Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros




Intervalo de año de publicación
1.
Rev Soc Bras Med Trop ; 53: e20200314, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32997053

RESUMEN

INTRODUCTION: Rapid and accurate tuberculosis detection is critical for improving patient diagnosis and decreasing tuberculosis transmission. Molecular assays can significantly increase laboratory costs; therefore, the average time and economic impact should be evaluated before implementing a new technology. The aim of this study was to evaluate the cost and average turnaround time of smear microscopy and Xpert assay at a university hospital. METHODS: The turnaround time and cost of the laboratory diagnosis of tuberculosis were calculated based on the mean cost and activity based costing (ABC). RESULTS: The average turnaround time for smear microscopy was 16.6 hours while that for Xpert was 24.1 hours. The Xpert had a mean cost of USD 17.37 with an ABC of USD 10.86, while smear microscopy had a mean cost of USD 13.31 with an ABC of USD 6.01. The sensitivity of smear microscopy was 42.9% and its specificity was 99.1%, while the Xpert assay had a sensitivity of 100% and a specificity of 96.7%. CONCLUSIONS: The Xpert assay has high accuracy; however, the turnaround time and cost of smear microscopy were lower than those of Xpert.


Asunto(s)
Bioensayo/economía , Patología Molecular/economía , Tuberculosis Pulmonar/diagnóstico , Bioensayo/métodos , Costos y Análisis de Costo , Humanos , Microscopía , Mycobacterium tuberculosis , Patología Molecular/métodos , Sensibilidad y Especificidad , Tuberculosis , Tuberculosis Pulmonar/economía
2.
Rev. Soc. Bras. Med. Trop ; 53: e20200314, 2020. tab, graf
Artículo en Inglés | SES-SP, ColecionaSUS, LILACS | ID: biblio-1136805

RESUMEN

Abstract INTRODUCTION: Rapid and accurate tuberculosis detection is critical for improving patient diagnosis and decreasing tuberculosis transmission. Molecular assays can significantly increase laboratory costs; therefore, the average time and economic impact should be evaluated before implementing a new technology. The aim of this study was to evaluate the cost and average turnaround time of smear microscopy and Xpert assay at a university hospital. METHODS: The turnaround time and cost of the laboratory diagnosis of tuberculosis were calculated based on the mean cost and activity based costing (ABC). RESULTS: The average turnaround time for smear microscopy was 16.6 hours while that for Xpert was 24.1 hours. The Xpert had a mean cost of USD 17.37 with an ABC of USD 10.86, while smear microscopy had a mean cost of USD 13.31 with an ABC of USD 6.01. The sensitivity of smear microscopy was 42.9% and its specificity was 99.1%, while the Xpert assay had a sensitivity of 100% and a specificity of 96.7%. CONCLUSIONS: The Xpert assay has high accuracy; however, the turnaround time and cost of smear microscopy were lower than those of Xpert.


Asunto(s)
Humanos , Tuberculosis Pulmonar/diagnóstico , Bioensayo/economía , Patología Molecular/economía , Tuberculosis , Tuberculosis Pulmonar/economía , Bioensayo/métodos , Sensibilidad y Especificidad , Costos y Análisis de Costo , Patología Molecular/métodos , Microscopía , Mycobacterium tuberculosis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA