Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
J Vasc Interv Radiol ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38599280

RESUMEN

PURPOSE: To evaluate the performance of a prototype flexible transbronchial cryoprobe compared with that of percutaneous transthoracic cryoablation and to define cone-beam computed tomography (CT) imaging and pathology cryolesion features in an in vivo swine model. MATERIALS AND METHODS: Transbronchial cryoablation was performed with a prototype flexible cryoprobe (3 central and 3 peripheral lung ablations in 3 swine) and compared with transthoracic cryoablation performed with a commercially available rigid cryoprobe (2 peripheral lung ablations in 1 swine). Procedural time and cryoablation success rates for endobronchial navigation and cryoneedle deployment were measured. Intraoperative cone-beam CT imaging features of cryolesions were characterized and correlated with gross pathology and hematoxylin and eosin-stained sections of the explanted cryolesions. RESULTS: The flexible cryoprobe was successfully navigated and delivered to each target through a steerable guiding sheath (6/6). At 4 minutes after ablation, 5 of 6 transbronchial and 2 of 2 transthoracic cryolesions were visible on cone-beam CT. The volumes on cone-beam CT images were 55.5 cm3 (SE ± 8.0) for central transbronchial ablations (n = 2), 72.5 cm3 (SE ± 8.1) for peripheral transbronchial ablations (n = 3), and 79.5 cm3 (SE ±11.6) for peripheral transthoracic ablations (n = 2). Pneumothorax developed in 1 animal after transbronchial ablation and during ablation in the transthoracic cryoablation. Images of cryoablation zones on cone-beam CT correlated well with the matched gross pathology and histopathology sections of the cryolesions. CONCLUSIONS: Transbronchial cryoablation with a flexible cryoprobe, delivered through a steerable guiding sheath, is feasible. Transbronchial cryoablation zones are imageable with cone-beam CT, with gross pathology and histopathology similar to those of transthoracic cryoablation.

2.
Pharm Res ; 41(1): 165-183, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37936014

RESUMEN

PURPOSE: To evaluate the use of resonant acoustic mixing (RAM) technology for homogenous blending of a morphologically challenging model API in low-dose concentrations (<0.1% w/w), and assess the potential for blend uniformity (BU) optimization. METHODS: Caffeine (CAF) mixing was carried out using a LabRAM I benchtop mixer. Uniformity was assessed under a range of mixing conditions and sample preparation procedures in order to optimize system performance. The capacity for microscale mixing was evaluated from final parameters for 0.05% and 0.0125% CAF blends. RESULTS: Upon optimization, RAM was able to accurately prepare homogeneous mixtures of <0.1% CAF in dilutions of up to 1 part per 8,000. Results from a 0.05% blend targeting 125 µg CAF dosage amounts revealed an AV score of 8.8 while a 0.0125% w/w blend accurately prepared 25 µg of CAF with 99.3% accuracy (98.7% label claim) and AV of 10.1. Microscale mixing in the 0.05% w/w blend was confirmed from plots of BU data against sample size demonstrating a slope of 0.05 within the range of 250-10 mg sample (125-5 µg CAF). L1 BU criteria only failed at the level of 2 µg CAF, despite target precision to 26 nanograms (98.7% label claim). CONCLUSIONS: This study presents the first instance of a homogenously mixed <0.1% (w/w) blend using RAM technology and demonstrate the suitability for reproducible dosing of single-digit microgram drug amounts. Uniformity is documented for API amounts 60x smaller than a recent report has shown and 10,000x smaller than achieved previously with CAF.


Asunto(s)
Tecnología Farmacéutica , Tecnología , Polvos , Tecnología Farmacéutica/métodos , Acústica , Tamaño de la Partícula
3.
J Hepatocell Carcinoma ; 10: 1973-1990, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37954494

RESUMEN

Objectives: Local and systemic immune responses evoked by locoregional therapies such as cryoablation are incompletely understood. The aim of this study was to characterize cryoablation-related immune response and the capacity of immune drugs to augment immunity upon cryoablation for the treatment of hepatocellular carcinoma (HCC) using a woodchuck hepatocellular carcinoma model. Materials and Methods: Twelve woodchucks chronically infected with woodchuck hepatitis virus and with hepatocellular carcinoma underwent imaging with contrast-enhanced CT. Partial cryoablation of tumors in three woodchucks was performed. Fourteen days after cryoablation, liver tissues were harvested and stained with H&E and TUNEL, and immune infiltrates were quantified. Peripheral blood mononuclear cells (PBMC) were collected from ablated and nonablated woodchucks, labeled with carboxyfluorescein succinimidyl ester (CFSE) and cultured with immune-modulating drugs, including a small PD-L1 antagonist molecule (BMS-202) and three TLR7/8 agonists (DSR 6434, GS-9620, gardiquimod). After incubation, cell replication and immune cell populations were analyzed by flow cytometry. Results: Local immune response in tumors was characterized by an increased number of CD3+ T lymphocytes and natural killer cells in the cryolesion margin compared to other tumor regions. T regulatory cells were found in higher numbers in distant tumors within the liver compared to untreated or control tumors. Cryoablation also augmented the systemic immune response as demonstrated by higher numbers of PBMC responses upon immune drug stimulation in the cryoablation group. Conclusions: Partial cryoablation augmented immune effects in both treated and remote untreated tumor microenvironments, as well as systemically, in woodchucks with HCC. Characterization of these mechanisms may enhance development of novel drug-device combinations for treatment of HCC.

5.
Biomolecules ; 12(12)2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36551153

RESUMEN

Sclerotherapy is among the least invasive and most commonly utilised treatment options for varicose veins. Nonetheless, it does not cure varicosities permanently and recurrence rates are of up to 64%. Although sclerosing foams have been extensively characterised with respect to their bench-top properties, such as bubble size distribution and half-life, little is known about their flow behaviour within the venous environment during treatment. Additionally, current methods of foam characterisation do not recapitulate the end-point administration conditions, hindering optimisation of therapeutic efficacy. Here, a therapeutically relevant apparatus has been used to obtain a clinically relevant rheological model of sclerosing foams. This model was then correlated with a therapeutically applicable parameter-i.e., the capability of foams to displace blood within a vein. A pipe viscometry apparatus was employed to obtain a rheological model of 1% polidocanol foams across shear rates of 6 s-1 to 400 s-1. Two different foam formulation techniques (double syringe system and Tessari) and three liquid-to-gas ratios (1:3, 1:4 and 1:5) were investigated. A power-law model was employed on the rheological data to obtain the apparent viscosity of foams. In a separate experiment, a finite volume of foam was injected into a PTFE tube to displace a blood surrogate solution (0.2% w/v carboxymethyl cellulose). The displaced blood surrogate was collected, weighed, and correlated with foam's apparent viscosity. Results showed a decreasing displacement efficacy with foam dryness and injection flowrate. Furthermore, an asymptotic model was formulated that may be used to predict the extent of blood displacement for a given foam formulation and volume. The developed model could guide clinicians in their selection of a foam formulation that exhibits the greatest blood displacement efficacy.


Asunto(s)
Soluciones Esclerosantes , Várices , Humanos , Soluciones Esclerosantes/uso terapéutico , Várices/tratamiento farmacológico , Polidocanol , Escleroterapia/métodos , Reología
6.
Sci Rep ; 12(1): 21886, 2022 12 19.
Artículo en Inglés | MEDLINE | ID: mdl-36535979

RESUMEN

Hepatocellular carcinoma (HCC) is an aggressive liver cancer with limited effective treatment options. In this study, we selected TLR agonists imiquimod (IMQ), gardiquimod (GARD), GS-9620 and DSR 6434, and a small molecule checkpoint inhibitor, BMS-202, for characterization of drug loading and release from radiopaque embolic beads (DC Bead LUMI) for potential use in image-guided transarterial embolization (TACE) of HCC. The maximum drug loading capacity and amount of drug released over time were determined by high performance liquid chromatography and compared with the commonly used anthracycline, doxorubicin hydrochloride (Dox). Maximum drug loading was 204.54 ± 3.87, 65.28 ± 3.09, 65.95 ± 6.96, 65.97 ± 1.54, and 148.05 ± 2.24 mg of drug per milliliter of DC Bead LUMI for Dox, GARD, DSR 6434, IMQ, and BMS-202, respectively. Fast loading and subsequent rapid release in saline were observed for IMQ, GARD, and DSR 6434. These drugs could also be partially removed from the beads by repeated washing with de-ionized water suggesting weak interaction with the beads. Aggregation of IMQ was observed in water and saline. GS-9620 partially decomposed in the solubilizing solution, so loading and release were not characterized. Compared to TLR agonists, slower loading and release were observed for Dox and BMS-202. Potential factors influencing drug loading into and release from DC Bead LUMI including steric hinderance, hydrophobicity, drug pKa, and the electrostatic nature of the beads are discussed. The maximum loading capacity of BMS-202 and Dox in DC Bead LUMI exceeded the maximum theoretical loading capacity of the beads expected from ionic interaction alone suggesting additional drug-bead or drug-drug interactions may play a role. Slightly more release was observed for BMS-202 at early time points followed by a slower release compared to Dox. Further study of these drug-bead combinations is warranted in search of new tools for locoregional delivery of immune-modulating agents for treatment of HCC via drug-eluting bead chemoembolization.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Quimioembolización Terapéutica/métodos , Doxorrubicina/química , Antibióticos Antineoplásicos/química , Microesferas
7.
J Vasc Interv Radiol ; 33(9): 1034-1044.e29, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35526675

RESUMEN

PURPOSE: To assess the safety and tolerability of a vandetanib-eluting radiopaque embolic (BTG-002814) for transarterial chemoembolization (TACE) in patients with resectable liver malignancies. MATERIALS AND METHODS: The VEROnA clinical trial was a first-in-human, phase 0, single-arm, window-of-opportunity study. Eligible patients were aged ≥18 years and had resectable hepatocellular carcinoma (HCC) (Child-Pugh A) or metastatic colorectal cancer (mCRC). Patients received 1 mL of BTG-002814 transarterially (containing 100 mg of vandetanib) 7-21 days prior to surgery. The primary objectives were to establish the safety and tolerability of BTG-002814 and determine the concentrations of vandetanib and the N-desmethyl vandetanib metabolite in the plasma and resected liver after treatment. Biomarker studies included circulating proangiogenic factors, perfusion computed tomography, and dynamic contrast-enhanced magnetic resonance imaging. RESULTS: Eight patients were enrolled: 2 with HCC and 6 with mCRC. There was 1 grade 3 adverse event (AE) before surgery and 18 after surgery; 6 AEs were deemed to be related to BTG-002814. Surgical resection was not delayed. Vandetanib was present in the plasma of all patients 12 days after treatment, with a mean maximum concentration of 24.3 ng/mL (standard deviation ± 13.94 ng/mL), and in resected liver tissue up to 32 days after treatment (441-404,000 ng/g). The median percentage of tumor necrosis was 92.5% (range, 5%-100%). There were no significant changes in perfusion imaging parameters after TACE. CONCLUSIONS: BTG-002814 has an acceptable safety profile in patients before surgery. The presence of vandetanib in the tumor specimens up to 32 days after treatment suggests sustained anticancer activity, while the low vandetanib levels in the plasma suggest minimal release into the systemic circulation. Further evaluation of this TACE combination is warranted in dose-finding and efficacy studies.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Adolescente , Adulto , Carcinoma Hepatocelular/tratamiento farmacológico , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/efectos adversos , Quimioembolización Terapéutica/métodos , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/terapia , Piperidinas , Inhibidores de Proteínas Quinasas/efectos adversos , Quinazolinas/efectos adversos , Resultado del Tratamiento
8.
Invest Radiol ; 57(8): 495-501, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35239613

RESUMEN

OBJECTIVES: The aims of this study were to develop a model to estimate drug dose delivered to tumors after transarterial chemoembolization (TACE) with radiopaque drug-eluting beads (DEBs) based on DEB density on cone-beam computed tomography (CT) and to evaluate drug penetration into tissue in a woodchuck hepatoma model. MATERIALS AND METHODS: Transarterial chemoembolization was performed in woodchucks with hepatocellular carcinoma (N = 5) using DEBs (70-150 µm, LC Bead LUMI) loaded with doxorubicin. Livers were resected 45 minutes after embolization, immediately frozen, and cut using liver-specific, 3D-printed sectioning molds. Doxorubicin levels in tumor specimens were measured by high-performance liquid chromatography and correlated with DEB iodine content that was measured using prototype cone-beam CT-based embolization treatment planning software. Doxorubicin penetration into tissue surrounding DEBs was assessed by fluorescence microscopy of tumor sections. Fluorescence intensity was converted into doxorubicin concentration using calibration standards. Intensity-thresholded color heatmaps were generated representing extravascular drug penetration. RESULTS: Consistent segmentation of DEBs on cone-beam CT was achieved using a semiautomated intensity thresholding method. A positive linear correlation (0.96) was found between DEB iodine content measured on cone-beam CT and the amount of doxorubicin measured in tumor specimens. Prediction of doxorubicin levels in tumor sections that were not included in model development was accurate, with a root-mean-square error of 0.08 mg of doxorubicin. Tumor penetration of eluted doxorubicin resulted in concentration gradients where drug content decreased with increasing distance from blood vessels containing DEBs. Drug penetration was greater for blood vessels containing DEB clusters compared with single DEB, with higher doxorubicin concentrations extending further away from the vessels. CONCLUSIONS: Estimation of drug dose delivered during transarterial chemoembolization in a woodchuck hepatocellular carcinoma model was possible using DEB radiopacity on cone-beam CT as a surrogate marker. Doxorubicin penetration was greatest adjacent to vessels containing DEB clusters compared with single DEB. Intraprocedural estimation of the spatial distribution of drug dose within the tumor could enable real-time adjustments to DEB delivery, to maximize treatment coverage or identify regions of tumor at risk for undertreatment.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Yodo , Neoplasias Hepáticas , Animales , Antibióticos Antineoplásicos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Tomografía Computarizada de Haz Cónico/métodos , Doxorrubicina , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/terapia , Marmota , Resultado del Tratamiento
9.
Int J Pharm ; 616: 121466, 2022 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-35065205

RESUMEN

Cancer immunotherapy has yet to reach its full potential due in part to limited response rates and side effects inherent to systemic delivery of immune-modulating drugs. Local administration of immunotherapy using drug-eluting embolic (DEE) microspheres as drug delivery vehicles for direct infusion into tumor-feeding arteries might increase and prolong tumor drug concentrations and reduce systemic drug exposure, potentially improving the risk-to-benefit ratio of these agents. The purpose of this study was to evaluate the ability of four immune modulators affecting two different immune pathways to potentiate replication of immune cells from a woodchuck model of hepatocellular carcinoma. DSR 6434, a Toll-like receptor agonist, and BMS-202, a PD-L1 checkpoint inhibitor, induced immune cell replication and were successfully loaded into radiopaque DEE microspheres in high concentrations. Release of DSR 6434 from the DEE microspheres was rapid (t99% = 0.4 h) upon submersion in a physiologic saline solution while BMS-202 demonstrated a more sustained release profile (t99% = 17.9 h). These findings demonstrate the feasibility of controlled delivery of immune-modulating drugs via a local DEE microsphere delivery paradigm.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/patología , Quimioembolización Terapéutica/efectos adversos , Doxorrubicina , Humanos , Neoplasias Hepáticas/patología , Microesferas , Preparaciones Farmacéuticas
10.
Drug Deliv Transl Res ; 12(1): 1-6, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34024013

RESUMEN

Achieving efficacious systemic levels of orally administered peptides is incredibly challenging due to the significant barriers to their bioavailability-their stability in the gastrointestinal tract and challenge of transepithelial transit, and variable pharmacokinetics. Even so, as the generally preferred route of administration, significant research effort in academic and industrial settings has focused on enabling the systemic absorption of orally delivered peptides. Despite several decades of research, few have ever reached the market. The recent approval of Rybelsus® (oral semaglutide) by the FDA [1], the EMA [2], and the Pmda [3] represents a significant landmark in the delivery of therapeutic peptides and is the culmination of more than 30 years research and development of the drug delivery technology enabling the product-Emisphere's Eligen™ technology-and an outstanding commitment to scientific, technical, and clinical innovation by Novo Nordisk. Following years of fundamental and applied research, an innovative clinical strategy led to the aptly named PIONEER clinical programme. This included ten Phase 3 clinical trials that demonstrated the tablet formulation to be as effective as the already approved injectable form of the drug, and more effective than competitor products in terms of its blood glucose lowering effects and weight loss. Not only is this a potentially life changing medicine for diabetic patients, it holds tremendous commercial potential for Novo Nordisk, with some analysts predicting the product to reach $5 billion in peak revenues [3]. In this "Inspirational Note," we summarize some of the public domain work that led to the achievement of this significant milestone and provide commentary on its potential future impact.


Asunto(s)
Diabetes Mellitus Tipo 2 , Administración Oral , Glucemia , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Péptidos Similares al Glucagón/farmacocinética , Péptidos Similares al Glucagón/uso terapéutico , Humanos , Hipoglucemiantes , Péptidos
11.
Br J Radiol ; 95(1130): 20210594, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34762499

RESUMEN

OBJECTIVE: To determine the feasibility of using radiopaque (RO) beads as direct tumour surrogates for image-guided radiotherapy (IGRT) in patients with liver tumours after transarterial chemoembolisation (TACE). METHODS: A novel vandetanib-eluting RO bead was delivered via TACE as part of a first-in-human clinical trial in patients with either hepatocellular carcinoma or liver metastases from colorectal cancer. Following TACE, patients underwent simulated radiotherapy imaging with four-dimensional computed tomography (4D-CT) and cone-beam CT (CBCT) imaging. RO beads were contoured using automated thresholding, and feasibility of matching between the simulated radiotherapy planning dataset (AVE-IP image from 4D data) and CBCT scans assessed. Additional kV, MV, helical CT and CBCT images of RO beads were obtained using an in-house phantom. Stability of RO bead position was assessed by comparing 4D-CT imaging to CT scans taken 6-20 days following TACE. RESULTS: Eight patients were treated and 4D-CT and CBCT images acquired. RO beads were visible on 4D-CT and CBCT images in all cases and matching successfully performed. Differences in centre of mass of RO beads between CBCT and simulated radiotherapy planning scans (AVE-IP dataset) were 2.0 mm mediolaterally, 1.7 mm anteroposteriorally and 3.5 mm craniocaudally. RO beads in the phantom were visible on all imaging modalities assessed. RO bead position remained stable up to 29 days post TACE. CONCLUSION: RO beads are visible on IGRT imaging modalities, showing minimal artefact. They can be used for on-set matching with CBCT and remain stable over time. ADVANCES IN KNOWLEDGE: The role of RO beads as fiducial markers for stereotactic liver radiotherapy is feasible and warrants further exploration as a combination therapy approach.


Asunto(s)
Carcinoma Hepatocelular/radioterapia , Embolización Terapéutica/métodos , Marcadores Fiduciales , Neoplasias Hepáticas/radioterapia , Radiocirugia/métodos , Radioterapia Guiada por Imagen/métodos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Neoplasias Colorrectales/patología , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Tomografía Computarizada Cuatridimensional , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/terapia , Microesferas , Fantasmas de Imagen , Proyectos Piloto
12.
Anticancer Drugs ; 32(9): 897-908, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33929994

RESUMEN

Vandetanib-eluting radiopaque beads (VERB) have been developed for use in transarterial chemoembolization of liver tumours, with the goal of combining embolization with local delivery of antiangiogenic therapy. The objective of this study was to investigate how embolization-induced hypoxia may affect antitumoural activity of vandetanib, an inhibitor of vascular endothelial growth factor receptor (VEGFR) and epidermal growth factor receptor (EGFR), in the context of hepatocellular carcinoma (HCC) treatment. We studied the effect of vandetanib on proliferation, cell cycle and apoptosis of HCC cells, in hypoxic conditions, as well as the direct effects of the beads on 3D HCC spheroids. Vandetanib suppressed proliferation and induced apoptosis of HCC cells in vitro and was equipotent in hypoxic and normoxic conditions. High degrees of apoptosis were observed among cell lines in which vandetanib suppressed ERK1/2 phosphorylation and upregulated the proapoptotic protein Bim, but this did not appear essential for vandetanib-induced cell death in all cell lines. Vandetanib also suppressed the hypoxia-induced secretion of VEGF from HCC cells and inhibited proliferation of endothelial cells. Incubation of tumour spheroids with VERB led to sustained growth inhibition equivalent to the effect of free drug. We conclude that vandetanib has both antiangiogenic and direct anticancer activity against HCC cells even in hypoxic conditions, warranting the further evaluation of VERB as novel anticancer agents.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Hipoxia/inducido químicamente , Neoplasias Hepáticas/terapia , Piperidinas/farmacología , Quinazolinas/farmacología , Apoptosis/efectos de los fármacos , Ciclo Celular/efectos de los fármacos , Línea Celular Tumoral , Liberación de Fármacos , Células Endoteliales de la Vena Umbilical Humana , Humanos , Sistema de Señalización de MAP Quinasas/efectos de los fármacos , Neovascularización Patológica/tratamiento farmacológico , Factores de Crecimiento Endotelial Vascular/antagonistas & inhibidores
13.
J Hepatocell Carcinoma ; 8: 71-83, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33728278

RESUMEN

BACKGROUND: Woodchucks chronically infected with woodchuck hepatitis virus (WHV), which resembles human hepatitis B virus, develop spontaneous hepatic tumors and may be an important biological and immunological model for human HCC. Nonetheless, this model requires further validation to fully realize its translational potential. METHODS: Woodchucks infected at birth with WHV that had developed HCC (n=12) were studied. Computed tomography, ultrasound, and magnetic resonance imaging were performed under anesthesia. LI-RADS scoring and correlative histologic analysis of sectioned tissues were performed. For immune characterization of tumors, CD3 (T cells), CD4 (T helpers), NCAM (Natural killers), FOXP3 (T-regulatory), PDL-1 (inhibitory checkpoint protein), and the human hepatocellular carcinoma (HCC) biomarker alpha-fetoprotein (AFP) immunohistochemical stains were performed. RESULTS: Forty tumors were identified on imaging of which 29 were confirmed to be HCC with 26 categorized as LR-4 or 5. The remainder of the tumors had benign histology including basophilic foci, adenoma, and lipidosis as well as pre-malignant dysplastic foci. LR-4 and LR-5 lesions showed high sensitivity (90%) and specificity (100%) for malignant and pre-malignant tumors. Natural killers count was found to be 2-5 times lower in tumors relative to normal parenchyma while other immune cells were located in the periphery of tumors. Tumors expressed AFP and did not express PD-L1. CONCLUSION: Woodchucks chronically infected with WHV developed diverse hepatic tumor types with diagnostic imaging, pathology, and immune patterns comparable to that in humans. This unique animal model may provide a valuable tool for translation and validation of novel image-guided and immune-therapeutic investigations.

14.
Eur J Pharm Sci ; 160: 105772, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33621612

RESUMEN

Understanding the intra-tumoral distribution of chemotherapeutic drugs is extremely important in predicting therapeutic outcome. Tissue mimicking gel phantoms are useful for studying drug distribution in vitro but quantifying distribution is laborious due to the need to section phantoms over the relevant time course and individually quantify drug elution. In this study we compare a bespoke version of the traditional phantom sectioning approach, with a novel confocal microscopy technique that enables dynamic in situ measurements of drug concentration. Release of doxorubicin from Drug-eluting Embolization Beads (DEBs) was measured in phantoms composed of alginate and agarose over comparable time intervals. Drug release from several different types of bead were measured. The non-radiopaque DC Bead™ generated a higher concentration at the boundary between the beads and the phantom and larger drug penetration distance within the release period, compared with the radiopaque DC Bead LUMI™. This is likely due to the difference of compositional and structural characteristics of the hydrogel beads interacting differently with the loaded drug. Comparison of in vitro results against historical in vivo data show good agreement in terms of drug penetration, when confounding factors such as geometry, elimination and bead chemistry were accounted for. Hence these methods have demonstrated potential for both bead and gel phantom validation, and provide opportunities for optimisation of bead design and embolization protocols through in vitro-in vivo comparison.


Asunto(s)
Quimioembolización Terapéutica , Portadores de Fármacos , Doxorrubicina , Liberación de Fármacos , Microesferas
15.
Expert Opin Drug Deliv ; 18(3): 383-398, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33480306

RESUMEN

INTRODUCTION: Drug-eluting embolic (DEE) microspheres, or drug-eluting beads (DEB), delivered by transarterial chemoembolization (TACE) serve as a therapeutic embolic to stop blood flow to tumors and a drug delivery vehicle. New combinations of drugs and DEE microspheres may exploit the potential synergy between mechanisms of drug activity and local tissue responses generated by TACE to enhance the efficacy of this mainstay therapy. AREAS COVERED: This review provides an overview of key drug delivery concepts related to DEE microspheres with a focus on recent technological developments and promising emerging clinical applications as well as speculation into the future. EXPERT OPINION: TACE has been performed for nearly four decades by injecting chemotherapy drugs into the arterial supply of tumors while simultaneously cutting off their blood supply, trying to starve and kill cancer cells, with varying degrees of success. The practice has evolved over the decades but has yet to fulfill the promise of truly personalized therapies envisioned through rational selection of drugs and real-time multi-parametric image guidance to target tumor clonality or heterogeneity. Recent technologic and pharmacologic developments have opened the door for potentially groundbreaking advances in how TACE with DEE microspheres is performed with the goal of achieving advancements that benefit patients.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Preparaciones Farmacéuticas , Carcinoma Hepatocelular/terapia , Doxorrubicina , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Microesferas , Estudios Retrospectivos , Resultado del Tratamiento
16.
Sci Rep ; 11(1): 533, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-33436734

RESUMEN

Current therapy for hypervascular cancers, e.g., hepatocellular carcinoma, includes occlusion of the tumor blood supply by arterial infusion of embolic microspheres (beads) suspended in iodine-based contrast under fluoroscopic guidance. Available radiopaque, imageable beads use iodine as the radiopacifier and cannot be differentiated from contrast. This study aimed to synthesize and characterize imageable beads using bismuth as the radiopacifier that could be distinguished from iodine contrast based upon the difference in the binding energy of k-shell electrons (k-edge). Radiodense bismuth beads were successfully synthesized some with uniform bismuth distribution across the beads. The beads were spherical and could be infused through clinical microcatheters. The bismuth beads could be imaged with clinical dual-energy computed tomography (CT), where iodine-based contrast could be distinguished from the microspheres. The ability to separate iodine from bismuth may enhance the diagnostic information acquired on follow-up CT, identifying the distribution of the embolic beads separately from the contrast. Furthermore, with sequential use of iodine- and bismuth-based beads, the two radiopaque beads could be spatially distinguished on imaging, which may enable the development of dual drug delivery and dual tracking.


Asunto(s)
Bismuto/química , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Medios de Contraste/síntesis química , Embolización Terapéutica/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Microesferas , Tomografía Computarizada por Rayos X/métodos , Carcinoma Hepatocelular/irrigación sanguínea , Medios de Contraste/química , Yodo/química , Neoplasias Hepáticas/irrigación sanguínea
17.
J Biomed Mater Res B Appl Biomater ; 109(1): 69-91, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32621565

RESUMEN

Varicose veins are chronic venous defects that affect >20% of the population in developed countries. Among potential treatments, sclerotherapy is one of the most commonly used. It involves endovenous injection of a surfactant solution (or foam) in varicose veins, inducing damage to the endothelial layer and subsequent vessel sclerosis. Treatments have proven to be effective in the short-term, however recurrence is reported at rates of up to 64% 5-year post-treatment. Thus, once diagnosed with varicosities there is a high probability of a permanently reduced quality of life. Recently, foam sclerotherapy has become increasingly popular over its liquid counterpart, since foams can treat larger and longer varicosities more effectively, they can be imaged using ultrasound, and require lower amounts of sclerosing agent. In order to minimize recurrence rates however, an investigation of current treatment methods should lead to more effective and long-lasting effects. The literature is populated with studies aimed at characterizing the fundamental physics of aqueous foams; nevertheless, there is a significant need for appropriate product development platforms. Despite successfully capturing the microstructural evolution of aqueous foams, the complexity of current models renders them inadequate for pharmaceutical development. This review article will focus on the physics of foams and the attempts at optimizing them for sclerotherapy. This takes the form of a discussion of the most recent numerical and experimental models, as well as an overview of clinically relevant parameters. This holistic approach could contribute to better foam characterization methods that patients may eventually derive long term benefit from.


Asunto(s)
Soluciones Esclerosantes/farmacología , Escleroterapia/métodos , Várices/terapia , Formas de Dosificación , Humanos , Polidocanol/química , Reología , Escleroterapia/efectos adversos , Soluciones , Agua
18.
J Mater Chem B ; 8(36): 8207-8218, 2020 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-32813005

RESUMEN

Liquid formulations have a well-established role in therapeutic embolisation of blood vessels with the widespread use of cyanoacrylate glues, precipitating polymer suspensions, sclerosing agents and viscous emulsions of oil and chemotherapeutic agents. There is currently an emerging market for next generation liquid embolics which aim to address some of the short-comings of the currently used products. These next generation systems use varying chemistries in their approach to formulate new systems including polymerising, precipitating and phase-transitioning mechanisms to form solidified masses in situ within the vasculature. Some of these emerging technologies have been developed to possess improved imaging properties such as inherent radiopacity, rather than relying on having to mixing with radiopaque materials such as tantalum powder and reduction of X-ray imaging artefacts (streaking). Others offer solvent-free formulations which gel on contact with blood thereby allowing precise control over gel formation during the embolisation process without the use of potentially toxic solvents. In this review, we discuss the role of liquid agents in therapeutic embolisation and the potential of emerging technologies under development for use in the next generation of embolics.


Asunto(s)
Embolización Terapéutica/métodos , Geles/uso terapéutico , Polímeros/uso terapéutico , Animales , Precipitación Química , Embolización Terapéutica/instrumentación , Geles/síntesis química , Humanos , Transición de Fase , Polimerizacion , Polímeros/síntesis química
19.
Cardiovasc Intervent Radiol ; 43(12): 1918-1924, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32803282

RESUMEN

PURPOSE: Topotecan is a camptothecin analogue with potential advantages over irinotecan for transarterial chemoembolization (TACE) of hepatic colorectal metastases including greater anti-neoplastic activity without enzymatic activation. The purpose of this study was to assess safety and tolerability of topotecan-loaded radiopaque microspheres (ROMTOP) administered by TACE in a rabbit model and to compare the in vitro elution of topotecan from microspheres to irinotecan. MATERIALS AND METHODS: Topotecan was loaded into radiopaque microspheres (70-150 µm, DC Bead LUMI™, Biocompatibles UK Ltd-Boston Scientific Corporation) to the maximum capacity of 80 mg/mL of microspheres. Six healthy New Zealand White rabbits underwent hepatic TACE with ROMTOP under fluoroscopic guidance until angiographic stasis. Assessment of toxicities included regular liver function tests and complete blood counts until euthanasia 28 days post-TACE. In vitro topotecan elution from the microspheres was assessed using an open-loop flow-through system and compared to irinotecan. RESULTS: The mean bead volume and topotecan dose delivered were 0.086 mL (0.076-0.105 mL) and 1.99 mg/kg (1.51-2.55 mg/kg), respectively. Aspartate aminotransferase and alanine aminotransferase were elevated post-embolization but resolved within 2 weeks. One rabbit died two days after TACE with pyloric duodenal perforation observed at necropsy, potentially due to non-target embolization. In vitro elution of topotecan from ROMTOP was complete in 10 h compared to 3 h for irinotecan-loaded microspheres. CONCLUSION: Selective embolization with ROMTOP was tolerated at a dose of 2 mg/kg (24 mg/m2) in rabbits. In vitro topotecan elution from microspheres was more prolonged compared to irinotecan.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas Experimentales/terapia , Topotecan/farmacología , Animales , Carcinoma Hepatocelular/diagnóstico , Humanos , Irinotecán , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas Experimentales/diagnóstico , Microesferas , Conejos , Inhibidores de Topoisomerasa I/farmacología
20.
J Biomed Mater Res B Appl Biomater ; 108(7): 2878-2888, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32578348

RESUMEN

The in vitro and in vivo handling and performance characteristics of a small caliber radiopaque embolic microsphere, 40-90 µm DC Bead LUMI™ (LUMI40-90), were studied. Microsphere drug loading and elution and effects on size, suspension, and microcatheter delivery were evaluated using established in vitro methodologies. In vivo evaluations of vascular penetration (rabbit renal artery embolization), long-term biocompatibility and X-ray imaging properties, pharmacokinetics and local tissue effects of both doxorubicin (Dox) and irinotecan (Iri) loaded microspheres (swine hepatic artery embolization) were conducted. Compared to 70-150 µm DC Bead LUMI (LUMI70-150), LUMI40-90 averaged 70 µm versus 100 µm, which was unchanged upon drug loading. Handling, suspension, and microsphere delivery studies were successfully performed. Dox loading was faster (20 min) and Iri equivalent (<10 min) while drug elution rates were similar. Contrast suspension times were longer with no delivery complications. Vascular penetration was statistically greater (rabbit) with no unexpected adverse safety findings (swine). Microspheres ± drug were visible under X-ray imaging (CT) at 90 days. Peak plasma drug levels and area under the curve were greater for LUMI40-90 compared to LUMI70-150 but comparable to 70-150 µm DC BeadM1™ (DC70-150). Local tissue effects showed extensive hepatic necrosis for Dox, whereas Iri displayed lower toxicity with more pronounced lobar fibrosis. LUMI40-90 remains suspended for longer and have greater vessel penetration compared to the other DC Bead LUMI sizes and are similarly highly biocompatible with long-term visibility under X-ray imaging. Drug loading is equivalent or faster with pharmacokinetics similar to DC70-150 for both Dox and Iri.


Asunto(s)
Medios de Contraste , Doxorrubicina , Portadores de Fármacos , Embolización Terapéutica , Irinotecán , Microesferas , Tomografía Computarizada por Rayos X , Animales , Medios de Contraste/química , Medios de Contraste/farmacocinética , Medios de Contraste/farmacología , Doxorrubicina/química , Doxorrubicina/farmacocinética , Doxorrubicina/farmacología , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Portadores de Fármacos/farmacología , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/metabolismo , Irinotecán/química , Irinotecán/farmacocinética , Irinotecán/farmacología , Conejos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA