Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Int J Mol Sci ; 25(11)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38892442

RESUMEN

Biopharmaceutical products, in particular messenger ribonucleic acid (mRNA), have the potential to dramatically improve the quality of life for patients suffering from respiratory and infectious diseases, rare genetic disorders, and cancer. However, the quality and safety of such products are particularly critical for patients and require close scrutiny. Key product-related impurities, such as fragments and aggregates, among others, can significantly reduce the efficacy of mRNA therapies. In the present work, the possibilities offered by size exclusion chromatography (SEC) for the characterization of mRNA samples were explored using state-of-the-art ultra-wide pore columns with average pore diameters of 1000 and 2500 Å. Our investigation shows that a column with 1000 Å pores proved to be optimal for the analysis of mRNA products, whatever the size between 500 and 5000 nucleotides (nt). We also studied the influence of mobile phase composition and found that the addition of 10 mM magnesium chloride (MgCl2) can be beneficial in improving the resolution and recovery of large size variants for some mRNA samples. We demonstrate that caution should be exercised when increasing column length or decreasing the flow rate. While these adjustments slightly improve resolution, they also lead to an apparent increase in the amount of low-molecular-weight species (LMWS) and monomer peak tailing, which can be attributed to the prolonged residence time inside the column. Finally, our optimal SEC method has been successfully applied to a wide range of mRNA products, ranging from 1000 to 4500 nt in length, as well as mRNA from different suppliers and stressed/unstressed samples.


Asunto(s)
Cromatografía en Gel , ARN Mensajero , ARN Mensajero/genética , ARN Mensajero/química , Cromatografía en Gel/métodos , Humanos , Porosidad , Peso Molecular , Cloruro de Magnesio/química
2.
Anal Chem ; 96(24): 9994-10002, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38855895

RESUMEN

Therapeutic oligonucleotides (ONs) commonly incorporate phosphorothioate (PS) modifications. These introduce chiral centers and generate ON diastereomers. The increasing number of ONs undergoing clinical trials and reaching the market has led to a growing interest to better characterize the ON diastereomer composition, especially for small interfering ribonucleic acids (siRNAs). In this study, and for the first time, we identify higher-order structures as the major cause of ON diastereomer separation in hydrophilic interaction chromatography (HILIC). We have used conformational predictions and melting profiles of several representative full-length ONs to first analyze ON folding and then run mass spectrometry and HILIC to underpin the link between their folding and diastereomer separation. On top, we show how one can either enhance or suppress diastereomer separation depending on chromatographic settings, such as column temperature, pore size, stationary phase, mobile-phase ionic strength, and organic modifier. This work will significantly facilitate future HILIC-based characterization of PS-containing ONs; e.g., enabling monitoring of batch-to-batch diastereomer distributions in full-length siRNAs, a complex task that is now for the first time shown as possible on this delicate class of therapeutic double-stranded ONs.


Asunto(s)
Interacciones Hidrofóbicas e Hidrofílicas , Estereoisomerismo , Oligonucleótidos/química , Oligonucleótidos/aislamiento & purificación , ARN Interferente Pequeño/química , ARN Interferente Pequeño/aislamiento & purificación , Conformación de Ácido Nucleico , Cromatografía Liquida/métodos
3.
Anal Chem ; 95(27): 10448-10456, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37384898

RESUMEN

Ion-pairing reversed-phase liquid chromatography (IP-RPLC) is the reference separation technique for characterizing oligonucleotides (ONs) and their related impurities. The aim of this study was to better understand the retention mechanism of ONs, evaluate the applicability of the linear solvent strength (LSS) retention model, and explore the potential of ultra-short columns having a length of only 5 mm for the separation of model ONs. First, the validity of the LSS model was evaluated for ONs having sizes comprised between 3 and 30 kDa, and the accuracy of retention time predictions was assessed. It was found that ONs in IP-RPLC conditions follow an "on-off" elution behavior, despite a molecular weight lower than that of proteins. For most linear gradient separation conditions, a column length between 5 and 35 mm was found to be appropriate. Ultra-short columns of only 5 mm were therefore explored to speed up separations by considering the impact of the instrumentation on the efficiency. Interestingly, the impacts of injection volume and post-column connection tubing on peak capacity were found to be negligible. Finally, it was demonstrated that longer columns would not improve selectivity or separation efficiency, but baseline separation of three model ONs mixtures was enabled in as little as 30 s on the 5 mm column. This proof-of-concept work paves the way for future investigations using more complex therapeutic ONs and their related impurities.


Asunto(s)
Oligonucleótidos , Proteínas , Oligonucleótidos/química , Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Fase Inversa/métodos , Iones
4.
J Chromatogr A ; 1690: 463785, 2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36641941

RESUMEN

Hydrophilic interaction chromatography (HILIC) has been proposed as a valuable alternative to ion-pairing reversed-phase chromatography (IP-RPLC) for oligonucleotide (ON) analysis. In this context, the potential of seven zwitterionic HILIC columns has been evaluated against amide- and poly-hydroxy fructan-functionalized HILIC columns and a C18 column operated under IP-RPLC mode. Based on the retention characteristics of key small molecule pairs, each zwitterionic HILIC column showed a unique radar-shaped profile, suggesting different selectivities for distinct structural differences. Unmodified DNA and RNA samples were then evaluated, and the columns classified based on their retentivity. Two zwitterionic columns were particularly promising in terms of overall resolution, especially for the largest ONs (> 40-mer). Finally, separations between a chemically modified drug-like ON and its closely related impurities were performed. Although the ZIC-cHILIC column showed similar selectivity values as compared to the reference IP-RPLC technique, all columns demonstrated a general decrease in selectivity due to the minor structural differences present in the highly complex samples. This work highlights the utility of zwitterionic HILIC mode for ON analysis and it reveals the importance of understanding columns characteristics - in terms of retention and selectivity - when selecting a stationary phase for specific ON applications.


Asunto(s)
Cromatografía de Fase Inversa , Oligonucleótidos , Cromatografía Liquida/métodos , Cromatografía de Fase Inversa/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Iones/química
5.
Int J Mol Sci ; 23(20)2022 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-36293189

RESUMEN

Gene therapy is opening unprecedented opportunities for novel therapeutic approaches. Based on the concept of rescuing function mutations by co-expressing the correct gene to allow biological functions to be restored, it requires the use of viral vectors to ensure the proper delivery of therapeutic genes. In this context, recombinant adeno-associated viruses (rAAV) are the most widely used vectors. Their biomanufacturing process requires the insertion of the therapeutic gene into the rAAV (full capsids). However, a percentage of rAAV that do not contain the desired gene (empty capsids), as well as partly filled capsids, might also be produced, potentially impacting the efficiency of the therapy. Therefore, the determination of the rAAV capsids' full/empty ratio needs to be monitored to ensure consistent product quality and efficacy. Anion-exchange chromatography (AEX) can serve this need. In this contribution, thorough AEX method development, including a mobile phase, a stationary phase and gradient conditions, has highlighted its potential in supporting gene therapy. Taking advantage of the fact that viral capsids follow an "on/off" retention behavior, the application of a step gradient approach to the rAAV serotype 8 (rAAV8) allowed the unprecedented separation of rAAV8 full/empty capsids, with a resolution gain of 3.7 as compared to the resolution obtained with a fully optimized linear gradient. Finally, the developed analytical approach allowed a precise and accurate baseline separation and quantification of full and empty rAAV8 capsids, with the potential to be applied as a high-throughput quality control (QC) method.


Asunto(s)
Cápside , Dependovirus , Dependovirus/genética , Cápside/química , Terapia Genética , Vectores Genéticos/genética , Cromatografía , Aniones/análisis
6.
J Chromatogr A ; 1677: 463324, 2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-35858489

RESUMEN

As interest in oligonucleotide (ON) therapeutics is increasing, there is a need to develop suitable analytical methods able to properly analyze those molecules. However, an issue exists in the adsorption of ONs on different parts of the instrumentation during their analysis. The goal of the present paper was to comprehensively evaluate various types of bioinert materials used in ion-pairing reversed-phase (IP-RPLC) and hydrophilic interaction chromatography (HILIC) to mitigate this issue for 15- to 100-mer DNA and RNA oligonucleotides. The whole sample flow path was considered under both conditions, including chromatographic columns, ultra-high-performance liquid chromatography (UHPLC) system, and ultraviolet (UV) flow cell. It was found that a negligible amount of non-specific adsorption might be attributable to the chromatographic instrumentation. However, the flow cell of a detector should be carefully subjected to sample-based conditioning, as the material used in the UV flow cell was found to significantly impact the peak shapes of the largest ONs (60- to 100-mer). Most importantly, we found that the choice of column hardware had the most significant impact on the extent of non-specific adsorption. Depending on the material used for the column walls and frits, adsorption can be more or less pronounced. It was proved that any type of bioinert RPLC/HILIC column hardware offered some clear benefits in terms of adsorption in comparison to their stainless-steel counterparts. Finally, the evaluation of a large set of ONs was performed, including a DNA duplex and DNA or RNA ONs having different base composition, furanose sugar, and modifications occurring at the phosphate linkage or at the sugar moiety. This work represents an important advance in understanding the overall ON adsorption, and it helps to define the best combination of materials when analyzing a wide range of unmodified and modified 20-mer DNA and RNA ONs.


Asunto(s)
Oligonucleótidos , ARN , Adsorción , Cromatografía de Fase Inversa/métodos , ADN , Interacciones Hidrofóbicas e Hidrofílicas , Oligonucleótidos/análisis , Azúcares
7.
Anal Chim Acta ; 1156: 338347, 2021 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-33781463

RESUMEN

When analyzing large complex protein biopharmaceuticals, ion-pairing agents imparting low pH are widely used as mobile phase additives to improve the chromatographic performance. However, one of the most effective additives in RPLC and HILIC, trifluoroacetic acid (TFA), is known as a strong suppressor of the MS signal and limits its use in hyphenated techniques. In this study, we evaluated a wide range of acidic additives to find alternatives to TFA that provided comparable chromatographic performance and improved MS sensitivity. It was observed that stronger acidic additives were required for intact level analysis compared to subunit level analysis and that the additive nature had a larger impact on the chromatographic performance in HILIC mode compared to RPLC. Therefore, four additives were identified as valuable alternatives to TFA in RPLC mode, namely, difluoroacetic acid (DFA), dichloroacetic acid (DClAA), trichloroacetic acid (TClAA), and methanesulfonic acid (MSA). Only one of these additives provided acceptable performance in HILIC mode, namely, TClAA. After evaluation of the MS performance, TClAA was discarded due to the apparent loss of intensity in both RPLC-MS and HILIC-MS mode. Together, these results demonstrate that for HILIC-MS analysis TFA remains the gold standard additive. However, DFA was found as promising alternative to TFA for RPLC-MS analysis and could play an important role in the development of methods for the characterization of the increasingly complex protein biopharmaceuticals.


Asunto(s)
Productos Biológicos , Cromatografía Liquida , Cromatografía de Fase Inversa , Interacciones Hidrofóbicas e Hidrofílicas , Espectrometría de Masas , Proteínas , Ácido Trifluoroacético
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA