Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Br J Ophthalmol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39122355

RESUMEN

BACKGROUND/AIMS: Female choroideremia carriers present with a spectrum of disease severity. Unlike in men, the rate of disease progression has not been well characterised in carriers. This longitudinal study aimed to determine the rate of retinal degeneration in choroideremia carriers, using multimodal imaging and microperimetry. METHODS: Choroideremia carriers previously seen at Oxford Eye Hospital (United Kingdom) between 2012 and 2017 returned for testing between 2015 and 2023, providing up to 11 years' follow-up data. Participants had optical coherence tomography, fundus-tracked microperimetry and fundus autofluorescence (FAF) imaging performed. RESULTS: Thirty-four eyes of 17 choroideremia carriers were examined using multimodal imaging. Median age was 44 (range: 15-73) years at baseline and median follow-up duration was 7 (range: 1-11) years. At baseline, phenotype was classified as fine (n=5 eyes), coarse (n=13 eyes), geographic (n=12 eyes) or male pattern (n=4 eyes). Thirteen patients showed no change in phenotype classification, four showed slight changes associated with choroideremia-related retinal degeneration. Despite this, carriers with severe retinal phenotypes had a statistically significant decline in average retinal sensitivity (-0.7 dB and -0.8 dB per year, respectively, p<0.001), area of geographic loss defined by FAF (+2.5 mm2 and +3.7 mm2 per year, respectively, p<0.001) and thinning of the photoreceptor complex (up to -2.8 microns and -10.3 microns per year, p<0.001). CONCLUSION: Choroideremia carriers, particularly those with severe retinal phenotypes, exhibit progressive retinal degeneration, as evident by multimodal imaging biomarkers and functional testing. Clinicians should not rely on retinal severity classification alone to assess disease progression.

2.
Ophthalmol Retina ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936773

RESUMEN

PURPOSE: To describe visual function and retinal features of female carriers of choroideremia (CHM), using multimodal imaging and microperimetry. DESIGN: Cross-sectional cohort study. PARTICIPANTS AND CONTROLS: Choroideremia carriers seen in Australia (Melbourne or Perth) or the United Kingdom (Oxford or Cambridge) between 2012 and 2023. Healthy age-matched controls seen in Melbourne, Australia, between 2022 and 2023. METHODS: Participants had visual acuity, fundus-tracked microperimetry, OCT, and fundus autofluorescence imaging performed. Choroideremia carriers were either genetically or clinically confirmed (i.e., obligate carriers). Choroideremia carriers were grouped according to their retinal phenotype and compared with healthy controls. Statistical analyses were performed on StataBE (v18.0). MAIN OUTCOME MEASURES: Best-corrected visual acuity (BCVA), low-luminance visual acuity (LLVA), average retinal sensitivity, volume of macular hill of vision (HoV), inner retinal thickness, and photoreceptor complex (PRC) thickness. RESULTS: Eighty-six eyes of 43 CHM carriers and 60 eyes of 30 healthy controls were examined using multimodal imaging and microperimetry. Median age was 54 and 48.5 years for CHM carriers and controls, respectively (P = 0.18). Most CHM carriers (86%) were genetically confirmed. Choroideremia carriers and controls had strong intereye correlation between eyes for BCVA and average retinal sensitivity (P < 0.001). Low-luminance visual acuity and macular HoV tests were sensitive tests to detect changes in CHM carriers with mild phenotypes (i.e., fine and coarse). Choroideremia carriers with geographic or male-pattern phenotypes had reduced BCVA, LLVA, retinal sensitivity, and retinal thinning, compared with healthy controls. Retinal thickening of the inner retina was observed in the central 1°, despite generalized thinning of the PRC in the central 7°, indicating retinal remodeling in CHM carriers, compared with controls. There were no genotype-phenotype correlations observed. CONCLUSIONS: Female carriers of CHM with severe retinal phenotypes (i.e., geographic or male pattern) have significantly decreased visual function and retinal structural changes when compared with age-matched controls and those carriers with milder phenotypes. Low-luminance visual acuity and volumetric measures of the macular HoV were found to be the most sensitive functional tests to detect milder retinal disease (fine and coarse phenotypes) in CHM carriers. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

3.
Gene Ther ; 31(5-6): 314-323, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38565634

RESUMEN

Amidst rapid advancements in ocular gene therapy, understanding patient perspectives is crucial for shaping future treatment choices and research directions. This international cross-sectional survey evaluated knowledge, attitudes, and perceptions of ocular genetic therapies among potential recipients with inherited retinal diseases (IRDs). Survey instruments included the Attitudes to Gene Therapy-Eye (AGT-Eye), EQ-5D-5L, National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25), and Patient Attitudes to Clinical Trials (PACT-22) instruments. This study included 496 participant responses (89% adults with IRDs; 11% parents/guardians/carers) from 35 countries, with most from the United States of America (USA; 69%) and the United Kingdom (11%). Most participants (90%) indicated they would likely accept gene therapy if it was available, despite only 45% agreeing that they had good knowledge of gene therapy. The main sources of information were research registries (60% of participants) and the internet (61%). Compared to data from our recently published Australian national survey of people with IRDs (n = 694), USA respondents had higher knowledge of gene therapy outcomes, and Australian respondents indicated a higher perceived value of gene therapy treatments. Addressing knowledge gaps regarding outcomes and financial implications will be central to ensuring informed consent, promoting shared decision-making, and the eventual clinical adoption of genetic therapies.


Asunto(s)
Terapia Genética , Humanos , Terapia Genética/métodos , Adulto , Masculino , Estudios Transversales , Encuestas y Cuestionarios , Femenino , Persona de Mediana Edad , Conocimientos, Actitudes y Práctica en Salud , Enfermedades de la Retina/terapia , Enfermedades de la Retina/genética , Adulto Joven , Adolescente , Anciano , Estados Unidos
4.
Ophthalmic Epidemiol ; : 1-11, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38635874

RESUMEN

PURPOSE: Post-operative vision impairment is common among patients who have undergone cataract surgery in low-resource settings, impacting quality of clinical outcomes and patient experience. This prospective, multisite, single-armed, pragmatic validation study aimed to assess whether receiving tailored recommendations via the free Better Operative Outcomes Software Tool (BOOST) app improved surgical outcomes, as quantified by post-operative unaided distance visual acuity (UVA) measured 1-3 days after surgery. METHODS: During the baseline data collection round, surgeons in low and middle-income countries recorded clinical characteristics of 60 consecutive cataract cases in BOOST. Additional data on the causes of poor outcomes from 20 consecutive cases with post-operative UVA of <6/60 (4-12 weeks post-surgery) were entered to automatically generate tailored recommendations for improvement, before 60 additional consecutive cases were recorded during the follow-up study round. Average UVA was compared between cases recorded in the baseline study round and those recorded during follow-up. RESULTS: Among 4,233 cataract surgeries performed by 41 surgeons in 18 countries, only 2,002 (47.3%) had post-operative UVA 6/12 or better. Among the 14 surgeons (34.1%) who completed both rounds of the study (1,680 cases total), there was no clinically significant improvement in post-operative average UVA (logMAR units ±SD) between baseline (0.50 ± 0.37) and follow-up (0.47 ± 0.36) rounds (mean improvement 0.03, p = 0.486). CONCLUSIONS: Receiving BOOST-generated recommendations did not result in improved UVA beyond what could be expected from prospective monitoring of surgical outcomes alone. Additional research is required to assess whether targeted support to implement changes could potentiate the uptake of app-generated recommendations and improve outcomes.

5.
Ophthalmol Glaucoma ; 7(4): 326-334, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38369058

RESUMEN

PURPOSE: To evaluate the efficacy and safety of combined cataract surgery with insertion of an ab interno trabecular microbypass device (iStent Inject, Glaukos Corporation) compared to cataract surgery alone in patients with mild-to-moderate glaucoma. DESIGN: Prospective, randomized, assessor-masked controlled trial at a single centre. PARTICIPANTS: Eyes with visually-significant cataract and mild-to-moderate glaucoma with preoperative intraocular pressure (IOP) of 12 to 30 mmHg on 0 to 3 ocular hypotensive medications. METHODS: Participants eyes were randomized (2017-2020) 1:1 to combined cataract surgery with iStent Inject (treatment group, n = 56) or cataract surgery alone (control group, n = 48), and followed up for 2 years. MAIN OUTCOME MEASURES: The co-primary effectiveness endpoints were the number of ocular hypotensive medications and IOP at 24-months post-surgery. The secondary effectiveness endpoints were ocular comfort as measured by the Ocular Surface Disease Index (OSDI) and vision-related quality of life as measured by the Glaucoma Activity Limitation Questionnaire (GAL-9) at 24-months. Safety measures included postoperative visual acuity, any unplanned return to the operating theatre, adverse events, and complications. RESULTS: Participants (67.3% male) were aged 53 to 85 years, and treatment groups were similar in terms of mean medicated IOP (treatment group 17.7 mmHg ± 4.0; control group 17.1 mmHg ± 3.1), and number of ocular hypotensive medications (treatment group 1.69 ± 1.05; control group 1.80 ± 1.22) at baseline. At 24 months, the number of ocular hypotensive medications were 0.7 ± 0.9 in the treatment groups compared to 1.5 ± 1.9 in the control group, with an adjusted difference of 0.6 fewer medications per eye in the treatment group (95% CI 0.2-1.1, P = 0.008). In the treatment group, 57% of eyes were on no glaucoma medications compared to 36% in the control group. There was no significant difference in IOP between the 2 groups beyond the 4-weeks. There were no differences in patient-reported outcomes between the 2 groups. The visual outcomes and safety profiles were similar between the 2 groups. CONCLUSIONS: Combined cataract surgery with iStent Inject achieved a clinically- and statistically-significantly greater reduction in ocular hypotensive medication usage at 24-months compared to cataract surgery alone, with no significant difference in IOP. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Asunto(s)
Catarata , Presión Intraocular , Calidad de Vida , Agudeza Visual , Humanos , Masculino , Femenino , Estudios Prospectivos , Presión Intraocular/fisiología , Anciano , Estudios de Seguimiento , Catarata/complicaciones , Resultado del Tratamiento , Extracción de Catarata/métodos , Implantes de Drenaje de Glaucoma , Persona de Mediana Edad , Glaucoma de Ángulo Abierto/fisiopatología , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/complicaciones , Facoemulsificación/métodos , Anciano de 80 o más Años
6.
Acta Ophthalmol ; 102(5): e736-e745, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38226448

RESUMEN

PURPOSE: Economic evaluations of interventions for ocular disease require utility scores that accurately represent quality of life in the target population. This study aimed to describe the distribution of EQ-5D-5L utility values among Australian adults with symptomatic inherited retinal diseases (IRDs) and to assess the relationship between these scores and vision-related quality of life. METHODS: A survey was administered predominantly online in 2021. Participants completed the EQ-5D-5L general health utility instrument, the EQ vertical visual analogue scale (EQ-VAS) and the National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25). Self-reported IRD diagnoses were classified as being associated with central or widespread retinal involvement. RESULTS: Responses from 647 participants aged 18-93 years were included, 50.1% were men and 77.6% had an IRD associated with widespread retinal involvement. The majority reported no problems with self-care and no pain/discomfort but did report anxiety/depression and problems with work, study, housework, or family/leisure activities. Most people with widespread involvement reported problems with mobility. Median EQ-5D-5L utility was 0.88 and 0.91 among people with widespread and central involvement, respectively (age and sex-adjusted p = 0.029); and median EQ-VAS was 75 and 80, respectively (adjusted p = 0.003). A moderate curvilinear correlation was observed between EQ-5D-5L and NEI-VFQ-25 composite score (Spearman's ρ 0.69), but not all people with poor vision-related quality of life had low EQ-5D-5L utility values. CONCLUSIONS: EQ-5D-5L health utility values are correlated with vision-related quality of life among adults with IRDs. However, the EQ-5D-5L may not be sensitive to the full impact of vision impairment on quality of life.


Asunto(s)
Calidad de Vida , Enfermedades de la Retina , Humanos , Adulto , Masculino , Persona de Mediana Edad , Femenino , Anciano , Estudios Transversales , Adolescente , Adulto Joven , Australia/epidemiología , Anciano de 80 o más Años , Enfermedades de la Retina/fisiopatología , Enfermedades de la Retina/psicología , Enfermedades de la Retina/diagnóstico , Encuestas y Cuestionarios , Estado de Salud , Agudeza Visual/fisiología , Perfil de Impacto de Enfermedad , Años de Vida Ajustados por Calidad de Vida
7.
Eye (Lond) ; 38(4): 698-706, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37731049

RESUMEN

BACKGROUND: The validity of findings from epidemiological studies using self-report of ophthalmic conditions depends on several factors. We assessed the diagnostic accuracy of self-reported age-related macular degeneration (AMD) among older Australians enroled in a primary prevention clinical trial and compared diagnostic accuracy between demographic subgroups. METHODS: At baseline (2010-2015), Australian sub-study participants of the ASPirin in Reducing Events in the Elderly (ASPREE) trial, underwent bilateral two-field, 45° non-mydriatic colour retinal photography. Beckman classification of any-stage AMD was used as the reference standard diagnosis. Participants were asked whether a doctor had ever diagnosed them with "macular degeneration" (the index test) via a paper-based questionnaire as part of the ASPREE Longitudinal Study of Older Persons (ALSOP) within the first year of enrolment. RESULTS: In total, 4193 participants were included (aged 70-92 years, 50.8% female). Of those, 262 (6.3%) reported having AMD and 92 (2.2%) were unsure. Retinal grading detected 2592 (61.8%) with no AMD, 867 (20.7%) with early, 686 (16.4%) with intermediate and 48 (1.1%) with late AMD (n = 1601 with any-stage AMD, 38.2%). Self-reported AMD had 11.4% sensitivity (95% CI 9.9-13.1) and 96.9% specificity (95% CI 96.2-97.6) for any-stage AMD, with 69.8% and 63.9% positive and negative predictive values. Sensitivity was higher among participants with late-stage AMD (87.5%), older participants (26.8%), and those with poorer vision (41.0%). CONCLUSIONS: Although most participants with late-stage AMD were aware of having AMD, the majority with early and intermediate AMD were not. Therefore, findings from studies that rely on disease self-report should be interpreted with caution.


Asunto(s)
Pueblos de Australasia , Degeneración Macular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Australia/epidemiología , Estudios Longitudinales , Degeneración Macular/diagnóstico , Degeneración Macular/epidemiología , Autoinforme
8.
Clin Exp Optom ; : 1-8, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38057280

RESUMEN

CLINICAL RELEVANCE: Understanding what aspects of vision or binocular vision may affect learning, and how these are assessed, is important for the eye health care professional assessing children with learning difficulties. It is vital that visual dysfunction is identified or excluded in these patients to ensure targeted and timely intervention. BACKGROUND: The aim of this study was to investigate similarities and differences between eye care professionals in the knowledge, attitudes and practice patterns, when evaluating children with learning difficulties. METHODS: This study was a cross-occupational, cross-sectional, predominantly quantitative internet-based survey. Ophthalmologists, optometrists, and orthoptists working in Australia were eligible to participate. A questionnaire comprising of 31 multiple-choice questions with up to 19 additional branching questions was distributed using REDCap in September 2022. RESULTS: A total of 130 responses were analysed (6 ophthalmologists, 84 orthoptists and 40 optometrists of whom 9 were practicing behavioural vision care). Most respondents assessed distance visual acuity (95%), near stereoacuity (85%), presence of strabismus (88%) and ocular movements (91%). Near vision was assessed less often (65%). Optometrists were most likely to measure colour vision (p < 0.002), accommodation and undertake a subjective refraction (each p < 0.001). Ophthalmologists were least likely to measure convergence (p = 0.041) but more likely to undertake a cycloplegic refraction (p = 0.044). More optometrists practicing behavioural vision care reported testing binocular vision (p = 0.026), fusional vergence (p < 0.001), saccades (p = 0.066), and smooth pursuit (p = 0.050) than other professions. There was a positive correlation between frequency and confidence level when assessing children with learning difficulties (ρ = 0.64). Respondents referred to paediatricians (39%), speech pathologists (30%), educational psychologists (29%) and general practitioners (29%). CONCLUSION: Despite similarities across occupations, there were differences in testing the vision and binocular functions of children with learning difficulties. Future research should aim to establish minimum standards for assessing this patient cohort to ensure consistent and relevant assessment.

9.
J Glaucoma ; 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38031295

RESUMEN

OBJECTIVE: Timely detection of glaucoma is key to preventing or delaying vision loss. This study aimed to assess whether the routine use of optical coherence tomography (OCT) by optometrists for detection of glaucomatous changes in the optic nerve and retina increased glaucoma referrals to ophthalmologists. DESIGN: This study was a retrospective review of routinely-collected electronic medical records of patients from a chain of 331 optometry practices in Australia. PARTICIPANTS: Electronic medical records were reviewed for every patient aged 18-99 years who attended an included practice between January 1 and July 31, 2019. METHODS: Odds of referral for glaucoma assessment were compared between practices performing OCT routinely on all patients (OCT practices, n=175) and without OCT (non-OCT practices, n=20). A subset of referrals were assessed by ophthalmologists to determine the false positive referral rate. MAIN OUTCOME MEASURES: The primary outcome measure of this study was referral to an ophthalmologist for glaucoma assessment. A secondary outcome was the rate of false positive referrals, analysed in a subset of patients referred for glaucoma assessment. RESULTS: Records from 994,461 patients (59% female) were included and 10,475 (1.1%) were referred for glaucoma assessment. Most referrals were associated with normal intraocular pressure (non-OCT practices: n=496, 66%; OCT practices: n=6,603, 68%). Referral for glaucoma was higher in OCT practices (n=9,719, 1.1%) compared to non-OCT practices (n=756, 0.8%, age-, gender- and location-adjusted odds ratio 1.39, 95% confidence interval 1.10-1.76). Of 318 referred patients (3%, all from OCT practices) for whom ophthalmologist feedback was available, 68 (21%) were considered not to have glaucoma. CONCLUSIONS: The routine use of OCT in optometric practice may lead to more timely glaucoma detection and prevention of avoidable vision loss.

10.
Clin Exp Ophthalmol ; 51(5): 413-424, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37114419

RESUMEN

BACKGROUND: We aimed to describe the self-reported level of eyesight amongst a cohort of relatively healthy older Australian adults, and to investigate associations between poorer self-rated eyesight and demographic, health, and functional characteristics METHODS: The ASPirin in Reducing Events in the Elderly (ASPREE) Longitudinal Study of Older Persons (ALSOP) study was embedded in a multisite trial which recruited independently living Australians from general practices (2010-2014). Self-rated eyesight was recorded on a paper-based questionnaire as Excellent, Good, Fair, Poor, Very poor, or Completely blind at the baseline study wave RESULTS: Data from 14 592 participants (aged 70-95 years, 54.61% female) were included in this cross-sectional analysis. Eighty percent of participants reported excellent or good eyesight (n = 11 677). People with complete blindness were precluded from enrolling but 299 participants (2.0%) reported poor or very poor eyesight, and 2616 rated their eyesight as fair (17.9%). Lower levels of eyesight were associated with being older, female, fewer years of formal education, a primary language other than English, smoking, and self-reported macular degeneration, glaucoma, retinopathy, cataracts, and hearing problems (each p ≤ 0.021). People with lower levels of eyesight had a higher number of falls, frailty characteristics, and depressive symptoms, and lower mental and physical health functioning scores (each p < 0.001) CONCLUSIONS: Whilst most of these healthy older Australians reported good or excellent eyesight, a notable minority reported poor or very poor eyesight, and this was associated with a range of poorer health measures. These findings support the need for additional resources to prevent vision loss and associated sequelae.


Asunto(s)
Estado de Salud , Trastornos de la Visión , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Australia/epidemiología , Estudios Transversales , Estudios Longitudinales , Visión Ocular , Autoinforme , Trastornos de la Visión/epidemiología
11.
Semin Ophthalmol ; 38(6): 592-597, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36760065

RESUMEN

BACKGROUND: Traditionally, visual acuity gain and central retinal thickness have been used to measure outcomes when investigating the efficacy of vascular endothelial growth factor (VEGF) inhibitors for patients with neovascular age-related macular degeneration (nARMD). However, localization of retinal fluid may offer additional prognostic value for treatment. The primary aim of this retrospective clinical audit was to investigate whether the presence and location of subretinal fluid has an effect on the visual outcomes of treatment naïve patients with nARMD treated in the real-world setting with VEGF inhibitors. Secondary aims included investigation of change to visual and anatomical outcomes and investigation of the dosing schedule. METHODS: Retrospective observational study of patients attending one suburban and one regional ophthalmology clinic requiring treatment with VEGF inhibitors for nARMD using single-user non-identifiable data from the Fight Retinal Blindness! Registry from 2014 to 2020. Visual acuity (VA) and central subfield thickness (CST) were recorded at baseline, 3, 6, 12 and 24 months. RESULTS: Forty-nine eyes of 42 treatment naïve patients were included for analysis (aged 62-89 years). Almost half (49%) presented with a combination of intra- and subretinal fluid at baseline. Intraretinal fluid was present in 75% of eyes but decreased to 22.7% of eyes by 24 months. VA at baseline was 55 letters, and this improved by 6 letters. The change in VA from baseline to 3, 6 and 12 months was statistically significant (p < .05). The mean change in CST from baseline to 3 months was significant (-76 µm). This change was also observed at the other milestones (p < .001). CONCLUSIONS: The findings of this study suggest that allowing some subretinal fluid to remain will not affect treatment outcomes.


Asunto(s)
Degeneración Macular , Degeneración Macular Húmeda , Humanos , Ranibizumab/uso terapéutico , Inhibidores de la Angiogénesis/uso terapéutico , Factor A de Crecimiento Endotelial Vascular , Estudios Retrospectivos , Resultado del Tratamiento , Retina , Degeneración Macular/tratamiento farmacológico , Inyecciones Intravítreas , Degeneración Macular Húmeda/diagnóstico , Degeneración Macular Húmeda/tratamiento farmacológico
12.
Am J Hum Genet ; 110(1): 170-176, 2023 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-36565701

RESUMEN

Pedigree analysis showed that a large proportion of Leber hereditary optic neuropathy (LHON) family members who carry a mitochondrial risk variant never lose vision. Mitochondrial haplotype appears to be a major factor influencing the risk of vision loss from LHON. Mitochondrial variants, including m.14484T>C and m.11778G>A, have been added to gene arrays, and thus many patients and research participants are tested for LHON mutations. Analysis of the UK Biobank and Australian cohort studies found more than 1 in 1,000 people in the general population carry either the m.14484T>C or the m.11778G>A LHON variant. None of the subset of carriers examined had visual acuity at 20/200 or worse, suggesting a very low penetrance of LHON. Haplogroup analysis of m.14484T>C carriers showed a high rate of haplogroup U subclades, previously shown to have low penetrance in pedigrees. Penetrance calculations of the general population are lower than pedigree calculations, most likely because of modifier genetic factors. This Matters Arising Response paper addresses the Watson et al. (2022) Matters Arising paper, published concurrently in The American Journal of Human Genetics.


Asunto(s)
ADN Mitocondrial , Atrofia Óptica Hereditaria de Leber , Humanos , Penetrancia , ADN Mitocondrial/genética , Atrofia Óptica Hereditaria de Leber/genética , Australia/epidemiología , Mutación/genética , Linaje
14.
Clin Exp Optom ; 106(3): 271-275, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35156536

RESUMEN

CLINICAL RELEVANCE: Although melanocytic choroidal tumours of the choroid are a common eye pathology, no standardised protocol exists for their management in the community. BACKGROUND: Choroidal naevi are found in approximately 6% of the adult White population, whereas choroidal melanomas are rare, with an annual incidence of 5-10/million/year. Multimodal imaging has advanced the understanding of malignancy imaging biomarkers, but distinguishing between a small melanoma and naevus remains difficult and an algorithm for their management by community practitioners has not been uniformly adopted. One of the authors (BD) devised the MOLES scoring system, which indicates malignancy likelihood according to mushroom shape, orange pigment, large size, enlargement, and subretinal fluid. When applied by ocular oncologists, the system accurately distinguishes choroidal naevi from melanomas. The aim of this study was to evaluate whether community optometrists can appropriately manage patients with melanocytic choroidal tumours using this system. METHODS: Clinical images of 25 melanocytic choroidal tumours were presented in an online survey, including colour fundus photographs, fundus autofluorescence, optical coherence tomography, and B-scan ultrasound images. Using the MOLES system, 39 optometrists diagnosed tumours as naevus or probable melanoma and decided between community monitoring and ophthalmologist referral. Responses were compared to MOLES grading of the same clinical images by ocular oncologists. RESULTS: Using MOLES, optometrists correctly identified 389/406 probable melanomas (95.8% sensitivity) and 331/516 choroidal naevi (64.1% specificity); correctly referred 773/778 tumours to an ophthalmologist (99.4% sensitivity); and correctly managed 80/144 lesions (55.6% specificity) in the community. CONCLUSION: Optometrists safely applied the MOLES scoring system in this survey. Further measures are indicated to reduce choroidal naevi over-referral and evaluate MOLES system usage in clinical optometric practice, where some imaging modalities may not be readily available.


Asunto(s)
Neoplasias de la Coroides , Melanoma , Topos , Nevo Pigmentado , Optometristas , Neoplasias Cutáneas , Adulto , Humanos , Animales , Neoplasias de la Coroides/diagnóstico , Neoplasias de la Coroides/terapia , Nevo Pigmentado/diagnóstico , Nevo Pigmentado/terapia , Nevo Pigmentado/patología , Melanoma/diagnóstico , Melanoma/terapia , Coroides/patología , Neoplasias Cutáneas/patología
15.
Gene Ther ; 30(3-4): 336-346, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36183012

RESUMEN

Many gene therapies are in development for treating people with inherited retinal diseases (IRD). We hypothesized that potential recipients of gene therapy would have knowledge gaps regarding treatment. We aimed to assess knowledge, attitudes, and perceptions of genetic therapies among potential recipients with IRD, using a novel instrument we designed (Attitudes to Gene Therapy-Eye (AGT-Eye)) and their associations with demographic data, self-reported visual status, and tools assessing quality of life and attitudes toward clinical trials using a community-based cross-sectional survey of Australian adults with IRD. AGT-Eye, overall quality of life EQ-5D-5L, National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25) and Patient Attitudes to Clinical Trials (PACT-22) instruments were administered. Six hundred and eighty-one people completed the study, 51.7% women of mean age 53.5 years (SD ± 15.8). Most participants (91.6%) indicated they would likely accept gene therapy if it was available to them or family members. However, only 28.3% agreed that they had good knowledge of gene therapy. Most obtained information about gene therapy from the internet (49.3%). Respondents with post-graduate degrees scored highest compared to other educational levels on methods (p < 0.001) and outcomes (p = 0.003) and were more likely to see economic value of treatment (p = 0.043). Knowledge gaps were present regarding methods and outcomes of gene therapy. This survey has shown high level of interest in the IRD community for gene therapies, and highlights areas for improved clinician and patient education.


Asunto(s)
Calidad de Vida , Enfermedades de la Retina , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Transversales , Australia , Enfermedades de la Retina/genética , Enfermedades de la Retina/terapia , Encuestas y Cuestionarios , Retina
16.
Transl Vis Sci Technol ; 11(9): 4, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36066322

RESUMEN

Purpose: The electrode to retina (ER) distance is an important contributory factor to the safety and efficacy of a suprachoroidal retinal prosthesis. Measuring ER distance may be performed by different observers during multisite studies. The aim of this study was to assess the interobserver agreement in measuring ER distance. Methods: Three independent, trained observers measured ER distance from the center of each suprachoroidal electrode to the inner retinal pigment epithelium in spectral-domain optical coherence tomography (SD-OCT) B-scans. A total of 121 ER distance measurements from 77 B-scans collected over 5 months from one subject implanted with a second-generation 44-channel suprachoroidal retinal prosthesis (NCT03406416) were made by each observer. Results: ER distance ranged from 208 to 509 µm. Pearson's correlation coefficient (ρ) showed agreement of 0.99 (95% confidence interval [CI] = 0.98-0.99) in measuring ER for each pairwise comparison. The mean difference in ER distance between observers ranged from 2.4 to 6.4 µm with pairwise limits of agreement (95% CI) of ±20 µm (5.5% of mean). Intraclass correlation coefficient (ICC) showed agreement of 0.98 (95% CI = 0.97-0.99) between observers. Conclusions: There is high agreement in measuring ER distances for suprachoroidal retinal prostheses using our systematic approach between multiple, trained observers, supporting the use of a single observer for each image. Translational Relevance: High interobserver agreement outcomes indicate that multiple, trained observers can be used to take ER measurements across different images in suprachoroidal retinal prosthesis studies. This improves multisite study efficiency and gives confidence in interpreting results relating to the safety and efficacy of suprachoroidal retinal prostheses.


Asunto(s)
Prótesis Visuales , Electrodos , Humanos , Variaciones Dependientes del Observador , Retina/diagnóstico por imagen , Retina/cirugía , Tomografía de Coherencia Óptica/métodos
17.
Transl Vis Sci Technol ; 11(6): 12, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35696133

RESUMEN

Purpose: To report the long-term observations of the electrode-tissue interface and perceptual stability in humans after chronic stimulation with a 44-channel suprachoroidal retinal implant. Methods: Four subjects (S1-4) with end-stage retinitis pigmentosa received the implant unilaterally (NCT03406416). Electrode impedances, electrode-retina distance (measured using optical coherence tomography imaging), and perceptual thresholds were monitored up to 181 weeks after implantation as the subjects used the prosthesis in the laboratory and in daily life. Stimulation charge density was limited to 32 µC/cm2 per phase. Results: Electrode impedances were stable longitudinally. The electrode-retina distances increased after surgery and then stabilized, and were well-described by an asymptotic exponential model. The stabilization of electrode-retina distances was variable between subjects, stabilizing after 45 weeks for S1, 63 weeks for S2, and 24 weeks for S3 (linear regression; Pgradient > 0.05). For S4, a statistically significant increase in electrode-retina distance persisted (P < 0.05), but by the study end point the rate of increase was clinically insignificant (exponential model: 0.33 µm/wk). Perceptual electrical thresholds were stable in one subject, decreased over time in two subjects (linear model; P < 0.05), and increased slightly in one subject but remained within the predefined charge limits (P = 0.02). Conclusions: Chronic stimulation with the suprachoroidal retinal prosthesis over 3 years resulted in stable impedances, small individual changes in perceptual electrical thresholds, and no clinically significant increase in electrode-retina distances after a period of settling after surgery. Translational Relevance: Chronic stimulation with the 44-channel suprachoroidal retinal implant with a charge density of up to 32 µC/cm2 per phase is suitable for long-term use in humans.


Asunto(s)
Retinitis Pigmentosa , Prótesis Visuales , Estimulación Eléctrica/métodos , Humanos , Microelectrodos , Retina/diagnóstico por imagen , Retina/cirugía , Retinitis Pigmentosa/cirugía
18.
Ophthalmology ; 129(10): 1192-1215, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35597519

RESUMEN

TOPIC: To evaluate the efficacy and safety of interventions for treating eye strain related to computer use relative to placebo or no treatment. CLINICAL RELEVANCE: Computer use is pervasive and often associated with eye strain, referred to as computer vision syndrome (CVS). Currently, no clinical guidelines exist to help practitioners provide evidence-based advice about CVS treatments, many of which are marketed directly to patients. This systematic review and meta-analysis was designed to help inform best practice for eye care providers. METHODS: Eligible randomized controlled trials (RCTs) were identified in Ovid MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, and trial registries, searched from inception through November 23, 2021. Eligible studies were appraised for risk of bias and were synthesized. The certainty of the body of evidence was judged using the Grading of Recommendations, Assessment, Development, and Evaluation system. Standardized mean differences (SMDs) were used when differently scaled measures were combined. RESULTS: Forty-five RCTs, involving 4497 participants, were included. Multifocal lenses did not improve visual fatigue scores compared with single-vision lenses (3 RCTs; SMD, 0.11; 95% confidence interval [CI], -0.14 to 0.37; P = 0.38). Visual fatigue symptoms were not reduced by blue-blocking spectacles (3 RCTs), with evidence judged of low certainty. Relative to placebo, oral berry extract supplementation did not improve visual fatigue (7 RCTs; SMD, -0.27; 95% CI, -0.70 to 0.16; P = 0.22) or dry eye symptoms (4 RCTs; SMD, -0.10; 95% CI, -0.54 to 0.33; P = 0.65). Likewise, berry extract supplementation had no significant effects on critical flicker-fusion frequency (CFF) or accommodative amplitude. Oral omega-3 supplementation for 45 days to 3 months improved dry eye symptoms (2 RCTs; mean difference [MD], -3.36; 95% CI, -3.63 to -3.10 on an 18 unit scale; P < 0.00001) relative to placebo. Oral carotenoid supplementation improved CFF (2 RCTs; MD, 1.55 Hz; 95% CI, 0.42 to 2.67 Hz; P = 0.007) relative to placebo, although the clinical significance of this finding is unclear. DISCUSSION: We did not identify high-certainty evidence supporting the use of any of the therapies analyzed. Low-certainty evidence suggested that oral omega-3 supplementation reduces dry eye symptoms in symptomatic computer users.


Asunto(s)
Astenopía , Síndromes de Ojo Seco , Astenopía/etiología , Astenopía/terapia , Carotenoides , Computadores , Síndromes de Ojo Seco/tratamiento farmacológico , Anteojos , Humanos
19.
J Binocul Vis Ocul Motil ; 72(2): 77-85, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35157567

RESUMEN

PURPOSE: The World Health Organization's Package of Eye Care Interventions (PECI) aims to support incorporation of amblyopia detection and treatment into health service provision. The aim of this study was to systematically review clinical practice guidelines (CPGs) for amblyopia to inform the development of this package. METHODS: MEDLINE, Embase, CINAHL and Global Index Medicus databases, guideline databases and professional body websites were searched for CPGs published in English between 2010 and 9th March 2020. Guidelines were assessed using the AGREE II tool. RESULTS: Five CPGs from North America published between 2017-2019 were identified. One CPG provided recommendations on amblyopia treatment and four focused on amblyopia detection and assessment. Non-specialist screening for amblyopic risk factors was recommended in children aged 3-5 years. At least one comprehensive eye examination was recommended for infants and children aged 0-5 years. Treatment recommendations consisted of refractive correction followed by occlusion or cycloplegic penalization. CONCLUSIONS: Additional evidence is required to compare the benefits and limitations of comprehensive eye examinations for asymptomatic children to those from screening programs. Identified CPGs were produced in high-resource countries and may not be readily applied in lower resource settings where the PECI has the greatest potential to improve service provision.


Asunto(s)
Ambliopía , Ambliopía/diagnóstico , Ambliopía/terapia , Niño , Bases de Datos Factuales , Atención a la Salud , Humanos , Lactante , Examen Físico
20.
Transl Vis Sci Technol ; 11(2): 14, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35133402

RESUMEN

PURPOSE: To assess the measurement properties of the Attitudes to Gene Therapy for the Eye (AGT-Eye) instrument among Australian adults with inherited retinal diseases (IRDs) and parents/caregivers of people with IRDs. Constructs of interest included sources of information, knowledge of treatment methods, awareness of treatment outcomes, and perceived value of gene therapy for IRDs. METHODS: A cross-sectional, self-reported, 30-item questionnaire was administered in English from January to June 2021. It was predominantly conducted online with phone and paper alternatives available. Rating scale models were generated separately for each of the four subscales to assess fit, discrimination, and differential item functioning of the items, as well as targeting, reliability, and precision of the subscales. Principal components analysis was used to assess dimensionality. RESULTS: Responses from 681 participants (87.1% online, 12.9% phone/mail) were included (ages 18-93 years; 51.7% female). Removal of two poorly performing items slightly improved subscale properties. Item reliability was high for each of the subscales; however, person reliability was suboptimal, with limited ability to stratify participants according to traits (person separation coefficient < 1.8 for each subscale). There was no evidence of differential item functioning by gender, online completion, or patient/caregiver status. Evidence of multidimensionality was detected for two subscales. CONCLUSIONS: Four subscales of the AGT-Eye will be used to analyze operational knowledge and perceived value of ocular gene therapy in Australia. Measurement properties may be improved with the generation of additional items. TRANSLATIONAL RELEVANCE: Physicians can use the AGT-Eye to assess knowledge and expectations of potential recipients of ocular gene therapy for IRDs.


Asunto(s)
Enfermedades de la Retina , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Actitud , Australia , Estudios Transversales , Femenino , Terapia Genética , Humanos , Masculino , Persona de Mediana Edad , Psicometría/métodos , Reproducibilidad de los Resultados , Enfermedades de la Retina/genética , Enfermedades de la Retina/terapia , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA