Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 141
Filtrar
1.
J Endocrinol Invest ; 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38696125

RESUMEN

BACKGROUND: Papillary craniopharyngiomas harbor the BRAF V600E mutation, which paves the way for using BRAF inhibitor molecules to treat tumors refractory to standard therapies. Single case reports confirmed the efficacy of targeted therapy. However, most reports were limited by the short follow-up. We describe the long-term course of a patient treated with dual-agent BRAF and MEK inhibitors and review the available literature. CASE REPORT: A 75-year-old male patient had recurrence of a papillary craniopharyngioma after transsphenoidal surgery and Gamma Knife radiosurgery. Review of the pathologic specimen confirmed the presence of the BRAF V600E mutation. Because of the few therapeutic options, we decided to initiate BRAF/MEK inhibitor combined therapy for six months. Rapid reduction of the tumor occurred, but three months after quitting combined medical therapy the tumor recurred. BRAF/MEK inhibitor therapy was resumed and the tumor again showed a marked reduction. The second course was maintained for 20 months and the tumor showed another recurrence within three months, which, again, responded to a third course of targeted therapy. CONCLUSIONS: Our study confirms the excellent response of papillary craniopharyngioma to combined BRAF and MEK inhibitors. However, rapid tumor recurrence is the rule when medical therapy is stopped. Resistance to a second and third course of targeted therapy did not occur, suggesting that tumor mutations affecting the response to drugs seems an uncommon event in papillary craniopharyngioma. The exact role of targeted therapy in the treatment algorithm of papillary craniopharyngiomas has still to be refined.

2.
Radiother Oncol ; 194: 110160, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38369025

RESUMEN

PURPOSE: The early regression index (ERI) predicts treatment response in rectal cancer patients. Aim of current study was to prospectively assess tumor response to neoadjuvant chemo-radiotherapy (nCRT) of locally advanced esophageal cancer using ERI, based on MRI. MATERIAL AND METHODS: From January 2020 to May 2023, 30 patients with esophageal cancer were enrolled in a prospective study (ESCAPE). PET-MRI was performed: i) before nCRT (tpre); ii) at mid-radiotherapy, tmid; iii) after nCRT, 2-6 weeks before surgery (tpost); nCRT delivered 41.4 Gy/23fr with concurrent carboplatin and paclitaxel. For patients that skipped surgery, complete clinical response (cCR) was assessed if patients showed no local relapse after 18 months; patients with pathological complete response (pCR) or with cCR were considered as complete responders (pCR + cCR). GTV volumes were delineated by two observers (Vpre, Vmid, Vpost) on T2w MRI: ERI and other volume regression parameters at tmid and tpost were tested as predictors of pCR + cCR. RESULTS: Complete data of 25 patients were available at the time of the analysis: 3/25 with complete response at imaging refused surgery and 2/3 were cCR; in total, 10/25 patients showed pCR + cCR (pCR = 8/22). Both ERImid and ERIpost classified pCR + cCR patients, with ERImid showing better performance (AUC:0.78, p = 0.014): A two-variable logistic model combining ERImid and Vpre improved performances (AUC:0.93, p < 0.0001). Inter-observer variability in contouring GTV did not affect the results. CONCLUSIONS: Despite the limited numbers, interim analysis of ESCAPE study suggests ERI as a potential predictor of complete response after nCRT for esophageal cancer. Further validation on larger populations is warranted.


Asunto(s)
Neoplasias Esofágicas , Imagen por Resonancia Magnética , Terapia Neoadyuvante , Humanos , Neoplasias Esofágicas/terapia , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/patología , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Anciano , Quimioradioterapia , Paclitaxel/administración & dosificación , Carboplatino/administración & dosificación , Resultado del Tratamiento , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Adulto
3.
J Nutr Health Aging ; 25(9): 1076-1083, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34725664

RESUMEN

The World elderly population is expected to double before 2050. Unhealthy habits and unhealthy lifestyles are commonly associated with age-related diseases or their worsening. Modification in daily lifestyle and diet may help preventing age-related diseases onset and efficiently affecting their evolution, thus promoting the Healthy Aging process, concept recently coined to describe the disease-free aging process. This review highlights the role of nutrition science in promoting healthy aging. Since the Mediterranean Model demonstrated to be a useful style in supporting healthy aging, promotion of this correct lifestyle by health policies seems to be the best approach to achieve this target.


Asunto(s)
Dieta Mediterránea , Envejecimiento Saludable , Anciano , Dieta , Estado de Salud , Humanos , Estilo de Vida
4.
J Biol Regul Homeost Agents ; 35(1): 171-183, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33491346

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic is a worldwide medical challenge due to the scarcity of proper information and remedial resources. The ability to efficiently avoid a further SARS-CoV-2 pandemic will, therefore, depend on understanding several factors which include host immunity, virus behavior, prevention measures, and new therapies. This is a multi-phase observatory study conducted in the SG Moscati Hospital of Taranto in Italy that was converted into COVID-19 Special Care Unit for SARS-Co-V2 risk management. Patients were admitted to the 118 Emergency Pre-Hospital and Emergency Department based on two diagnostic criteria, the nasopharyngeal swab assessed by reverse-transcriptase-polymerase-chain-reaction (RT-PCR) and CT-scan image characterized by ground glass opacity. Patients were divided into four groups, positive-positive (ER-PP), negative-positive (ER-NP), negative-negative (ER-NN) and a group admitted to the ICU (ER-IC). A further control group was added when the T and B lymphocyte subsets were analyzed. Data included gender, age, vital signs, arterial blood gas analysis (ABG), extensive laboratory results with microbiology and bronchoalveolar lavage fluid (BALF) which were analyzed and compared. Fundamental differences were reported among the groups. Males were significantly higher in PP, ICU, and NP groups, from 2 to 4-fold higher than females, while in the NN group, the number of females was mildly higher than males; the PP patients showed a marked alkalotic, hypoxic, hypocapnia ABG profile with hyperventilation at the time of admission; finally, the laboratory and microbiology results showed lymphopenia, fibrinogen, ESR, CRP, and eGFR were markedly anomalous. The total number of CD4+ and CD8+ T cells was dramatically reduced in COVID-19 patients with levels lower than the normal range delimited by 400/µL and 800/µL, respectively, and were negatively correlated with blood inflammatory responses.


Asunto(s)
COVID-19/diagnóstico , COVID-19/fisiopatología , Femenino , Hospitalización , Hospitales , Humanos , Unidades de Cuidados Intensivos , Italia , Masculino , Pandemias
5.
Radiography (Lond) ; 27(2): 743-747, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32998840

RESUMEN

Multiple polymerase chain reaction (RT-PCR) is considered the gold standard diagnostic investigation for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that causes coronavirus disease 2019 (COVID-19). However, false negative multiple polymerase chain reaction (RT-PCR) results can be diagnostically challenging. We report three patients with history of fever and different clinical signs. During the height of the pandemic in Italy (March to May 2020), these patients underwent chest computed tomography (CT) scans that showed lung alterations typical of COVID-19 with multiple negative RT-PCR tests and positive serology for SARS-CoV-2. Two of the three patients showed residual pneumonia on CT after the onset of the first clinical signs. One patient presented with diarrhoea without respiratory symptoms. These cases suggest that in the COVID-19 pandemic period, to provide an earlier specific treatment in patients with positive serology, a chest CT scan can be useful in those presenting with a fever or a history of fever associated with persistent mild respiratory symptoms or with abdominal complaints despite repeated negative RT-PCR results.


Asunto(s)
COVID-19/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , COVID-19/diagnóstico , Prueba de Ácido Nucleico para COVID-19 , Prueba Serológica para COVID-19 , Diarrea/virología , Disnea/virología , Reacciones Falso Negativas , Femenino , Fiebre/virología , Humanos , Masculino , Persona de Mediana Edad , SARS-CoV-2
6.
Acta Biomater ; 115: 299-316, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32853810

RESUMEN

The active and passive mechanical behavior of a cosmetic tightening product for skin anti-aging is investigated based on a wide range of in vivo and in vitro measurements. The experimental data are used to inform a numerical model of the attained cosmetic effect, which is then implemented in a commercial finite-element framework and used to analyze the mechanisms that regulate the biomechanical interaction between the native tissue and the tightening film. Such a film reduces wrinkles and enhances skin consistency by increasing its stiffness by 48-107% and reducing inelastic, non-recoverable deformations (-47%). The substrate deformability influences both the extent of tightening and the reduction of wrinkle amplitude. The present findings allow, for the first time, to rationalize the mechanisms of action of cosmetic products with a tightening action and provide quantitative evidence for further optimization of this fascinating class of biomaterials.


Asunto(s)
Cosméticos , Envejecimiento de la Piel , Fenómenos Biomecánicos , Biofisica , Cosméticos/farmacología , Humanos , Piel
7.
Surg Oncol ; 33: 170-176, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32561084

RESUMEN

BACKGROUND: Extra-regional lymph node metastases strongly determine treatment options in patients with esophageal cancer. Staging modalities such as (FDG-PET) CT scanning frequently show activity in retroperitoneal and lung hilar lymph nodes. This study evaluated the incidence of histologically confirmed metastases, treatment approach and recurrence patterns in patients with (FDG-PET) CT positivity in these regions. METHODS: All patients with (FDG-PET-) CT positive hilar and/or retroperitoneal lymph nodes at primary staging or restaging discussed at a multidisciplinary tumor board meeting for staging of esophageal cancer between January 2012-December 2017 were included. Biopsies and follow-up were evaluated to determine the presence of metastases and progression rates. RESULTS: From 2012 to 2017, 65 of 857 patients (7.6%) were selected with positive retroperitoneal and/or hilar lymph nodes. A total of 47/65 (72.3%) patients had positive retroperitoneal lymph nodes, which contained metastases in 19 (29.2%). When no biopsy was performed and curative treatment was given (n = 14), 9 patients had progression or locoregional and distant recurrence. Positive hilar lymph nodes were identified in 21 (32.3%) patients; 4 were biopsied and none contained metastases. In these patients no recurrence of disease was seen during follow-up. CONCLUSIONS: The majority of biopsied (PET)CT-positive retroperitoneal lymph nodes at staging contained metastases, while biopsied (PET)CT-positive hilar nodes did not. Histological evaluation of (PET)CT -positive retroperitoneal lymph nodes at staging imaging is recommended, while based on this small series, (PET)CT-positive hilar lymph nodes most likely represent reactive lymphadenopathy.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Neoplasias Esofágicas/diagnóstico por imagen , Carcinoma de Células Escamosas de Esófago/diagnóstico por imagen , Ganglios Linfáticos/diagnóstico por imagen , Adenocarcinoma/secundario , Adenocarcinoma/terapia , Anciano , Quimioradioterapia , Neoplasias Esofágicas/patología , Neoplasias Esofágicas/secundario , Neoplasias Esofágicas/terapia , Carcinoma de Células Escamosas de Esófago/secundario , Carcinoma de Células Escamosas de Esófago/terapia , Esofagectomía , Femenino , Humanos , Pulmón , Ganglios Linfáticos/patología , Metástasis Linfática , Masculino , Persona de Mediana Edad , Terapia Neoadyuvante , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Espacio Retroperitoneal
8.
Eur Rev Med Pharmacol Sci ; 24(5): 2692-2703, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32196620

RESUMEN

OBJECTIVE: In this premarket clinical study, we evaluated the efficacy and safety of a novel Hydrogel (HYADD4-G) for reducing low back pain (LBP) in patients with degenerative disc disease (DDD). PATIENTS AND METHODS: Twenty-three patients with chronic LBP were enrolled. All patients presented with up to three lumbar black discs (Pfirrmann grade III or IV), LBP of at least 40 mm on the Visual Analogue Scale (VAS), and a Roland-Morris Disability Questionnaire (RMDQ) score of at least 9. Patients received a single 1.5 ml intradiscal injection of HYADD4-G (8 mg/ml), guided by X-ray. Our primary endpoint was the change in VAS score from baseline (day 0) to 4, 12, and 24 weeks. Our secondary endpoints were black disc hydration by Magnetic Resonance Imaging (MRI); the patient's therapeutic response according to the RMDQ; the quality of life, as determined by the EuroQol-5 Dimension (EQ-5D) Index; and a global assessment of patient health status, safety, and local tolerability. RESULTS: Compared with baseline values, VAS score showed a significant reduction at each time point, and across the overall 24-week follow-up period (p < 0.0001). MRI scanning observed a significant reduction in Pfirrmann grade from baseline, by at least one grade, at both week 4 (p = 0.0039) and week 24 (p = 0.0010). Furthermore, compared with baseline values, there was a significant reduction in RMDQ score at each timepoint, and across the entire study period (p < 0.0001). The EQ-5D index increased significantly from baseline to week 24 (p = 0.0001). Finally, mean VAS scores for Patient Global Assessment (PTGA), and Clinical Observer Global Assessment (COGA), decreased significantly at each time point (p < 0.0001), except for week 4. CONCLUSIONS: HYADD4-G proved to be an efficient reliever of low back pain due to DDD.


Asunto(s)
Hidrogeles/uso terapéutico , Degeneración del Disco Intervertebral/tratamiento farmacológico , Dolor de la Región Lumbar/tratamiento farmacológico , Adulto , Femenino , Humanos , Hidrogeles/administración & dosificación , Inyecciones Espinales , Degeneración del Disco Intervertebral/diagnóstico , Dolor de la Región Lumbar/diagnóstico , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Manejo del Dolor , Dimensión del Dolor
9.
Acta Biomater ; 81: 169-183, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30273744

RESUMEN

The development and application of nanofibres requires a thorough understanding of the mechanical properties on a single fibre level including respective modelling tools for precise fibre analysis. This work presents a mechanical and morphological study of poly-l-lactide nanofibres developed by needleless electrospinning. Atomic force microscopy (AFM) and micromechanical testing (MMT) were used to characterise the mechanical response of the fibres within a diameter range of 200-1400 nm. Young's moduli E determined by means of both methods are in sound agreement and show a strong increase for thinner fibres below a critical diameter of 800 nm. Similar increasing trends for yield stress and hardening modulus were measured by MMT. Finite element analyses show that the common practice of modelling three-point bending tests with either double supported or double clamped beams is prone to significant bias in the determined elastic properties, and that the latter is a good approximation only for small diameters. Therefore, an analytical formula based on intermediate boundary conditions is proposed that is valid for the whole tested range of fibre diameters, providing a consistently low error in axial Young's modulus below 10%. The analysis of fibre morphology by differential scanning calorimetry and 2D wide-angle X-ray scattering revealed increasing polymer chains alignment in the amorphous phase and higher crystallinity of fibres for decreasing diameter. The combination of these observations with the mechanical characterisation suggests a linear relationship between Young's modulus and both crystallinity and molecular orientation in the amorphous phase. STATEMENT OF SIGNIFICANCE: Fibrous membranes have rapidly growing use in various applications, each of which comes with specific property requirements. However, the development and production of nanofibre membranes with dedicated mechanical properties is challenging, in particular with techniques suitable for industrial scales such as needleless electrospinning. It is therefore a key step to understand the mechanical and structural characteristics of single nanofibres developed in this process, and to this end, the present work presents changes of internal fibre structure and mechanical properties with diameter, based on dedicated models. Special attention was given to the commonly used models for analyzing Young's modulus of single nanofibers in three-point bending tests, which are shown to be prone to large errors, and an improved robust approach is proposed.


Asunto(s)
Materiales Biocompatibles/química , Nanofibras/química , Poliésteres/química , Módulo de Elasticidad
10.
J Cardiovasc Transl Res ; 11(6): 470-482, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30105605

RESUMEN

Transcatheter aortic valve replacement (TAVR) is being extended to younger patients. However, TAVR-compatible bioprostheses are based on xenogeneic materials with limited durability. Off-the-shelf tissue-engineered heart valves (TEHVs) with remodeling capacity may overcome the shortcomings of current TAVR devices. Here, we develop for the first time a TEHV for TAVR, based on human cell-derived extracellular matrix and integrated into a state-of-the-art stent for TAVR. The TEHVs, characterized by a dense acellular collagenous matrix, demonstrated in vitro functionality under aortic pressure conditions (n = 4). Next, transapical TAVR feasibility and in vivo TEHV functionality were assessed in acute studies (n = 5) in sheep. The valves successfully coped with the aortic environment, showing normal leaflet motion, free coronary flow, and absence of stenosis or paravalvular leak. At explantation, TEHVs presented full structural integrity and initial cell infiltration. Its long-term performance proven, such TEHV could fulfill the need for next-generation lifelong TAVR prostheses.


Asunto(s)
Válvula Aórtica/trasplante , Bioprótesis , Prótesis Valvulares Cardíacas , Ingeniería de Tejidos/métodos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Animales , Válvula Aórtica/citología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/metabolismo , Células Cultivadas , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Matriz Extracelular/metabolismo , Estudios de Factibilidad , Hemodinámica , Humanos , Modelos Animales , Diseño de Prótesis , Oveja Doméstica , Factores de Tiempo , Andamios del Tejido , Tomografía Computarizada por Rayos X
11.
Comput Methods Biomech Biomed Engin ; 21(5): 399-407, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29996696

RESUMEN

We aim to maximize the pumping volume of a pulsatile ventricular assist device, where the diaphragm is covered with an endothelial cell layer. These cells are estimated to survive a cyclic strain up to fifteen percent. To increase the pumping volume under this strain constraint we use an approach based on corrugation of the diaphragm in its reference configuration. The paper explains the parametrization scheme for finding corrugation shapes, addresses modeling and evaluation schemes and reports on the results of a parameter study. The results show that corrugated diaphragm shapes are effective for increasing pumping volumes under a strain constraint.


Asunto(s)
Diafragma/anatomía & histología , Corazón Auxiliar , Ensayo de Materiales , Flujo Pulsátil , Humanos , Modelos Teóricos , Presión
12.
J Mech Behav Biomed Mater ; 77: 711-717, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28867371

RESUMEN

A systematic investigation of the factors affecting the suture retention test is performed. The specimen width w and the distance a of the suture bite from the specimen free edge emerge as the most influential geometrical parameters. A conservative approach for the quantification of suture retention strength is identified, based on the use of a camera to monitor the incipient failure and detect the instant of earliest crack propagation. The corresponding critical force, called break starting strength, is extremely robust against test parameter variations and its dependence on the specimen geometry becomes negligible when a≥ 2mm and w≥ 10mm. Comparison of suture retention and mode I crack opening tests reveals a linear correlation between break starting strength and tearing energy. This suggests that the defect created by the needle and the load applied by the suture thread lead to a fracture mechanics problem, which dominates the initiation of failure.


Asunto(s)
Amnios/patología , Materiales Biocompatibles/química , Pericardio/patología , Suturas , Animales , Fenómenos Biomecánicos , Bovinos , Análisis de Elementos Finitos , Humanos , Ensayo de Materiales , Fenómenos Mecánicos , Agujas , Estrés Mecánico , Técnicas de Sutura , Porcinos , Resistencia a la Tracción
13.
J Biomech Eng ; 139(12)2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28813570

RESUMEN

Predictive simulations of the mastication system would significantly improve our understanding of temporomandibular joint (TMJ) disorders and the planning of cranio-maxillofacial surgery procedures. Respective computational models must be validated by experimental data from in vivo characterization of the mastication system's mechanical response. The present pilot-study demonstrates the feasibility of a combined experimental and numerical procedure to validate a computer model of the masseter muscle. An experimental setup is proposed that provides a simultaneous bite force measurement and ultrasound-based visualization of muscle deformation. The direct comparison of the experimentally observed and numerically predicted muscle response demonstrates the predictive capabilities of such anatomically accurate biting models. Differences between molar and incisor biting are investigated; muscle deformation is recorded for three different bite forces in order to capture the effect of increasing muscle fiber recruitment. The three-dimensional (3D) muscle deformation at each bite position and force-level is approximatively reconstructed from ultrasound measurements in five distinct cross-sectional areas (four horizontal and one vertical cross section). The experimental work is accompanied by numerical simulations to validate the predictive capabilities of a constitutive muscle model previously formulated. An anatomy-based, fully 3D model of the masseter muscle is created from magnetic resonance images (MRI) of the same subject. The direct comparison of experimental and numerical results revealed good agreement for maximum bite forces and masseter deformations in both biting positions. The present work therefore presents a feasible in vivo measurement system to validate numerically predicted masseter muscle contractions during mastication.


Asunto(s)
Análisis de Elementos Finitos , Músculo Masetero/fisiología , Masticación , Fenómenos Mecánicos , Fenómenos Biomecánicos , Humanos , Incisivo/fisiología , Diente Molar/fisiología
14.
Transplant Proc ; 49(4): 677-681, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28457370

RESUMEN

The aims of this study were to define in a cohort of 310 liver transplant recipients, the incidence of post-liver transplantation (LT) non-carbapenem-resistant Klebsiella pneumoniae (CRKP) and CRKP infections, pre- and post-LT CRKP colonization, CRKP-associated mortality, and risk factors for non-CRKP and CRKP infections. Every patient was screened for CRKP immediately before and after LT. The 6-month survival rate was 95%. Fifty-two patients became infected (16.5%): 8 by CRKP (2.5%) and 44 (14%) by a non-CRKP micro-organism. Median onset of CRKP infections occurred at postoperative (POD) 12 (range, 4-70). CRKP colonization occurred in 20 patients (6%): 10 before LT (3 infected and died) and 10 after (5 infected, 3 died). CRKP- versus non-CRKP-infected patients had higher rates of intensive care unit (ICU) and hospital mortality (50% vs 20% and 62.5% vs 36%; P ≤ .001), septic shock (87% vs 34%; P = .0057; confidence interval [CI], 9.8-71.5), prolonged mechanical ventilation (100% vs 64%; P = .043, CI, 3.5-51.9), and renal replacement therapy (87% vs 41%; P = .0177; CI, 2.8-65). The small number of CRKP-infected patients did not allow the definition of specific risk factors for CRKP infection. At univariate analysis, pre- and post-LT colonization (odds ratio [OR], 10.76; CI, 2.6-44; OR, 14.99; CI, 3.83-58.66, respectively), relaparotomy (OR, 9.09; CI, 4.01-20.6), retransplantation (OR, 7.45; CI, 3.45-16), bile leakage (OR, 61.28; CI, 9.23-80), and early allograft dysfunction (EAD; OR, 5.7; CI, 3-10.7) were significantly associated with infections, making CRKP colonization (any time) and post-LT surgical and medical complications critical factors for post-LT CRKP infections.


Asunto(s)
Infecciones por Klebsiella/epidemiología , Trasplante de Hígado/efectos adversos , Adulto , Antibacterianos/uso terapéutico , Carbapenémicos/farmacología , Farmacorresistencia Bacteriana , Femenino , Humanos , Incidencia , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Estudios Retrospectivos , Factores de Riesgo
15.
Med Oncol ; 34(5): 96, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28417355

RESUMEN

The LUMIRA trial evaluated the effectiveness of radiofrequency (RFA) and microwave ablation (MWA) in lung tumours ablation and defining more precisely their fields of application. It is a controlled prospective multi-centre random trial with 1:1 randomization. Fifty-two patients in stage IV disease (15 females and 37 males, mean age 69 y.o., range 40-87) were included. We randomized the patients in two different subgroups: MWA group and RFA group. For each group, we evaluated the technical and clinical success, the overall survival and complication rate. Inter-group difference was compared using Chi-square test or Fisher's exact test for categorical variables and one-way ANOVA test for continuous variables. For RFA group, there was a significant reduction in tumour size only between 6 and 12 months (p value = 0.0014). For MWA group, there was a significant reduction in tumour size between 6 and 12 months (p value = 0.0003) and between pre-therapy and 12 months (p value = 0.0215). There were not significant differences between the two groups in terms of survival time (p value = 0.883), while the pain level in MWA group was significantly less than in RFA group (1.79 < 3.25, p value = 0.0043). In conclusion, our trial confirms RFA and MWA are both excellent choices in terms of efficacy and safety in lung tumour treatments. However, when compared to RFA therapy, MWA produced a less intraprocedural pain and a significant reduction in tumour mass.


Asunto(s)
Ablación por Catéter/métodos , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos
16.
Ultrasound Int Open ; 2(2): E63-7, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27689173

RESUMEN

PURPOSE: The goal of this study was to objectively quantify cervical stiffness in misoprostol users prior to IUC insertion and at follow-up consultation to evaluate the feasibility of assessing cervical stiffness and to study the influence of misoprostol on cervical softening. MATERIALS AND METHODS: This was a cross-sectional study that evaluated 40 women who wished to use the LNG IUS. These women were evaluated immediately before LNG IUS insertion and 6 weeks later at follow-up consultation. Participants received 200 µg of misoprostol combined with 75 mg of diclofenac in a single tablet orally (Arthrotec forte 75/200(®), Pfizer, USA) 6-12 h prior to insertion in "off label" use. On both occasions, cervical stiffness was determined using a novel medical device based on the aspiration technique. The Wilcoxon rank-sum and the Wilcoxon signed-rank test were applied to compare cervical stiffness assessments at insertion of the IUD and at follow-up. RESULTS: For the first time, cervical stiffness was quantitatively assessed in misoprostol users prior to IUD insertion, proving that the aspiration technique enables detection of pharmacologically induced cervical changes, and also that misoprostol has a detectable softening effect on cervical tissue. CONCLUSION: The clinical value of the detected cervical softening after misoprostol administration remains unclear. Aspiration measurements could be helpful in searching for the ideal candidate, the appropriate route, dosage and interval of misoprostol intake prior to IUC insertion.

17.
J Mech Behav Biomed Mater ; 60: 425-437, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26990071

RESUMEN

The commercial polydimethysiloxane elastomer Sylgard(®) 184 with mixing ratio 10:1 is in wide use for biomedical research or fundamental studies of mechanobiology. In this paper, a comprehensive study of the large strain mechanical behavior of this material under multiaxial monotonic and cyclic loads, and its change during the first 26 days after preparation is reported. The equibiaxial stress response studied in inflation experiments reveals a much stiffer and more nonlinear response compared to the uniaxial and pure shear characteristics. The polymer revealed remarkably elastic behavior, in particular, very little dependence on strain rates between 0.3%/s and 11%/s, and on the strain history in cyclic experiments. On the other hand, both the small-strain and large strain nonlinear mechanical characteristics of the elastomer are changing with sample age and the results suggest that this process has not ceased after 26 days. A recent re-interpretation of the well-known Ogden model for incompressible rubber-like materials was applied to rationalize the results and accurate agreement was obtained with the experimental data over all testing configurations and testing times. The change of a single parameter in this model is shown to govern the evolution of the nonlinear material characteristics with sample age, attributed to a continuation of the cross-linking process. Based on a kinetic relation to account for this process over time, the model provided successful predictions of the material behavior even after more than one year.


Asunto(s)
Elastómeros de Silicona/química , Goma , Estrés Mecánico
18.
J Biomech ; 48(16): 4279-86, 2015 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-26584965

RESUMEN

The present study is aimed at a combined experimental and numerical investigation of the mechanical response of superficial facial tissues. Suction based experiments provide the location, time, and history dependent behavior of skin and SMAS (superficial musculoaponeurotic system) by means of Cutometer and Aspiration measurements. The suction method is particularly suitable for in vivo, multi-axial testing of soft biological tissue including a high repeatability in subsequent tests. The campaign comprises three measurement sites in the face, i.e. jaw, parotid, and forehead, using two different loading profiles (instantaneous loading and a linearly increasing and decreasing loading curve), multiple loading magnitudes, and cyclic loading cases to quantify history dependent behavior. In an inverse finite element analysis based on anatomically detailed models an optimized set of material parameters for the implementation of an elastic-viscoplastic material model was determined, yielding an initial shear modulus of 2.32kPa for skin and 0.05kPa for SMAS, respectively. Apex displacements at maximum instantaneous and linear loading showed significant location specificity with variations of up to 18% with respect to the facial average response while observing variations in repeated measurements in the same location of less than 12%. In summary, the proposed parameter sets for skin and SMAS are shown to provide remarkable agreement between the experimentally observed and numerically predicted tissue response under all loading conditions considered in the present study, including cyclic tests.


Asunto(s)
Músculos Faciales/fisiología , Adulto , Fenómenos Biomecánicos , Elasticidad , Cara/fisiología , Análisis de Elementos Finitos , Humanos , Masculino , Fenómenos Fisiológicos de la Piel
19.
Transplant Proc ; 47(7): 2156-8, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26361666

RESUMEN

BACKGROUND: After introduction of the Model for End-Stage Liver Disease (MELD) score in 2002, a worldwide increasing number of simultaneous liver-kidney transplantations (SLKTx) has been observed. However, organ shortage puts into question the allocation of 2 grafts to 1 recipient. This retrospective, single-center study compared SLKTx results with isolated liver transplantation (LTx). METHODS: Between 1995 and 2013, 37 SLKTx were performed in adult recipients. Every SLKTx was matched by donor age (±5 years) and transplantation date with 2 LTx (n = 74). Pretransplant, intraoperative, and post-transplant variables were collected; liver graft and patient survivals were calculated. RESULTS: As expected, donor age was similar in the 2 groups (median, 39.7 years), whereas serum creatinine level, glomerular filtration rate, and MELD and D-MELD (donor age*MELD) scores were significantly higher in the SLKTx group. SLKTx had longer waiting list time (P = .0034) as well as higher surgical difficulty, testified by more blood transfusions (P = .0083), increased use of classic caval reconstruction (P = .0024), and more frequent need of abdominal packing for bleeding control (P = .0003). In addition, duration of hospital stay (P < .0001), second-look surgery (P = .0082), post-transplant dialysis (P < .0001), and post-transplant infections (P = .04) were significantly greater in SLKTx group. Acute rejection episodes involving the liver were significantly less in SLKTx than in LTx (14% vs 41%; P = .0045). Liver graft and patient survival at 10 years after transplantation was similar in the 2 groups (liver graft: SLKTx, 80% vs LTx, 77% [P = .85]; patient: SLKTx, 86% vs LTx, 79% [P = .56]). CONCLUSIONS: Despite being technically challenging, SLKTx provided excellent long-term results and was shown to be an effective use of liver grafts.


Asunto(s)
Trasplante de Riñón/estadística & datos numéricos , Hepatopatías/cirugía , Trasplante de Hígado/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Obtención de Tejidos y Órganos/métodos , Adolescente , Adulto , Estudios de Casos y Controles , Terapia Combinada/métodos , Terapia Combinada/estadística & datos numéricos , Femenino , Tasa de Filtración Glomerular , Supervivencia de Injerto , Humanos , Trasplante de Riñón/métodos , Hepatopatías/patología , Trasplante de Hígado/métodos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Adulto Joven
20.
J Biomech ; 48(9): 1541-8, 2015 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-25791058

RESUMEN

Measuring the stiffness of the uterine cervix might be useful in the prediction of preterm delivery, a still unsolved health issue of global dimensions. Recently, a number of clinical studies have addressed this topic, proposing quantitative methods for the assessment of the mechanical properties of the cervix. Quasi-static elastography, maximum compressibility using ultrasound and aspiration tests have been applied for this purpose. The results obtained with the different methods seem to provide contradictory information about the physiologic development of cervical stiffness during pregnancy. Simulations and experiments were performed in order to rationalize the findings obtained with ultrasound based, quasi-static procedures. The experimental and computational results clearly illustrate that standardization of quasi-static elastography leads to repeatable strain values, but for different loading forces. Since force cannot be controlled, this current approach does not allow the distinction between a globally soft and stiff cervix. It is further shown that introducing a reference elastomer into the elastography measurement might overcome the problem of force standardization, but a careful mechanical analysis is required to obtain reliable stiffness values for cervical tissue. In contrast, the maximum compressibility procedure leads to a repeatable, semi-quantitative assessment of cervical consistency, due to the nonlinear nature of the mechanical behavior of cervical tissue. The evolution of cervical stiffness in pregnancy obtained with this procedure is in line with data from aspiration tests.


Asunto(s)
Cuello del Útero/fisiología , Fenómenos Biomecánicos , Cuello del Útero/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad , Femenino , Análisis de Elementos Finitos , Humanos , Modelos Biológicos , Fantasmas de Imagen , Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA