RESUMEN
The mechanical properties of the sclera play a critical role in supporting the ocular structure and maintaining its shape. However, non-invasive measurements to quantify scleral biomechanics remain challenging. Recently introduced multi-directional optical coherence elastography (OCE) combined with an air-coupled ultrasound transducer for excitation of elastic surface waves was used to estimate phase speed and shear modulus in ex vivo rabbit globes (n = 7). The scleral phase speed (12.1 ± 3.2 m/s) was directional-dependent and higher than for corneal tissue (5.9 ± 1.4 m/s). In the tested locations, the sclera proved to be more anisotropic than the cornea by a factor of 11 in the maximum of modified planar anisotropy coefficient. The scleral shear moduli, estimated using a modified Rayleigh-Lamb wave model, showed significantly higher values in the circumferential direction (65.4 ± 31.9 kPa) than in meridional (22.5 ± 7.2 kPa); and in the anterior zone (27.3 ± 9.3 kPa) than in the posterior zone (17.8 ± 7.4 kPa). The multi-directional scanning approach allowed both quantification and radial mapping of estimated parameters within a single measurement. The results indicate that multi-directional OCE provides a valuable non-invasive assessment of scleral tissue properties that may be useful in the development of improved ocular models, the evaluation of potential myopia treatment strategies, and disease characterization and monitoring.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Esclerótica , Tomografía de Coherencia Óptica , Animales , Conejos , Esclerótica/diagnóstico por imagen , Esclerótica/fisiología , Diagnóstico por Imagen de Elasticidad/métodos , Tomografía de Coherencia Óptica/métodos , Fenómenos Biomecánicos , Córnea/diagnóstico por imagen , Córnea/fisiología , Módulo de ElasticidadRESUMEN
Silk fibroin (SF) extracted from silkworm silk can be transformed into transparent membranes with well-suited physical properties for ophthalmic applications. There is ample literature on the fabrication and characterization of SF-based membranes; however, the use of diverse SF extraction protocols and characterization methods or their settings makes it difficult to compare different silk membrane properties across studies. In this work, we fabricated 10 families of SF-based membranes by physical cross-linking and one non-cross-linked as a control. We evaluated transparency (ranging from 84.5 to 95.3% in the visible spectrum), enzyme stability (from 24 h to 200 days in protease XIV), decomposition temperature (280-290 °C), water uptake (40-60%), Young's modulus (8-30 MPa), roughness (1.6-22.7 nm), and FTIR spectra for the secondary structure. We found correlation between water uptake and the Young's modulus (the lower the water uptake, the higher the Young's modulus) and a relationship between membrane stability in protease XIV and the secondary structure of the proteins. Higher surface roughness and faster degradation were found in membranes cross-linked with polyethylene glycol, and conversely, lower roughness and lower degradation were found in methanol, ethanol, or isopropanol crossed-link membranes. This ample compilation of materials and their characterization will aid in the selection of a SF-based material according to the needs of the application.
RESUMEN
Introduction: The mechanical properties of the sclera are related to its structural function, and changes to these properties are believed to contribute to pathologies such as myopia. Air-puff deformation imaging is a tool that uses an imaging system coupled with an air-puff excitation source to induce and measure deformation in a tissue in vivo. Typically used for the study of the cornea's mechanical properties and IOP, this tool has been proposed as a method to evaluate scleral stiffness. Methods: In this work, we present a computational model of the rabbit eye to assess scleral deformation under air-puff. Parametric studies were conducted to evaluate the effects of material properties, intraocular pressure, and other parameters on the deformation response. Output from the model was also compared to experimental measurements of air-puff deformation in rabbit eyes under varying IOP. Results: Central deformation response was found to be most influenced by material properties of the sclera (at site of air-puff and posterior), thickness, and IOP, whereas deformation profile was most influenced by material properties. Experimental and simulated IOP dependence were found to be similar (RMSE = 0.13 mm). Discussion: Scleral APDI could be a useful tool for quick in vivo assessment of scleral stiffness.
RESUMEN
Purpose: The purpose of this study was to evaluate the biomechanical and hydration differences in scleral tissue after two modalities of collagen cross-linking. Methods: Scleral tissue from 40 adult white rabbit eyes was crosslinked by application of 0.1% Rose Bengal solution followed by 80 J/cm2 green light irradiation (RGX) or by application of 0.1% riboflavin solution followed by 5.4 J/cm2 ultraviolet A irradiation (UVX). Posterior scleral strips were excised from treated and untreated sclera for tensile and hydration-tensile tests. For tensile tests, the strips were subjected to uniaxial extension after excision. For hydration-tensile tests, the strips were dehydrated, rehydrated, and then tested. Young's modulus at 8% strain and swelling rate were estimated. ANOVAs were used to test treated-induced differences in scleral biomechanical and hydration properties. Results: Photo-crosslinked sclera tissue was stiffer (Young's modulus at 8% strain: 10.7 ± 4.5 MPa, on average across treatments) than untreated scleral tissue (7.1 ± 4.0 MPa). Scleral stiffness increased 132% after RGX and 90% after UVX compared to untreated sclera. Scleral swelling rate was reduced by 11% after RGX and by 13% after UVX. The stiffness of the treated sclera was also associated with the tissue hydration level. The lower the swelling, the higher the Young's modulus of RGX (-3.8% swelling/MPa) and UVX (-3.5% swelling/MPa) treated sclera. Conclusions: Cross-linking with RGX and UVX impacted the stiffness and hydration of rabbit posterior sclera. The Rose Bengal with green light irradiation may be an alternative method to determine the efficacy and suitability of inducing scleral tissue stiffening in the treatment of myopia.
Asunto(s)
Reactivos de Enlaces Cruzados , Fármacos Fotosensibilizantes , Riboflavina , Rosa Bengala , Esclerótica , Rayos Ultravioleta , Animales , Conejos , Reactivos de Enlaces Cruzados/farmacología , Fármacos Fotosensibilizantes/farmacología , Riboflavina/farmacología , Rosa Bengala/farmacología , Resistencia a la Tracción , Fenómenos Biomecánicos , Módulo de Elasticidad , Colágeno/metabolismo , ElasticidadRESUMEN
Whole-eye optical coherence tomography (OCT) imaging is a promising tool in ocular biometry for cataract surgery planning, glaucoma diagnostics and myopia progression studies. However, conventional OCT systems are set up to perform either anterior or posterior eye segment scans and cannot easily switch between the two scan configurations without adding or exchanging optical components to account for the refraction of the eye's optics. Even in state-of-the-art whole-eye OCT systems, the scan configurations are pre-selected and cannot be dynamically reconfigured. In this work, we present the design, optimization and experimental validation of a reconfigurable and low-cost optical beam scanner based on three electro-tunable lenses, capable of non-mechanically controlling the beam position, angle and focus. We derive the analytical theory behind its control. We demonstrate its use in performing alternate anterior and posterior segment imaging by seamlessly switching between a telecentric focused beam scan to an angular collimated beam scan. We characterize the corresponding beam profiles and record whole-eye OCT images in a model eye and in an ex vivo rabbit eye, observing features comparable to those obtained with conventional anterior and posterior OCT scanners. The proposed beam scanner reduces the complexity and cost of other whole-eye scanners and is well suited for 2-D ocular biometry. Additionally, with the added versatility of seamless scan reconfiguration, its use can be easily expanded to other ophthalmic applications and beyond.
RESUMEN
Quantifying human crystalline lens geometry as a function of age and accommodation is important for improved cataract and presbyopia treatments. In previous works we presented eigenlenses as a basis of 3-D functions to represent the full shape of the crystalline lens ex vivo. Also, we presented the application of eigenlenses to estimate the full shape of the lens in vivo from 3-D optical coherence tomography (OCT) images, where only the central part of the lens -visible through the pupil- is available. The current work presents a validation of the use of eigenlenses to estimate in vivo the full shape of dis-accommodated lenses. We used 14 ex vivo crystalline lenses from donor eyes (11-54 y/o) mounted in a lens stretcher, and measured the geometry and the power of the lenses using a combined OCT and ray tracing aberrometry system. Ex vivo, the full extent of the lens is accessible from OCT because the incident light is not blocked by the iris. We measured in non-stretched (fully accommodated) and stretched (mimicking in vivo dis-accommodated lenses) conditions. Then, we simulated computationally in vivo conditions on the obtained ex vivo lenses geometry (assuming that just the portion of the lens within a given pupil is available), and estimated the full shape using eigenlenses. The mean absolute error (MAE) between estimated and measured lens' diameters and volumes were MAE = 0.26 ± 0.18 mm and MAE = 7.0 ± 4.5 mm3, respectively. Furthermore, we concluded that the estimation error between measured and estimated lenses did not depend on the accommodative state (change in power due to stretching), and thus eigenlenses are also useful for the full shape estimation of in vivo dis-accommodated lenses.
RESUMEN
Scleral biomechanics plays a key role in the understanding of myopia progression. In this study, we characterized the elastic properties of sclera using an air-coupled ultrasonic (ACUS) optical coherence elastography (OCE) system. New Zealand rabbit eyes (n=7) were measured (<24hr postmortem) in four scleral locations: superior/inferior temporal (ST, IT), and superior/inferior nasal (SN, IN) maintaining an intraocular pressure of 15 mmHg. Elastic waves were induced in the sclera, and wave propagation velocity and shear modulus were measured along two directions: circumferential (superior-inferior) and meridional (nasal-temporal). Wave velocity in scleral tissue ranged from 6 to 24 m/s and shear modulus from 11 to 150 kPa. Velocity was significantly higher (p<.001) in the circumferential vs. meridional directions in the following locations: ST:15.83±2.85 vs 9.43±1.68 m/s, IT:15.00±3.98 vs 8.93±1.53 m/s; SN:16.79±4.30 vs 9.27±1.47 m/s; and IN:13.92±3.85 vs 8.57±1.46 m/s. The average shear modulus in the circumferential was also significantly higher (p<.001) than in the meridional direction for all locations: 65.37±6.04 vs 22.55±1.36 kPa. These results show that the rabbit sclera is mechanically anisotropic with higher rigidity in the circumferential direction compared to the meridional direction. ACUS-OCE is a promising non-invasive method to quantify the biomechanical changes in scleral tissue for future studies involving myopia treatments.
Asunto(s)
Diagnóstico por Imagen de Elasticidad , Meridianos , Miopía , Animales , Conejos , Ultrasonido , Esclerótica/diagnóstico por imagen , Anisotropía , Miopía/diagnóstico por imagenRESUMEN
Progression of myopia is usually accompanied by axial overgrowth of the eyeball, which affects scleral biomechanics (BM). To study scleral biomechanics, we propose the use of air-puff deformation swept-source OCT imaging. Air-puff deformation imaging was performed at different sites of ex vivo porcine (n=5) and rabbit (n=3) eyes, (<24hr postmortem): Nasal/temporal equatorial and posterior sclera (NE, NP, TE, TP), superior (S) and inferior (I) sclera, and cornea (C). Intraocular pressure was kept at 15mmHg. Deformation data were used as input to inverse finite element model (FEM) algorithms to reconstruct BM properties. Experimental deformation amplitudes showed dependence on the animal model, with porcine scleras exhibiting greater inter-site variation (displacement of S, I was up to four times greater than that of N, T), while rabbit scleras exhibited at most 40% of displacement differences between all sites. Both models showed significant (p<.001) differences in the temporal deformation profile between sclera and (C), but similarities in all scleral locations, suggesting that the scleral temporal profile is independent of scleral thickness variations. The FEM estimated an elastic modulus of 1.84 ± 0.30 MPa (I) to 6.04 ± 2.11 MPa (TE) for the porcine sclera. The use of scleral air-puff imaging is promising for noninvasive investigation of structural changes in the sclera associated with myopia and for monitoring possible modulation of scleral stiffness with myopia treatment.
Asunto(s)
Miopía , Tomografía de Coherencia Óptica , Animales , Conejos , Porcinos , Esclerótica/diagnóstico por imagen , Algoritmos , Fenómenos Biomecánicos , Miopía/diagnóstico por imagenRESUMEN
Purpose: The mechanical properties of the crystalline lens are related to its optical function of accommodation, and their changes with age are one of the potential causes for presbyopia. We estimated the mechanical parameters of the crystalline lens using quantitative optical coherence tomography (OCT) imaging and wavefront sensing data from accommodating participants and computer modeling. Methods: Full-lens shape data (from quantitative swept-source OCT and eigenlens representation) and optical power data (from Hartmann-Shack wavefront sensor) were obtained from 11 participants (22-30 years old) for relaxed accommodation at infinity and -4.5 D accommodative demand. Finite element models of lens, capsular bag, zonulae, and ciliary body were constructed using measured lens geometry and literature data, assuming a 60-mN radial force. An inverse modeling scheme was used to determine the shear moduli of the nucleus and cortex of the lens, such that the simulated deformed (maximally stretched) lens matched the participant's lens at -4.5 D. Results: The shear moduli of the nucleus and cortex were 1.62 ± 1.32 and 8.18 ± 5.63 kPa, on average, respectively. The shear modulus of the nucleus was lower than that of the cortex for all participants evaluated. The average of the two moduli per participant was statistically significantly correlated with age (R2 = 0.76, P = 0.0049). Conclusions: In vivo imaging and mechanical modeling of the crystalline lens allow estimations of the crystalline lens' mechanical properties. Differences between nuclear and cortical moduli and their dependency with age appear to be critical in accommodative function and likely in its impairment in presbyopia.
Asunto(s)
Acomodación Ocular , Cristalino , Tomografía de Coherencia Óptica , Humanos , Masculino , Femenino , Cristalino/diagnóstico por imagen , Análisis de Elementos Finitos , Presbiopía , Tomografía de Coherencia Óptica/métodos , Simulación por Computador , Voluntarios Sanos , AdultoRESUMEN
PURPOSE: To evaluate computationally the optical performance of AcrySof IQ Vivity extended depth-of-focus (EDOF) intraocular lenses (IOLs) in post-laser in situ keratomileusis (LASIK) eyes. SETTING: Visual Optics and Biophotonics Laboratory, Madrid, Spain. DESIGN: Experimental study. METHODS: Computer pseudophakic eye models were implemented using reported post-LASIK corneal aberrations (refractive corrections from -7.5 to +4.5 diopters [D]) and virtually implanted with monofocal (AcrySof IQ) or EDOF (AcrySof IQ Vivity) IOLs. Retinal image quality was quantified through visual Strehl (VS). The depth of focus (DOF) was calculated from the through-focus VS curves. Halos were estimated from the light spread in the image of a pinhole. Those quantitative parameters were obtained for 5.0 and 3.0 mm pupil diameters. RESULTS: Simulated virgin eyes showed VS of 0.89/0.99 with monofocal IOLs and 0.74/0.52 with EDOF IOLs for 5.0/3.0 mm pupils at best focus. VS decreased with induced spherical aberration (SA) by 25% and with induced SA + coma by 61% on average (3.0 mm pupils). The DOF was 2.50 D in virgin eyes with EDOF IOLs, 1.66 ± 0.30 and 2.54 ± 0.31 D ( P < .05) on average in post-LASIK eyes for 3.0 mm pupils, monofocal and EDOF IOLs, respectively. Halos were more sensitive to SA induction for 5.0 mm pupils, and induction of positive SA (myopic LASIK) resulted in reduced halos with the EDOF when compared with the monofocal IOLs, by 1.62 (SA) and 1.86 arc min (SA + coma), on average. CONCLUSIONS: Computer post-LASIK pseudophakic eye models showed that the DOF was less dependent on the presence of SA and coma with EDOF IOLs and that halos were reduced with EDOF IOLs compared with the monofocal IOL for a range of SA.
Asunto(s)
Queratomileusis por Láser In Situ , Lentes Intraoculares , Humanos , Agudeza Visual , Coma , Visión Ocular , Diseño de PrótesisRESUMEN
The EphA2 receptor tyrosine kinase is overexpressed in most solid tumors and acts as the major driver of tumorigenesis. In this study, we developed a novel approach for targeting the EphA2 receptor using a 2'-fluoro-modified pyrimidine RNA aptamer termed ATOP. We identified the ATOP EphA2 aptamer using a novel bioinformatics strategy that compared aptamers enriched during a protein SELEX using recombinant human EphA2 and a cell-internalization SELEX using EphA2-expressing MDA231 tumor cells. When applied to EphA2-expressing tumor cell lines, the ATOP EphA2 aptamer attenuated tumor cell migration and clonogenicity. In a mouse model of spontaneous metastasis, the ATOP EphA2 aptamer slowed primary tumor growth and significantly reduced the number of lung metastases. The EphA2 ATOP aptamer represents a promising candidate for the development of next-generation targeted therapies that provide safer and more effective treatment of EphA2-overexpressing tumors.
RESUMEN
There is an increasing interest in applying optical coherence tomography (OCT) to quantify the topography of ocular structures. However, in its most usual configuration, OCT data is acquired sequentially while a beam is scanned through the region of interest, and the presence of fixational eye movements can affect the accuracy of the technique. Several scan patterns and motion correction algorithms have been proposed to minimize this effect, but there is no consensus on the ideal parameters to obtain a correct topography. We have acquired corneal OCT images with raster and radial patterns, and modeled the data acquisition in the presence of eye movements. The simulations replicate the experimental variability in shape (radius of curvature and Zernike polynomials), corneal power, astigmatism, and calculated wavefront aberrations. The variability of the Zernike modes is highly dependent on the scan pattern, with higher variability in the direction of the slow scan axis. The model can be a useful tool to design motion correction algorithms and to determine the variability with different scan patterns.
RESUMEN
The guest editors introduce a feature issue commemorating the 25th anniversary of adaptive optics in biomedical research.
RESUMEN
The development of optical sensors for in situ testing has become of great interest in the rapid diagnostics industry. We report here the development of simple, low-cost optical nanosensors for the semi-quantitative detection or naked-eye detection of tyramine (a biogenic amine whose production is commonly associated with food spoilage) when coupled to Au(III)/tectomer films deposited on polylactic acid (PLA) supports. Tectomers are two-dimensional oligoglycine self-assemblies, whose terminal amino groups enable both the immobilization of Au(III) and its adhesion to PLA. Upon exposure to tyramine, a non-enzymatic redox reaction takes place in which Au(III) in the tectomer matrix is reduced by tyramine to gold nanoparticles, whose reddish-purple color depends on the tyramine concentration and can be identified by measuring the RGB coordinates (Red-Green-Blue coordinates) using a smartphone color recognition app. Moreover, a more accurate quantification of tyramine in the range from 0.048 to 10 µM could be performed by measuring the reflectance of the sensing layers and the absorbance of the characteristic 550 nm plasmon band of the gold nanoparticles. The relative standard deviation (RSD) of the method was 4.2% (n = 5) with a limit of detection (LOD) of 0.014 µM. A remarkable selectivity was achieved for tyramine detection in the presence of other biogenic amines, especially histamine. This methodology, based on the optical properties of Au(III)/tectomer hybrid coatings, is promising for its application in food quality control and smart food packaging.
Asunto(s)
Oro , Nanopartículas del Metal , Tiramina , Aminas Biogénicas , Poliésteres , Colorimetría/métodosRESUMEN
Purpose: To propose new methods for eye selection in presbyopic monovision corrections. Methods: Twenty subjects with presbyopia performed two standard methods of binary eye dominance identification (sensory with +1.50 diopters [D ]and +0.50 D and sighting with "hole-in-the-card") and two psychophysical methods of perceived visual quality: (1) the Preferential test, 26 natural images were judged with the near addition in one eye or in the other in a 2-interval forced-choice task, and the Eye Dominance Strength (EDS) defined as the proportion of trials where one monovision is preferred over the other; (2) the Multifocal Acceptance Score (MAS-2EV) test, the perceived quality of a natural images set (for 2 luminance levels and distances) was scored and EDS defined as the score difference between monovision in one eye or the other. Left-eye and right-eye dominance are indicated with negative and positive values, respectively. Tests were performed using a Simultaneous Vision Simulator, which allows rapid changes between corrections. Results: Standard sensory and sighting dominances matched in only 55% of subjects. The Preferential EDS (ranging from -0.7 to +0.9) and MAS-2EV EDS (ranging from -0.6 to +0.4) were highly correlated. Selecting the eye for far in monovision with the MAS-2EV, sensory, or sighting tests would have resulted in 79%, 64%, and 43% success considering the Preferential test as the gold standard. Conclusions: Tests based on perceptual preference allow selection of the preferred monovision correction and measurement of dominance strength. Translational Relevance: The binocular visual simulator allows efficient implementation of eye preference tests for monovision in clinical use.
Asunto(s)
Predominio Ocular , Visión Monocular , Humanos , Agudeza Visual , Visión Ocular , Pruebas de VisiónRESUMEN
Quantifying the full 3-D shape of the human crystalline lens is important for improving intraocular lens power or sizing calculations in treatments of cataract and presbyopia. In a previous work we described a novel method for the representation of the full shape of the ex vivo crystalline lens called eigenlenses, which proved more compact and accurate than compared state-of-the art methods of crystalline lens shape quantification. Here we demonstrate the use of eigenlenses to estimate the full shape of the crystalline lens in vivo from optical coherence tomography images, where only the information visible through the pupil is available. We compare the performance of eigenlenses with previous methods of full crystalline lens shape estimation, and demonstrate an improvement in repeatability, robustness and use of computational resources. We found that eigenlenses can be used to describe efficiently the crystalline lens full shape changes with accommodation and refractive error.
RESUMEN
In situ enzymatic generation of bimetallic nanoparticles, mainly Au/Pt, overcomes the drawbacks (continuous absorbance drift, modest LOQ, and long-time reaction) observed when AuNP alone are produced. In this study, Au/Pt nanoparticles have been characterized by EDS, XPS, and HRTEM images using the enzymatic determination of tyramine with tyramine oxidase (TAO) as a model. Under experimental conditions, the Au/Pt NPs show an absorption maximum at 580 nm which can be related to the concentration of tyramine in the range 1.0 × 10-6M to 2.5 × 10-4M with a RSD of 3.4% (n = 5, using 5 × 10-6M tyramine). The Au/Pt system enables low LOQ (1.0 × 10-6 M), high reduction of the absorbance drift, and a significant shortening of the reaction time (i.e., from 30 to 2 min for a [tyramine] = 1 × 10-4M); additionally, a better selectivity is also obtained. The method has been applied to tyramine determination in cured cheese and no significant differences were obtained compared to a reference method (HRP:TMB). The effect of Pt(II) seems to involve the previous reduction of Au(III) to Au(I) and NP generation from this oxidation state. Finally, a three-step (nucleation-growth-aggregation) kinetic model for the generation of NPs is proposed; this has enabled us to obtain a mathematical equation which explains the experimentally observed variation of the absorbance with time.
RESUMEN
This work details the enzymatic generation of fluorescence nanomaterials and the use of this optical signal as the analytical parameter for the quantification of the substrate. More specifically, fluorescent copper nanoclusters have been obtained during the enzymatic reaction of tyramine oxidase and tyramine in the presence of Cu(II); the fluorescence intensity being proportional to the concentration of tyramine. The nanoclusters obtained show fluorescence at 445 nm by being excited at 320 nm and have been characterized by TEM, EDX, and XPS. The formation mechanism has also been studied, suggesting that under the optimal conditions (0.1 M MES buffer and pH = 6), the formation of the nanoclusters is due to the reducing properties of the product of the enzymatic reaction (p-hydroxybenzaldehyde) in MES buffer. The method shows a linear relationship with the concentration of tyramine in the range from 1.0·10-5 to 2.5·10-4 M, a RSD of 3% (n = 5) and a LOD of 6.3·10-6 M. The method has been applied to the determination of tyramine in sausage with good results.
Asunto(s)
Colorantes Fluorescentes , Nanopartículas del Metal , Cobre/química , Espectrometría de Fluorescencia/métodos , Tiramina/químicaRESUMEN
Tyramine oxidase (TAO), peroxidase (HRP), and Amplex Red (AR) have been immobilized on cellulose to obtain disposable biosensors for the determination of histamine. During the enzymatic reaction, AR is oxidized and a pink spot is obtained. Using a smartphone and measuring the G (green) color coordinate, histamine can be determined in the presence of other biogenic amines (putrescine and cadaverine) in concentrations ranging from 2·10-5 M to 5·10-4 M with a 7.5·10-6 M limit of detection (LoD). Despite tyramine interference, experimental conditions are provided which allow rapid and simple histamine and simultaneous histamine/tyramine (semi)quantitative determination in mixtures. Finally, tyramine and histamine were determined in a tuna extract with good results (compared to the reference HPLC-MS method). The methodology can also be applied in solution allowing histamine (and simultaneous histamine/tyramine) determination with a lower LoD (1.8·10-7 M) and a similar selectivity.
Asunto(s)
Técnicas Biosensibles , Histamina , Tiramina , Colorimetría/métodos , Teléfono Inteligente , Aminas Biogénicas , Técnicas Biosensibles/métodosRESUMEN
PURPOSE: To study the viability of visual simulation of presbyopic correction in patients with cataract and the effect and impact of the cataract on the perceived visual quality of the different simulated presbyopic corrections preoperatively and postoperatively. SETTING: San Carlos Clinical Hospital, Madrid, Spain. DESIGN: Observational, noninterventional, pilot study, early feasibility of the device being studied. METHODS: Cataract patients were tested preoperatively (n = 24) and postoperatively (n = 15) after bilateral implantation of monofocal intraocular lenses (IOLs). The degree of cataract was evaluated objectively with the objective scatter index (OSI). Visual acuity (VA) and perceived visual quality of natural scene images (Multifocal Acceptance Score) were measured before and after cataract surgery at far (4 m), intermediate (64 cm) and near distance (40 cm) with 4 binocular presbyopic corrections (single vision, bifocal, monovision and modified-monovision) simulated with a binocular Simultaneous Vision simulator based on temporal multiplexing. RESULTS: VA was significantly correlated with OSI ( r = -0.71, P < .0005), although the visual degradation at far for each correction was constant and not correlated with OSI. The visual benefit at near distance provided by the presbyopic correction was noticeable (23.3% ± 27.6% across corrections) for OSI <5. The individual perceptual scores were highly correlated preoperatively vs postoperatively ( r = 0.64, P < .0005) for all corrections and distances. CONCLUSIONS: Visual simulations of IOLs are an excellent tool to explore prospective postoperative vision. The high correlation in the perceptual scores pre- and post-cataract surgery demonstrates that SimVis Gekko can be used in cataractous patients to guide the selection of the optimal correction for a patient.