced in part by the frequency of genetic risk factors within each individual. These findings portray youth-onset T2D as a heterogeneous disease situated on a spectrum between monogenic diabetes and adult-onset T2D.


Asunto(s)
Diabetes Mellitus Tipo 2 , Obesidad Infantil , Masculino , Adulto , Femenino , Humanos , Adolescente , Niño , Diabetes Mellitus Tipo 2/epidemiología , Diabetes Mellitus Tipo 2/genética , Exoma , Estudio de Asociación del Genoma Completo , Biología
12.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37850941

RESUMEN

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Niño , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Hemoglobina Glucada , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea
13.
J Diabetes Sci Technol ; : 19322968231209339, 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37946403

RESUMEN

BACKGROUND: An increasing number of individuals with type 1 diabetes (T1D) manage glycemia with insulin pumps containing short-acting insulin. If insulin delivery is interrupted for even a few hours due to pump or infusion site malfunction, the resulting insulin deficiency can rapidly initiate ketogenesis and diabetic ketoacidosis (DKA). METHODS: To detect an event of accidental cessation of insulin delivery, we propose the design of ketone-based alert system (K-AS). This system relies on an extended Kalman filter based on plasma 3-beta-hydroxybutyrate (BOHB) measurements to estimate the disturbance acting on the insulin infusion/injection input. The alert system is based on a novel physiological model capable of simulating the ketone body turnover in response to a change in plasma insulin levels. Simulated plasma BOHB levels were compared with plasma BOHB levels available in the literature. We evaluated the performance of the K-AS on 10 in silico subjects using the S2014 UVA/Padova simulator for two different scenarios. RESULTS: The K-AS achieves an average detection time of 84 and 55.5 minutes in fasting and postprandial conditions, respectively, which compares favorably and improves against a detection time of 193 and 120 minutes, respectively, based on the current guidelines. CONCLUSIONS: The K-AS leverages the rapid rate of increase of plasma BOHB to achieve short detection time in order to prevent BOHB levels from rising to dangerous levels, without any false-positive alarms. Moreover, the proposed novel insulin-BOHB model will allow us to understand the efficacy of treatment without compromising patient safety.

14.
Commun Med (Lond) ; 3(1): 132, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37794113

RESUMEN

BACKGROUND: The greatest change in the treatment of people living with type 1 diabetes in the last decade has been the explosion of technology assisting in all aspects of diabetes therapy, from glucose monitoring to insulin delivery and decision making. As such, the aim of our systematic review was to assess the utility of these technologies as well as identify any precision medicine-directed findings to personalize care. METHODS: Screening of 835 peer-reviewed articles was followed by systematic review of 70 of them (focusing on randomized trials and extension studies with ≥50 participants from the past 10 years). RESULTS: We find that novel technologies, ranging from continuous glucose monitoring systems, insulin pumps and decision support tools to the most advanced hybrid closed loop systems, improve important measures like HbA1c, time in range, and glycemic variability, while reducing hypoglycemia risk. Several studies included person-reported outcomes, allowing assessment of the burden or benefit of the technology in the lives of those with type 1 diabetes, demonstrating positive results or, at a minimum, no increase in self-care burden compared with standard care. Important limitations of the trials to date are their small size, the scarcity of pre-planned or powered analyses in sub-populations such as children, racial/ethnic minorities, people with advanced complications, and variations in baseline glycemic levels. In addition, confounders including education with device initiation, concomitant behavioral modifications, and frequent contact with the healthcare team are rarely described in enough detail to assess their impact. CONCLUSIONS: Our review highlights the potential of technology in the treatment of people living with type 1 diabetes and provides suggestions for optimization of outcomes and areas of further study for precision medicine-directed technology use in type 1 diabetes.


In the last decade, there have been significant advances in how technology is used in the treatment of people living with type 1 diabetes. These technologies primarily aim to help manage blood sugar levels. Here, we reviewed research published over the last decade to evaluate the impact of such technologies on type 1 diabetes treatment. We find that various types of novel technologies, such as devices to monitor blood sugar levels continuously or deliver insulin, improve important diabetes-related measures and can reduce the risk of having low blood sugar levels. Importantly, several studies showed a positive impact of technologies on quality of life in people living with diabetes. Our findings highlight the benefits of novel technologies in the treatment of type 1 diabetes and identify areas for further research to optimize and personalize diabetes care.

16.
Diabetes Spectr ; 36(3): 205-210, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37583558

RESUMEN

Objective: School nurses are integral to optimizing diabetes management for students with type 1 diabetes. The aim of this study was to describe the use of diabetes technology in schools over time and assess school nurses' comfort level performing diabetes management tasks. Study design: From 2012 to 2019, school nurses who attended a diabetes education program completed a survey about their experience and comfort level with diabetes management. Results: A total of 1,796 school nurses completed the survey; 56% had at least 5 years of school nursing experience. Most (86%) had at least one student with type 1 diabetes. Among school nurses with at least one student with type 1 diabetes, 73% had at least one student using insulin pump therapy, and 48% had at least one student using continuous glucose monitoring (CGM). There was no change in pump use over time, but the percentage of nurses who had a student using CGM increased significantly from 24% in 2012 to 86% in 2019 (P <0.001). School nurses' comfort level using pumps remained stable over time. Overall, 47% reported being mostly/very comfortable giving boluses using a pump, and 17% reported being mostly/very comfortable troubleshooting problems with a pump. However, there was a significant increase in school nurses reporting feeling mostly/very comfortable working with CGM devices, increasing from 9% in 2012 to 44% in 2019 (P <0.001). Conclusion: School nurses are an important part of diabetes management for school-aged youth with type 1 diabetes. There is a need for additional diabetes education and support to build their confidence with diabetes management and technology, especially with further technological advancements in management.

17.
JCEM Case Rep ; 1(3): luad046, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37223066

RESUMEN

Hypertriglyceridemia is a complication of diabetic ketoacidosis (DKA) secondary to insulin deficiency inhibiting lipoprotein lipase and increasing lipolysis, but it is rare in children. A 7-year-old boy with history of autism spectrum disorder (ASD) presented with abdominal pain, vomiting, and "heavy breathing." Initial laboratory tests revealed pH 6.87 and glucose 385 mg/dL (21.4 mmol/L), consistent with new-onset diabetes and DKA. His blood appeared lipemic; triglycerides were 17 675 mg/dL (199.6 mmol/L) with normal lipase (10 units/L). He received intravenous insulin and DKA resolved within 24 hours. Insulin infusion continued through day 6 for management of hypertriglyceridemia; triglycerides decreased to 1290 mg/dL (14.6 mmol/L) during this period. He never developed pancreatitis (lipase peaked at 68 units/L) or required plasmapheresis. With his ASD history, he had a restrictive diet high in saturated fat, which included up to 30 breakfast sausages daily. His triglycerides normalized after discharge. Severe hypertriglyceridemia can complicate DKA in newly diagnosed type 1 diabetes (T1D). Hypertriglyceridemia can be safely managed with insulin infusion in the absence of end-organ dysfunction. This complication should be considered in patients with DKA at diagnosis of T1D.

18.
Diabet Med ; 40(8): e15120, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37083018

RESUMEN

AIM: Managing type 1 diabetes in young children can cause significant stress for parents. Continuous glucose monitoring (CGM) may reduce parental burden. The Strategies to Enhance CGM Use in Early Childhood (SENCE) trial randomized parents of children (ages 2 to <8 years) with type 1 diabetes to CGM with family behavioural intervention (CGM + FBI), CGM alone (Standard-CGM) or blood glucose monitoring for 26 weeks before receiving CGM + FBI (BGM-Crossover). This report assesses changes in psychosocial outcomes for all groups over 52 weeks. METHODS: CGM + FBI (n = 45), Standard-CGM (n = 42) and BGM-Crossover (n = 44) participants completed psychosocial assessments at baseline, 26 weeks and 52 weeks. Repeated measures linear regression models evaluated change within and between treatment groups. RESULTS: The BGM-Crossover group reported improved diabetes burden (Δ -6.9, 95% CI [-11.3, -2.6], p = 0.003), fear of hypoglycaemia (Δ -6.4, CI [-10.1, -2.6], p = 0.002) and technology satisfaction (Δ 7.3, CI [2.4, 12.2], p = 0.005) from 26 to 52 weeks, similar to published findings in the CGM + FBI group over the first 26 weeks. The Standard-CGM group reported increased technology satisfaction (Δ 7.3, CI [0.6, 14.0], p = 0.027) from baseline to 52 weeks. The CGM + FBI group reported less diabetes burden and fear of hypoglycaemia from baseline to 52 weeks, but changes were not statistically significant. Scores from 26 to 52 weeks did not deteriorate. CONCLUSIONS: Parents demonstrated psychosocial benefits following FBI that appeared to maintain without additional intervention. CGM-focused education with behavioural support likely helps parents of young children with type 1 diabetes reduce burden and worry in the short- and long-term.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Niño , Preescolar , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Padres/psicología
19.
J Diabetes Sci Technol ; : 19322968231159411, 2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-36912009

RESUMEN

AIM: We added items relevant to continuous glucose monitoring (CGM) to the Diabetes Family Conflict Scale (DFC), Diabetes Family Responsibility Questionnaire (DFR), and Blood Glucose Monitoring Communication Questionnaire (GMC) and evaluated the psychometric properties of the updated surveys. RESEARCH DESIGN AND METHODS: Youth with type 1 diabetes who recently started CGM and their parents completed the updated surveys and additional psychosocial surveys. Medical data were collected from self-reports and review of the medical record. RESULTS: Youth (N = 114, 49% adolescent girls) were aged 13.3 ± 2.7 years and had mean glycated hemoglobin (HbA1c) 7.9 ± 0.9%; 87% of them used pump therapy. The updated surveys demonstrated high internal consistency (DFC youth: α = .91, parent: α = .81; DFR youth: α = .88, parent: α = .93; and GMC youth: α = .88, parent: α = .86). Higher youth and parent DFC scores (more diabetes-specific family conflict) and GMC scores (more negative affect related to glucose monitoring) were associated with more youth and parent depressive symptoms (r = 0.28-0.60, P ≤ .003), more diabetes burden (r = 0.31-0.71, P ≤ .0009), more state anxiety (r = 0.24 to r = 0.46, P ≤ .01), and lower youth quality of life (r = -0.29 to -0.50, P ≤ .002). Higher youth and parent DFR scores (more parent involvement in diabetes management) were associated with younger youth age (youth: r = -0.76, P < .0001; parent: r = -0.81, P < .0001) and more frequent blood glucose monitoring (youth: r = 0.27, P = .003; parent: r = 0.35, P = .0002). CONCLUSIONS: The updated DFC, DFR, and GMC surveys maintain good psychometric properties. The addition of CGM items expands the relevance of these surveys for youth with type 1 diabetes who are using CGM and other diabetes technologies.

20.
Lancet Diabetes Endocrinol ; 11(3): 169-181, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36738751

RESUMEN

BACKGROUND: The incidence of type 2 diabetes in young people is increasing, but treatments remain limited. We aimed to assess the efficacy and safety of an empagliflozin dosing regimen versus placebo and linagliptin versus placebo on glycaemic control in young people with type 2 diabetes. METHODS: In this double-blind, placebo-controlled trial done in 108 centres in 15 countries, participants with type 2 diabetes (aged 10-17 years; HbA1c 6·5-10·5% [48-91 mmol/mol]) who had been previously treated with metformin or insulin were randomly assigned (1:1:1) to oral empagliflozin 10 mg, oral linagliptin 5 mg, or placebo. Participants in the empagliflozin group who did not have HbA1c below 7·0% (<53 mmol/mol) by week 12 underwent a second double-blinded randomisation (1:1) at week 14, either remaining on 10 mg or increasing to 25 mg. Participants in the placebo group were randomly reassigned (1:1:1) in a double-blinded manner at week 26 to linagliptin 5 mg or one of the empagliflozin doses (10 mg or 25 mg). Investigators were masked throughout the trial and received assignments of blinded medication kits through interactive response technology for all participants at the initial randomisation and for the re-randomisations at weeks 14 and 26. The primary outcome was change from baseline in HbA1c at 26 weeks. For empagliflozin, results were based on a pooled analysis for all participants on empagliflozin. Safety was assessed until week 52. This trial is registered with ClinicalTrials.gov, NCT03429543. FINDINGS: Between April 26, 2018, and May 26, 2022, of 262 screened participants, 158 (60%) were randomly assigned to treatment (53 [34%] to placebo, 52 [33%] to empagliflozin 10 mg, and 53 [34%] to linagliptin). For the primary outcome, the adjusted mean HbA1c change from baseline at week 26 was -0·84% [-9·2 mmol/mol] in the empagliflozin pooled group versus placebo (95% CI -1·50 to -0·19 [-16·4 to -2·1]; p=0·012); the corresponding change from baseline for linagliptin versus placebo was -0·34% [-3·8 mmol/mol; 95% CI -0·99 to 0·30 [-10·8 to 3·3]; p=0·29). Adverse events occurred in 34 (64%) participants in the placebo group, 40 (77%) in the empagliflozin pooled group, and 37 (71%) in the linagliptin group, up to week 26. Of these, severe adverse events were reported in two (4%) participants in the placebo group, one (2%) in the empagliflozin pooled group, and one (2%) in the linagliptin group. Hypoglycaemia was the most frequently reported adverse event with higher rates for those on active drug treatment compared with placebo. No severe hypoglycaemia cases were reported. INTERPRETATION: Empagliflozin provided clinically relevant placebo-corrected reductions in HbA1c, whereas linagliptin did not, and might offer a new treatment option for young people with type 2 diabetes. FUNDING: The Boehringer Ingelheim and Eli Lilly and Company Alliance.


Asunto(s)
Diabetes Mellitus Tipo 2 , Inhibidores de la Dipeptidil-Peptidasa IV , Hipoglucemia , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Adolescente , Humanos , Glucemia , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Inhibidores de la Dipeptidil-Peptidasa IV/uso terapéutico , Método Doble Ciego , Hipoglucemia/inducido químicamente , Hipoglucemiantes/uso terapéutico , Linagliptina/uso terapéutico , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Resultado del Tratamiento , Niño
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA