Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
2.
J Diabetes Sci Technol ; : 19322968241245627, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613225

RESUMEN

BACKGROUND: Benefits of hybrid closed-loop (HCL) systems in a high-risk group with type 1 diabetes and impaired awareness of hypoglycemia (IAH) have not been well-explored. METHODS: Adults with Edmonton HYPO scores ≥1047 were randomized to 26-weeks HCL (MiniMed™ 670G) vs standard therapy (multiple daily injections or insulin pump) without continuous glucose monitoring (CGM) (control). Primary outcome was percentage CGM time-in-range (TIR; 70-180 mg/dL) at 23 to 26 weeks post-randomization. Major secondary endpoints included magnitude of change in counter-regulatory hormones and autonomic symptom responses to hypoglycemia at 26-weeks post-randomization. A post hoc analysis evaluated glycemia risk index (GRI) comparing HCL with control groups at 26 weeks post-randomization. RESULTS: Nine participants (median [interquartile range (IQR)] age 51 [41, 59] years; 44% male; enrolment HYPO score 1183 [1058, 1308]; Clarke score 6 [6, 6]; n = 5 [HCL]; n = 4 [control]) completed the study. Time-in-range was higher using HCL vs control (70% [68, 74%] vs 48% [44, 50%], P = .014). Time <70 mg/dL did not differ (HCL 3.8% [2.7, 3.9] vs control 6.5% [4.3, 8.6], P = .14) although hypoglycemia episode duration was shorter (30 vs 50 minutes, P < .001) with HCL. Glycemia risk index was lower with HCL vs control (38.1 [30.0, 39.2] vs 70.8 [58.5, 72.4], P = .014). Following 6 months of HCL use, greater dopamine (24.0 [12.3, 27.6] vs -18.5 [-36.5, -4.8], P = .014), and growth hormone (6.3 [4.6, 16.8] vs 0.5 [-0.8, 3.0], P = .050) responses to hypoglycemia were observed. CONCLUSIONS: Six months of HCL use in high-risk adults with severe IAH increased glucose TIR and improved GRI without increased hypoglycemia, and partially restored counter-regulatory responses. CLINICAL TRIAL REGISTRATION: ACTRN12617000520336.

3.
JCEM Case Rep ; 2(4): luae051, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38601064

RESUMEN

Primary aldosteronism (PA) is the most common form of secondary hypertension. Accurate subtyping of PA is essential to identify unilateral disease, as adrenalectomy improves outcomes. Subtyping PA requires adrenal vein sampling (AVS), which is technically challenging and results from AVS may not always be conclusive. We present a case of a 37-year-old man with PA whose AVS studies were inconclusive due to apparent bilateral aldosterone suppression (ABAS). As a result, our patient was misdiagnosed as having bilateral PA and medically managed until a repeat AVS showed lateralization to the right adrenal gland. ABAS is an underrecognized phenomenon that may confound the subtyping of PA. We recommend repeating AVS in such cases and discuss strategies to minimize ABAS.

5.
Diabetes Technol Ther ; 26(3): 190-197, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38444313

RESUMEN

Aim: To assess the real-world performance of MiniMed™ 780G for Australians with type 1 diabetes (T1D) following advanced hybrid closed loop (AHCL) activation and to evaluate the effect of changing from MiniMed 670/770G to 780G. Methods: We analyzed deidentified Carelink™ continuous glucose monitoring (CGM) data from Australian users from January 2020 to December 2022, including the proportion attaining three major consensus targets: Glucose management indicator (GMI <7.0%), time in range (TIR 70-180 mg/dL >70%), and time below range (TBR 70 mg/dL <4%). Results: Comparing 670/770G users (n = 5676) for mean ± standard deviation 364 ± 244 days with 780G users (n = 3566) for 146 ± 145 days, the latter achieved a higher TIR (72.6% ± 10.6% vs. 67.3% ± 11.4%; P < 0.001), lower time above range (TAR) (25.5% ± 10.9% vs. 30.6% ± 11.7%; P < 0.001), and lower GMI (6.9% ± 0.4% vs. 7.2% ± 0.4%; P < 0.001) without compromising TBR (1.9% ± 1.8% vs. 2.0% ± 1.8%; P = 0.0015). Of 1051 670/770G users transitioning to 780G, TIR increased (70.0% ± 10.7% to 74.0% ± 10.2%; P < 0.001), TAR decreased (28.1% ± 10.9% to 24.0% ± 10.7%; P < 0.001), and TBR was unchanged. The percentage of users attaining all three CGM targets was higher in 780G users (50.1% vs. 29.5%; P < 0.001). CGM metrics were stable at 12 months post-transition. Conclusion: Real-world data from Australia shows that a higher proportion of MiniMed 780G users meet clinical targets for CGM consensus metrics compared to MiniMed 670/770G users and glucose control was sustained over 12 months.


Asunto(s)
Pueblos de Australasia , Automonitorización de la Glucosa Sanguínea , Insulina , Humanos , Australia , Glucemia , Insulina/uso terapéutico , Insulina Regular Humana
6.
J Diabetes Complications ; 38(3): 108702, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38387103

RESUMEN

AIMS: To relate adverse events with glucose correction rates in diabetic ketoacidosis (DKA) using variable rate intravenous insulin-infusions (VRIII). METHODS: Retrospective, observational study in adults with DKA who received insulin infusions between 2012 and 2017 at St Vincent's Hospital, Melbourne. Early correction of hyperglycaemia (<10 mmol/L) was evaluated for association with hypoglycaemia (<4.0 mmol/L), hypokalaemia (potassium <3.3 mmol/L) and clinical outcomes via regression analysis. RESULTS: The study involved 97 patients, with 93 % having type 1 diabetes. The mean age was 38 years, 47 % were women and 35 % were admitted to intensive care. Hypoglycaemia rates during 12 and 24 h of treatment were 6.2 % and 8.2 %, respectively with 58 % of patients recording their first BGL <10 mmol/L within 12 h and 88 % within 24 h. Ketone clearance time averaged at 15.6 h. Hyperglycaemia correction rates to <10 mmol/L were not different in those with/without hypoglycaemia at 12/24 h, in multivariate analysis including admission BGL. Hypokalaemia occurred in 40.2 % of patients and was associated with lower pH but not BGL correction rates. CONCLUSION: The VRIII protocol achieved early hyperglycaemia correction and ketoacidosis reversal with low hypoglycaemia risk. However, high hypokalaemia rates suggest the need for aggressive potassium replacement, especially in markedly acidotic patients.


Asunto(s)
Diabetes Mellitus , Cetoacidosis Diabética , Hiperglucemia , Hipoglucemia , Hipopotasemia , Adulto , Femenino , Humanos , Masculino , Cetoacidosis Diabética/tratamiento farmacológico , Cetoacidosis Diabética/epidemiología , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipopotasemia/inducido químicamente , Hipopotasemia/epidemiología , Insulina/efectos adversos , Insulina Regular Humana , Potasio , Estudios Retrospectivos
7.
Diabetes Technol Ther ; 26(5): 335-340, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38315502

RESUMEN

Older adults with type 1 diabetes may face challenges driving safely. Glucose "above-5-to-drive" is often recommended for insulin-treated diabetes to minimize hypoglycemia while driving. However, the effectiveness of this recommendation among older adults has not been evaluated. Older drivers with type 1 diabetes were assessed while using sensor-augmented insulin pumps during a 2-week clinical trial run-in. Twenty-three drivers (median age 69 years [interquartile range; IQR 65-72]; diabetes duration 37 years [20-45]) undertook 618 trips (duration 10 min [5-21]). Most trips (n = 535; 87%) were <30 min duration; 9 trips (1.5%) exceeded 90 min and 3 trips (0.5%) exceeded 120 min. Pre-trip continuous glucose monitoring (CGM) was >5.0 mmol/L for 577 trips (93%) and none of these had CGM <3.9 mmol/L during driving (including 8 trips >90 min and 3 trips >120 min). During 41 trips with pre-trip CGM ≤5.0 mmol/L, 11 trips had CGM <3.9 mmol/L. Seventy-one CGM alerts occurred during 60 trips (10%), of which 54 of 71 alerts (76%) were unrelated to hypoglycemia. Our findings support a glucose "above-5-to-drive" recommendation to avoid CGM-detected hypoglycemia among older drivers, including for prolonged drives, and highlight the importance of active CGM low-glucose alerts to prevent hypoglycemia during driving. Driving-related CGM usability and alert functionality warrant investigation. Clinical trial ACTRN1261900515190.


Asunto(s)
Conducción de Automóvil , Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemia , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Anciano , Masculino , Femenino , Glucemia/análisis , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Insulina/uso terapéutico , Persona de Mediana Edad
8.
Diabetes Care ; 47(4): 747-755, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38381515

RESUMEN

OBJECTIVE: To determine feasibility and compare acceptance of an investigational Medtronic enhanced advanced hybrid closed-loop (e-AHCL) system in adults with type 1 diabetes with earlier iterations. RESEARCH DESIGN AND METHODS: This nonrandomized three-stage (12 weeks each) exploratory study compared e-AHCL (Bluetooth-enabled MiniMed 780G insulin pump with automatic data upload [780G] incorporating an updated algorithm; calibration-free all-in-one disposable sensor; 7-day infusion set) preceded by a run-in (non-Bluetooth 780G [670G V4.0 insulin pump] requiring manual data upload; Guardian Sensor 3 [GS3] requiring calibration; 3-day infusion set), stage 1 (780G; GS3; 3-day infusion set), and stage 2 (780G; calibration-free Guardian Sensor 4; 3-day infusion set). Treatment satisfaction was assessed by Diabetes Technology Questionnaire (DTQ)-current (primary outcome) and other validated treatment satisfaction tools with glucose outcomes by continuous glucose monitoring metrics. RESULTS: Twenty-one of 22 (11 women) participants (baseline HbA1c 6.7%/50 mmol/mol) completed the study. DTQ-current scores favored e-AHCL (123.1 [17.8]) versus run-in (101.6 [24.2]) and versus stage 1 (110.6 [20.8]) (both P < 0.001) but did not differ from stage 2 (119.4 [16.0]; P = 0.271). Diabetes Medication System Rating Questionnaire short-form scores for "Convenience and Efficacy" favored e-AHCL over run-in and all stages. Percent time in range 70-180 mg/dL was greater with e-AHCL versus run-in and stage 2 (+2.9% and +3.6%, respectively; both P < 0.001). Percent times of <70 mg/dL for e-AHCL were significantly lower than run-in, stage 1, and stage 2 (-0.9%, -0.6%, and -0.5%, respectively; all P < 0.01). CONCLUSIONS: e-AHCL was feasible. User satisfaction increased compared with earlier Medtronic HCL iterations without compromising glucose control.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulinas , Adulto , Humanos , Femenino , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Algoritmos , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico
10.
Intern Med J ; 54(1): 121-128, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37255209

RESUMEN

BACKGROUND AND AIMS: Automated insulin delivery (AID) improves glycaemia among people with type 1 diabetes in clinical trials and overseas real-world studies. Whether improvements are sustained beyond 12 months in the real world, and whether they occur in the Australian context, has not yet been established. We aimed to observe, up to 2 years, the effectiveness of initiating first-generation AID for type 1 diabetes management. METHODS: Retrospective, real-world, observational study using medical records, conducted across five sites in Australia. Adults with type 1 diabetes, who had AID initiated between February 2019 and December 2021, were observed for 6-24 months after initiation (until June 2022). Outcomes examined included glucose metrics assessed by glycated haemoglobin (HbA1c ) and continuous glucose monitoring (CGM), safety and therapy continuation. RESULTS: Ninety-four adults were studied (median age 39 years (interquartile range, IQR: 31-51); pre-initiation HbA1c 7.8% (7.2-8.6)). After AID initiation, HbA1c decreased by mean 0.5 percentage points (95% confidence interval (CI): -0.7 to -0.2) at 3 months (P < 0.001); CGM time in range 3.9-10.0 mmol/L increased by 11 percentage points (9-14) at 1 month (P < 0.001); these improvements were maintained up to 24 months (all P < 0.02). Median CGM time below 3.9 mmol/L was <1.5% pre- and post-AID initiation. The subgroup with pre-initiation HbA1c above 8.5% had the greatest HbA1c improvement (-1.4 percentage points (-1.8 to -1.1) at 3 months). Twelve individuals (13%) discontinued AID, predominantly citing difficulties with CGM. During the 150 person-years observed, four diabetes-related emergencies were documented: three severe hypoglycaemic events and one hyperglycaemic event without ketoacidosis. CONCLUSIONS: Early glucose improvements were observed after real-world AID initiation, sustained up to 2 years, without excess adverse events. The greatest benefits were observed among individuals with highest glycaemia before initiation. Future-generation systems with increased user-friendliness may enhance therapy continuation.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/inducido químicamente , Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Estudios Retrospectivos , Australia/epidemiología , Hipoglucemiantes , Sistemas de Infusión de Insulina
11.
N Engl J Med ; 389(23): 2140-2150, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38055252

RESUMEN

BACKGROUND: Janus kinase (JAK) inhibitors, including baricitinib, block cytokine signaling and are effective disease-modifying treatments for several autoimmune diseases. Whether baricitinib preserves ß-cell function in type 1 diabetes is unclear. METHODS: In this phase 2, double-blind, randomized, placebo-controlled trial, we assigned patients with type 1 diabetes diagnosed during the previous 100 days to receive baricitinib (4 mg once per day) or matched placebo orally for 48 weeks. The primary outcome was the mean C-peptide level, determined from the area under the concentration-time curve, during a 2-hour mixed-meal tolerance test at week 48. Secondary outcomes included the change from baseline in the glycated hemoglobin level, the daily insulin dose, and measures of glycemic control assessed with the use of continuous glucose monitoring. RESULTS: A total of 91 patients received baricitinib (60 patients) or placebo (31 patients). The median of the mixed-meal-stimulated mean C-peptide level at week 48 was 0.65 nmol per liter per minute (interquartile range, 0.31 to 0.82) in the baricitinib group and 0.43 nmol per liter per minute (interquartile range, 0.13 to 0.63) in the placebo group (P = 0.001). The mean daily insulin dose at 48 weeks was 0.41 U per kilogram of body weight per day (95% confidence interval [CI], 0.35 to 0.48) in the baricitinib group and 0.52 U per kilogram per day (95% CI, 0.44 to 0.60) in the placebo group. The levels of glycated hemoglobin were similar in the two trial groups. However, the mean coefficient of variation of the glucose level at 48 weeks, as measured by continuous glucose monitoring, was 29.6% (95% CI, 27.8 to 31.3) in the baricitinib group and 33.8% (95% CI, 31.5 to 36.2) in the placebo group. The frequency and severity of adverse events were similar in the two trial groups, and no serious adverse events were attributed to baricitinib or placebo. CONCLUSIONS: In patients with type 1 diabetes of recent onset, daily treatment with baricitinib over 48 weeks appeared to preserve ß-cell function as estimated by the mixed-meal-stimulated mean C-peptide level. (Funded by JDRF International and others; BANDIT Australian New Zealand Clinical Trials Registry number, ACTRN12620000239965.).


Asunto(s)
Diabetes Mellitus Tipo 1 , Células Secretoras de Insulina , Inhibidores de las Cinasas Janus , Humanos , Australia , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Péptido C/sangre , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/análisis , Insulina/uso terapéutico , Inhibidores de las Cinasas Janus/efectos adversos , Inhibidores de las Cinasas Janus/farmacología , Inhibidores de las Cinasas Janus/uso terapéutico , Células Secretoras de Insulina/efectos de los fármacos , Método Doble Ciego
12.
Diabetes Ther ; 14(12): 1997-2014, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37824027

RESUMEN

Tirzepatide is a first-in-class GIP/GLP-1 receptor agonist ('twincretin')-a single molecule that acts as an agonist at both glucagon-like peptide 1 (GLP-1) and glucose-dependent insulinotropic polypeptide (GIP) receptors. In the SURPASS clinical trial program in type 2 diabetes mellitus (T2D), tirzepatide was associated with unprecedented reductions in HbA1c, clinically significant weight loss and other metabolic benefits, combined with low rates of hypoglycaemia across a wide range of patient characteristics. The safety and adverse event rate for tirzepatide appears comparable to that of GLP-1 receptor agonists. Although results from dedicated cardiovascular (CV) and kidney trials are currently not available, information to date suggests that tirzepatide may have CV and kidney benefits in people with T2D. Tirzepatide has been approved for the treatment of T2D in the USA, United Arab Emirates, European Union, Japan and Australia. Here, we review how tirzepatide will fit into the T2D treatment continuum. We also consider future directions with tirzepatide in T2D, including its potential for targeting cardio-renal-metabolic disease in T2D, and discuss how tirzepatide-and other co-agonists in development-may challenge current approaches for management of T2D.

13.
World J Diabetes ; 14(7): 942-957, 2023 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-37547594

RESUMEN

Diabetes-related foot disease (DFD) is a widely feared complication among people who live with diabetes. In Australia and globally, rates of disability, cardio-vascular disease, lower extremity amputation, and mortality are significantly increased in patients with DFD. In order to understand and prevent these outcomes, we analyse the common pathogenetic processes of neuropathy, arterial disease, and infection. The review then summarises important management considerations through the interdisciplinary lens. Using Australian and international guidelines, we offer a stepwise, evidence-based practical approach to the care of patients with DFD.

14.
Bioelectron Med ; 9(1): 16, 2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37464423

RESUMEN

BACKGROUND: Autonomic nerve stimulation is used as a treatment for a growing number of diseases. We have previously demonstrated that application of efferent vagus nerve stimulation (eVNS) has promising glucose lowering effects in a rat model of type 2 diabetes. This paradigm combines high frequency pulsatile stimulation to block nerve activation in the afferent direction with low frequency stimulation to activate the efferent nerve section. In this study we explored the effects of the parameters for nerve blocking on the ability to inhibit nerve activation in the afferent direction. The overarching aim is to establish a blocking stimulation strategy that could be applied using commercially available implantable pulse generators used in the clinic. METHODS: Male rats (n = 20) had the anterior abdominal vagus nerve implanted with a multi-electrode cuff. Evoked compound action potentials (ECAP) were recorded at the proximal end of the electrode cuff. The efficacy of high frequency stimulation to block the afferent ECAP was assessed by changes in the threshold and saturation level of the response. Blocking frequency and duty cycle of the blocking pulses were varied while maintaining a constant 4 mA current amplitude. RESULTS: During application of blocking at lower frequencies (≤ 4 kHz), the ECAP threshold increased (ANOVA, p < 0.001) and saturation level decreased (p < 0.001). Application of higher duty cycles (> 70%) led to an increase in evoked neural response threshold (p < 0.001) and a decrease in saturation level (p < 0.001). During the application of a constant pulse width and frequency (1 or 1.6 kHz, > 70% duty cycle), the charge delivered per pulse had a significant influence on the magnitude of the block (ANOVA, p = 0.003), and was focal (< 2 mm range). CONCLUSIONS: This study has determined the range of frequencies, duty cycles and currents of high frequency stimulation that generate an efficacious, focal axonal block of a predominantly C-fiber tract. These findings could have potential application for the treatment of type 2 diabetes.

16.
J Diabetes Sci Technol ; : 19322968231174040, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37162092

RESUMEN

Diabetes is the leading cause of chronic kidney disease (CKD) and end-stage kidney disease in the world. It is known that maintaining optimal glycemic control can slow the progression of CKD. However, the failing kidney impacts glucose and insulin metabolism and contributes to increased glucose variability. Conventional methods of insulin delivery are not well equipped to adapt to this increased glycemic lability. Automated insulin delivery (AID) has been established as an effective treatment in patients with type 1 diabetes mellitus, and there is emerging evidence for their use in type 2 diabetes mellitus. However, few studies have examined their role in diabetes with concurrent advanced CKD. We discuss the potential benefits and challenges of AID use in patients with diabetes and advanced CKD, including those on dialysis.

17.
Diabetes Technol Ther ; 25(7): 497-506, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37010375

RESUMEN

This study examined correlations between continuous glucose monitoring (CGM)-based composite metrics and standard glucose metrics within CGM data sets from individuals with recent-onset and long-duration type 1 diabetes. First, a literature review and critique of published CGM-based composite metrics was undertaken. Second, composite metric results were calculated for the two CGM data sets and correlations with six standard glucose metrics were examined. Fourteen composite metrics met selection criteria; these metrics focused on overall glycemia (n = 8), glycemic variability (n = 4), and hypoglycemia (n = 2), respectively. Results for the two diabetes cohorts were similar. All eight metrics focusing on overall glycemia strongly correlated with glucose time in range; none strongly correlated with time below range. The eight overall glycemia-focused and two hypoglycemia-focused composite metrics were all sensitive to automated insulin delivery therapeutic intervention. Until a composite metric can adequately capture both achieved target glycemia and hypoglycemia burden, the current two-dimensional CGM assessment approach may offer greatest clinical utility.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucemia , Automonitorización de la Glucosa Sanguínea/métodos , Benchmarking , Hipoglucemia/diagnóstico
19.
Diabet Med ; 40(4): e15020, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36468784

RESUMEN

AIM: To explore the lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery, an area previously receiving minimal attention. METHODS: Semi-structured interviews were conducted with adults aged 60 years or older with long-duration type 1 diabetes who participated in a randomised, open-label, two-stage crossover trial comparing first-generation closed-loop therapy (MiniMed 670G) versus sensor-augmented pump therapy. Interview recordings were transcribed, thematically analysed and assessed. RESULTS: Twenty-one older adults participated in interviews after using closed-loop therapy. Twenty were functionally independent, without frailty or major cognitive impairment; one was dependent on caregiver assistance, including for diabetes management. Quality of life benefits were identified, including improved sleep and reduced diabetes-related psychological burden, in the context of experiencing improved glucose levels. Gaps between expectations and reality of closed-loop therapy were also experienced, encountering disappointment amongst some participants. The cost was perceived as a barrier to continued closed-loop access post-trial. Usability issues were identified, such as disruptive overnight alarms and sensor inaccuracy. CONCLUSIONS: The lived experience of older adults without frailty or major cognitive impairment using first-generation closed-loop therapy was mainly positive and concordant with glycaemic benefits found in the trial. Older adults' lived experience using automated insulin delivery beyond trial environments requires exploration; moreover, the usability needs of older adults should be considered during future device development.


Asunto(s)
Diabetes Mellitus Tipo 1 , Fragilidad , Humanos , Anciano , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Calidad de Vida , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Automonitorización de la Glucosa Sanguínea , Estudios Cruzados , Glucemia
20.
Intern Med J ; 53(1): 27-36, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36269315

RESUMEN

BACKGROUND AND AIMS: A relationship between diabetes, glucose and COVID-19 outcomes has been reported in international cohorts. This study aimed to assess the relationship between diabetes, hyperglycaemia and patient outcomes in those hospitalised with COVID-19 during the first year of the Victorian pandemic prior to novel variants and vaccinations. DESIGN, SETTING: Retrospective cohort study from March to November 2020 across five public health services in Melbourne, Australia. PARTICIPANTS: All consecutive adult patients admitted to acute wards of participating institutions during the study period with a diagnosis of COVID-19, comprising a large proportion of patients from residential care facilities and following dexamethasone becoming standard-of-care. Admissions in patients without known diabetes and without inpatient glucose testing were excluded. RESULTS: The DINGO COVID-19 cohort comprised 840 admissions. In 438 admissions (52%), there was no known diabetes or in-hospital hyperglycaemia, in 298 (35%) patients had known diabetes, and in 104 (12%) patients had hyperglycaemia without known diabetes. ICU admission was more common in those with diabetes (20%) and hyperglycaemia without diabetes (49%) than those with neither (11%, P < 0.001 for all comparisons). Mortality was higher in those with diabetes (24%) than those without diabetes or hyperglycaemia (16%, P = 0.02) but no difference between those with in-hospital hyperglycaemia and either of the other groups. On multivariable analysis, hyperglycaemia was associated with increased ICU admission (adjusted odds ratio (aOR) 6.7, 95% confidence interval (95% CI) 4.0-12, P < 0.001) and longer length of stay (aOR 173, 95% CI 11-2793, P < 0.001), while diabetes was associated with reduced ICU admission (aOR 0.55, 95% CI 0.33-0.94, P = 0.03). Neither diabetes nor hyperglycaemia was independently associated with in-hospital mortality. CONCLUSIONS: During the first year of the COVID-19 pandemic, in-hospital hyperglycaemia and known diabetes were not associated with in-hospital mortality, contrasting with published international experiences. This likely mainly relates to hyperglycaemia indicating receipt of mortality-reducing dexamethasone therapy. These differences in published experiences underscore the importance of understanding population and clinical treatment factors affecting glycaemia and COVID-19 morbidity within both local and global contexts.


Asunto(s)
COVID-19 , Diabetes Mellitus , Hiperglucemia , Adulto , Humanos , Glucosa , Pandemias , COVID-19/epidemiología , Estudios Retrospectivos , Diabetes Mellitus/epidemiología , Hiperglucemia/epidemiología , Hospitales , Mortalidad Hospitalaria , Dexametasona/uso terapéutico , Unidades de Cuidados Intensivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA