Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
2.
J Am Heart Assoc ; 7(8)2018 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-29622592

RESUMEN

BACKGROUND: We aimed to evaluate a novel method of atrial fibrillation (AF) screening using an iPhone camera to detect and analyze photoplethysmographic signals from the face without physical contact by extracting subtle beat-to-beat variations of skin color that reflect the cardiac pulsatile signal. METHODS AND RESULTS: Patients admitted to the cardiology ward of the hospital for clinical reasons were recruited. Simultaneous facial and fingertip photoplethysmographic measurements were obtained from 217 hospital inpatients (mean age, 70.3±13.9 years; 71.4% men) facing the front camera and with an index finger covering the back camera of 2 independent iPhones before a 12-lead ECG was recorded. Backdrop and background light intensity was monitored during signal acquisition. Three successive 20-second (total, 60 seconds) recordings were acquired per patient and analyzed for heart rate regularity by Cardiio Rhythm (Cardiio Inc, Cambridge, MA) smartphone application. Pulse irregularity in ≥1 photoplethysmographic readings or 3 uninterpretable photoplethysmographic readings were considered a positive AF screening result. AF was present on 12-lead ECG in 34.6% (n=75/217) patients. The Cardiio Rhythm facial photoplethysmographic application demonstrated high sensitivity (95%; 95% confidence interval, 87%-98%) and specificity (96%; 95% confidence interval, 91%-98%) in discriminating AF from sinus rhythm compared with 12-lead ECG. The positive and negative predictive values were 92% (95% confidence interval, 84%-96%) and 97% (95% confidence interval, 93%-99%), respectively. CONCLUSIONS: Detection of a facial photoplethysmographic signal to determine pulse irregularity attributable to AF is feasible. The Cardiio Rhythm smartphone application showed high sensitivity and specificity, with low negative likelihood ratio for AF from facial photoplethysmographic signals. The convenience of a contact-free approach is attractive for community screening and has the potential to be useful for distant AF screening.


Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Cara/fisiopatología , Frecuencia Cardíaca/fisiología , Tamizaje Masivo/métodos , Fotopletismografía/métodos , Teléfono Inteligente , Anciano , Fibrilación Atrial/fisiopatología , Electrocardiografía , Diseño de Equipo , Femenino , Humanos , Masculino , Aplicaciones Móviles , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA