Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 93(5): 053303, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35649771

RESUMEN

Image plates (IPs) are a popular detector in the field of laser driven ion acceleration, owing to their high dynamic range and reusability. An absolute calibration of these detectors to laser-driven protons in the routinely produced tens of MeV energy range is, therefore, essential. In this paper, the response of Fujifilm BAS-TR IPs to 1-40 MeV protons is calibrated by employing the detectors in high resolution Thomson parabola spectrometers in conjunction with a CR-39 nuclear track detector to determine absolute proton numbers. While CR-39 was placed in front of the image plate for lower energy protons, it was placed behind the image plate for energies above 10 MeV using suitable metal filters sandwiched between the image plate and CR-39 to select specific energies. The measured response agrees well with previously reported calibrations as well as standard models of IP response, providing, for the first time, an absolute calibration over a large range of proton energies of relevance to current experiments.

2.
Sci Rep ; 7(1): 10891, 2017 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-28883424

RESUMEN

The characteristics of laser driven proton beams can be efficiently controlled and optimised by employing a recently developed helical coil technique, which exploits the transient self-charging of solid targets irradiated by intense laser pulses. Here we demonstrate a well collimated (<1° divergence) and narrow bandwidth (~10% energy spread) proton beamlet of ~107 particles at 10 ± 0.5 MeV obtained by irradiating helical coil targets with a few joules, sub-ps laser pulses at an intensity of ~2 × 1019 W cm-2. The experimental data are in good agreement with particle tracing simulations suggesting post-acceleration of protons inside the coil at a rate ~0.7 MeV/mm, which is comparable to the results obtained from a similar coil target irradiated by a fs class laser at an order of magnitude higher intensity, as reported in S. Kar et al., Nat. Commun, 7, 10792 (2016). The dynamics of hot electron escape from the laser irradiated target was studied numerically for these two irradiation regimes, which shows that the target self-charging can be optimised at a pulse duration of few hundreds of fs. This information is highly beneficial for maximising the post-acceleration gradient in future experiments.

3.
Sci Rep ; 7(1): 2399, 2017 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-28546551

RESUMEN

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1-100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from "noise", arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr-1, and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm-1, exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr-1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

4.
Phys Rev E ; 94(2-1): 023203, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27627403

RESUMEN

The collisional (or free-free) absorption of soft x rays in warm dense aluminium remains an unsolved problem. Competing descriptions of the process exist, two of which we compare to our experimental data here. One of these is based on a weak scattering model, another uses a corrected classical approach. These two models show distinctly different behaviors with temperature. Here we describe experimental evidence for the absorption of 26-eV photons in solid density warm aluminium (T_{e}≈1 eV). Radiative x-ray heating from palladium-coated CH foils was used to create the warm dense aluminium samples and a laser-driven high-harmonic beam from an argon gas jet provided the probe. The results indicate little or no change in absorption upon heating. This behavior is in agreement with the prediction of the corrected classical approach, although there is not agreement in absolute absorption value. Verifying the correct absorption mechanism is decisive in providing a better understanding of the complex behavior of the warm dense state.

5.
Nat Commun ; 7: 10642, 2016 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-26861592

RESUMEN

Tracking primary radiation-induced processes in matter requires ultrafast sources and high precision timing. While compact laser-driven ion accelerators are seeding the development of novel high instantaneous flux applications, combining the ultrashort ion and laser pulse durations with their inherent synchronicity to trace the real-time evolution of initial damage events has yet to be realized. Here we report on the absolute measurement of proton bursts as short as 3.5±0.7 ps from laser solid target interactions for this purpose. Our results verify that laser-driven ion acceleration can deliver interaction times over a factor of hundred shorter than those of state-of-the-art accelerators optimized for high instantaneous flux. Furthermore, these observations draw ion interaction physics into the field of ultrafast science, opening the opportunity for quantitative comparison with both numerical modelling and the adjacent fields of ultrafast electron and photon interactions in matter.

6.
Artículo en Inglés | MEDLINE | ID: mdl-25871224

RESUMEN

Fast-electron generation and dynamics, including electron refluxing, is at the core of understanding high-intensity laser-plasma interactions. This field is itself of strong relevance to fast ignition fusion and the development of new short-pulse, intense, x-ray, γ-ray, and particle sources. In this paper, we describe experiments that explicitly link fast-electron refluxing and anisotropy in hard-x-ray emission. We find the anisotropy in x-ray emission to be strongly correlated to the suppression of refluxing. In contrast to some previous work, the peak of emission is directly along the rear normal to the target rather than along either the incident laser direction or the specular reflection direction.

7.
Rev Sci Instrum ; 85(9): 093303, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25273715

RESUMEN

A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C(6+), O(8+), etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 85(5 Pt 2): 056415, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-23004887

RESUMEN

We present data on emission of K-shell radiation from Ti foils irradiated with subpicosecond pulses of second harmonic radiation (527 nm) from the TARANIS laser system at intensities of up to 10(18) W cm(-2). The data are used to demonstrate that a resonance absorption type mechanism is responsible for absorption of the laser light and to estimate fast electron temperatures of 30-60 keV that are in broad agreement with expectation from models of absorption for a steep density gradient. Data taken with resin-backed targets are used to demonstrate clear evidence of electron refluxing even at the modest fast electron temperatures inferred.

10.
Phys Rev Lett ; 97(3): 035001, 2006 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-16907506

RESUMEN

The temporal evolution of the opacity of an iron plasma at high temperature (30-350 eV) and high density (0.001-0.2 g cm-3) has been measured using a nickel-like silver x-ray laser at 13.9 nm. The hot dense iron plasma was created in a thin (50 nm) iron layer buried 80 nm below the surface in a plastic target that was heated using a separate 80 ps pulse of 6-9 J, focused to a 100 microm diameter spot. The experimental opacities are compared with opacities evaluated from plasma conditions predicted using a fluid and atomic physics code.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA