Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
J Vasc Surg ; 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39074740

RESUMEN

OBJECTIVE: Endovascular repair of aortic dissections may be complicated by inadequate sealing zones, persistent false lumen (FL) perfusion, and limited space for catheter manipulation and target artery incorporation. The aim of this study was to describe the indications, technical success, and early outcomes of transcatheter electrosurgical septotomy (TES) during endovascular repair of aortic dissections. METHODS: We reviewed the clinical data of consecutive patients treated by endovascular repair of aortic dissections with adjunctive TES in two centers between 2021-2023. Endpoints were technical success, defined by successful septotomy without dislodgment of the lamella or target artery occlusion, and 30-day rates of major adverse events (MAEs). RESULTS: Among 197 patients treated by endovascular repair for aortic dissections, 36 (18%) patients (median age, 61.5 years (IQR 55-72.5); 83% males) underwent adjunctive TES for acute (n = 3, 8%), subacute (n = 1, 3%), or chronic post-dissection aneurysms (n = 32, 89%). Indications for TES were severe true lumen (TL) compression (≤ 16mm) in 28 patients (78%), target vessel origin from FL in 19 (53%), creation of suitable landing zone in 12 (33%), and organ/limb malperfusion in four (11%). Endovascular repair included fenestrated-branched endovascular aortic repair (FB-EVAR) in 18 patients (50%), thoracic EVAR (TEVAR)/ EVAR/PETTICOAT in 11 (31%), and arch branch repair in 7 (19%). All patients had dissections extending through Zones 5 to 7, and 28 patients (78%) underwent TES across the renal-mesenteric segment. Technical success of TES was 92% (33/36) for all patients and 97% (32/33) among those with subacute or chronic post-dissection aneurysms. There were three technical failures, including two patients with acute dissections with inadvertent SMA dissection in one patient and distal dislodgement of the dissection lamella in two patients. There were no arterial disruptions. Mean post-septotomy aortic lumen increased from 13.2±4.8mm to 28.4±6.8mm (P<.001). All 18 patients treated by FB-EVAR had successful incorporation of 78 target arteries. There was one (3%) early death from stroke, and three (8%) patients had MAEs. After a median follow-up of 8 months (IQR, 4.5-13.5 months), 13 (36%) patients had secondary interventions, and two (6%) died from non-aortic-related events. There were no other complications associated with TES. CONCLUSION: TES is an adjunctive technique that may optimize sealing zones and luminal aortic diameter during endovascular repair of subacute and chronic post-dissection. Although no arterial disruptions or target vessel loss occurred, but patients with acute dissections are prone to technical failures related to dislodgement of the lamella.

2.
Ultrasound Med Biol ; 50(9): 1479-1483, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38849280

RESUMEN

OBJECTIVE: Ultrasound beams sometimes need to be steered from the edge of linear array transducers to reach the sample volume with a desired Doppler angle in vascular exams. This phantom study aims to evaluate the impact of apertures located at the array edge on peak velocity (PV) measurements. METHODS: Three ultrasound scanner systems equipped with eight transducers from 3 major ultrasound vendors were tested using a flow phantom with a horizontal tube. Five spectral Doppler measurements with the aperture positioned at one edge of the array and 5 with the aperture at the center of the array were obtained using all available scanner-transducer combinations while maintaining all scan parameters and the sample volume in the same tube location. Differences in PVs between center and edge apertures were compared across 4 constant flow rates. RESULTS: The averaged PVs for all phantom flow rates ranged from 24.4 cm/s to 138.2 cm/s from the array center. The averaged PVs from the center aperture were significantly greater than the corresponding measurements from the edge aperture for each flow rate (all p < 0.001). The relative PV differences ranged from 6.7% to 19.4% across all transducers and flow rates. CONCLUSION: Significantly lower PVs were consistently shown with the Doppler beam aperture at the array edge compared to center among all tested systems. This may be due to a narrower aperture width, shifted central axis, and less intrinsic spectral broadening error at the array edge. Controlling variations in Doppler aperture location is important in clinical applications which depend on consistent velocity measurements.


Asunto(s)
Diseño de Equipo , Fantasmas de Imagen , Transductores , Ultrasonografía Doppler , Ultrasonografía Doppler/métodos , Ultrasonografía Doppler/instrumentación , Velocidad del Flujo Sanguíneo/fisiología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Análisis de Falla de Equipo
3.
Cardiovasc Intervent Radiol ; 47(3): 354-359, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38153421

RESUMEN

PURPOSE: To analyze the effectiveness of type II endoleaks (T2E) embolization using intra-operative contrast-enhanced ultrasound (CEUS). METHODS: Consecutive patients treated for T2E underwent a standardized protocol with trans-arterial or trans-lumbar access, large volume embolization, onlay fusion, and intra-operative CEUS. Technical success was defined by exclusion of endoleak by CEUS. RESULTS: Twenty-six patients (mean age 81 ± 11 years old; 89% male) were treated. The mean aneurysm sac enlargement was 11 ± 8 mm from T2E diagnosis. Embolization was performed using Onyx® 18 in all patients with adjunctive coils in 13 patients (50%). After the first embolization, CEUS documented residual T2E in 13 patients (50%). Ten patients (38%) had additional embolization, which successfully eradicated the T2E in seven of them. Technical success was 50% after the first embolization attempt and 77% after additional attempts guided by CEUS (P = 0.080). There was no mortality. Median imaging follow-up was 22 months. Among the 20 patients with no residual T2E on completion CEUS, 16 (80%) had sac stabilization and none required additional interventions for T2E. Of the six patients with residual T2Es on CEUS, three had sac stabilization (50%) and one required additional reintervention for T2E. There was one late aortic rupture at 56 months. CONCLUSION: One in two patients treated by T2E embolization had residual endoleak on intra-operative CEUS after a first embolization attempt, decreasing to one in four patients after multiple attempts. A negative completion CEUS following embolization was associated with higher rates of sac stabilization and no need for additional T2E embolization.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Endofuga/diagnóstico por imagen , Endofuga/terapia , Factores de Riesgo , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/efectos adversos , Embolización Terapéutica/efectos adversos , Estudios Retrospectivos
4.
J Vasc Surg Cases Innov Tech ; 9(4): 101339, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37965112

RESUMEN

We describe a case of an abdominal aortic aneurysm (AAA) and angulated proximal neck treated with a Gore Excluder conformable endoprosthesis and show relevant technical pitfalls in the deployment of the graft main body. An 82-year-old man presented with a 71-mm asymptomatic AAA with an angulated infrarenal proximal neck (75°) and was referred to our unit. The patient was treated with a 26-mm Gore Excluder conformable device, which was deployed slightly above the renal arteries after precatheterization of the lowest renal artery. The graft was then repositioned with support of the introducer sheath and a stiff guide wire. The proximal sealing zone was ballooned before the endograft delivery system was retrieved to avoid distal migration. Technical success was achieved. The patient was discharged with no complications. No type Ia endoleak was present on the 6-month computed tomography scan. Endovascular treatment of an AAA with a severe angulated proximal neck can be effective with a conformable stent graft if technical measures are used during deployment of the main body to optimize the seal.

5.
J Vasc Surg ; 78(5): 1162-1169.e2, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37453587

RESUMEN

OBJECTIVE: Stenting of renal and mesenteric vessels may result in changes in velocity measurements due to arterial compliance, potentially giving rise to confusion about the presence of stenosis during follow-up. The aim of our study was to compare preoperative and postoperative changes in peak systolic velocity (PSV, cm/s) after placement of the celiac axis (CA), superior mesenteric artery (SMA) and renal artery (RAs) bridging stent grafts during fenestrated-branched endovascular aortic repair (FB-EVAR) for treatment of complex abdominal aortic aneurysms (AAA) and thoracoabdominal aortic aneurysms. METHODS: Patients were enrolled in a prospective, nonrandomized single-center study to evaluate FB-EVAR for treatment of complex AAA and thoracoabdominal aortic aneurysms between 2013 and 2020. Duplex ultrasound examination of renal-mesenteric vessels were obtained prospectively preoperatively and at 6 to 8 weeks after the procedure. Duplex ultrasound examination was performed by a single vascular laboratory team using a predefined protocol including PSV measurements obtained with <60° angles. All renal-mesenteric vessels incorporated by bridging stent grafts using fenestrations or directional branches were analyzed. Target vessels with significant stenosis in the preoperative exam were excluded from the analysis. The end point was variations in PSV poststent placement at the origin, proximal, and mid segments of the target vessels for fenestrations and branches. RESULTS: There were 419 patients (292 male; mean age, 74 ± 8 years) treated by FB-EVAR with 1411 renal-mesenteric targeted vessels, including 260 CAs, 409 SMAs, and 742 RAs. No significant variances in the mean PSVs of all segments of the CA, SMA, and RAs at 6 to 8 weeks after surgery were found as compared with the preoperative values (CA, 135 cm/s vs 141 cm/s [P = .06]; SMA, 128 cm/s vs 125 cm/s [P = .62]; RAs, 90 cm/s vs 83 cm/s [P = .65]). Compared with baseline preoperative values, the PSV of the targeted vessels showed no significant differences in the origin and proximal segment of all vessels. However, the PSV increased significantly in the mid segment of all target vessels after stent placement. CONCLUSIONS: Stent placement in nonstenotic renal and mesenteric vessels during FB-EVAR is not associated with a significant increase in PSVs at the origin and proximal segments of the target vessels. Although there is a modest but significant increase in velocity measurements in the mid segment of the stented vessel, this difference is not clinically significant. Furthermore, PSVs in stented renal and mesenteric arteries were well below the threshold for significant stenosis in native vessels. These values provide a baseline or benchmark for expected PSVs after renal-mesenteric stenting during FB-EVAR.

6.
J Endovasc Ther ; : 15266028231163439, 2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-36995081

RESUMEN

PURPOSE: The Provisional Extension to Induce Complete Attachment Technique (PETTICOAT) uses a bare-metal stent to scaffold the true lumen in patients with acute or subacute aortic dissections. While it is designed to facilitate remodeling, some patients with chronic post-dissection thoracoabdominal aortic aneurysms (TAAAs) require repair. This study describes the technical pitfalls of fenestrated-branched endovascular aortic repair (FB-EVAR) in patients who underwent prior PETTICOAT repair. TECHNIQUE: We report 3 patients with extent II TAAAs who had prior bare-metal dissection stents treated by FB-EVAR. Two patients required maneuvers to reroute the aortic guidewire, which was initially placed in-between stent struts. This was recognized before the deployment of the fenestrated-branched device. A third patient had difficult advancement of the celiac bridging stent due to a conflict of the tip of the stent delivery system into one of the stent struts, requiring to redo catheterization and pre-stenting with a balloon-expandable stent. There were no mortalities and target-related events after a follow-up of 12 to 27 months. CONCLUSION: FB-EVAR following the PETTICOAT is infrequent, but technical difficulties should be recognized to prevent complications from the inadvertent deployment of the fenestrated-branched stent-graft component in-between stent struts. CLINICAL IMPACT: The present study highlights a few maneuvers to prevent or overcome possible complications during endovascular repair of chronic post-dissection thoracoabdominal aortic aneurysm following PETTICOAT. The main problem to be recognized is the placement of the aortic wire beyond one of the struts of the existing bare-metal stent. Moreover, encroachment of catheters or the bridging stent delivery system into the stent struts may potentially cause difficulties.

8.
Ann Surg ; 278(1): 140-147, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35801701

RESUMEN

OBJECTIVE: To assess the impact of secondary intervention (SI) on health-related quality of life (HR-QOL) after fenestrated-branched endovascular aortic repair (FB-EVAR) for complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. BACKGROUND: The effect of SI after FB-EVAR on physical and mental HR-QOL has not been described. METHODS: A cohort of 430 consecutive patients enrolled in a prospective, nonrandomized study to evaluate FB-EVAR (2013-2020) was assessed with 1325 short-form 36 HR-QOL questionnaires preoperatively and during follow-up visits. SIs were classified as major or minor procedures. Endpoints included patient survival, freedom from aortic-related mortality (ARM), freedom from SIs, and changes in HR-QOL physical component score (PCS) and mental component score. RESULTS: There were 302 male with mean age 74±8 years treated by FB-EVAR for 133 complex abdominal aortic aneurysms and 297 thoracoabdominal aortic aneurysms. After a mean follow up of 26±20 months, 97 patients (23%) required 137 SIs. At 5 years, freedom from any SI was 64%±4%, including freedom from minor SIs of 77%±4% and major SIs of 87%±3%. There was no difference in patient survival and freedom from ARM at same interval. On adjusted analysis, minor SIs correlated with improved survival. SIs had a negative correlation with PCS ( r =-0.8). There were no significant changes in mental component score with SIs. Predictors for SIs were fluoroscopy time, graft design, and aneurysm sac change. CONCLUSION: SIs were needed in nearly 1 out of 4 patients treated by FB-EVAR with no effect on patient survival or ARM. SI resulted in decline in PCS.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Aneurisma de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Torácica/cirugía , Calidad de Vida , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Factores de Riesgo , Procedimientos Endovasculares/métodos , Aneurisma de la Aorta Abdominal/cirugía , Estudios Retrospectivos
9.
Cardiovasc Intervent Radiol ; 46(2): 249-254, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36319711

RESUMEN

OBJECTIVE: To describe the feasibility and outcomes of endovascular repair of distal aortic arch aneurysms using a patient-specific stent graft with a pre-loaded single retrograde left subclavian artery (LSA) branch stent graft. METHODS: We reviewed the clinical data and outcomes of consecutive patients enrolled in an ongoing prospective, non-randomized physician-sponsored investigational device exemption study to evaluate the outcomes of endovascular aortic arch repair using patient-specific arch branch stent grafts (William Cook Europe, Bjaeverskov, Denmark) between 2019 and 2022. All patients received a design with triple-wide scallop and a single retrograde LSA branch with a pre-loaded catheter. RESULTS: There were five male patients with median age of 77 years old (72-80) treated using the single LSA branch stent graft. Technical success was achieved in all patients. Median operating time, fluoroscopy time, and total radiation dose area product were 103 (78-134) minutes, 26 (19-39) minutes, and 123 (71-270) mGy.cm2, respectively. There were no 30-day or in-hospital mortality, neurological or other major adverse events (MAEs). During median follow-up of 21 (20-27) months, all patients were alive with patent LSA branches, except for one who died of COVID-19 complications. There was no branch instability or secondary interventions. CONCLUSION: This early feasibility study demonstrates successful endovascular repair of distal aortic arch aneurysms using a patient-specific stent graft with single retrograde LSA branch without technical failures, mortality or neurological events. Larger clinical experience and longer follow-up are needed to determined effectiveness of this approach in patients who need endovascular repair with proximal extension into Zone 2.


Asunto(s)
Aneurisma del Arco Aórtico , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , COVID-19 , Procedimientos Endovasculares , Anciano , Humanos , Masculino , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Estudios de Factibilidad , Estudios Prospectivos , Diseño de Prótesis , Stents/efectos adversos , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Factores de Tiempo , Resultado del Tratamiento
10.
JACC Case Rep ; 4(24): 101680, 2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36438890

RESUMEN

Endovascular repair has been introduced to decrease the morbidity and mortality associated with open surgical repair of aortic arch pathology. We illustrate total percutaneous transfemoral approach with a 3-vessel inner branch stent-graft to treat aortic arch aneurysm. (Level of Difficulty: Advanced.).

14.
Cardiovasc Intervent Radiol ; 45(10): 1451-1461, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36050563

RESUMEN

PURPOSE: To assess technical aspects and outcomes of fenestrated-branched endovascular aortic repair (FB-EVAR) using a femoral-to-brachial (FTB) preloaded delivery system (PDS) with two separate configurations. METHODS: Clinical data of all consecutive patients enrolled in a prospective study to evaluate FB-EVAR for complex abdominal and thoracoabdominal aortic aneurysms (CAAAs & TAAA) between 2013 and 2020 were reviewed. Patients treated with FTB-PDS were included. The two configurations included 4 trans-brachial preloaded wires (4BR) or 2 trans-brachial and 2 transfemoral preloaded wires (2BR-2FE). Outcome measures included technical success, procedural metrics, 30-day or in-hospital mortality, major adverse events (MAEs), and target-vessel outcomes. RESULTS: There were 115 patients with a mean age of 73.8 ± 8 years, treated with FTB-PDS. Of these, 62 patients (54%) had 4BR and 53 patients (46%) had 2BR-2FE FTB-PDS. There were 106 TAAA (92%) and 9 CAAAs (8%). Technical success, defined as successful implantation of the stent-graft and all intended target-vessel stents without type I or III endoleak, was 97%, with no differences in total operating time, endovascular time, and radiation dose between groups. There were 3 deaths (3%) at 30 days. MAEs were noticed in 21 patients (18%) with no difference between groups, including new-onset dialysis (2% vs. 4%, P = 0.59), and paraplegia (7% vs. 11%, P = 0.51), for 4BR and 2BR-2FE, respectively. Patient survival and freedom from aortic-related mortality at 2-years were 79 ± 5% and 97 ± 1.7%, respectively, with no difference between groups. CONCLUSION: The use of FTB-PDS for FB-EVAR is safe with high technical success and a reasonable rate of MAEs. Each configuration provides specific benefits based on patient anatomy, while having similar procedural metrics and clinical outcomes.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/etiología , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Prospectivos , Diseño de Prótesis , Stents , Resultado del Tratamiento
15.
J Thromb Thrombolysis ; 54(3): 492-499, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35932383

RESUMEN

BACKGROUND: Popliteal cysts (PC) result from distension of the gastrocnemio-semimembranosous bursa. Published reports indicate coincident PC and deep vein thrombosis (DVT). Whether the presence of PC increase the risk of deep vein thrombosis (DVT) remains unclear. METHODS: Lower extremity venous Duplex ultrasound (DUS) reports were evaluated across the Mayo Clinic Enterprise (Rochester, Minnesota, Jacksonville, Florida, Scottsdale, Arizona, and the Mayo Clinic Health System) in patients ≥ 18 years of age. Natural language processing (NLP) algorithms were created and validated to identify acute lower extremity DVT and PC from these reports. To determine whether there is a link between PC and lower extremity DVT, the frequency of PC among cases (ultrasounds with acute DVT) were compared to controls (ultrasounds without acute DVT). RESULTS: A total of 357,703 lower extremities venous DUS were performed in 237,052 patients (mean age 63.3 ± 16.6, 54.4% were female) between 1992 and 2021. Acute DVT was identified in 32,572 (9.1%) DUS, and PC in 32,448 (9.1%). PC were seen in a lower frequency (8.0%) of ultrasounds with acute DVT than those without (9.2%) acute DVT (OR: 0.85, 95% CI: 0.82 to 0.89, p < 0.001). In a multivariate logistic regression model after adjusting for age, sex, and race, PCs were not positively associated with acute DVT (adjusted OR: 0.84, 95% CI: 0.81 to 0.88). CONCLUSIONS: PC are an incidental finding or an alternative diagnosis on lower extremity venous DUS, a finding that increases significantly with age. PC were not a risk factor in the development of lower extremity DVT.


Asunto(s)
Quiste Poplíteo , Trombosis de la Vena , Enfermedad Aguda , Femenino , Humanos , Extremidad Inferior/irrigación sanguínea , Masculino , Quiste Poplíteo/complicaciones , Quiste Poplíteo/diagnóstico por imagen , Vena Poplítea/diagnóstico por imagen , Estudios Retrospectivos , Factores de Riesgo , Ultrasonografía Doppler Dúplex , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/epidemiología
17.
J Vasc Surg ; 76(1): 79-87.e4, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35181519

RESUMEN

OBJECTIVE: Target artery (TA) instability has been the most frequent indication for secondary intervention after fenestrated and branched endovascular aortic repair (FB-EVAR) of pararenal and thoracoabdominal aortic aneurysms (TAAAs). The aim of the present study was to evaluate the effect of the gap distance between the endograft reinforced fenestration and TA origin at the aortic wall (fenestration gap [FG]) on target-related outcomes after FB-EVAR. METHODS: The clinical data and imaging studies of 430 patients enrolled in a prospective, nonrandomized study to evaluate FB-EVAR using manufactured stent grafts were reviewed. Of the 430 patients, 340 (79%) had had more than one vessel incorporated by fenestration. The FG was retrospectively measured on postoperative imaging studies and classified into three groups: no gap (FG, 0 mm), FG 1 to 4 mm, and FG ≥5 mm. The primary outcome was freedom from TA instability. The secondary end points included TA-related endoleak, TA secondary intervention, and TA patency. RESULTS: A total of 1558 renal-mesenteric TAs were incorporated by 1104 reinforced fenestrations and 454 directional branches (DBs), with a mean of 3.9 ± 0.5 vessels per patient. The mean FG was 2.8 ± 4.5 mm, with an FG of 0 mm for 646 TAs, 1 to 4 mm for 209 TAs, and ≥5 mm for 249 TAs. An FG of ≥5 mm was associated with significantly lower (P < .001) freedom from TA instability, type Ic or IIIc endoleak, and secondary interventions at 5 years. Compared with DBs, fenestrations with an FG of ≥5 mm had similar primary patency and freedom from TA instability but significantly lower freedom from type Ic or IIIc endoleak (91% ± 2% vs 95% ± 1%; log rank, P = .02) and secondary interventions (87% ± 3% vs 93% ± 2%; log-rank, P = .02) at 5 years. The independent predictors of TA instability included postdissection TAAAs (hazard ratio, 2.5; 95% confidence interval, 1.2-5.4) and FG ≥5 mm (hazard ratio, 1.6; 95% confidence interval, 1.2-1.8). TAs incorporated by reinforced fenestrations had higher primary (99% ± 0.8% vs 97% ± 1.0%; P = .039) and secondary (100% vs 98% ± 1.0%; P = .012) patency rates at 5 years compared with DBs, with the lowest primary patency observed for renal DBs (80% ± 6% vs 92% ± 2%; P = .008). CONCLUSIONS: An FG of ≥5 mm was independently associated with an increased risk of TA instability, type Ic or IIIc endoleaks, and secondary interventions for patients treated by FB-EVAR using fenestrated designs. TAs incorporated by DBs had lower 5-year primary and secondary patency compared with those with reinforced fenestrations, with the lowest 5-year patency of 80% for renal branches. Compared with DBs, fenestrations with an FG of ≥5 mm carried a greater risk of type Ic or IIIc endoleak and secondary interventions. Independent predictors of TA instability included postdissection TAAAs and a greater FG. In contrast, dual antiplatelet therapy and larger TA diameters were protective.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Arterias/cirugía , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Humanos , Estudios Prospectivos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
19.
J Vasc Surg ; 75(3): 783-793.e4, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34742884

RESUMEN

OBJECTIVE: To evaluate the incidence of intraoperative adverse events (IAEs) and their impact on outcomes after fenestrated-branched endovascular aortic repair (FB-EVAR) of complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysm (TAAAs). METHODS: We reviewed the clinical and imaging data of 600 consecutive patients (445 males; mean age, 75 ± 8 years) who underwent FB-EVAR between 2007 and 2019 in a single institution. IAE was defined as any intraoperative complication or technical problem requiring additional and unplanned procedures, and was classified as access-related, target artery (TA)-related, or graft-related. End points included rates of IAEs, 30-day or in-hospital mortality, major adverse events, patient survival, freedom from secondary intervention, and TA instability. RESULTS: A total of 122 IAEs were identified in 105 patients (18%). IAEs were TA-related in 55 patients (9%), access-related in 46 patients (8%), and graft-related in seven patients (1%). Female sex was more frequent among patients with IAEs (44% vs 22%; P < .001). Patients with IAEs had smaller renal artery diameter (-0.4 mm, 5.4 ± 0.8 mm vs 5.8 ± 0.9 mm; P < .001), and were treated more often for TAAAs (72% vs 54%; P < .03). Technical success was achieved in 96.5% of patients and was lower for patients with IAEs (82% vs 99%; P < .001). Major adverse events were significantly more frequent among patients who had IAEs (odds ratio [OR], 1.98; 95% confidence interval [CI], 1.21-3.25), most due to acute kidney injury (27% vs 11%; P < .001) including new-onset dialysis (5% vs 1%; P = .01). On multivariate logistic regression model, female sex (OR, 2.5; 95% CI, 1.5-4.0), TA stenosis >50% (OR, 2.0; 95% CI, 1.3-3.3), and Crawford Extent II TAAA (OR, 1.9; 95% CI, 1.1-3.3) were predictive of IAEs, whereas preloaded design (OR, 0.6; 95% CI, 0.4-0.9) and TA diameter (+1 mm; OR, 0.6; 95% CI, 0.4-0.9) were protective of IAEs. IAEs negatively affected secondary intervention (hazard ratio [HR], 1.6; 95% CI, 1.1-2.3) and TA instability (HR, 2.5; 95% CI, 1.2-5.4); however, IAEs did not affect patient survival (HR, 1.0; 95% CI, 0.7-1.4). CONCLUSIONS: IAEs are common, occurring in nearly one of five patients treated with FB-EVAR for complex aortic aneurysms, and have a negative impact on clinical outcomes. IAEs were associated with female sex, TA diameter, and more extensive aortic disease.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Complicaciones Posoperatorias/epidemiología , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
20.
Ann Surg ; 274(3): 491-499, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34132698

RESUMEN

OBJECTIVE: The aim of this study was to investigate the midterm outcomes of fenestrated and branched endovascular aortic repair (FB-EVAR) of pararenal (PRA) and thoracoabdominal aortic aneurysms (TAAAs). SUMMARY BACKGROUND DATA: FB-EVAR has been associated with decreased morbidity compared to open repair, but there is limited midterm data. METHODS: A total of 430 patients (302 males, mean age 74 ±â€Š8 years) treated by FB-EVAR were enrolled in a prospective, nonrandomized investigational device exemption study. Endpoints included 30-day mortality and major adverse events (MAEs), freedom from all cause and aortic-related mortality, target vessel patency, and freedom from secondary intervention and target vessel instability. RESULTS: There were 133 PRAs and 297 TAAAs with 1673 renal-mesenteric arteries incorporated by fenestrations or directional branches (3.9 ±â€Š0.5 vessels/patient). At 30 days or within the hospital stay if longer than 30 days, there were 4 (0.9%) deaths. MAEs included new-onset dialysis in 8 patients (2%), permanent paraplegia or stroke in 10 patients each (2%), and respiratory failure requiring tracheostomy in 2 patients (0.5%). After a mean follow-up of 26 ±â€Š20 months, there were 3 (0.7%) aortic-related deaths from SMA stent occlusion, gastrointestinal hemorrhage, or complications of open arch repair. At 5 years, freedom from all-cause and aortic-related mortality were 57% ±â€Š5% and 98% ±â€Š1%, respectively. Freedom from secondary intervention was 64% ±â€Š4%, primary target vessel patency was 94% ±â€Š1%, and freedom from target vessel instability was 89% ±â€Š2% at same interval. One patient (0.2%) had nonfatal aneurysm treated using endovascular repair. CONCLUSION: FB-EVAR is safe and effective for treatment of PRA and TAAAs with low rate of aortic-related mortality and aneurysm rupture on midterm follow-up.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Procedimientos Endovasculares , Anciano , Aneurisma de la Aorta Torácica/mortalidad , Femenino , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Reoperación/estadística & datos numéricos , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA