RESUMEN
Importance: Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective: To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants: The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions: Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures: The composite coprimary clinical end point comprised death, disabling stroke, or heart failure-related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results: A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference -2.3%; 95% CI -7.2 to 2.5, P = .35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference, -33.4%; 95% CI, -40.4 to -26.4; P < .001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance: Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration: ClinicalTrials.gov Identifier: NCT04722250.
RESUMEN
Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (<3 mm; n = 412), optimal (3-7 mm; n = 1236), and low (>7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Diseño de PrótesisRESUMEN
In patients with prevalent or incident atrial fibrillation (AF) after successful transcatheter aortic valve implantation (TAVI) enrolled in the EdoxabaN Versus standard of care and theIr effectS on clinical outcomes in pAtients havinG undergonE Transcatheter Aortic Valve Implantation - in Atrial Fibrillation (ENVISAGE-TAVI AF) trial, the incidence of ischemic stroke (IS) and any stroke was numerically less in the edoxaban group than in the vitamin K antagonist (VKA) group. The present study aimed to identify risk factors associated with IS in an on-treatment subanalysis in patients from ENVISAGE-TAVI AF who received ≥1 dose of edoxaban or VKA. Baseline patient characteristics were compared in patients with and those without IS. Numerical variables were compared using a 1-way analysis of variance; categorical variables were compared using Fisher's exact test. Stepwise Cox regression determined patient characteristics associated with the first IS event. Of 1,377 patients, 41 (3.0%) experienced an IS, and 1,336 (97.0%) did not; baseline demographics and clinical characteristics were well balanced between groups. Most ISs occurred within 180 days of TAVI for edoxaban (57.9%) and VKA (68.2%). The rate of IS was 2.0/100 person-years for edoxaban versus 2.7/100 person-years for VKA. Independently associated with IS were history of systemic embolic events (hazard ratio 2.96, 95% confidence interval 1.26 to 7.00, pâ¯=â¯0.01) and pre-TAVI use of VKAs (hazard ratio 2.17, 95% confidence interval 1.12 to 4.20, pâ¯=â¯0.02). In conclusion, although the overall incidence of IS was small for patients with AF on edoxaban or VKA after successful TAVI, patients with a history of systemic embolic events or pre-TAVI use of VKAs may be at greater risk of IS after TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Inhibidores del Factor Xa , Accidente Cerebrovascular Isquémico , Piridinas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Masculino , Femenino , Accidente Cerebrovascular Isquémico/epidemiología , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular Isquémico/etiología , Factores de Riesgo , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Inhibidores del Factor Xa/uso terapéutico , Incidencia , Piridinas/uso terapéutico , Tiazoles/uso terapéutico , Anciano , Complicaciones Posoperatorias/epidemiología , Vitamina K/antagonistas & inhibidoresRESUMEN
Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.
RESUMEN
BACKGROUND: Despite the recommendation of coronary physiology to guide revascularization in angiographically intermediate stenoses without established correlation to ischemia, its uptake in clinical practice is slow. AIMS: This study aimed to analyze the use of coronary physiology in clinical practice. METHODS: Based on a multicenter registry (Fractional Flow Reserve Fax Registry, F(FR)2, ClinicalTrials.gov identifier NCT03055910), clinical use, consequences, and complications of coronary physiology were systematically analyzed. RESULTS: F(FR)2 enrolled 2,000 patients with 3,378 intracoronary pressure measurements. Most measurements (96.8%) were performed in angiographically intermediate stenoses. Out of 3,238 lesions in which coronary physiology was used to guide revascularization, revascularization was deferred in 2,643 (78.2%) cases. Fractional flow reserve (FFR) was the most common pressure index used (87.6%), with hyperemia induced by an intracoronary bolus of adenosine in 2,556 lesions (86.4%) and intravenous adenosine used for 384 measurements (13.0%). The route of adenosine administration did not influence FFR results (change-in-estimate -3.1% for regression model predicting FFR from diameter stenosis). Agreement with the subsequent revascularization decision was 93.4% for intravenous and 95.0% for intracoronary adenosine (p = 0.261). Coronary artery occlusion caused by the pressure wire was reported in two cases (0.1%) and dissection in three cases (0.2%), which was fatal once (0.1%). CONCLUSIONS: In clinical practice, intracoronary pressure measurements are mostly used to guide revascularization decisions in angiographically intermediate stenoses. Intracoronary and intravenous administration of adenosine seem equally suited. While the rate of serious complications of wire-based intracoronary pressure measurements in clinical practice seems to be low, it is not negligible.
Asunto(s)
Angiografía Coronaria , Estenosis Coronaria , Vasos Coronarios , Reserva del Flujo Fraccional Miocárdico , Sistema de Registros , Humanos , Reserva del Flujo Fraccional Miocárdico/fisiología , Masculino , Femenino , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico , Persona de Mediana Edad , Vasos Coronarios/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Anciano , Adenosina/administración & dosificación , Revascularización Miocárdica/métodos , Cateterismo Cardíaco/métodos , Vasodilatadores/administración & dosificaciónRESUMEN
BACKGROUND: Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic angle (AA) has an impact on procedural outcomes. Matched comparative outcome data of new generation transcatheter heart valves (THVs) in horizontal aorta (HA) are scarce. METHODS: A total of 1582 patients with severe native aortic stenosis (AS) treated with the SAPIEN3 Ultra (Ultra; n = 526) or ACURATE Neo2 (Neo2; n = 1056) THVs from January 2017 to January 2023 were analyzed. Patients with non-horizontal aortas (AA < 51.7°, n = 841) were excluded. The population was matched by 1-to-1 nearest-neighbor matching (Ultra, n = 246; Neo2, n = 246). Clinical and procedural outcome were evaluated according to VARC-3 recommendations. RESULTS: Technical success (93.1% vs. 94.7%, p = 0.572) was high after Ultra and Neo2. Device success (80.5% vs. 89.8%, p = 0.05) was inferior with Ultra. Neo2 reveals superior hemodynamic properties with lower rate of severe prosthesis patient mismatch (12.0% vs. 3.7%, p = 0.001) and elevated gradients ( ≥ $\ge $ 20 mmHg: 11.9% vs. 1.7%, p < 0.001). Ultra showed a lower rate of relevant paravalvular regurgitation ( > $\gt $ mild paravalvular regurgitation or Valve-in-Valve due to paravalvular regurgitation: 0.0% vs. 3.7%, p = 0.004). The rate of procedural bailout maneuvers (0.8% vs. 0.4%, p = 1.000) and thirty-day all-cause mortality (1.3% vs. 2.2%, p = 0.496) was similar. CONCLUSION: Transfemoral TAVR in patients with severe aortic stenosis and HA, using the balloon expandable Sapien3 Ultra and self-expanding ACURATE Neo2 prosthesis, is feasible and safe. Therefore, valve selection between these platforms should be made irrespective of the aortic angle by a team experienced with both valves based on their specific advantages. Large, randomized trials in this sub-group of patients would be necessary to compare long term outcomes.
RESUMEN
BACKGROUND: Severe tricuspid regurgitation (TR) is known to be associated with poor quality of life and increased risk of death when left untreated. OBJECTIVES: We sought to report the 1-year clinical outcomes of subjects treated by tricuspid transcatheter edge-to-edge repair (TEER) with the TriClip system (Abbott Cardiovascular) in a contemporary real-world setting. METHODS: The bRIGHT (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip Device) postapproval study is a prospective, single-arm, open-label, multicenter postmarket registry conducted at 26 sites in Europe, with central event adjudication and echocardiographic core-laboratory assessment. RESULTS: Enrolled subjects (n = 511) were elderly (79 ± 7 years) with significant comorbidities. A total of 88% had baseline massive or torrential TR, and 80% of subjects were in NYHA functional class III/IV. TR was reduced to moderate or less in 81% at 1 year. Significant improvements in NYHA functional class (21% to 75% I/II, P < 0.0001) and Kansas City Cardiomyopathy Questionnaire (KCCQ) score (19 ± 26-point improvement, P <0.0001) were observed at 1 year. One-year mortality was significantly lower in subjects who achieved moderate or lower TR at 30 days; however, there was no difference in mortality among subjects who achieved moderate, mild, or trace TR at 30 days. In addition to TR reduction at 30 days, baseline serum creatinine and baseline right ventricular tricuspid annular plane systolic excursion (RV TAPSE) were independently associated with mortality at 1 year (OR: 2.169; 95% CI: 1.494-3.147; P < 0.0001; OR: 0.636; 95% CI: 0.415-0.974; P = 0.0375). Mortality was not associated with baseline TR grade or with center volume. CONCLUSIONS: Tricuspid TEER using the TriClip system was safe and effective through 1 year for subjects with significant TR and advanced disease in a diverse real-world population. (An Observational Real-world Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip Device [bRIGHT]; NCT04483089).
Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/mortalidad , Masculino , Femenino , Anciano , Estudios Prospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Sistema de Registros , Anciano de 80 o más Años , Estudios de Seguimiento , Ecocardiografía , Calidad de Vida , Cateterismo Cardíaco/métodos , Europa (Continente)/epidemiología , Factores de Tiempo , Índice de Severidad de la EnfermedadRESUMEN
BACKGROUND: The latest generation ultrathin Supraflex Cruz (Sahajanand Medical Technologies Limited, Surat, India) sirolimus-eluting stent (SES) has shown early healing properties and represents an attractive percutaneous coronary intervention (PCI) device in a high bleeding risk (HBR) population. The aim of this Cruz HBR registry was to assess safety and efficacy of the Supraflex Cruz SES in a large cohort of all-comer patients, of whom about one third were patients at HBR. METHODS: Patients undergoing PCI were enrolled in this prospective, multi-centre, open label registry and stratified into non-HBR and HBR groups. The primary endpoint was a device-oriented composite endpoint (DOCE), a composite of cardiovascular death, myocardial infarction not clearly attributable to a non-target vessel and clinically driven target lesion revascularization within 12 months after PCI. The predefined aims were to show non-inferiority of the non-HBR group to the Supraflex arm of the TALENT Trial, and of the HBR group to polymer-free biolimus-coated stent arm of LEADERS FREE Trial. RESULTS: A total of 1203 patients were enrolled across 26 European centers, including a significant proportion (38.7%; N.=466) of HBR patients. A total of 1745 lesions were treated in 1203 patients and 2235 stents were implanted. The DOCE occurred within the total cohort in 5.8% of patients with a significant difference between HBR patients and non-HBR patients (8.1% vs. 4.4%; P<0.001). All-cause mortality at 12 months was significantly (P<0.0001) different among HBR (9.0%) and non-HBR patients (1.7%), respectively. At 12 months, the overall incidence of definite and probable stent thrombosis was 1.0%. Major bleeding occurred in 5.9% patients of the HBR group. These results met the non-inferiority criteria with respect to the TALENT trial for the non-HBR group (P<0.0001), and the LEADERS FREE trial for the HBR group (P<0.0001). CONCLUSIONS: The Cruz HBR registry confirms that PCI with the Supraflex Cruz SES is associated with a favorable clinical outcome in an all-comer population, including complex patients with HBR.
Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Hemorragia , Intervención Coronaria Percutánea , Polímeros , Sistema de Registros , Sirolimus , Humanos , Stents Liberadores de Fármacos/efectos adversos , Sirolimus/administración & dosificación , Sirolimus/uso terapéutico , Masculino , Femenino , Enfermedad de la Arteria Coronaria/cirugía , Estudios Prospectivos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Anciano , Persona de Mediana Edad , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Resultado del Tratamiento , Europa (Continente)/epidemiología , Implantes Absorbibles , Diseño de Prótesis , Factores de RiesgoRESUMEN
BACKGROUND: There are different definitions of periprocedural myocardial infarction (PPMI) both in terms of thresholds for cardiac biomarkers and the ancillary criteria for myocardial ischemia. Cardiac Troponin I (cTnI) and cardiac Troponin T (cTnT) are used interchangeably to diagnose PPMI. OBJECTIVES: This study evaluated the frequency of periprocedural myocardial injury and infarction as defined by the Society of Cardiovascular Angiography & Interventions (SCAI), the Academic Research Consortium-2 (ARC-2), and the 4th Universal definition of MI (4UDMI) stratified using cTnT versus cTnI, among patients with chronic coronary syndrome (CCS) and unstable angina. RESULTS: Among 830 patients, PPMI rates according to the SCAI, ARC2 and 4UDMI criteria were 4.34 %, 2.05 %, and 4.94 % respectively, with higher rates seen for all definitions when using cTnI versus cTnT (SCAI: 9.84 % vs. 1.91 %, p < 0.001; ARC 2: 3.15 % vs. 1.56 %, p = 0.136; and 4UDMI 5.91 % vs. 4.51 %, p = 0.391). Minor and major periprocedural myocardial injury was respectively observed in 58.31 % and 27.10 % of patients, with rates of both significantly higher when using cTnI versus cTnT (Minor: 69.29 % vs. 53.47 %, p < 0.001, Major: 49.21 % vs. 17.36 %, p < 0.001). CONCLUSIONS: Among patients with CCS and unstable angina, PPMIs defined by SCAI occurred more frequently when using cTnI as opposed to cTnT, whereas the type of troponin had no impact on the incidence of PPMIs according to the ARC-2 and 4UDMI.
RESUMEN
Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural â§moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of â§moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.
RESUMEN
BACKGROUND: The optimal treatment for coronary calcified nodules (CNs) is still unclear. The aim of this study was to compare the modification of these lesions by coronary intravascular lithotripsy (IVL) and rotational atherectomy (RA) using optical coherence tomography (OCT). METHODS: ROTA.shock was a 1:1 randomized, prospective, double-arm multi-center non-inferiority trial that compared the use of IVL and RA with percutaneous coronary intervention (PCI) in severely calcified lesions. In 19 of the patients out of this study CNs were detected by OCT in the target lesion and were treated by either IVL or RA. RESULTS: The mean angle of CNs was significantly larger in final OCT scans than before RA (92 ± 17° vs. 68 ± 7°; p = 0.01) and IVL (89 ± 18° vs. 60 ± 10°; p = 0.03). The CNs were thinner upon final scans than in initial native scans (RA: 17.8 ± 7.8 mm vs. 38.6 ± 13.1 mm; p = 0.02; IVL: 16.5 ± 9.0 mm vs. 37.2 ± 14.3 mm; p = 0.02). Nodule volume did not differ significantly between native and final OCT scans (RA: 0.66 ± 0.12 mm3 vs. 0.61 ± 0.33 mm3; p = 0.68; IVL: 0.64 ± 0.19 mm3 vs. 0.68 ± 0.22 mm3; p = 0.74). Final stent eccentricity was high with 0.62 ± 0.10 after RA and 0.61 ± 0.09 after IVL. CONCLUSION: RA or IVL are unable to reduce the volume of the calcified plaque. CN modulation seems to be mainly induced by the stent implantation and not by RA or IVL.
RESUMEN
BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Bioprótesis/efectos adversos , Insuficiencia Cardíaca , Estimación de Kaplan-Meier , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Falla de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.
Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Estudios de Seguimiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversosRESUMEN
BACKGROUND: In patients not suitable for transfemoral transcatheter aortic valve implantation (TAVI), several access strategies can be chosen. AIM: To evaluate the use and patient outcomes of transaxillary (TAx), transapical (TA), and transaortic (TAo) as alternative access for TAVI in Germany; to further evaluate surgical cutdown vs. percutaneous TAx access. METHODS: All patients entered the German Aortic Valve Registry (GARY) between 2011 and 2019 who underwent non-transfemoral TAVI were included in this analysis. Patients with TA, TAo, or TAx TAVI were compared using a weighted propensity score model. Furthermore, a subgroup analysis was performed for TAx regarding the percutaneous or surgical cutdown approach. RESULTS: Overall, 9686 patients received a non-transfemoral access. A total of 8918 patients (92.1%) underwent TA, 398 (4.1%) TAo, and 370 (3.8%) TAx approaches. Within the TAx subgroup, 141 patients (38.1%) received subclavian cutdown, while 200 (54.1%) underwent a percutaneous approach. The TA patients had a significantly lower 30-day survival than TAx patients (TA 90.92% vs. TAx 95.59%, p = 0.006; TAo 92.22% vs. TAx 95.59%, p = 0.102). Comparing percutaneous and cutdown TAx approaches, no significant differences were seen. However, more vascular complications occurred (TA 1.8%, TAo 2.4%, TAx 12.2%; p < .001), and the hospital length of stay was shorter (TA 12.9 days, TAo 14.1 days, TAx 12 days; p < .001) after TAx access. CONCLUSION: It may be reasonable to consider TAx access first in patients not suitable for TF-TAVI, because the 30-day survival was higher compared with TA access and the 1-year survival was higher compared with TAo access. It remains important for the heart teams to offer alternative access modalities for patients not amenable to the standard TF-TAVI approaches.
RESUMEN
BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.
Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversosRESUMEN
BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mmâ Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.
Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Masculino , Femenino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Medición de Riesgo , Estudios Retrospectivos , Puntaje de Propensión , Recuperación de la Función , Valvuloplastia con Balón/efectos adversos , HemodinámicaRESUMEN
BACKGROUND: Patients with atrial fibrillation (AF) and a recent (≤ 90 days) percutaneous coronary intervention (PCI) undergoing transcatheter aortic valve implantation (TAVI) are at high bleeding risk due to the addition of oral antiplatelet (OAP) agents on top of oral anticoagulants. Data on outcomes of these patients are needed to optimize antithrombotic treatment. METHODS: This analysis compared annualized clinical event rates in patients with and without a recent PCI enrolled in ENVISAGE-TAVI AF, a prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban and vitamin K antagonists in AF patients after TAVI. The primary efficacy and safety outcomes were net adverse clinical events (NACE) and major bleeding. RESULTS: Overall, 132 (94.3%) patients with a recent PCI (n = 140) received OAP after TAVI, compared with 692 (55.9%) patients without a recent PCI (n = 1237). Among patients with a recent PCI on OAP agents, use of dual antiplatelet therapy decreased to 5.5%, and use of single antiplatelet therapy (SAPT) increased to 78.0% over 3 months post-randomization. Conversely, use of SAPT predominated at all time points in patients without a recent PCI history. There were no significant differences in the incidence of NACE or other outcomes assessed, except for major bleeding events, which were more frequent in patients with vs without a recent PCI history (hazard ratio [95% confidence interval]: 2.17 [1.27, 3.73]; P = 0.005). CONCLUSIONS: Patients with AF undergoing TAVI with a recent PCI have a similar risk of ischemic events and mortality, but an increased risk of major bleeding compared with patients without a recent PCI.
RESUMEN
Background: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier: NCT03752866.