Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Surg Endosc ; 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914889

RESUMEN

BACKGROUND: Despite the global increase in the adoption of robotic natural orifice specimen extraction surgery (R-NOSES), its advantages over robotic transabdominal specimen extraction surgery (R-TSES) for treating early-stage rectal cancer remain debated. There is scant nationwide, multicenter studies comparing the surgical quality and short-term outcomes between R-NOSES and R-TSES for this condition. OBJECTIVE: This retrospective cohort study was conducted nationally across multiple centers to compare the surgical quality and short-term outcomes between R-NOSES and R-TSES in early-stage rectal cancer. DESIGN: Multicenter retrospective cohort trial. SETTING: Eight experienced surgeons from 8 high-volume Chinese colorectal cancer treatment centers. PATIENTS: The study included 1086 patients who underwent R-NOSES or R-TSES from October 2015 to November 2023 at the 8 centers. Inclusion criteria were: (1) histologically confirmed rectal adenocarcinoma; (2) robotic total mesorectal excision; (3) postoperative pathological staging of TisN0M0 or T1-2N0M0; (4) availability of complete surgical and postoperative follow-up data. Patients were matched 1:1 in the R-NOSES and R-TSES groups using the propensity score matching (PSM) technique. RESULTS: After PSM, 318 matched pairs with well-balanced patient characteristics were identified. The operation time for the R-NOSES group was significantly longer than that for the R-TSES group [140 min (125-170 min) vs. 140 min (120-160 min), P = 0.032]. Conversely, the times to first flatus and initial oral intake in the R-NOSES group were significantly shorter than those in the R-TSES group [48 h (41-56 h) vs. 48 h (44-62 h), P = 0.049 and 77 h (72-94 h) vs. 82 h (72-96 h), P = 0.008], respectively. Additionally, the length of postoperative hospital stay was shorter in the R-NOSES group compared with the R-TSES group [7 day (7-9 day) vs. 8 day (7-9 day), P = 0.005]. The overall postoperative complication rates were similar between the groups (10.7% in the R-NOSES group vs. 11.9% in the R-TSES group, P = 0.617). However, the R-NOSES group had a lower incidence of wound complications compared to the R-TSES group (0.0% vs. 2.2%, P = 0.015). Regarding surgical stress response, the R-NOSES group showed superior outcomes. Additionally, patients in the R-NOSES group required fewer additional analgesics on postoperative days 1, 3, and 5 and reported lower pain scores compared to the R-TSES group. The body image scale (BIS) and cosmetic scale (CS) scores were also significantly higher in the R-NOSES group. Furthermore, the R-NOSES group demonstrated significantly better outcomes in functional dimensions such as physical, role, emotional, social, and cognitive functioning, and in symptoms like fatigue and pain, when compared to the R-TSES group. LIMITATIONS: It is imperative to ensure the safe and standardized implementation of R-NOSES through the establishment of a uniform training protocol. CONCLUSIONS: These results affirm that R-NOSES is a safe and effective treatment for early-stage rectal cancer when meticulously executed by skilled surgeons.

2.
J Med Chem ; 67(12): 9789-9815, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38864348

RESUMEN

Carbon monoxide (CO) is endogenously produced in mammals, with blood concentrations in the high micromolar range in the hemoglobin-bound form. Further, CO has shown therapeutic effects in various animal models. Despite its reputation as a poisonous gas at high concentrations, we show that CO should have a wide enough safety margin for therapeutic applications. The analysis considers a large number of factors including levels of endogenous CO, its safety margin in comparison to commonly encountered biomolecules or drugs, anticipated enhanced safety profiles when delivered via a noninhalation mode, and the large amount of safety data from human clinical trials. It should be emphasized that having a wide enough safety margin for therapeutic use does not mean that it is benign or safe to the general public, even at low doses. We defer the latter to public health experts. Importantly, this Perspective is written for drug discovery professionals and not the general public.


Asunto(s)
Monóxido de Carbono , Monóxido de Carbono/metabolismo , Humanos , Animales
3.
J Org Chem ; 89(13): 9551-9556, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38888488

RESUMEN

Because of endogenous signaling roles of carbon monoxide (CO) and its demonstrated pharmacological effects, there has been extensive interests in developing fluorescent CO probes. Palladium-mediated CO insertion has been successfully used for such applications. However, recent years have seen many publications of using uncatalyzed CO insertion into a hydrazone double bond as a way to sense CO. Such chemistry has no precedents otherwise. Further, the rigor of the CO-sensing work was largely based on using ruthenium-carbonyl complexes such as CORM-3 as CO surrogates, which have been reported to have extensive chemical reactivity and to release largely CO2 instead of CO unless in the presence of a strong nucleophile such as dithionite. For all of these, it is important to reassess the feasibility of such a CO-insertion reaction. By studying two of the reported "CO probes" using CO gas, this study finds no evidence of CO insertion into a hydrazone double bond. Further, the chemical reaction between CO gas and a series of eight hydrazone compounds was conducted, leading to the same conclusion. Such findings are consistent with the state-of-the-art knowledge of carbonylation chemistry and do not support uncatalyzed CO insertion as a mechanism for developing fluorescent CO probes.

4.
Micromachines (Basel) ; 15(5)2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38793214

RESUMEN

In laser beam processing, the angle or offset between the auxiliary gas and the laser beam axis have been proved to be two new process optimization parameters for improving cutting speed and quality. However, a traditional electromechanical actuator cannot achieve high-speed and high-precision motion control with a compact structure. This paper proposes a magnetic levitation actuator which could realize the 5-DOF motion control of a lens using six groups of differential electromagnets. At first, the nonlinear characteristic of a magnetic driving force was analyzed by establishing an analytical model and finite element calculation. Then, the dynamic model of the magnetic levitation actuator was established using the Taylor series. And the mathematical relationship between the detected distance and five-degree-of-freedom was determined. Next, the centralized control system based on PID control was designed. Finally, a driving test was carried out to verify the five-degrees-of-freedom motion of the proposed electromagnetic levitation actuator. The results show it can achieve a stable levitation and precision positioning with a desired command motion. It also proves that the proposed magnetic levitation actuator has the potential application in an off-axis laser cutting machine tool.

5.
Adv Mater ; 36(24): e2311611, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38479726

RESUMEN

Topological photonics provide a promising way to realize more robust optical devices against some defects and environmental perturbations. Quantum logic gates are fundamental units of quantum computers, which are widely used in future quantum information processing. Thus, constructing robust universal quantum logic gates is an important way forward to practical quantum computing. However, the most important problem to be solved is how to construct the quantum-logic-gate-required 2 × 2 beam splitter with topological protection. Here, the experimental realization of the topologically protected contradirectional coupler is reported, which can be employed to realize the quantum logic gates, including control-NOT and Hadamard gates, on the silicon photonic platform. These quantum gates not only have high experimental fidelities but also exhibit a certain degree of tolerances against certain types of defects. This work paves the way for the development of practical optical quantum computations and signal processing.

6.
Nat Commun ; 15(1): 1647, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38388485

RESUMEN

Topological photonics provides a new degree of freedom to robustly control electromagnetic fields. To date, most of established topological states in photonics have been employed in Euclidean space. Motivated by unique properties of hyperbolic lattices, which are regular tessellations in non-Euclidean space with a constant negative curvature, the boundary-dominated hyperbolic topological states have been proposed. However, limited by highly crowded boundary resonators and complicated site couplings, the hyperbolic topological insulator has only been experimentally constructed in electric circuits. How to achieve hyperbolic photonic topological insulators is still an open question. Here, we report the experimental realization of hyperbolic photonic topological insulators using coupled ring resonators on silicon chips. Boundary-dominated one-way edge states with pseudospin-dependent propagation directions have been observed. Furthermore, the robustness of edge states in hyperbolic photonic topological insulators is also verified. Our findings have potential applications in the field of designing high-efficient topological photonic devices with enhanced boundary responses.

7.
Health Inf Sci Syst ; 12(1): 7, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38261831

RESUMEN

Thyroid ultrasound is a widely used diagnostic technique for thyroid nodules in clinical practice. However, due to the characteristics of ultrasonic imaging, such as low image contrast, high noise levels, and heterogeneous features, detecting and identifying nodules remains challenging. In addition, high-quality labeled medical imaging datasets are rare, and thyroid ultrasound images are no exception, posing a significant challenge for machine learning applications in medical image analysis. In this study, we propose a Dual-branch Attention Learning (DBAL) convolutional neural network framework to enhance thyroid nodule detection by capturing contextual information. Leveraging jigsaw puzzles as a pretext task during network training, we improve the network's generalization ability with limited data. Our framework effectively captures intrinsic features in a global-to-local manner. Experimental results involve self-supervised pre-training on unlabeled ultrasound images and fine-tuning using 1216 clinical ultrasound images from a collaborating hospital. DBAL achieves accurate discrimination of thyroid nodules, with a 88.5% correct diagnosis rate for malignant and benign nodules and a 93.7% area under the ROC curve. This novel approach demonstrates promising potential in clinical applications for its accuracy and efficiency.

8.
Ann Surg ; 279(5): 808-817, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38264902

RESUMEN

OBJECTIVE: To compare the short-term and long-term outcomes between robotic gastrectomy (RG) and laparoscopic gastrectomy (LG) for gastric cancer. BACKGROUND: The clinical outcomes of RG over LG have not yet been effectively demonstrated. METHODS: This retrospective cohort study included 3599 patients with gastric cancer who underwent radical gastrectomy at eight high-volume hospitals in China from January 2015 to June 2019. Propensity score matching was performed between patients who received RG and LG. The primary end point was 3-year disease-free survival (DFS). RESULTS: After 1:1 propensity score matching, 1034 pairs of patients were enrolled in a balanced cohort for further analysis. The 3-year DFS in the RG and LG was 83.7% and 83.1% ( P =0.745), respectively, and the 3-year overall survival was 85.2% and 84.4%, respectively ( P =0.647). During 3 years of follow-up, 154 patients in the RG and LG groups relapsed (cumulative incidence of recurrence: 15.0% vs 15.0%, P =0.988). There was no significant difference in the recurrence sites between the 2 groups (all P >0.05). Sensitivity analysis showed that RG had comparable 3-year DFS (77.4% vs 76.7%, P =0.745) and overall survival (79.7% vs 78.4%, P =0.577) to LG in patients with advanced (pathologic T2-4a) disease, and the recurrence pattern within 3 years was also similar between the 2 groups (all P >0.05). RG had less intraoperative blood loss, lower conversion rate, and shorter hospital stays than LG (all P >0.05). CONCLUSIONS: For resectable gastric cancer, including advanced cases, RG is a safe approach with comparable 3-year oncological outcomes to LG when performed by experienced surgeons.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Neoplasias Gástricas , Humanos , Resultado del Tratamiento , Estudios Retrospectivos , Neoplasias Gástricas/patología , Gastrectomía , Puntaje de Propensión , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía
9.
ACS Chem Neurosci ; 15(3): 400-407, 2024 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-38214656

RESUMEN

The dopaminergic system plays important roles in neuromodulation, including prominent roles in complex neurological functions such as cognition, reward, motivation, and memory. Understandably, the highly complex nature of such physiological functions means that their regulation is intertwined with other signaling pathways, as has been demonstrated by numerous studies. Contrary to its public perception of being poisonous at all concentrations, carbon monoxide (CO) is produced endogenously from heme degradation by heme oxygenase (HO) as part of the physiological process of red blood cell turnover. Physiological concentrations of CO can reach high micromolar ranges in the hemoglobin bound form. Low-dose CO has shown therapeutic effects in numerous animal models, including traumatic brain injury via engaging various hemoprotein targets. As such, the HO-CO axis has been shown to offer beneficial effects in organ protection, anti-inflammation, and neuroprotection, among many others. Further, a large number of publications have shown the interactions among CO, HO, and the dopaminergic system. In this review, we critically examine such experimental evidence in a holistic fashion and in the context of a possible dopamine-HO-CO signaling axis. We hope that this Perspective will stimulate additional investigations into the molecular connectivity related to this possible axis and open doors to the development of novel therapeutics that impact the dopaminergic system.


Asunto(s)
Monóxido de Carbono , Hemo Oxigenasa (Desciclizante) , Animales , Hemo Oxigenasa (Desciclizante)/metabolismo , Monóxido de Carbono/metabolismo , Dopamina , Transducción de Señal , Cognición , Hemo-Oxigenasa 1/metabolismo
10.
World J Gastrointest Surg ; 15(10): 2142-2153, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37969697

RESUMEN

BACKGROUND: Robotic resection using the natural orifice specimen extraction surgery I-type F method (R-NOSES I-F) is a novel minimally invasive surgical strategy for the treatment of lower rectal cancer. However, the current literature on this method is limited to case reports, and further investigation into its safety and feasibility is warranted. AIM: To evaluate the safety and feasibility of R-NOSES I-F for the treatment of low rectal cancer. METHODS: From September 2018 to February 2022, 206 patients diagnosed with low rectal cancer at First Affiliated Hospital of Nanchang University were included in this retrospective analysis. Of these patients, 22 underwent R-NOSES I-F surgery (R-NOSES I-F group) and 76 underwent conventional robotic-assisted low rectal cancer resection (RLRC group). Clinicopathological data of all patients were collected and analyzed. Postoperative outcomes and prognoses were compared between the two groups. Statistical analysis was performed using SPSS software. RESULTS: Patients in the R-NOSES I-F group had a significantly lower visual analog score for pain on postoperative day 1 (1.7 ± 0.7 vs 2.2 ± 0.6, P = 0.003) and shorter postoperative anal venting time (2.7 ± 0.6 vs 3.5 ± 0.7, P < 0.001) than those in the RLRC group. There were no significant differences between the two groups in terms of sex, age, body mass index, tumor size, TNM stage, operative time, intraoperative bleeding, postoperative complications, or inflammatory response (P > 0.05). Postoperative anal and urinary functions, as assessed by Wexner, low anterior resection syndrome, and International Prostate Symptom Scale scores, were similar in both groups (P > 0.05). Long-term follow-up revealed no significant differences in the rates of local recurrence and distant metastasis between the two groups (P > 0.05). CONCLUSION: R-NOSES I-F is a safe and effective minimally invasive procedure for the treatment of lower rectal cancer. It improves pain relief, promotes gastrointestinal function recovery, and helps avoid incision-related complications.

11.
BMC Surg ; 23(1): 336, 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37940918

RESUMEN

BACKGROUND: With the development of minimally invasive technology, the trauma caused by surgery get smaller, At the same time, the specimen extraction surgery through the natural orifice is more favored by experts domestically and abroad, robotic surgery has further promoted the development of specimen extraction surgery through the natural orifice. The aim of current study is to compare the short-term outcomes of robotic-assisted natural orifice specimen extraction (NOSES ) and transabdominal specimen extraction(TRSE ) in median rectal cancer surgery. METHODS: From January 2020 to January 2023, 87 patients who underwent the NOSES or TRSE at the First Affiliated Hospital of Nanchang University were included in the study, 4 patients were excluded due to liver metastasis. Of these, 50 patients were in the TRSE and 33 patients in the NOSES. Short-term efficacy was compared in the two groups. RESULTS: The NOSES group had less operation time (P < 0.001), faster recovery of gastrointestinal function (P < 0.001), shorter abdominal incisions (P < 0.001), lower pain scores(P < 0.001). lower Inflammatory indicators of the white blood cell count and C-reactive protein content at 1, 3, and 5 days after surgery (P < 0.001, P = 0.037). There were 9 complications in the NOSES group and 11 complications in the TRSE group(P = 0.583). However, there were no wound complications in the NOSES group. The number of postoperative hospital stays seems to be same in the two groups. And there was no significant difference in postoperative anus function (P = 0.591). CONCLUSIONS: This study shows that NOSES and TRSE can achieve similar radical treatment effects, NOSES is a feasible and safe way to take specimens for rectal cancer surgery in accordance with the indication for NOSES.


Asunto(s)
Laparoscopía , Neoplasias del Recto , Procedimientos Quirúrgicos Robotizados , Humanos , Estudios Retrospectivos , Neoplasias del Recto/cirugía , Recto , Resultado del Tratamiento
12.
Health Inf Sci Syst ; 11(1): 42, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37667773

RESUMEN

Background: Drug-target interaction (DTI) is a vital drug design strategy that plays a significant role in many processes of complex diseases and cellular events. In the face of challenges such as extensive protein data and experimental costs, it is suggested to apply bioinformatics approaches to exploit potential interactions to design new targeted medications. Different data and interaction types bring difficulties to study involving incompatible and heterology formats. The analysis of drug-target interactions in a comprehensive and unified model is a significant challenge. Method: Here, we propose a general method for predicting interactions between small-molecule drugs and protein targets, Large-scale Drug target Screening Convolutional Neural Network (LDS-CNN), which used unified encoding to achieve the calculation of the different data formats in an integrated model to realize feature abstraction and potential object prediction. Result: On 898,412 interaction data involving 1683 small-molecule compounds and 14,350 human proteins from 8.8 billion records, the proposed method achieved an area under the curve (AUC) of 0.96, an area under the precision-recall curve (AUPRC) of 0.95, and an accuracy of 90.13%. The experimental results illustrated that the proposed method attained high accuracy on the test set, indicating its high predictive ability in drug-target interaction prediction. LDS-CNN is effective for the prediction of large-scale datasets and datasets composed of data with different formats. Conclusion: In this study, we propose a DTI prediction method to solve the problems of unified encoding of large-scale data in multiple formats. It provides a feasible way to efficiently abstract the features among different types of drug-related data, thus reducing experimental costs and time consumption. The proposed method can be used to identify potential drug targets and candidates for the treatment of complex diseases. This work provides a reference for DTI to process large-scale data and different formats with deep learning methods and provides certain suggestions for future research.

13.
Micromachines (Basel) ; 14(8)2023 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-37630175

RESUMEN

This paper is concerned with electric-acoustic/acoustic-electric conversions of thin-wafer piezoelectric transducers polarized in the thickness direction. By introducing two mechanical components with frequency-dependent values, i.e., radiation resistance and radiation mass, into the equivalent circuit of the thin-wafer piezoelectric transducer, we established a frequency-dependent dynamic mechanic-electric equivalent network with four terminals for an arbitrary given frequency, an enhancement from the conventional circuit networks. We derived the analytic expressions of its electric-acoustic and acoustic-electric conversion impulse responses using the four-terminal equivalent circuit to replace the traditional six-terminal equivalent circuit for a thin-wafer transducer with harmonic vibrational motion. For multifrequency electrical/acoustic signals acting on the transducer, we established parallel electric-acoustic/acoustic-electric conversion transmission networks. These two transmission network models have simple structures and clear physical and mathematical descriptions of thin-wafer transducers for electric-acoustic/acoustic-electric conversion when excited by a multifrequency electric/acoustic signal wavelet. The calculated results showed that the transducer's center frequency shift relates to its mechanical load and vibration state. The method reported in this paper can be applied to conventional-sized and small-sized piezoelectric transducers with universal applicability.

14.
World J Surg Oncol ; 21(1): 196, 2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37403084

RESUMEN

BACKGROUND: Surgery is becoming less invasive as technology advances. Natural orifice specimen extraction surgery (NOSES) ushered in a new era of minimally invasive techniques. At the same time, NOSES is gaining popularity in the world. With their distinct advantages, surgical robots have advanced the development of NOSES. The aim of current study was to compare the short-term outcomes between robotic-assisted NOSES and laparoscopic-assisted NOSES for the treatment of middle rectal cancer. METHODS: Patients with middle rectal cancer who underwent robotic-assisted or laparoscopic-assisted NOSES at the First Affiliated Hospital of Nanchang University between January 2020 and June 2022 had their clinicopathological data collected retrospectively. 46 patients were enrolled in the study: 23 in the robotic group and 23 in the laparoscopic group. Short-term outcomes and postoperative anal function in the two groups were compared. RESULTS: There was no significant difference in the clinicopathological data between the two groups. The robotic group had less intraoperative blood loss (p = 0.04), less postoperative abdominal drainage (p = 0.02), lower postoperative white blood cell counts (p = 0.024) and C-reactive protein levels (p = 0.017), and shorter catheter removal time when compared to the laparoscopic group (p = 0.003). Furthermore, there were no significant difference in mean operative time (159 ± 31 min vs 172 ± 41 min) between the robotic and laparoscopic groups (p = 0.235), but time to naked the rectum (86.4 ± 20.9 min vs. 103.8 ± 31.5 min p = 0.033) and time of digestive tract reconstruction (15.6 ± 3.88 min vs. 22.1 ± 2.81 min p < 0.01) in the robotic group were significantly shorter than laparoscopic group. The robotic group had lower postoperative Wexner scores than the laparoscopic group. CONCLUSIONS: This research reveals that combining a robotic surgical system and NOSES results in superior outcomes, with short-term outcomes preferable to laparoscopic-assisted NOSES.


Asunto(s)
Laparoscopía , Neoplasias del Recto , Procedimientos Quirúrgicos Robotizados , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Laparoscopía/métodos , Neoplasias del Recto/cirugía
15.
Anal Chem ; 95(23): 9083-9089, 2023 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-37263968

RESUMEN

Carbon monoxide (CO) is an endogenous signaling molecule with demonstrated pharmacological effects. For studying CO biology, there is a need for sensitive and selective fluorescent probes for CO as research tools. In developing such probes, CO gas and/or commercially available metal-carbonyl-based "CO-releasing molecules" (CORMs) have been used as CO sources. However, new findings are steadily emerging that some of these commonly used CORMs do not release CO reliably in buffers commonly used for studying such CO probes and have very pronounced chemical reactivities of their own, which could lead to the erroneous identification of "CO probes" that merely detect the CORM used, not CO. This is especially true when the CO-sensing mechanism relies on chemistry that is not firmly established otherwise. Cu2+ can quench the fluorescence of an imine-based fluorophore, DPHP, presumably through complexation. The Cu2+-quenched fluorescence was restored through the addition of CORM-3, a Ru-based CORM. This approach was reported as a new "strategy for detecting carbon monoxide" with the proposed mechanism being dependent on CO reduction of Cu2+ to Cu1+ under near-physiological conditions ( Anal. Chem. 2022, 94, 11298-11306). The study only used CORM-3 as the source of CO. CORM-3 has been reported to have very pronounced redox reactivity and is known not to release CO in an aqueous solution unless in the presence of a strong nucleophile. To assess whether the fluorescent response of the DPHP-Cu(II) cocktail to CORM-3 was truly through detecting CO, we report experiments using both pure CO and CORM-3. We confirm the reported DPHP-Cu(II) response to CORM-3 but not pure CO gas. Further, we did not observe the stated selectivity of DPHP for CO over sulfide species. Along this line, we also found that a reducing agent such as ascorbate was able to induce the same fluorescent turn-on as CORM-3 did. As such, the DPHP-Cu(II) system is not a CO probe and cannot be used to study CO biology. Corollary to this finding, it is critical that future work in developing CO probes uses more than a chemically reactive "CO donor" as the CO source. Especially important will be to confirm the ability of the "CO probe" to detect CO using pure CO gas or another source of CO.

16.
Acta Pharm Sin B ; 13(5): 1990-2016, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37250163

RESUMEN

Click chemistry has been proven to be very useful in drug delivery. Due to the availability of a large number of click reactions with a various characteristics, selection of appropriate chemistry for a given application is often not a trivial task. This review is written for pharmaceutical researchers who are interested in click chemistry applications and yet may not be click chemistry experts. For this, the review gives an overview of available click reactions organized by application types. Further, the general understanding of click reactions being fast and high yielding sometimes overshadows the need to analyze reaction kinetics in assessing suitability of a given reaction for certain applications. For this, we highlight the need to analyze the relationship among reaction kinetics, concentration effects, and reaction time scales, knowing that lack of such analysis could easily lead to failures. Further, possible issues such as chemical stability with various click reagents are also discussed to aid experimental designs. Recent examples and extensive references are also provided to aid in-depth understanding of technical details. We hope this review will help those interested in using click chemistry in drug delivery to select the appropriate reactions/reagents and minimize the number of pitfalls.

17.
Sci Adv ; 9(21): eadg6685, 2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37235652

RESUMEN

Integrated quantum photonic circuit is a promising platform for the realization of quantum information processing in the future. To achieve the large-scale quantum photonic circuits, the applied quantum logic gates should be as small as possible for the high-density integration on chips. Here, we report the implementation of super-compact universal quantum logic gates on silicon chips by the method of inverse design. In particular, the fabricated controlled-NOT gate and Hadamard gate are both nearly a vacuum wavelength, being the smallest optical quantum gates reported up to now. We further design the quantum circuit by cascading these fundamental gates to perform arbitrary quantum processing, where the corresponding size is about several orders smaller than that of previous quantum photonic circuits. Our study paves the way for the realization of large-scale quantum photonic chips with integrated sources and can have important applications in the field of quantum information processes.

18.
Front Oncol ; 13: 1168961, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37091155

RESUMEN

Background: The transvaginal route for specimen extraction is considered ideal for colorectal surgery, but its safety is still questioned. There has been little research on transvaginal natural orifice specimen extraction surgery (NOSES) in the right hemicolectomy. As a result, we conducted a study comparing transvaginal NOSES to traditional transabdominal specimen extraction surgery. Patients and methods: Data on female patients who underwent radical right hemicolectomy at the First Affiliated Hospital of Nanchang University between January 2015 and December 2020 were collected retrospectively. A total of 847 patients were compliant, with 51 undergoing the transvaginal specimen extraction surgery (NOSES) group and 796 undergoing the transabdominal specimen extraction surgery (TISES) group. A propensity score matching method (1:2) was used to balance the clinicopathological characteristics of the two groups. Results: Finally, 138 patients were enrolled in our study, with 46 in the NOSES group and 92 in the TISES group. Compared to the TISES group, the NOSES group had less intraoperative blood loss (p = 0.036), shorter time to first flatus (p < 0.001), shorter time to first liquid diet (p < 0.001), lower postoperative white blood cell counts (p = 0.026), lower C-reactive protein levels (p = 0.027), and lower visual analog scale (VAS) scores (p < 0.001). Regarding the quality of life after surgery, the NOSES group had better role function (p < 0.01), emotional function (p < 0.001), and improved symptoms of postoperative pain (p < 0.001) and diarrhea (p = 0.024). The scar satisfaction was significantly higher in the NOSES group than in the TISES group. Overall survival and disease-free survival in two groups were similar. Conclusion: The short-term results of transvaginal NOSES were superior to conventional transabdominal specimen extraction surgery. At the same time, transvaginal NOSES could improve the abdominal wall appearance and quality of life. The long-term survival was similar in the two surgical approaches. Therefore, transvaginal NOSES is worthy of our implementation and promotion.

19.
Molecules ; 28(3)2023 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-36770961

RESUMEN

Hydrogen sulfide (H2S) is an essential signaling gas within the cell, and its endogenous levels are correlated with various health diseases such as Alzheimer's disease, diabetes, Down's syndrome, and cardiovascular disease. Because it plays such diverse biological functions, being able to detect H2S quickly and accurately in vivo is an area of heightened scientific interest. Using probes that fluoresce in the near-infrared (NIR) region is an effective and convenient method of detecting H2S. This approach allows for compounds of high sensitivity and selectivity to be developed while minimizing cytotoxicity. Herein, we report a review on the synthesis, mechanisms, optical properties, and selected biomedical applications of H2S sensors.


Asunto(s)
Colorantes Fluorescentes , Sulfuro de Hidrógeno , Transducción de Señal
20.
Front Oncol ; 13: 1120960, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36816958

RESUMEN

Background: The aim of the study was to develop and validate a nomogram for predicting cancer-specific survival (CSS) in lymph- node- positive rectal cancer patients after radical proctectomy. Methods: In this study, we analyzed data collected from the Surveillance, Epidemiology, and End Results (SEER) database between 2004 and 2015. In addition, in a 7:3 randomized design, all patients were split into two groups (development and validation cohorts). CSS predictors were selected via univariate and multivariate Cox regressions. The nomogram was constructed by analyzing univariate and multivariate predictors. The effectiveness of this nomogram was evaluated by concordance index (C-index), calibration plots, and receiver operating characteristic (ROC) curve. Based on the total score of each patient in the development cohort in the nomogram, a risk stratification system was developed. In order to analyze the survival outcomes among different risk groups, Kaplan-Meier method was used. Results: We selected 4,310 lymph- node- positive rectal cancer patients after radical proctectomy, including a development cohort (70%, 3,017) and a validation cohort (30%, 1,293). The nomogram correlation C-index for the development cohort and the validation cohort was 0.702 (95% CI, 0.687-0.717) and 0.690 (95% CI, 0.665-0.715), respectively. The calibration curves for 3- and 5-year CSS showed great concordance. The 3- and 5-year areas under the curve (AUC) of ROC curves in the development cohort were 0.758 and 0.740, respectively, and 0.735 and 0.730 in the validation cohort, respectively. Following the establishment of the nomogram, we also established a risk stratification system. According to their nomogram total points, patients were divided into three risk groups. There were significant differences between the low-, intermediate-, and high-risk groups (p< 0.05). Conclusions: As a result of our research, we developed a highly discriminatory and accurate nomogram and associated risk classification system to predict CSS in lymph-node- positive rectal cancer patients after radical proctectomy. This model can help predict the prognosis of patients with lymph- node- positive rectal cancer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA