Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Catheter Cardiovasc Interv ; 95(4): 726-733, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31815357

RESUMEN

BACKGROUND: Carotid artery (CA) and axillary artery (AA) access are increasingly used for transcatheter stenting of the patent ductus arteriosus (PDA), although reports are limited. METHODS: The Congenital Catheterization Research Collaborative (CCRC) reviewed multicenter data from infants who underwent PDA stenting via the CA or AA approach from 2008 to 2017, and compared outcomes to those of infants undergoing PDA stenting via the femoral artery (FA) approach. Post-procedure ultrasound (US) imaging was reviewed. RESULTS: Forty-nine infants underwent PDA stenting from the CA (n = 43) or AA (n = 6) approach, compared with 55 infants who underwent PDA stenting from the FA approach. The PDA was the sole pulmonary blood flow (PBF) source in 61% of infants in the CA/AA cohort, compared with 33% of the FA cohort (p < .01). Ductal tortuosity for CA/AA cohort was Type I (straight) in 10 (20%), Type II (one turn) in 17 (35%), and Type III (multiple turns) in 22 (45%) infants and reflected a greater degree of tortuosity when compared to the FA cohort (p < .01). In 17 infants with CA/AA approach, the "flip technique" was used, and was associated with shorter procedure times for highly tortuous PDA (Type III) patients. Rates of procedural complications were similar across access sites. Most common complications were access site injury (thrombus or bleeding) and stent malposition. No complications were specifically related to the "flip technique." CONCLUSIONS: Use of CA and AA approach for PDA stenting was found to be more commonly employed in sole source PBF and highly tortuous PDAs. Procedural modifications such as the "flip technique" may lead to shorter procedure times. CA and AA approaches are associated with a similar burden of procedural or late complications. Post-procedural surveillance of the CA and AA is suggested, given the incidence of vascular findings on US.


Asunto(s)
Arteria Axilar , Cateterismo Cardíaco/instrumentación , Arterias Carótidas , Cateterismo Periférico , Conducto Arterioso Permeable/terapia , Arteria Femoral , Cuidados Paliativos , Circulación Pulmonar , Stents , Arteria Axilar/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Arterias Carótidas/diagnóstico por imagen , Cateterismo Periférico/efectos adversos , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Recién Nacido , Masculino , Punciones , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Intervencional , Estados Unidos
2.
Circ Cardiovasc Interv ; 10(9)2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28851718

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) is an established therapy for dysfunctional right ventricular (RV) outflow tract conduits. TPVR in patients with congenitally corrected transposition of the great arteries, subpulmonary left ventricle, and left ventricular outflow tract (LVOT) conduit dysfunction has not been studied. Unique anatomic and physiological aspects of this population may contribute to distinct risks and outcomes. METHODS AND RESULTS: Across 10 US centers, 27 patients with a dysfunctional LVOT conduit were evaluated in the catheterization laboratory between December 2008 and August 2015 with the intent to perform TPVR. TPVR was successful in 23 patients (85%). Five serious adverse events occurred in 4 cases (15%), including pulmonary hemorrhage, hypotension requiring vasoactive support, conduit disruption requiring covered stent (n=2), and acute RV dysfunction with flash pulmonary edema. After TPVR, the LVOT peak systolic ejection gradient decreased from median of 35 to 17 mm Hg (P<0.001); pulmonary insufficiency was trivial/none in all but 1 patient, where it was mild. Worsening of systemic RV dysfunction or tricuspid regurgitation was seen in 12 patients (57%) and was associated with a significantly lower post-TPVR LVOT peak systolic ejection gradient (median 17 versus 21 mm Hg; P=0.02) and higher post-TPVR RV sphericity index (median 0.88 versus 0.52; P=0.004). Post-TPVR, there were 2 late deaths because of RV failure and 1 cardiac transplantation because of progressive RV dysfunction and tricuspid regurgitation. CONCLUSIONS: TPVR in dysfunctional LVOT conduits is feasible but associated with an important rate of TPV nonimplantation and procedural serious adverse events. Worsening systemic RV function and tricuspid regurgitation may develop after LVOT TPVR.


Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Ventrículos Cardíacos/cirugía , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Transposición de los Grandes Vasos/cirugía , Función Ventricular Izquierda , Adolescente , Adulto , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Niño , Transposición Congénitamente Corregida de las Grandes Arterias , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/mortalidad , Insuficiencia de la Válvula Pulmonar/fisiopatología , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/mortalidad , Transposición de los Grandes Vasos/fisiopatología , Resultado del Tratamiento , Estados Unidos , Función Ventricular Derecha , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA