1.
MAGMA ; 37(5): 899-907, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38733487

RESUMEN

OBJECTIVE: To prepare and analyze soy-lecithin-agar gels for non-toxic relaxometry phantoms with tissue-like relaxation times at 3T. METHODS: Phantoms mimicking the relaxation times of various tissues (gray and white matter, kidney cortex and medulla, spleen, muscle, liver) were built and tested with a clinical 3T whole-body MR scanner. Simple equations were derived to calculate the appropriate concentrations of soy lecithin and agar in aqueous solutions to achieve the desired relaxation times. Phantoms were tested for correspondence between measurements and calculated T1 and T2 values, reproducibility, spatial homogeneity, and temporal stability. T1 and T2 mapping techniques and a 3D T1-weighted sequence with high spatial resolution were applied. RESULTS: Except for the liver relaxation phantom, all phantoms were successfully and reproducibly produced. Good agreement was found between the targeted and measured relaxation times. The percentage deviations from the targeted relaxation times were less than 3% for T1 and less than 6.5% for T2. In addition, the phantoms were homogeneous and had little to no air bubbles. However, the phantoms were unstable over time: after a storage period of 4 weeks, mold growth and also changes in relaxation times were detected in almost all phantoms. CONCLUSION: Soy-lecithin-agar gels are a non-toxic material for the construction of relaxometry phantoms with tissue-like relaxation times. They are easy to prepare, inexpensive and allow independent adjustment of T1 and T2. However, there is still work to be done to improve the long-term stability of the phantoms.


Asunto(s)
Agar , Lecitinas , Hígado , Imagen por Resonancia Magnética , Fantasmas de Imagen , Imagen por Resonancia Magnética/métodos , Humanos , Agar/química , Reproducibilidad de los Resultados , Hígado/diagnóstico por imagen , Lecitinas/química , Geles/química , Riñón/diagnóstico por imagen , Glycine max , Bazo/diagnóstico por imagen , Sustancia Gris/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen de Cuerpo Entero/métodos , Procesamiento de Imagen Asistido por Computador/métodos
2.
Neuroradiology ; 66(7): 1131-1140, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38492021

RESUMEN

PURPOSE: Vessel-encoded arterial spin labeling (VE-ASL) is able to provide noninvasive information about the contribution of individual arteries to the cerebral perfusion. The aim of this study was to compare VE-ASL to the diagnostic standard digital subtraction angiography (DSA) with respect to its ability to visualize vascular territories. METHODS: In total, 20 VE-ASL and DSA data sets of 17 patients with Moyamoya angiopathy with and without revascularization surgery were retrospectively analyzed. Two neuroradiologists independently assessed the agreement between VE-ASL and DSA using a 4-point Likert scale (no- very high agreement). Additionally, grading of the vascular supply of subterritories (A1-A2, M1-M6) on the VE-ASL images and angiograms was performed. The intermodal agreement was calculated for all subterritories in total and for the subdivision into without and after revascularization (direct or indirect bypass). RESULTS: There was a very high agreement between the VE-ASL and the DSA data sets (median = 1, modus = 1) with a substantial inter-rater agreement (kw = 0.762 (95% CI 0.561-0.963)). The inter-modality agreement between VE-ASL and DSA in vascular subterritories was almost perfect for all subterritories (k = 0.899 (0.865-0.945)), in the subgroup of direct revascularized subterritories (k = 0.827 (0.738-0.915)), in the subgroup of indirect revascularized subterritories (k = 0.843 (0.683-1.003)), and in the subgroup of never revascularized subterritories (k = 0.958 (0.899-1.017)). CONCLUSION: Vessel-encoded ASL seems to be a promising non-invasive method to depict the contributions of individual arteries to the cerebral perfusion before and after revascularization surgery.


Asunto(s)
Angiografía de Substracción Digital , Circulación Cerebrovascular , Enfermedad de Moyamoya , Marcadores de Spin , Humanos , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/cirugía , Angiografía de Substracción Digital/métodos , Femenino , Masculino , Adulto , Persona de Mediana Edad , Estudios Retrospectivos , Angiografía Cerebral/métodos , Arterias Cerebrales/diagnóstico por imagen , Adolescente , Niño , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados
3.
Magn Reson Med ; 92(1): 257-268, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38282291

RESUMEN

PURPOSE: Free water in cortical bone is either contained in nearly cylindrical structures (mainly Haversian canals oriented parallel to the bone axis) or in more spherically shaped pores (lacunae). Those cavities have been reported to crucially influence bone quality and mechanical stability. Susceptibility differences between bone and water can lead to water frequency shifts dependent on the geometric characteristics. The purpose of this study is to calculate and measure the frequency distribution of the water signal in MRI in dependence of the microscopic bone geometry. METHODS: Finite element modeling and analytical approaches were performed to characterize the free water components of bone. The previously introduced UTE-FID technique providing spatially resolved FID-spectra was used to measure the frequency distribution pixel-wise for different orientations of the bone axis. RESULTS: The frequency difference between free water in spherical pores and in canals parallel to B0 amounts up to approximately 100 Hz at 3T. Simulated resonance frequencies showed good agreement with the findings in UTE-FID spectra. The intensity ratio of the two signal components (parallel canals and spherical pores) was found to vary between periosteal and endosteal regions. CONCLUSION: Spatially resolved UTE-FID examinations allow the determination of the frequency distribution of signals from free water in cortical bone. This frequency distribution indicates the composition of the signal contributions from nearly spherical cavities and cylindrical canals which allows for further characterization of bone structure and status.


Asunto(s)
Agua Corporal , Simulación por Computador , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Agua Corporal/diagnóstico por imagen , Algoritmos , Reproducibilidad de los Resultados , Modelos Biológicos , Sensibilidad y Especificidad , Interpretación de Imagen Asistida por Computador/métodos , Agua/química , Huesos/diagnóstico por imagen , Aumento de la Imagen/métodos , Análisis de Elementos Finitos
4.
Acad Radiol ; 31(3): 929-938, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37714720

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate 4D Flow magnetic resonance imaging (MRI) sequences for quantitative flow measurements of the pelvic venous vasculature. MATERIALS AND METHODS: A prospective study of healthy volunteers was performed. After informed consent all subjects underwent 4D flow sequences at a 3 T MRI scanner with different isotropic resolution and different velocity encoding (Venc) settings: (sequence #1) voxel size (VS) 1.63 mm3, Venc 50 cm/s; (sequence #2) VS 1.63 mm3, Venc 100 cm/s and (sequence #3) VS 2.03 mm3, Venc 50 cm/s. Perfusion parameters were calculated for all venous vessel segments starting at the level of the inferior vena cava and extending caudally to the level of the common femoral vein. For reference, arterial flow was calculated using 1.63 mm3 isotropic resolution with a Venc of 100 cm/s. RESULTS: Ten healthy subjects (median age 28 years, interquartile range [IQR]: 26.25-28 years) were enrolled in this study. Median scanning time was 12:12 minutes (IQR 10:22-13:32 minutes) for sequence #1, 11:02 minutes (IQR 9:57-11:19 minutes) for sequence #2 and 6:10 minutes (IQR 5:44-6:47 minutes) for sequence #3. Flow measurements were derived from all sequences. The venous pelvic vasculature showed similar perfusion parameters compared to its arterial counterpart, for example the right common iliac arterial segment showed a perfusion of 8.32 ml/s (IQR: 6.94-10.68 ml/s) versus 7.29 ml/s (IQR: 4.70-8.90 ml/s) in the corresponding venous segment (P = 0.218). The venous flow measurements obtained from the three investigated sequences did not reveal significant differences. CONCLUSION: 4D Flow MRI is suitable for quantitative flow measurement of the venous pelvic vasculature. To reduce the scanning time without compromising quantitative results, the resolution can be decreased while increasing the Venc. This technique may be utilized in the future for the diagnosis and treatment response assessment of iliac vein compression syndromes.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Adulto , Estudios Prospectivos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Arterias , Velocidad del Flujo Sanguíneo/fisiología , Reproducibilidad de los Resultados
5.
Quant Imaging Med Surg ; 13(11): 7467-7483, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37969627

RESUMEN

Background: The field of orthopedics seeks effective, safer methods for evaluating articular cartilage regeneration. Despite various treatment innovations, non-invasive, contrast-free full quantitative assessments of hyaline articular cartilage's regenerative potential using compositional magnetic resonance (MR) sequences remain challenging. In this context, our aim was to investigate the effectiveness of different MR sequences for quantitative assessment of cartilage and to compare them with the current gold standard delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) measurements. Methods: We employed ex vivo imaging in a preclinical minipig model to assess knee cartilage regeneration. Standardized osteochondral defects were drilled in the proximal femur of the specimens (n=14), which were divided into four groups. Porcine collagen scaffolds seeded with autologous adipose-derived stromal cells (ASC), autologous bone marrow stromal cells (BMSC), and unseeded scaffolds (US) were implanted in femoral defects. Furthermore, there was a defect group which received no treatment. After 6 months, the specimens were examined using different compositional MR methods, including the gold standard dGEMRIC as well as T1, T2, T2*, and T1ρ techniques. The statistical evaluation involved comparing the defect region with the uninjured tibia and femur cartilage layers and all measurements were performed on a clinical 3T MR Scanner. Results: In the untreated defect group, we observed significant differences in the defect region, with dGEMRIC values significantly lower (404.86±64.2 ms, P=0.018) and T2 times significantly higher (44.24±2.75 ms, P<0.001). Contrastingly, in all three treatment groups (ASC, BMSC, US), there were no significant differences among the three regions in the dGEMRIC sequence, suggesting successful cartilage regeneration. However, T1, T2*, and T1ρ sequences failed to detect such differences, highlighting their lower sensitivity for cartilage regeneration. Conclusions: As expected, dGEMRIC is well suited for monitoring cartilage regeneration. Interestingly, T2 imaging also proved to be a reliable cartilage imaging technique and thus offers a contrast agent-free alternative to the former gold standard for subsequent in vivo studies investigating the cartilage regeneration potential of different treatment modalities.

6.
Front Cardiovasc Med ; 10: 1145613, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37229222

RESUMEN

Objectives: In this study we examined the correlation between the extent of thoracic lymphatic anomalies in patients after surgical palliation by total cavopulmonary connection (TCPC) and their outcome in terms of clinical and laboratory parameters. Materials and methods: We prospectively examined 33 patients after TCPC with an isotropic heavily T2-weighted MRI sequence on a 3.0 T scanner. Examinations were performed after a solid meal, slice thickness of 0.6 mm, TR of 2400 ms, TE of 692 ms, FoV of 460 mm, covering thoracic and abdominal regions. Findings of the lymphatic system were correlated with clinical and laboratory parameters obtained at the annual routine check-up. Results: Eight patients (group 1) showed type 4 lymphatic abnormalities. Twentyfive patients (group 2) presented less severe anomalies (type 1-3). In the treadmill CPET, group 2 reached step 7.0;6.0/8.0 vs. 6.0;3.5/6.8 in group 1 (p = 0.006*) and a distance of 775;638/854 m vs. 513;315/661 m (p = 0.006*). In the laboratory examinations, group 2 showed significantly lower levels of AST, ALT and stool calprotectin as compared to group 1. There were no significant differences in NT-pro-BNP, total protein, IgG, lymphocytes or platelets, but trends. A history of ascites showed 5/8 patients in group 1 vs. 4/25 patients in group 2 (p = 0.02*), PLE occurred in 4/8 patient in group 1 vs. 1/25 patients in group 2 (p = 0.008*). Conclusion: In the long-term follow-up after TCPC, patients with severe thoracic and cervical lymphatic abnormalities showed restrictions in exercise capacity, higher liver enzymes and an increased rate of symptoms of imminent Fontan-failure such as ascites and PLE.

7.
Diagnostics (Basel) ; 13(10)2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37238230

RESUMEN

(1) Background: We aim to investigate age-related changes in cartilage structure and composition in the metacarpophalangeal (MCP) joints using magnetic resonance (MR) biomarkers. (2) Methods: The cartilage tissue of 90 MCP joints from 30 volunteers without any signs of destruction or inflammation was examined using T1, T2, and T1ρ compositional MR imaging techniques on a 3 Tesla clinical scanner and correlated with age. (3) Results: The T1ρ and T2 relaxation times showed a significant correlation with age (T1ρ: Kendall-τ-b = 0.3, p < 0.001; T2: Kendall-τ-b = 0.2, p = 0.01). No significant correlation was observed for T1 as a function of age (T1: Kendall-τ-b = 0.12, p = 0.13). (4) Conclusions: Our data show an increase in T1ρ and T2 relaxation times with age. We hypothesize that this increase is due to age-related changes in cartilage structure and composition. In future examinations of cartilage using compositional MRI, especially T1ρ and T2 techniques, e.g., in patients with osteoarthritis or rheumatoid arthritis, the age of the patients should be taken into account.

8.
Radiology ; 307(3): e221998, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36809218

RESUMEN

Background Arterial spin labeling (ASL) MRI can be used to assess organ perfusion but has yet to be implemented for perfusion evaluation of the lung. Purpose To evaluate pseudo-continuous ASL (PCASL) MRI for the detection of acute pulmonary embolism (PE) and its potential as an alternative to CT pulmonary angiography (CTPA). Materials and Methods Between November 2020 and November 2021, 97 patients (median age, 61 years; 48 women) with suspected PE were enrolled in this prospective study. PCASL MRI was performed within a 72-hour period following CTPA under free-breathing conditions and included three orthogonal planes. The pulmonary trunk was labeled during systole, and the image was acquired during diastole of the subsequent cardiac cycle. Additionally, multisection, coronal, balanced, steady-state free-precession imaging was carried out. Two radiologists blindly assessed overall image quality, artifacts, and diagnostic confidence (five-point Likert scale, 5 = best). Patients were categorized as positive or negative for PE, and a lobe-wise assessment in PCASL MRI and CTPA was conducted. Sensitivity and specificity were calculated on a patient level with the final clinical diagnosis serving as the reference standard. Interchangeability between MRI and CTPA was also tested with use of an individual equivalence index (IEI). Results PCASL MRI was performed successfully in all patients with high scores for image quality, artifact, and diagnostic confidence (κ ≥ .74). Of the 97 patients, 38 were positive for PE. PCASL MRI depicted PE correctly in 35 of 38 patients with three false-positive and three false-negative findings, resulting in a sensitivity of 35 of 38 patients (92% [95% CI: 79, 98]) and a specificity of 56 of 59 patients (95% [95% CI: 86, 99]). Interchangeability analysis revealed an IEI of 2.6% (95% CI: 1.2, 3.8). Conclusion Free-breathing pseudo-continuous arterial spin labeling MRI depicted abnormal lung perfusion caused by acute pulmonary embolism and may be useful as a contrast material-free alternative to CT pulmonary angiography for selected patients. German Clinical Trials Register no. DRKS00023599 © RSNA, 2023.


Asunto(s)
Imagen por Resonancia Magnética , Embolia Pulmonar , Humanos , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Embolia Pulmonar/diagnóstico , Respiración , Medios de Contraste , Marcadores de Spin
9.
Magn Reson Med ; 89(5): 1754-1776, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36747380

RESUMEN

This review article provides an overview of developments for arterial spin labeling (ASL) perfusion imaging in the body (i.e., outside of the brain). It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group. In this review, we focus on specific challenges and developments tailored for ASL in a variety of body locations. After presenting common challenges, organ-specific reviews of challenges and developments are presented, including kidneys, lungs, heart (myocardium), placenta, eye (retina), liver, pancreas, and muscle, which are regions that have seen the most developments outside of the brain. Summaries and recommendations of acquisition parameters (when appropriate) are provided for each organ. We then explore the possibilities for wider adoption of body ASL based on large standardization efforts, as well as the potential opportunities based on recent advances in high/low-field systems and machine-learning. This review seeks to provide an overview of the current state-of-the-art of ASL for applications in the body, highlighting ongoing challenges and solutions that aim to enable more widespread use of the technique in clinical practice.


Asunto(s)
Encéfalo , Angiografía por Resonancia Magnética , Embarazo , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Marcadores de Spin , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Imagen por Resonancia Magnética/métodos , Perfusión , Imagen de Perfusión , Circulación Cerebrovascular/fisiología
10.
Int J Cardiovasc Imaging ; 39(5): 1023-1030, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36781568

RESUMEN

To evaluate Quiescent Interval Slice Selective (QISS) balanced steady-state free precession (bSSFP) and QISS fast low-angle shot (FLASH) sequences for non-contrast Magnetic Resonance Angiography (MRA) of iliac arteries regarding image quality and diagnostic confidence in order to establish these sequences in daily clinical practice. A prospective study of healthy subjects (n = 10) was performed. All subjects underwent the QISS MRI protocol with bSSFP und FLASH sequences. Vessel contrast-to-background ratio (VCBR) were measured in pre-defined vessel segments. Image quality and diagnostic confidence was assessed using a Likert scale (five-point scale). Inter-reader agreement was determined using Cohen's kappa coefficient (κ). Ten healthy subjects (median age 29 years, IQR: 26.25 to 30 years) were included in this prospective study. Median MR examination time was 2:05 min (IQR 1:58 to 2:16) for QISS bSSFP and 4:11 min (IQR 3:57 to 4:32) for QISS FLASH. Both sequences revealed good VCBR in all examined vessel segments. VCBR (muscle tissue) were marginally higher for FLASH sequences (e.g., 0.82 vs. 0.78 in the right femoral artery, p = 0.035*), while bSSFP sequence showed significantly higher VCBR (fat tissue) in the majority of examined arterials vessels (e.g., 0.78 vs. 0.62 in right femoral artery, p = 0.001*). The image quality and diagnostic confidence of both sequences were rated as good to excellent. Moderate to good inter-reader agreement was found. QISS MRA using bSSFP and FLASH sequences are diagnostic for visualization of iliac arterial vasculature. The QISS bSSFP sequence might offer advantages due to the markedly shorter exam time and superior visualization of smaller vessels. The QISS FLASH sequence seems to be a robust alternative for non-contrast MRA since it is less sensitive to magnetic field inhomogeneities.


Asunto(s)
Arterias , Angiografía por Resonancia Magnética , Humanos , Adulto , Estudios Prospectivos , Valor Predictivo de las Pruebas , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Medios de Contraste
11.
J Nephrol ; 36(4): 1175-1180, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36696037

RESUMEN

Acute allograft injury was observed in a 37-year-old woman within a few weeks after kidney transplantation. Neither renal ultrasound nor computerized tomography (CT) and magnetic resonance (MR) angiography revealed any anomaly. An MR protocol was then performed including arterial spin labeling and intravoxel incoherent motion diffusion weighted imaging. Both arterial spin labeling and the perfusion fraction in the diffusion weighted imaging showed decreased perfusion compared to reference values. The patient subsequently underwent angiography, where an arteriovenous fistula in the upper calix of the transplant kidney was detected and immediate embolization was performed. A second functional MR, performed one week later, demonstrated a 40% increase in organ perfusion. We conclude that functional MR with arterial spin labeling and intravoxel incoherent motion have the potential to provide complementary information of clinical value to conventional imaging for monitoring renal allografts.


Asunto(s)
Fístula Arteriovenosa , Trasplante de Riñón , Femenino , Humanos , Adulto , Trasplante de Riñón/efectos adversos , Imagen por Resonancia Magnética/métodos , Riñón , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/etiología , Fístula Arteriovenosa/terapia , Perfusión , Aloinjertos
12.
Magn Reson Med ; 89(4): 1674-1683, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36458695

RESUMEN

PURPOSE: To test soy lecithin as a substance added to water for the construction of MRI phantoms with tissue-like diffusion coefficients. The performance of soy lecithin was assessed for the useable range of adjustable ADC values, the degree of non-Gaussian diffusion, simultaneous effects on relaxation times, and spectral signal properties. METHODS: Aqueous soy lecithin solutions of different concentrations (0%, 0.5%, 1%, 2%, 3% …, 10%) and soy lecithin-agar gels were prepared and examined on a 3 Tesla clinical scanner at 18.5° ± 0.5°C. Echoplanar sequences (b values: 0-1000/3000 s/mm2 ) were applied for ADC measurements. Quantitative relaxometry and MRS were performed for assessment of T1 , T2 , and detectable spectral components. RESULTS: The presence of soy lecithin significantly restricts the diffusion of water molecules and mimics the nearly Gaussian nature of diffusion observed in tissue (for b values <1000 s/mm2 ). ADC values ranged from 2.02 × 10-3  mm2 /s to 0.48 × 10-3  mm2 /s and cover the entire physiological range reported on biological tissue. Measured T1 /T2 values of pure lecithin solutions varied from 2685/2013 to 668/133 ms with increasing concentration. No characteristic signals of soy lecithin were observed in the MR spectrum. The addition of agar to the soy lecithin solutions allowed T2 values to be well adjusted to typical values found in parenchymal tissue without affecting the soy lecithin-controlled ADC value. CONCLUSION: Soy lecithin is a promising substance for the construction of diffusion phantoms with tissue-like ADC values. It provides several advantages over previously proposed substances, in particular a wide range of adjustable ADC values, the lack of additional 1 H-signals, and the possibility to adjust ADC and T2 values (by adding agar) almost independently of each other.


Asunto(s)
Lecitinas , Imagen por Resonancia Magnética , Agar , Imagen de Difusión por Resonancia Magnética , Fantasmas de Imagen
13.
Diagnostics (Basel) ; 12(11)2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36359572

RESUMEN

Objectives: To systematically compare two modified Look-Locker inversion recovery (MOLLI) T1 mapping sequences and their impact on (1) myocardial T1 values native, (2) post-contrast and (3) extracellular volume (ECV). Methods: 200 patients were prospectively included for 1.5 T CMR for work-up of ischemic or non-ischemic cardiomyopathies. To determine native and post-contrast T1 for ECV calculation, two different T1 mapping MOLLI acquisition schemes, 5(3)3 (designed for native scans with long T1) and 4(1)3(1)2 (designed for post-contrast scans with short T1), were acquired in identical mid-ventricular short-axis slices. Both schemes were acquired in native and post-contrast scans. Results: Datasets from 163 patients were evaluated (age 55 ± 17 years; 38% female). Myocardial T1 native for 5(3)3 was 1017 ± 42 ms vs. 956 ± 40 ms for 4(1)3(1)2, with mean intraindividual difference −61 ms (p < 0.0001). Post-contrast myocardial T1 in patients was similar for both acquisition schemes, with 494 ± 48 ms for 5(3)3 and 490 ± 45 ms for 4(1)3(1)2 and mean intraindividual difference −4 ms. Myocardial ECV for 5(3)3 was 27.6 ± 4% vs. 27 ± 4% for 4(1)3(1)2, with mean difference −0.6 percentage points (p < 0.0001). Conclusions: The T1 MOLLI 5(3)3 acquisition scheme provides a reliable estimation of myocardial T1 for the clinically relevant range of long and short T1 values native and post-contrast. In contrast, the T1 MOLLI 4(1)3(1)2 acquisition scheme may only be used for post-contrast scans according to its designed purpose.

15.
Rofo ; 194(9): 983-992, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35272360

RESUMEN

BACKGROUND: Until today, assessment of renal function has remained a challenge for modern medicine. In many cases, kidney diseases accompanied by a decrease in renal function remain undetected and unsolved, since neither laboratory tests nor imaging diagnostics provide adequate information on kidney status. In recent years, developments in the field of functional magnetic resonance imaging with application to abdominal organs have opened new possibilities combining anatomic imaging with multiparametric functional information. The multiparametric approach enables the measurement of perfusion, diffusion, oxygenation, and tissue characterization in one examination, thus providing more comprehensive insight into pathophysiological processes of diseases as well as effects of therapeutic interventions. However, application of multiparametric fMRI in the kidneys is still restricted mainly to research areas and transfer to the clinical routine is still outstanding. One of the major challenges is the lack of a standardized protocol for acquisition and postprocessing including efficient strategies for data analysis. This article provides an overview of the most common fMRI techniques with application to the kidney together with new approaches regarding data analysis with deep learning. METHODS: This article implies a selective literature review using the literature database PubMed in May 2021 supplemented by our own experiences in this field. RESULTS AND CONCLUSION: Functional multiparametric MRI is a promising technique for assessing renal function in a more comprehensive approach by combining multiple parameters such as perfusion, diffusion, and BOLD imaging. New approaches with the application of deep learning techniques could substantially contribute to overcoming the challenge of handling the quantity of data and developing more efficient data postprocessing and analysis protocols. Thus, it can be hoped that multiparametric fMRI protocols can be sufficiently optimized to be used for routine renal examination and to assist clinicians in the diagnostics, monitoring, and treatment of kidney diseases in the future. KEY POINTS: · Multiparametric fMRI is a technique performed without the use of radiation, contrast media, and invasive methods.. · Multiparametric fMRI provides more comprehensive insight into pathophysiological processes of kidney diseases by combining functional and structural parameters.. · For broader acceptance of fMRI biomarkers, there is a need for standardization of acquisition, postprocessing, and analysis protocols as well as more prospective studies.. · Deep learning techniques could significantly contribute to an optimization of data acquisition and the postprocessing and interpretation of larger quantities of data.. CITATION FORMAT: · Zhang C, Schwartz M, Küstner T et al. Multiparametric Functional MRI of the Kidney: Current State and Future Trends with Deep Learning Approaches. Fortschr Röntgenstr 2022; 194: 983 - 992.


Asunto(s)
Aprendizaje Profundo , Enfermedades Renales , Imágenes de Resonancia Magnética Multiparamétrica , Humanos , Riñón/fisiología , Imagen por Resonancia Magnética , Estudios Prospectivos
16.
World J Urol ; 40(6): 1455-1461, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35357510

RESUMEN

PURPOSE: Purpose of this study is to evaluate the diagnostic accuracy of quantitative T2/ADC values in differentiating between PCa and lesions showing non-specific inflammatory infiltrates and atrophy, features of chronic prostatitis, as the most common histologically proven differential diagnosis. METHODS: In this retrospective, single-center cohort study, we analyzed 55 patients suspected of PCa, who underwent mpMRI (3T) including quantitative T2 maps before robot-assisted mpMRI-TRUS fusion prostate biopsy. All prostate lesions were scored according to PI-RADS v2.1. Regions of interest (ROIs) were annotated in focal lesions and normal prostate tissue. Quantitative mpMRI values from T2 mapping and ADC were compared using two-tailed t tests. Receiver operating characteristic curves (ROCs) and cutoff were calculated to differentiate between PCa and chronic prostatitis. RESULTS: Focal lesions showed significantly lower ADC and T2 mapping values than normal prostate tissue (p < 0.001). PCa showed significantly lower ADC and T2 values than chronic prostatitis (p < 0.001). ROC analysis revealed areas under the receiver operating characteristic curves (AUCs) of 0.85 (95% CI 0.74-0.97) for quantitative ADC values and 0.84 (95% CI 0.73-0.96) for T2 mapping. A significant correlation between ADC and T2 values was observed (r = 0.70; p < 0.001). CONCLUSION: T2 mapping showed high diagnostic accuracy for differentiating between PCa and chronic prostatitis, comparable to the performance of ADC values.


Asunto(s)
Neoplasias de la Próstata , Prostatitis , Estudios de Cohortes , Imagen de Difusión por Resonancia Magnética , Humanos , Biopsia Guiada por Imagen , Imagen por Resonancia Magnética , Masculino , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Prostatitis/diagnóstico por imagen , Prostatitis/patología , Estudios Retrospectivos
17.
MAGMA ; 35(3): 401-410, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34698962

RESUMEN

OBJECTIVE: To provide a basis for the selection of suitable emulsifiers in oil-in-water emulsions used as tissue analogs for MRI experiments. Three different emulsifiers were investigated with regard to their ability to stabilize tissue-like oil-in-water emulsions. Furthermore, MR signal properties of the emulsifiers themselves and influences on relaxation times and ADC values of the aqueous phase were investigated. MATERIALS AND METHODS: Polysorbate 60, sodium dodecyl sulfate (SDS) and soy lecithin were used as emulsifiers. MR characteristics of emulsifiers were assessed in aqueous solutions and their function as a stabilizer was examined in oil-in-water emulsions of varying fat content (10, 20, 30, 40, 50%). Stability and homogeneity of the oil-in-water emulsions were evaluated with a delay of 3 h and 9 h after preparation using T1 mapping and visual control. Signal properties of the emulsifiers were investigated by 1H-MRS in aqueous emulsifier solutions. Relaxometry and diffusion weighted MRI (DWI) were performed to investigate the effect of various emulsifier concentrations on relaxation times (T1 and T2) and ADC values of aqueous solutions. RESULTS: Emulsions stabilized by polysorbate 60 or soy lecithin were stable and homogeneous across all tested fat fractions. In contrast, emulsions with SDS showed a significantly lower stability and homogeneity. Recorded T1 maps revealed marked creaming of oil droplets in almost all of the emulsions with SDS. The spectral analysis showed several additional signals for polysorbate and SDS. However, lecithin remained invisible in 1H-MRS. Relaxometry and DWI revealed different influences of the emulsifiers on water: Polysorbate and SDS showed only minor effects on relaxation times and ADC values of aqueous solutions, whereas lecithin showed a strong decrease in both relaxation times (r1,lecithin = 0.11 wt.%-1 s-1, r2,lecithin = 0.57 wt.%-1 s-1) and ADC value (Δ(ADC)lecithin = - 0.18 × 10-3 mm2/s⋅wt.%) with increasing concentration. CONCLUSION: Lecithin is suggested as the preferred emulsifier of oil-in-water emulsions in MRI as it shows a high stabilizing ability and remains invisible in MRI experiments. In addition, lecithin is suitable as an alternative means of adjusting relaxation times and ADC values of water.


Asunto(s)
Lecitinas , Polisorbatos , Emulsionantes , Emulsiones , Imagen por Resonancia Magnética , Tamaño de la Partícula , Agua
18.
Magn Reson Med ; 87(5): 2099-2110, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34866240

RESUMEN

PURPOSE: Biologically interesting signals can exhibit fast transverse relaxation and frequency shifts compared to free water. For spectral assignment, a ultra-short echo time (UTE) imaging sequence was modified to provide pixel-wise free-induction decay (FID) acquisition. METHODS: The UTE-FID approach presented relies on a multi-echo 3D spiral UTE sequence with six echoes per radiofrequency (RF) excitation (TEmin 0.05 ms, echo spacing 3 ms). A complex pixel-wise raw data set for FID spectroscopy is obtained by several multi-echo UTE measurements with systematic shifting of the readout by 0.25 or 0.5 ms, until the time domain is filled for 18 or 45 ms. B0 drifts are compensated by mapping and according phase correction. Autoregressive extrapolation of the signal is performed before Gaussian filtering. This method was applied to a phantom containing collagen-water solutions of different concentrations. To calculate the collagen content, a 19-peak collagen model was extracted from a non-selective FID spectrum (50% collagen solution). Proton-density-collagen-fraction (PDCF) was calculated for 10 collagen solutions (2%-50%). Furthermore, an in vivo UTE-FID spectrum of adipose tissue was recorded. RESULTS: UTE-FID signal patterns agreed well with the non-spatially selective pulse-acquire FID spectrum from a sphere filled with 50% collagen. Differentiation of collagen solution from distilled water in the PDCF map was possible from 4% collagen concentration for a UTE-FID sequence with 128 × 128 × 64 matrix (voxel size 1 × 1 × 2.85 mm3 ). The mean values of the PDCF correlate linearly with collagen concentration. CONCLUSION: The presented UTE-FID approach allows pixel-wise raw data acquisition similar to non-spatially selective pulse-acquire spectroscopy. Spatially resolved applications for assessment of spectra of rapidly decaying signals seem feasible.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Protones , Análisis Espectral
19.
Front Med (Lausanne) ; 8: 697055, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34447762

RESUMEN

Background: Kidney perfusion and oxygenation are two important determinants of kidney graft function. In kidney transplantation, repeated graft hypoperfusion may occur during hip flexion, for example in the sitting position, due to the progressive development of fibrotic tissue around iliac arteries. The aim of this study was to assess the changes in oxygenation and perfusion of kidney grafts during hip flexion and extension using a new functional magnetic resonance imaging (fMRI) protocol. Methods: Nineteen kidney graft recipients prospectively underwent MRI on a 3T scanner including diffusion-weighted, blood oxygenation level dependent (BOLD), and arterial spin labeling sequences in hip positions 0° and >90° before and after intravenous administration of 20 mg furosemide. Results: Unexpectedly, graft perfusion values were significantly higher in flexed compared to neutral hip position. Main diffusion-derived parameters were not affected by hip position. BOLD-derived cortico-medullary R2* ratio was significantly modified during hip flexion suggesting an intrarenal redistribution of the oxygenation in favor of the medulla and to the detriment of the cortex. Furthermore, the increase in medullary oxygenation induced by furosemide was significantly blunted during hip flexion (p < 0.001). Conclusion: Hip flexion has an acute impact on perfusion and tissue oxygenation in kidney grafts. Whether these position-dependent changes affect the long-term function and outcome of kidney transplants needs further investigation.

20.
J Appl Clin Med Phys ; 22(10): 261-269, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34453864

RESUMEN

PURPOSE: To evaluate the transient artifact augmentation of microtubes in magnetic resonance imaging by fluid injection. METHODS: Twenty-one fluorinated ethylene propylene catheters (inner diameter 760 µm) were filled with three different contrast media at various concentrations (Ferucarbotran, Resovist®, Bayer Schering Pharma; Manganese dichloride, MnCl2, Sigma-Aldrich; Gadobutrol, Gadovist®, Bayer Schering Pharma). Artifact appearance was determined in an ex vivo phantom at 1.5 T using three different sequences: T1-weighted three-dimensional volume interpolated breath-hold examination, T2-weighted turbo spin echo, and T1-weighted fast low angle shot. Catheter angulation to the main magnetic field (B0) was varied. Influence of parameters on artifact diameters was assessed with a multiple linear regression similar to an analysis of variance. RESULTS: Artifact diameter was significantly influenced by the contrast agent (p < 0.001), concentration of the contrast agent (p < 0.001), angulation of the phantom to B0 with the largest artifact at 90° (p < 0.001), and encoding direction with a larger diameter in phase encoding direction (PED, p < 0.001). Mean artifact diameters at 90° angulation to B0 in PED were 18.5 ± 5.4 mm in 0.5 mmol/ml Ferucarbotran, 8.7 ± 2.5 mm in 1 mmol/ml Gadobutrol, and 11.6 ± 4.6 mm in 5 mmol/ml MnCl2 . CONCLUSIONS: Fluid-based contrast agents might be applied to interventional devices and thus temporarily augment the artifact ensuring both visibility and safe navigation.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Medios de Contraste , Humanos , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen
SELECCIÓN DE REFERENCIAS