Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 89(1): 013508, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29390720

RESUMEN

The high resolution Thomson scattering system with 63 points along a 25 mm line measures the radial electron temperature (Te) and its density (ne) in an argon plasma. By using a DC arc source with lanthanum hexaboride (LaB6) electrode, plasmas with electron temperature of over 5 eV and densities of 1.5 × 1019 m-3 have been measured. The system uses a frequency doubled (532 nm) Nd:YAG laser with 0.25 J/pulse at 20 Hz. The scattered light is collected and sent to a triple-grating spectrometer via optical-fibers, where images are recorded by an intensified charge coupled device (ICCD) camera. Although excellent in stray-light reduction, a disadvantage comes with its relatively low optical transmission and in sampling a tiny scattering volume. Thus requires accumulating multitude of images. In order to improve photon statistics, pixel binning in the ICCD camera as well as enlarging the intermediate slit-width inside the triple-grating spectrometer has been exploited. In addition, the ICCD camera capture images at 40 Hz while the laser is at 20 Hz. This operation mode allows us to alternate between background and scattering shot images. By image subtraction, influences from the plasma background are effectively taken out. Maximum likelihood estimation that uses a parameter sweep finds best fitting parameters Te and ne with the incoherent scattering spectrum.

2.
Rev Sci Instrum ; 85(2): 02A916, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593495

RESUMEN

A new superconducting 18 GHz electron cyclotron resonance ion source is being developed at the National Fusion Research Institute in South Korea. This source will be dedicated for future application of highly charged ions in the area of matter interaction, diagnostic imaging, and probing. In this paper, we describe the status of the source development consisting of a double electrode biased disk, sputtering systems for metal ion production, diagnostic ports for the extraction region, a variable gap extraction-Einzel lens system, and a low energy beam transport system.

3.
Rev Sci Instrum ; 83(2): 02A326, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380173

RESUMEN

A superconducting magnet was designed and fabricated for an 18 GHz ECR ion∕photon source, which will be installed at National Fusion Research Institute (NFRI) in South Korea. The magnetic system consists of a set of four superconducting coils for axial mirror field and 36 pieces of permanent magnets for hexapolar field. The superconducting coils with a cryocooler (1.5 W @ 4.2 K) allow one to reach peak mirror fields of 2.2 T in the injection and those of 1.5 T in the extraction regions on the source axis, and the resultant hexapolar field gives 1.35 T on the plasma chamber wall. The unbalanced magnetic force between the coils and surrounding yoke has been minimized to 16 ton by a coil arrangement and their electrical connection, and then was successfully suspended by 12 strong thermal insulating supports made of large numbers of carbon fibers. In order to block radiative thermal losses, multilayer thermal insulations are covered on the coil windings as well as 40-K aluminum thermal shield. Also new schemes of quench detection and safety system (coil divisions, quench detection coils, and heaters) were employed. For impregnation of the windings a special epoxy has been selected and treated to have a higher breaking strength and a higher thermal conductivity, which enables the superconductors to be uniformly and rapidly cooled down or heated during a quench.


Asunto(s)
Ciclotrones , Electrones , Imanes , Fotones , Radiometría/instrumentación , Diseño de Equipo , Temperatura
4.
Rev Sci Instrum ; 79(2 Pt 2): 02A319, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315109

RESUMEN

The electron densities in the argon plasmas of the ORNL 6 GHz electron cyclotron resonance (ECR) ion source with a flat central magnetic field have been deduced from the ion branches of the electric probe current-voltage curves measured in the edge region of the plasmas. To overcome the difficulties due to unknown velocities of multiply charged ions at the sheath edge, a modified generalized Bohm criterion for the ion sheath velocity is introduced and the mean velocity of all ionic charge states at the sheath edge is assumed to be equal to the sound velocity of the system of particles. The calculated electron densities and temperatures for different plasmas optimized for four charge state distributions are discussed.


Asunto(s)
Diseño Asistido por Computadora , Ciclotrones/instrumentación , Electrones , Gases/química , Modelos Teóricos , Radiometría/métodos , Simulación por Computador , Calor , Iones , Dosis de Radiación , Electricidad Estática
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA