Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
2.
JACC Cardiovasc Interv ; 17(11): 1340-1351, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866457

RESUMEN

BACKGROUND: The etiology of transcatheter aortic valve (TAV) degeneration is poorly understood, particularly noncalcific mechanisms. OBJECTIVES: The authors sought to investigate noncalcific and calcific mechanisms of TAV degeneration and evaluate their impact on leaflet function by bench testing, imaging, and histology. METHODS: TAV explants were obtained from the EXPLANT THV registry and clinical institutions. Hydrodynamic assessment was performed using a heart valve pulse duplicator system under physiological conditions. Micro-computed tomography, high-resolution photography, high speed video, and hematoxylin and eosin staining were used to evaluate the morphological appearance, leaflet kinematics, and calcium burden of TAVs. RESULTS: A total of 14 explants were evaluated: 10 self-expanding CoreValve/Evolut TAVs (Medtronic), 3 balloon-expandable SAPIEN 3 TAVs (Edwards Lifesciences), and 1 mechanically expandable Lotus TAV (Boston Scientific). The median patient age at explantation was 73.0 years (Q1-Q3: 64.5-80.0 years), with a time to explantation of 4 years 1 month (1 year 5 months to 4 years 11 months). Six TAV explants were found to have leaflet calcification (162.4 mm3; 58.8-603.0 mm3), and 8 had no calcification detectable by micro-computed tomography and histology. All samples had impaired leaflet kinematics. There was no significant difference in the hydrodynamic mean gradient between calcified (47.2 mm Hg; 26.6-74.1 mm Hg) and noncalcified (27.6 mm Hg; 15.2-36.7 mm Hg; P = 0.28) TAVs. Leaflet calcification had a weak but nonsignificant association with the hydrodynamic mean gradient (r = 0.42; P = 0.14). CONCLUSIONS: TAV function can be severely impacted by noncalcific and calcific mechanisms of tissue degeneration. Importantly, functional stenosis can occur in TAVs in the absence of obvious and significant calcification.


Asunto(s)
Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Hidrodinámica , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Microtomografía por Rayos X , Humanos , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Calcinosis/cirugía , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Persona de Mediana Edad , Factores de Tiempo , Remoción de Dispositivos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Fenómenos Biomecánicos , Ensayo de Materiales , Grabación en Video
3.
J Synchrotron Radiat ; 31(Pt 4): 698-705, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38900459

RESUMEN

During beam time at a research facility, alignment and optimization of instrumentation, such as spectrometers, is a time-intensive task and often needs to be performed multiple times throughout the operation of an experiment. Despite the motorization of individual components, automated alignment solutions are not always available. In this study, a novel approach that combines optimisers with neural network surrogate models to significantly reduce the alignment overhead for a mobile soft X-ray spectrometer is proposed. Neural networks were trained exclusively using simulated ray-tracing data, and the disparity between experiment and simulation was obtained through parameter optimization. Real-time validation of this process was performed using experimental data collected at the beamline. The results demonstrate the ability to reduce alignment time from one hour to approximately five minutes. This method can also be generalized beyond spectrometers, for example, towards the alignment of optical elements at beamlines, making it applicable to a broad spectrum of research facilities.

5.
Catheter Cardiovasc Interv ; 104(1): 105-114, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38819623

RESUMEN

BACKGROUND: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry. AIM: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves. METHODS: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post-TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area-derived annular diameter, and performance of pre-dilation and post-dilation. RESULTS: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post-dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post-dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post-TAVR mean gradient (r = -0.324, p < 0.001). CONCLUSION: Relative stent expansion ≥90% was associated with the performance of post-dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Femenino , Masculino , Estudios Retrospectivos , Anciano de 80 o más Años , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Valvuloplastia con Balón/efectos adversos , Factores de Riesgo , Estados Unidos , Stents
6.
Can J Cardiol ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38797283

RESUMEN

BACKGROUND: The transcaval (TCv) vascular approach is increasingly used in transcatheter aortic valve replacement (TAVR) in patients unsuitable for the gold-standard transfemoral approach. We aimed to evaluate the efficacy, safety, and clinical outcomes associated with TCv-TAVR. METHODS: A systematic review and meta-analysis was conducted by searching PubMed/Medline, Embase, and the Cochrane Library for all articles assessing the TCv approach published through December 2023. Outcomes included 30-day and 1-year all-cause mortality (ACM), 30-day rehospitalisation, perioperative complications and postoperative complications at 30 days. The meta-analysis was registered on the PROSPERO database with the identifier CRD42024501921. RESULTS: A total of 8 studies with 467 patients were included. TCv-TAVR procedures achieved a success rate of 98.5%. TCv-TAVR was associated with a 30-day ACM rate of 6.1% (95% confidence interval [CI]: 3.9%-8.2%), a 1-year ACM rate of 14.9% (95% CI 2.3%-27.6%) and a 30-day rehospitalisation rate of 4.2% (95% CI -2.2% to 10.6%). Postoperative stroke or transient ischemic attack, major vascular complications, and major or life-threatening bleeding occurred in 3.3%, 8.7%, and 7.5% of cases, respectively. Cumulative meta-analyses showed a temporal trend of decreasing rates of vascular complications. CONCLUSIONS: The TCv approach in TAVR demonstrated a reassuring efficacy and safety profile, with mortality and postoperative complication rates similar to those reported for supra-aortic alternative TAVR access routes. The temporal decrease in vascular complications suggests potential improvements in procedural techniques and device technology. These findings further support the TCv approach as a viable option in patients ineligible for the transfemoral access. PROSPERO: CRD42024501921.

7.
Rev Med Suisse ; 20(875): 1020-1025, 2024 May 22.
Artículo en Francés | MEDLINE | ID: mdl-38783671

RESUMEN

Coronary Computed Tomography Angiography (CCTA) has now become an established tool in the diagnostic process for patients suspected of coronary artery disease. In light of rapid technological development, CCTA has evolved into an imaging modality providing both anatomical and functional information to guide patient management. In this article, we describe the role of cardiac CT in assessing atherosclerotic plaque, chest pain evaluation, cardiovascular risk stratification, planning and guiding coronary intervention, as well as structural heart diseases.


Le scanner coronarien est actuellement un outil reconnu dans le processus diagnostique des patients chez qui on suspecte une maladie coronarienne. Bénéficiant d'un développement technologique rapide et procurant des informations tant morphologiques que fonctionnelles, le CT cardiaque devient une modalité d'imagerie incontournable pour orienter la prise en charge des patients. Dans cet article, nous décrivons le rôle du CT cardiaque dans l'évaluation de la plaque d'athérosclérose, des douleurs thoraciques, de la stratification du risque cardiovasculaire, de la planification et du guidage de l'intervention coronarienne, ainsi que des maladies cardiaques structurelles.


Asunto(s)
Dolor en el Pecho , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Humanos , Angiografía por Tomografía Computarizada/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico , Dolor en el Pecho/etiología , Dolor en el Pecho/diagnóstico por imagen , Angiografía Coronaria/métodos , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico , Medición de Riesgo/métodos , Cardiopatías/diagnóstico por imagen , Cardiopatías/diagnóstico
8.
J Clin Med ; 13(5)2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38592316

RESUMEN

Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.

9.
Int J Mol Sci ; 25(7)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38612836

RESUMEN

One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient's immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve's ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Animales , Porcinos , Humanos , Niño , Xenoinjertos , Trasplante Heterólogo , Ingeniería de Tejidos
10.
EuroIntervention ; 20(8): e496-e503, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38629422

RESUMEN

BACKGROUND: Multidisciplinary Heart Teams (HTs) play a central role in the management of valvular heart diseases. However, the comprehensive evaluation of patients' data can be hindered by logistical challenges, which in turn may affect the care they receive. AIMS: This study aimed to explore the ability of artificial intelligence (AI), particularly large language models (LLMs), to improve clinical decision-making and enhance the efficiency of HTs. METHODS: Data from patients with severe aortic stenosis presented at HT meetings were retrospectively analysed. A standardised multiple-choice questionnaire, with 14 key variables, was processed by the OpenAI Chat Generative Pre-trained Transformer (GPT)-4. AI-generated decisions were then compared to those made by the HT. RESULTS: This study included 150 patients, with ChatGPT agreeing with the HT's decisions 77% of the time. The agreement rate varied depending on treatment modality: 90% for transcatheter valve implantation, 65% for surgical valve replacement, and 65% for medical treatment. CONCLUSIONS: The use of LLMs offers promising opportunities to improve the HT decision-making process. This study showed that ChatGPT's decisions were consistent with those of the HT in a large proportion of cases. This technology could serve as a failsafe, highlighting potential areas of discrepancy when its decisions diverge from those of the HT. Further research is necessary to solidify our understanding of how AI can be integrated to enhance the decision-making processes of HTs.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Humanos , Inteligencia Artificial , Estudios Retrospectivos , Corazón , Estenosis de la Válvula Aórtica/cirugía
11.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
12.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506739

RESUMEN

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Microtomografía por Rayos X , Catéteres , Válvulas Cardíacas
13.
Am J Cardiol ; 219: 60-70, 2024 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
14.
J Clin Med ; 13(2)2024 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-38256589

RESUMEN

A growing body of evidence suggests that extrathoracic vascular accesses for transcatheter aortic valve replacement (TAVR) yield favorable outcomes and can be considered as primary alternatives when the gold-standard transfemoral access is contraindicated. Data comparing the transcaval (TCv) to supra-aortic (SAo) approaches (transcarotid, transsubclavian, and transaxillary) for TAVR are lacking. We aimed to compare the outcomes and safety of TCv and SAo accesses for TAVR as alternatives to transfemoral TAVR. A systematic review with meta-analysis was performed by searching PubMed/MEDLINE and EMBASE databases for all articles comparing TCv-TAVR against SAo-TAVR published until September 2023. Outcomes included in-hospital or 30-day all-cause mortality (ACM) and postoperative complications. A total of three studies with 318 TCv-TAVR and 179 SAo-TAVR patients were included. No statistically significant difference was found regarding in-hospital or 30-day ACM (relative risk [RR] 1.04, 95% confidence interval [CI] 0.47-2.34, p = 0.91), major bleeding, the need for blood transfusions, major vascular complications, and acute kidney injury. TCv-TAVR was associated with a non-statistically significant lower rate of neurovascular complications (RR 0.39, 95%CI 0.14-1.09, p = 0.07). These results suggest that both approaches may be considered as first-line alternatives to transfemoral TAVR, depending on local expertise and patients' anatomy. Additional data from long-term cohort studies are needed.

15.
Rev Med Suisse ; 20(856-7): 19-24, 2024 Jan 17.
Artículo en Francés | MEDLINE | ID: mdl-38231094

RESUMEN

The year 2023 has been extremely rich in new publications in the various subfields of cardiology. Furthermore, the European Society of Cardiology (ESC) has issued revised guidelines focused on the management of acute coronary syndrome (ACS) and endocarditis, as well as an update on the recommendations for the management of heart failure and cardiovascular prevention. The most significant updates according to the Cardiology Department of CHUV are summarized in this review article.


L'année 2023 a été extrêmement riche en nouvelles publications dans les différents sous-domaines de la cardiologie. De plus, la Société européenne de cardiologie (ESC) a formulé des directives révisées axées sur le management du syndrome coronarien aigu (SCA) et de l'endocardite ainsi qu'une mise à jour des recommandations sur la prise en charge de l'insuffisance cardiaque et la prévention cardiovasculaire. Les nouveautés les plus importantes selon l'équipe du Service de cardiologie du CHUV sont résumées dans cet article de synthèse.


Asunto(s)
Síndrome Coronario Agudo , Cardiología , Endocarditis , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia
17.
Eur J Cardiovasc Nurs ; 23(3): 296-304, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37610363

RESUMEN

AIMS: Early mobilization is associated with improved outcomes in hospitalized older patients. We sought to determine the effect of a nurse-led protocol on mobilization 4 h after transfemoral transcatheter aortic valve implantation (TAVI) across different units of care. METHODS AND RESULTS: We conducted a prospective observational cohort single-centre study of consecutive patients. We implemented a standardized protocol for safe early recovery and progressive mobilization in the critical care and cardiac telemetry units. We measured the time to first mobilization and conducted descriptive statistics to identify patient and system barriers to timely ambulation. We recruited 139 patients (82.5 years, SD = 6.7; 46% women). At baseline, patients who were mobilized early (≤4 h) and late (>4 h) did not differ, except for higher rates of diabetes (25.5% vs. 43.9%, P = 0.032) and peripheral arterial disease (8.2% vs. 26.8%, P = 0.003) in the late mobilization group. The median time to mobilization was 4 h [inter-quartile range (IQR) 3.25, 4]; 98 patients (70.5%) were mobilized successfully after 4 h of bedrest; 118 (84.9%) were walking by the evening of the procedure (<8 h bedrest); and 21 (15.1%) were on bedrest overnight and mobilized the following day. Primary reasons for overnight bedrest were arrhythmia monitoring (n = 10, 7.2%) and haemodynamic and/or neurological instability (n = 6, 4.3%); six patients (4.3%) experienced delayed ambulation due to system issues. Procedure location in the hybrid operating room and transfer to critical care were associated with longer bedrest times. CONCLUSION: Standardized nurse-led mobilization 4 h after TF TAVI is feasible in the absence of clinical complications and system barriers.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Ambulación Precoz , Resultado del Tratamiento , Factores de Tiempo , Estudios de Cohortes
18.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
19.
JACC Cardiovasc Imaging ; 17(2): 165-175, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37410009

RESUMEN

BACKGROUND: With growing adoption of coronary computed tomographic angiography (CTA), there is increasing evidence for and interest in the prognostic importance of atherosclerotic plaque volume. Manual tools for plaque segmentation are cumbersome, and their routine implementation in clinical practice is limited. OBJECTIVES: The aim of this study was to develop nomographic quantitative plaque values from a large consecutive multicenter cohort using coronary CTA. METHODS: Quantitative assessment of total atherosclerotic plaque and plaque subtype volumes was performed in patients undergoing clinically indicated coronary CTA, using an Artificial Intelligence-Enabled Quantitative Coronary Plaque Analysis tool. RESULTS: A total of 11,808 patients were included in the analysis; their mean age was 62.7 ± 12.2 years, and 5,423 (45.9%) were women. The median total plaque volume was 223 mm3 (IQR: 29-614 mm3) and was significantly higher in male participants (360 mm3; IQR: 78-805 mm3) compared with female participants (108 mm3; IQR: 10-388 mm3) (P < 0.0001). Total plaque increased with age in both male and female patients. Younger patients exhibited a higher prevalence of noncalcified plaque. The distribution of total plaque volume and its components was reported in every decile by age group and sex. CONCLUSIONS: The authors developed pragmatic age- and sex-stratified percentile nomograms for atherosclerotic plaque measures using findings from coronary CTA. The impact of age and sex on total plaque and its components should be considered in the risk-benefit analysis when treating patients. Artificial Intelligence-Enabled Quantitative Coronary Plaque Analysis work flows could provide context to better interpret coronary computed tomographic angiographic measures and could be integrated into clinical decision making.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Angiografía Coronaria/métodos , Inteligencia Artificial , Valor Predictivo de las Pruebas , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada por Rayos X
20.
Int J Cardiol ; 399: 131663, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38141730

RESUMEN

BACKGROUND: FFRangio and QFR are angiography-based technologies that have been validated in patients with stable coronary artery disease. No head-to-head comparison to invasive fractional flow reserve (FFR) has been reported to date in patients with acute coronary syndromes (ACS). METHODS: This study is a subset of a larger prospective multicenter, single-arm study that involved patients diagnosed with high-risk ACS in whom 30-70% stenosis was evaluated by FFR. FFRangio and QFR - both calculated offline by 2 different and blinded operators - were calculated and compared to FFR. The two co-primary endpoints were the comparison of the Pearson correlation coefficient between FFRangio and QFR with FFR and the comparison of their inter-observer variability. RESULTS: Among 134 high-risk ACS screened patients, 59 patients with 84 vessels underwent FFR measurements and were included in this study. The mean FFR value was 0.82 ± 0.40 with 32 (38%) being ≤0.80. The mean FFRangio was 0.82 ± 0.20 and the mean QFR was 0.82 ± 0.30, with 27 (32%) and 25 (29%) being ≤0.80, respectively. The Pearson correlation coefficient was significantly better for FFRangio compared to QFR, with R values of 0.76 and 0.61, respectively (p = 0.01). The inter-observer agreement was also significantly better for FFRangio compared to QFR (0.86 vs 0.79, p < 0.05). FFRangio had 91% sensitivity, 100% specificity, and 96.8% accuracy, while QFR exhibited 86.4% sensitivity, 98.4% specificity, and 93.7% accuracy. CONCLUSION: In patients with high-risk ACS, FFRangio and QFR demonstrated excellent diagnostic performance. FFRangio seems to have better correlation to invasive FFR compared to QFR but further larger validation studies are required.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Estudios Prospectivos , Estenosis Coronaria/diagnóstico por imagen , Angiografía Coronaria/métodos , Síndrome Coronario Agudo/diagnóstico por imagen , Valor Predictivo de las Pruebas , Vasos Coronarios , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA