Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 13(17)2023 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-37685341

RESUMEN

Vibration-controlled transient elastography (VCTE) was the first non-invasive method used for assessing liver fibrosis in patients with chronic liver disease. Over the years, many studies have evaluated its performance. It is now used globally, and, in some countries, it represents the primary step in evaluating liver fibrosis. The aim of this study is to assess the feasibility of VCTE and highlight the prevalence of liver fibrosis stages assessed by VCTE in a large cohort of patients at a single study center. We also aimed to observe the trends in liver stiffness (LS) values over the years according to each type of hepatopathy. A retrospective study was conducted over a period of 13 years (2007-2019) and included patients who presented to our clinic for LS measurements (LSMs), either with known liver diseases or with suspected liver pathology who were undergoing fibrosis screening. The database contained a total of 23,420 measurements. Valid LSMs were obtained in 90.91% (21,291/23,420) of the cases, while 2129 (9.09%) of the measurements were either failed or unreliable. In untreated patients with chronic viral hepatitis, LS values tended to increase during the years, while in patients undergoing antiviral therapy LS values significantly decreased. Our comprehensive study, one of the largest of its kind spanning 13 years, emphasizes the reliability and significance of VCTE in real-world clinical settings.

2.
Diagnostics (Basel) ; 12(11)2022 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-36359490

RESUMEN

This is a retrospective single-center study that included 87 subjects. All subjects had chronic hepatitis B or HBV cirrhosis and underwent nucleos(t)ide analogs (NUC) treatment for more than one year. The study aimed to evaluate the dynamic changes in liver stiffness (LS) measured by transient elastography (TE) during a median interval of 64 months. Patients were assessed prior to starting therapy and followed up annually. Liver stiffness measurements (LSM) were performed annually, and ten valid LSMs were obtained in each session. Reliable LSMs were defined as the median value of 10 measurements with Interquartile range/median (IQR/M) ≤ 30%. A significant decrease in liver stiffness values (p < 0.001) was observed during follow-up. In patients with liver cirrhosis, the LSMs decreased significantly after only one year, 24.6 ± 4.3 kPa vs. 13.5 ± 4.2 kPa (p = 0.007), whereas the decrease in non-cirrhotic patients was not significant, 7.31 ± 3.62 vs. 6.80 ± 2.41 (p = 0.27). Liver stiffness decrease was more significant in patients with initially higher transaminases. Undetectable viral load was achieved in 73.5% of patients in year one, 82.7% in year two, and 90.8% in year three of treatment. In conclusion, our study reveals a decrease in liver stiffness by TE in patients with chronic hepatitis B when undergoing anti-HBV therapy in the first two years. It can be used as a method for follow-up in patients undergoing NUC therapy.

3.
Med Ultrason ; 23(1): 7-14, 2021 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-33220028

RESUMEN

AIM: Nonalcoholic Fatty Liver Disease (NAFLD) is increasing in frequency in daily practice and evaluation of liver steatosis, fibrosis and inflammation severity are essential for prognosis assessment. The aim was to evaluate the usefulnessof a new liver steatosis quantification system - Ultrasound-Guided Attenuation Parameter (UGAP) from General Electric Healthcare, using Controlled Attenuation Parameter (CAP) as the reference method. MATERIAL AND METHOD: 179 consecutive subjects, in whom liver steatosis was assessed in the same session using UGAP, implemented on LOGIQ E10 system (GE Healthcare), and CAP (FibroScan, EchoSens). To discriminate between steatosis stages by CAP, we used the cut-offs recommended by the manufacturer: S1 (mild) - 230 dB/m, S2 (moderate) - 275 dB/m, S3 (severe) - 300 dB/m. RESULTS: We classified our cohort by means of CAP into the following groups: S0 (no steatosis): 48/176 (27.2%), S1 (mild): 56/176 (31.6%), S2 (moderate): 14/176 (7.3%) and S3 (severe): 59/176 (33.9%). The mean UGAP values increased with the steatosis grade and for each group were the following: S0: 198.3±25.7 dB/m, S1: 216.86±26.3 dB/m, S2: 237.79±26.3 dB/m, and S3: 270.8±31.62 dB/m respectively (p<0.001). A very good positive correlation was found between UGAP and CAP values (r=0.73, p<0.0001). The best cut-off values for predicting different grades of liver steatosis using CAP as the reference were: S1 - 192.5 dB/m (AUC 0.83); S2 - 231 dB/m (AUC 0.90) and S3 - 248 dB/m (AUC 0.91). CONCLUSION: UGAP seems to be a good method for liver steatosis quantification and correlates strongly with CAP values.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Enfermedad del Hígado Graso no Alcohólico , Biopsia , Humanos , Hígado/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Valor Predictivo de las Pruebas , Curva ROC , Ultrasonografía Intervencional
4.
Med Ultrason ; 22(3): 265-271, 2020 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-32399537

RESUMEN

AIM: The study compared the usefulness of 2D-SWE and attenuation measurements obtained using Aplio i800 from Canon together with Transient Elastography (TE) and the Controlled Attenuation Parameter (CAP) as the reference method. MATERIAL AND METHODS: We included 112 consecutive adults with reliable LS measurements, 44 healthy subjects and 68 subjects with chronic hepatopathies in whom liver stiffness (LS) and steatosis were evaluated in the same session employing two elastography techniques: Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) implemented on the FibroScan® 530 Compact system and Two Dimensional Shear Wave Elastography (2D-SWE) with Attenuation Imaging (ATI) installed on the Aplio i800 series ultrasound system. Reliable measurements were defined as the median value of 10, respectively 5 valid LS measurements for TE and 2D-SWE, with an interquartile range interval/median ratio (IQR/M) <30%. RESULTS: A very strong positive correlation was found between LS values obtained by TE and 2D-SWE: r=0.88, p<0.0001 and between the attenuation coefficients of steatosis obtained by CAP and ATI, r=0.81, p<0.0001. The best cut-off values by 2DSWE for predicting different stages of liver fibrosis were: for F≥2 - 7.9 kPa and F=4 - 11.7 kPa. Regarding steatosis, the best ATI cut-off values were: for S≥1 - 0.79 dB/cm/mHz and for S3 - 0.86 dB/cm/mHz. CONCLUSION: 2D-SWE and ATI measurements with the new system strongly correlated with TE and CAP results.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/métodos , Hígado Graso/complicaciones , Hígado Graso/diagnóstico por imagen , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA