Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
Physiol Rep ; 11(21): e15860, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37960999

RESUMEN

Exercise-induced bronchoconstriction (EIB) is usually assessed by changes in forced expiratory volume in 1 s (FEV1 ) which is effort dependent. The purpose of this study was to determine whether the diaphragm electromyogram (EMGdi ) recorded from chest wall surface electrodes could be used to reflect changes in airway resistance during an exercise challenge test and to distinguish patients with EIB from those without EIB. Ninety participants with or without asthma history were included in the study. FEV1 was recorded before and 5, 10, 15, and 20 min after exercise. EIB was defined as an FEV1 decline greater than 10% after exercise. A ratio of root mean square of EMGdi to tidal volume (EMGdi /VT ) was used to assess changes in airway resistance. Based on changes in FEV1 , 25 of 90 participants exhibited EIB; the remainder were defined as non-EIB participants. EMGdi /VT in EIB increased by 124% (19%-478%) which was significantly higher than that of 21% (-39% to 134%) in non-EIB participants (p < 0.001). At the optimal cutoff point (54% in EMGdi /VT ), the area under the ROC curve (AUC) for detection of a positive test was 0.92 (p < 0.001) with sensitivity 92% and specificity 88%. EMGdi /VT can be used to assess changes in airway resistance after exercise and could be used to distinguish participants with EIB from those without EIB.


Asunto(s)
Asma Inducida por Ejercicio , Broncoconstricción , Humanos , Asma Inducida por Ejercicio/diagnóstico , Diafragma , Volumen de Ventilación Pulmonar , Electromiografía , Pruebas de Provocación Bronquial , Volumen Espiratorio Forzado , Prueba de Esfuerzo
2.
J Appl Physiol (1985) ; 135(5): 977-984, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37675475

RESUMEN

CO2 inhalation has been previously reported as a treatment for central sleep apnea both when associated with heart failure or where the cause is unknown. Here, we evaluated a novel CO2 supply system using a novel open mask capable of comfortably delivering a constantly inspired fraction of CO2 ([Formula: see text]) during sleep. We recruited 18 patients with central sleep apnea (13 patients with cardiac disease, and 5 patients idiopathic) diagnosed by diaphragm electromyogram (EMG) recordings made during overnight full polysomnography (PSG) (night 1). In each case, the optimal [Formula: see text] was determined by an overnight manual titration with PSG (night 2). Titration commenced at 1% CO2 and increased by 0.2% increments until central sleep apnea (CSA) disappeared. Patients were then treated on the third night (night 3) with the lowest therapeutically effective concentration of CO2 derived from night 2. Comparing night 1 and night 3, both apnea-hypopnea index (AHI; 31 ± 14 vs. 6 ± 3 events/h, P < 0.01) and arousal index (22 ± 8 vs. 15 ± 8 events/h, P < 0.01) were significantly improved during CO2 treatment. Sleep efficiency improved from 71 ± 18 to 80 ± 11%, P < 0.05, and sleep latency was shorter (23 ± 18 vs. 10 ± 10 min, P < 0.01). Heart rate was not different between night 1 and night 3. Our data confirm the feasibility of our CO2 delivery system and indicate that individually titrated CO2 supplementation with a novel device including a special open mask can reduce sleep disordered breathing severity and improve sleep quality. Randomized controlled studies should now be undertaken to assess therapeutic benefit for patients with CSA.NEW & NOTEWORTHY A novel device using a special mask was developed and proved that CO2 therapy using the device could eliminate central sleep apnea (CSA) events and improve sleep quality including reducing arousal index in patients with heart failure. The device would become a useful clinical treatment for heart failure patients with CSA.


Asunto(s)
Insuficiencia Cardíaca , Apnea Central del Sueño , Humanos , Dióxido de Carbono , Sueño , Presión de las Vías Aéreas Positiva Contínua , Insuficiencia Cardíaca/tratamiento farmacológico
3.
Ying Yong Sheng Tai Xue Bao ; 34(5): 1313-1319, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37236949

RESUMEN

The relationship between biodiversity and ecosystem stability is a hot topic in ecology. However, current studies focus mainly on aboveground system with plants, little attention has been paid to belowground system with soils. In this study, we constructed three soil suspensions with varying microbial diversity (100, 10-2, 10-6) by the dilution method and inoculated separately into agricultural Mollisols and Oxisols to examine the stability (indicated by resistance and resilience) of soil CO2 production and N2O emission to copper pollution and heat stress. Results showed that the stability of CO2 production in Mollisols was not influenced by microbial diversity loss, while the resistance and resilience of N2O emission in Mollisols were significantly decreased at the 10-6 diversity. In the Oxisols, the resistance and resilience of N2O emission to copper pollution and heat stress started to decrease even at the 10-2 diversity, and the stability of CO2 production decreased at the 10-6 diversity. These results suggested that both soil types and the identity of soil functions influenced the relationship between microbial diversity and the stability of function. It was concluded that soils with ample nutrients and resistant microbial communities tend to have higher functional stability, and that the fundamental soil functions (e.g., CO2 production) are more resistant and resilient than the specific soil functions (e.g., N2O emission) in response to environmental stress.


Asunto(s)
Ecosistema , Suelo , Dióxido de Carbono/análisis , Cobre , Agricultura , Microbiología del Suelo , Óxido Nitroso/análisis
4.
Sleep Breath ; 27(6): 2351-2359, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37211583

RESUMEN

PURPOSE: CPAP is the "gold standard" treatment for obstructive sleep apnea (OSA). Current CPAP models have developed additional functions including automatic CPAP and pressure relief. However, CPAP adherence has not improved over the last three decades. Many patients in low-income countries cannot afford these CPAP devices. A novel simple CPAP device with a fixed pressure without pressure controller was developed. METHODS: Manual CPAP pressure titration was performed in 127 patients with OSA. Six patients with a titration pressure higher than 11 cmH2O and 14 patients who could not tolerate CPAP were excluded, leaving 107 participating in the following 2 studies. In study one, 54 of 107 patients were treated by both conventional fixed CPAP and simple CPAP in random order. In the second study, another 53 patients were treated by both autoCPAP in automatic function and simple CPAP in random order. Simple CPAP was fixed at 10 cmH2O, 8 cmH2O, and 6 cmH2O for patients whose titration pressure was between 9-10, 7-8, and ≤ 6 cmH2O, respectively. Conventional fixed CPAP device was set exactly the same as manual titration pressure. RESULTS: All patients whose manual titration pressure ≤ 10 cmH2O were effectively treated by simple CPAP (AHI 40.7 ± 2.3 events/h before vs 2.5 ± 0.3 events/h after, p < 0.001). Patients expressed similar preferences for simple CPAP, autoCPAP, and conventional fixed CPAP (p > 0.05). CONCLUSIONS: We conclude that a novel simple CPAP is an alternative treatment for most patients with OSA, which may widen access to CPAP therapy in the developing countries because of its low cost.


Asunto(s)
Apnea Obstructiva del Sueño , Humanos , Polisomnografía , Apnea Obstructiva del Sueño/terapia , Presión de las Vías Aéreas Positiva Contínua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA