2.
J Magn Reson ; 334: 107110, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34844075

RESUMEN

We present a proof-of-concept study focusing on a method for the intra- and inter-center validation and harmonization of data obtained from MRI T1 and T2 maps. The method is based on a set of MnCl2 samples that provide in-scan ground-truth reference values regardless of the details of the MRI protocol. The relaxation times of MnCl2 aqueous solutions were first measured by means of an NMR laboratory relaxometer, as a function of concentration and temperature. The obtained T1 and T2 values, once renormalized at the scanner temperature, were used as reference values for the MRI mapping measurements of the MnCl2 relaxation times. By using different clinical MRI scanners and sequences, we found a good agreement for standard and turbo sequences (limits of agreement: 5% for IR, SE, IR-TSE; 10% for TSE), while an under-estimation and an over-estimation were found respectively for MOLLI and T2-prep TrueFISP, as already reported in the literature. The linearity of the relaxation rates with the concentration predicted by the Solomon-Bloembergen-Morgan theory was observed for every dataset at all temperatures, except for T2-prep TrueFISP maps results. Some preliminary results of an in vivo experiment are also presented.


Asunto(s)
Imagen por Resonancia Magnética , Agua , Espectroscopía de Resonancia Magnética , Reproducibilidad de los Resultados
3.
Phys Med ; 85: 98-106, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33991807

RESUMEN

PURPOSE: The purpose of this multicenter phantom study was to exploit an innovative approach, based on an extensive acquisition protocol and unsupervised clustering analysis, in order to assess any potential bias in apparent diffusion coefficient (ADC) estimation due to different scanner characteristics. Moreover, we aimed at assessing, for the first time, any effect of acquisition plan/phase encoding direction on ADC estimation. METHODS: Water phantom acquisitions were carried out on 39 scanners. DWI acquisitions (b-value = 0-200-400-600-800-1000 s/mm2) with different acquisition plans (axial, coronal, sagittal) and phase encoding directions (anterior/posterior and right/left, for the axial acquisition plan), for 3 orthogonal diffusion weighting gradient directions, were performed. For each acquisition setup, ADC values were measured in-center and off-center (6 different positions), resulting in an entire dataset of 84 × 39 = 3276 ADC values. Spatial uniformity of ADC maps was assessed by means of the percentage difference between off-center and in-center ADC values (Δ). RESULTS: No significant dependence of in-center ADC values on acquisition plan/phase encoding direction was found. Ward unsupervised clustering analysis showed 3 distinct clusters of scanners and an association between Δ-values and manufacturer/model, whereas no association between Δ-values and maximum gradient strength, slew rate or static magnetic field strength was revealed. Several acquisition setups showed significant differences among groups, indicating the introduction of different biases in ADC estimation. CONCLUSIONS: Unsupervised clustering analysis of DWI data, obtained from several scanners using an extensive acquisition protocol, allows to reveal an association between measured ADC values and manufacturer/model of scanner, as well as to identify suboptimal DWI acquisition setups for accurate ADC estimation.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Análisis por Conglomerados , Difusión , Fantasmas de Imagen , Reproducibilidad de los Resultados
4.
World Neurosurg ; 151: e109-e121, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33819704

RESUMEN

OBJECTIVE: To evaluate the applicability of corticocortical evoked potentials (CCEP) for intraoperative monitoring of the language network in epilepsy surgery under general anesthesia. To investigate the clinical relevance on language functions of intraoperative changes of CCEP recorded under these conditions. METHODS: CCEP monitoring was performed in 14 epileptic patients (6 females, 4 children) during resections in the left perisylvian region under general anesthesia. Electrode strips were placed on the anterior language area (AL) and posterior language area (PL), identified by structural and functional magnetic resonance imaging. Single-pulse electric stimulations were delivered to pairs of adjacent contacts in a bipolar fashion. During resection, we monitored the integrity of the dorsal language pathway by stimulating either AL by recording CCEP from PL or vice versa, depending on stability and reproducibility of CCEP. We evaluated the first negative (N1) component of CCEP before, during, and after resection. RESULTS: All procedures were successfully completed without adverse events. The best response was obtained from AL during stimulation of PL in 8 patients and from PL during stimulation of AL in 6 patients. None of 12 patients with a postresection N1 amplitude decrease of 0%-15% from baseline presented postoperative language impairment. Decreases of 28% and 24%, respectively, of the N1 amplitude were observed in 2 patients who developed transient postoperative speech disturbances. CONCLUSIONS: The application of CCEP monitoring is possible and safe in epilepsy surgery under general anesthesia. Putative AL and PL can be identified using noninvasive presurgical neuroimaging. Decrease of N1 amplitude >15% from baseline may predict postoperative language deficits.


Asunto(s)
Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/cirugía , Epilepsia/diagnóstico por imagen , Epilepsia/cirugía , Potenciales Evocados , Monitorización Neurofisiológica Intraoperatoria/métodos , Trastornos del Lenguaje/etiología , Procedimientos Neuroquirúrgicos/efectos adversos , Procedimientos Neuroquirúrgicos/métodos , Adolescente , Adulto , Anestesia General , Niño , Preescolar , Electrodos , Electroencefalografía , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Red Nerviosa , Complicaciones Posoperatorias/diagnóstico , Reproducibilidad de los Resultados , Trastornos del Habla/etiología , Adulto Joven
5.
Tumori ; 107(6): NP41-NP44, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33629653

RESUMEN

OBJECTIVE: To outline a practical method of performing prostate cancer radiotherapy in patients with bilateral metal hip prostheses with the standard resources available in a modern general hospital. The proposed workflow is based exclusively on magnetic resonance imaging (MRI) to avoid computed tomography (CT) artifacts. CASE DESCRIPTION: This study concerns a 73-year-old man with bilateral hip prostheses with an elevated risk prostate cancer. Magnetic resonance images with assigned electron densities were used for planning purposes, generating a synthetic CT (sCT). Imaging acquisition was performed with an optimized Dixon sequence on a 1.5T MRI scanner. The images were contoured by autosegmentation software, based on an MRI database of 20 patients. The sCT was generated assigning averaged electron densities to each contour. Two volumetric modulated arc therapy plans, a complete arc and a partial one, where the beam entrances through the prostheses were avoided for about 50° on both sides, were compared. The feasibility of matching daily cone beam CT (CBCT) with MRI reference images was also tested by visual evaluations of different radiation oncologists. CONCLUSIONS: The use of magnetic resonance images improved accuracy in targets and organs at risk (OARs) contouring. The complete arc plan was chosen because of 10% lower mean and maximum doses to prostheses with the same planning target volume coverage and OAR sparing. The image quality of the match between performed CBCTs and MRI was considered acceptable. The proposed method seems promising to improve radiotherapy treatments for this complex category of patients.


Asunto(s)
Radioterapia de Iones Pesados/normas , Prótesis de Cadera/estadística & datos numéricos , Imagen por Resonancia Magnética/métodos , Prótesis Articulares de Metal sobre Metal/estadística & datos numéricos , Neoplasias de la Próstata/patología , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia Guiada por Imagen/métodos , Anciano , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Órganos en Riesgo , Neoplasias de la Próstata/radioterapia
6.
J Nephrol ; 34(3): 791-799, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33387337

RESUMEN

BACKGROUND AND OBJECTIVES: End stage renal disease (ESRD) patients are exposed to the risk of ionizing radiation during repeated imaging studies. The variability in diagnostic imaging policies and the accompanying radiation doses across various renal units is still unknown. We studied this variability at the centre level and quantified the associated radiation doses at the patient level. METHODS: Fourteen Italian nephrology departments enrolled 739 patients on haemodialysis and 486 kidney transplant patients. The details of the radiological procedures performed over one year were recorded. The effective doses and organ doses of radiation were estimated for each patient using standardized methods to convert exposure parameters into effective and organ doses RESULTS: Computed tomography (CT) was the major contributor (> 77%) to ionizing radiation exposure. Among the haemodialysis and kidney transplant patients, 15% and 6% were in the high (≥ 20 mSv per year) radiation dose groups, respectively. In haemodialysis patients, the most exposed organs were the liver (16 mSv), the kidney (15 mSv) and the stomach (14 mSv), while the uterus (6.2 mSv), the lung (5.7 mSv) and the liver (5.5 mSv) were the most exposed in kidney transplant patients. The average cumulative effective dose (CED) of ionizing radiation among centres in this study was highly variable both in haemodialysis (from 6.4 to 18.8 mSv per patient-year; p = 0.018) and even more so in kidney transplant (from 0.6 to 13.7 mSv per patient-year; p = 0.002) patients. CONCLUSIONS: Radiation exposure attributable to medical imaging is high in distinct subgroups of haemodialysis and transplant patients. Furthermore, there is high inter-centre variability in radiation exposure, suggesting that nephrology units have substantially different clinical policies for the application of diagnostic imaging studies.


Asunto(s)
Fallo Renal Crónico , Femenino , Humanos , Italia , Fallo Renal Crónico/diagnóstico por imagen , Fallo Renal Crónico/terapia , Dosis de Radiación , Diálisis Renal , Tomografía Computarizada por Rayos X
7.
J Neurosurg ; 135(3): 693-703, 2020 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-33307533

RESUMEN

OBJECTIVE: In this paper, the authors aimed to illustrate how Holmes tremor (HT) can occur as a delayed complication after brainstem cavernoma resection despite strict adherence to the safe entry zones (SEZs). METHODS: After operating on 2 patients with brainstem cavernoma at the Great Metropolitan Hospital Niguarda in Milan and noticing a similar pathological pattern postoperatively, the authors asked 10 different neurosurgery centers around the world to identify similar cases, and a total of 20 were gathered from among 1274 cases of brainstem cavernomas. They evaluated the tremor, cavernoma location, surgical approach, and SEZ for every case. For the 2 cases at their center, they also performed electromyographic and accelerometric recordings of the tremor and evaluated the post-operative tractographic representation of the neuronal pathways involved in the tremorigenesis. After gathering data on all 1274 brainstem cavernomas, they performed a statistical analysis to determine if the location of the cavernoma is a potential predicting factor for the onset of HT. RESULTS: From the analysis of all 20 cases with HT, it emerged that this highly debilitating tremor can occur as a delayed complication in patients whose postoperative clinical course has been excellent and in whom surgical access has strictly adhered to the SEZs. Three of the patients were subsequently effectively treated with deep brain stimulation (DBS), which resulted in complete or almost complete tremor regression. From the statistical analysis of all 1274 brainstem cavernomas, it was determined that a cavernoma location in the midbrain was significantly associated with the onset of HT (p < 0.0005). CONCLUSIONS: Despite strict adherence to SEZs, the use of intraoperative neurophysiological monitoring, and the immediate success of a resective surgery, HT, a severe neurological disorder, can occur as a delayed complication after resection of brainstem cavernomas. A cavernoma location in the midbrain is a significant predictive factor for the onset of HT. Further anatomical and neurophysiological studies will be necessary to find clues to prevent this complication.

8.
J Neuroimaging ; 29(4): 512-520, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31006947

RESUMEN

BACKGROUND AND PURPOSE: Periventricular nodular heterotopias (PNHs) are frequently associated with drug-resistant epilepsy (DRE). Although magnetic resonance imaging (MRI) can define the morphological features of PNHs, still there is a need to assess their metabolic activity in order to provide useful information on epileptogenicity and long-term outcome. To that end, we investigated the ability of 18 F-FDG PET to identify seizure onset zone in order to assess the metabolic activity of the ectopic neurons and to provide prognostic information on the postsurgical outcome. METHODS: Sixteen patients (6 men and 10 women; ranging between 24 and 53 years of age) with PNHs-related DRE were evaluated. All patients underwent clinical evaluation, Stereo-electroencephalogram (SEEG), brain MRI, and 18 F-FDG brain PET/CT. PET images were superimposed on the patient-specific 3-dimensional-brain MRI. The metabolic activity of each nodule and of their cortex was visually and semiquantitatively assessed. The outcome after intervention was assessed in all patients using Engel classification. RESULTS: Thirty-one heterotopic sites were identified. Twenty-one of 23 nodules with detectable electric activity on SEEG were identified by PET (91.3%), while 5 of 8 of nodules without electric activity showed no metabolism on PET (62.5%). Overall, the concordance between SEEG and FDG-PET was 26/31 (83.9%). Furthermore, cortical metabolic alterations were depicted, correlating with epileptogenic areas. A favorable postsurgical outcome was reported in 13 patients (81.3%). The presence of a hypometabolic nodule significantly correlated with a worse outcome after surgical therapy (P = .036). CONCLUSIONS: In PNHs-related epilepsy, FDG-PET more accurately identifies epileptogenic foci, which aids surgical planning and in postoperative seizure control.


Asunto(s)
Encéfalo/diagnóstico por imagen , Epilepsia/diagnóstico por imagen , Heterotopia Nodular Periventricular/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Electroencefalografía , Epilepsia/etiología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neuroimagen , Heterotopia Nodular Periventricular/complicaciones , Pronóstico , Adulto Joven
9.
Radiol Med ; 124(8): 721-727, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30953314

RESUMEN

The changes introduced with Council Directive 2013/59/Euratom will require European Member States adapt their regulations, procedures and equipment to the new high standards of radiation safety. These new requirements will have an impact, in particular, on the radiology community (including medical physics experts) and on industry. Relevant changes include new definitions, a new dose limit for the eye lens, non-medical imaging exposures, procedures in asymptomatic individuals, the use and regular review of diagnostic reference levels (including interventional procedures), dosimetric information in imaging systems and its transfer to the examination report, new requirements on responsibilities, the registry and analysis of accidental or unintended exposure and population dose evaluation (based on age and gender distribution). Furthermore, the Directive emphasises the need for justification of medical exposure (including asymptomatic individuals), introduces requirements concerning patient information and strengthens those for recording and reporting doses from radiological procedures, the use of diagnostic reference levels, the availability of dose-indicating devices and the improved role and support of the medical physics experts in imaging.


Asunto(s)
Exposición Profesional/legislación & jurisprudencia , Exposición a la Radiación/legislación & jurisprudencia , Protección Radiológica/legislación & jurisprudencia , Enfermedades Asintomáticas , Urgencias Médicas , Unión Europea , Física Sanitaria/legislación & jurisprudencia , Física Sanitaria/normas , Humanos , Cristalino/efectos de la radiación , Exposición Profesional/normas , Dosis de Radiación , Exposición a la Radiación/clasificación , Exposición a la Radiación/prevención & control , Exposición a la Radiación/normas , Protección Radiológica/instrumentación , Protección Radiológica/normas , Radiología/educación , Radiología/instrumentación , Radiología/legislación & jurisprudencia , Radiología/normas , Estándares de Referencia , Seguridad/legislación & jurisprudencia , Seguridad/normas
10.
Phys Med ; 55: 135-141, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30342982

RESUMEN

PURPOSE: To propose an MRI quality assurance procedure that can be used for routine controls and multi-centre comparison of different MR-scanners for quantitative diffusion-weighted imaging (DWI). MATERIALS AND METHODS: 44 MR-scanners with different field strengths (1 T, 1.5 T and 3 T) were included in the study. DWI acquisitions (b-value range 0-1000 s/mm2), with three different orthogonal diffusion gradient directions, were performed for each MR-scanner. All DWI acquisitions were performed by using a standard spherical plastic doped water phantom. Phantom solution ADC value and its dependence with temperature was measured using a DOSY sequence on a 600 MHz NMR spectrometer. Apparent diffusion coefficient (ADC) along each diffusion gradient direction and mean ADC were estimated, both at magnet isocentre and in six different position 50 mm away from isocentre, along positive and negative AP, RL and HF directions. RESULTS: A good agreement was found between the nominal and measured mean ADC at isocentre: more than 90% of mean ADC measurements were within 5% from the nominal value, and the highest deviation was 11.3%. Away from isocentre, the effect of the diffusion gradient direction on ADC estimation was larger than 5% in 47% of included scanners and a spatial non uniformity larger than 5% was reported in 13% of centres. CONCLUSION: ADC accuracy and spatial uniformity can vary appreciably depending on MR scanner model, sequence implementation (i.e. gradient diffusion direction) and hardware characteristics. The DWI quality assurance protocol proposed in this study can be employed in order to assess the accuracy and spatial uniformity of estimated ADC values, in single- as well as multi-centre studies.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/instrumentación , Difusión , Fantasmas de Imagen , Control de Calidad