Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Med Phys ; 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39134054

RESUMEN

BACKGROUND: Dynamic Computed Tomography Angiography (4D CTA) has the potential of providing insight into the biomechanical properties of the vessel wall, by capturing motion of the vessel wall. For vascular pathologies, like intracranial aneurysms, this could potentially refine diagnosis, prognosis, and treatment decision-making. PURPOSE: The objective of this research is to determine the feasibility of a 4D CTA scanner for accurately measuring harmonic diameter changes in an in-vitro simulated vessel. METHODS: A silicon tube was exposed to a simulated heartbeat. Simulated heart rates between 40 and 100 beats-per-minute (bpm) were tested and the flow amplitude was varied, resulting in various changes of tube diameter. A 320-detector row CT system with ECG-gating captured three consecutive cycles of expansion. Image registration was used to calculate the diameter change. A vascular echography set-up was used as a reference, using a 9 MHz linear array transducer. The reproducibility of 4D CTA was represented by the Pearson correlation (r) between the three consecutive diameter change patterns, captured by 4D CTA. The peak value similarity (pvs) was calculated between the 4D CTA and US measurements for increasing frequencies and was chosen as a measure of temporal resolution. Spatial resolution was represented by the Sum of the Relative Percentual Difference (SRPD) between 4D CTA and US diameter change patterns for increasing amplitudes. RESULTS: The reproducibility of 4D CTA measurements was good (r ≥ 0.9) if the diameter change was larger than 0.3 mm, moderate (0.7 ≤ r < 0.9) if the diameter change was between 0.1 and 0.3 mm, and low (r < 0.7) if the diameter change was smaller than 0.1 mm. Regarding the temporal resolution, the amplitude of 4D CTA was similar to the US measurements (pvs ≥ 90%) for the frequencies of 40 and 50 bpm. Frequencies between 60 and 80 bpm result in a moderate similarity (70% ≤ pvs < 90%). A low similarity (pvs < 70%) is observed for 90 and 100 bpm. Regarding the spatial resolution, diameter changes above 0.30 mm result in SRPDs consistently below 50%. CONCLUSION: In a phantom setting, 4D CTA can be used to reliably capture reproducible tube diameter changes exceeding 0.30 mm. Low pulsation frequencies (40 or 50 bpm) provide an accurate measurement of the maximum tube diameter change.

2.
Front Neurol ; 15: 1440294, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39175757

RESUMEN

Objectives: SARS-CoV-2 infection is associated with a decline in functional outcomes; many patients experience persistent symptoms, while the underlying pathophysiology remains unclear. This study investigated white matter (WM) integrity on brain MRI in hospitalized COVID-19 patients and its associations with clinical outcomes, including long COVID. Materials and methods: We included hospitalized COVID-19 patients and controls from CORONavirus and Ischemic Stroke (CORONIS), an observational cohort study, who underwent MRI-DWI imaging at baseline shortly after discharge (<3 months after positive PCR) and 3 months after baseline scanning. We assessed WM integrity using diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) and performed comparisons between groups and within patients. Clinical assessment was conducted at 3 and 12 months with functional outcomes such as modified Rankin Scale (mRS), Post-COVID-19 Functional Status scale (PCFS), Visual Analogue Scale (VAS), and long COVID, cognitive assessment was conducted by the Modified Telephone Interview for Cognitive Status (TICS-M), and the Hospital Anxiety and Depression Scale (HADS) was used to assess mood disorder. Associations between WM integrity and clinical outcomes were evaluated using logistic regression and linear regression. Results: A total of 49 patients (mean age 59.5 years) showed higher overall peak width of skeletonized mean diffusivity (PSMD) (p = 0.030) and lower neurite density index (NDI) in several WM regions compared with 25 controls at the baseline (p < 0.05; FWE-corrected) but did not remain statistically significant after adjusting for WM hyperintensities. Orientation dispersion index (ODI) increased after 3-month follow-up in several WM regions within patients (p < 0.05), which remained significant after correction for changes in WMH volume. Patients exhibited worse clinical outcomes compared with controls. Low NDI at baseline was associated with worse performance on the Post-COVID-19 Functional Status scale after 12 months (p = 0.018). Conclusion: After adjusting for WMH, hospitalized COVID-19 patients no longer exhibited lower WM integrity compared with controls. WM integrity was generally not associated with clinical assessments as measured shortly after discharge, suggesting that factors other than underlying WM integrity play a role in worse clinical outcomes or long COVID.

4.
Eur J Radiol ; 178: 111643, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39067267

RESUMEN

BACKGROUND AND PURPOSE: Radiological features on magnetic resonance imaging (MRI) were attributed to oligodendroglioma, although the diagnostic accuracy in a real-world clinical setting remains partially elusive. This study investigated the accuracy and robustness of tumor heterogeneity and tumor border delineation on T2-weighted MRI to distinguish oligodendroglioma from astrocytoma. MATERIALS AND METHODS: Eight readers from three different specialties (radiology, neurology, neurosurgery) with varying levels of experience blindly rated 79 T2-weighted MR images of patients with either oligodendroglioma or astrocytoma. After the first reading session, all readers were re-invited for a second reading session within three weeks. Diagnostic accuracy, including area under the receiver operator characteristics curve (AUC), and intra-observer variability and inter-observer variability were used as outcome measures. RESULTS: Pooled sensitivity and specificity to distinguish oligodendroglioma from astrocytoma for the use of tumor heterogeneity were 59.9 % respectively 74.5 %, and 85.7 % respectively 40.1 % for tumor border. A second reading session did not result in a significant change in sensitivity or specificity for tumor heterogeneity (P = 0.752 and P = 0.733, respectively) or tumor border (P = 0.309 and P = 0.271, respectively). An AUC of 0.825 was achieved with regard to predicting oligodendroglial origin of gliomas. Intra-observer agreement ranged from moderate to very good for tumor heterogeneity (kappa-value 0.43-0.87) and tumor border (0.40-0.84). A moderate inter-oberserver agreement was achieved for tumor heterogeneity and tumor border (kappa-value of 0.50 and 0.45, respectively). CONCLUSION: This study demonstrates that tumor heterogeneity and tumor borders on T2-weighted MRI could be used with moderate Finter-observer agreement to non-invasively distinguish oligodendroglioma from astrocytoma.


Asunto(s)
Astrocitoma , Neoplasias Encefálicas , Imagen por Resonancia Magnética , Oligodendroglioma , Sensibilidad y Especificidad , Humanos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Oligodendroglioma/diagnóstico por imagen , Oligodendroglioma/patología , Astrocitoma/diagnóstico por imagen , Astrocitoma/patología , Diagnóstico Diferencial , Imagen por Resonancia Magnética/métodos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Reproducibilidad de los Resultados , Variaciones Dependientes del Observador , Anciano
5.
Eur J Radiol ; 178: 111644, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39084028

RESUMEN

RATIONALE AND OBJECTIVES: Various methods exist to perform and post-process perfusion weighted MR imaging in the post-treatment imaging of glioma patients to differentiate tumor progression from tumor-related abnormalities. One of these post-processing methods produces 'fractional tumor burden' maps. This multi-reader study investigated the clinical feasibility of fractional tumor burden maps on real world data from radiological follow-up of high-grade astrocytoma patients. METHODS: Five readers with background in radiology and varying levels of experience were tasked with assessing 30 astrocytoma and glioblastoma patients during one reader session. First, they were provided with a dataset of conventional MRI sequences, including perfusion MRI with regional cerebral blood volume maps. Then the dataset was expanded with a corresponding fractional tumor burden maps. Diagnostic accuracy, duration of post-processing, duration of the assessment of the fractional tumor burden maps, the diagnostic confidence reported by the readers and their diagnoses were recorded. Final diagnosis was determined by clinical and radiological follow-up and/or histopathological data used as gold standard. RESULTS: A mean sensitivity of 83.3 % and mean specificity of 55.1 % was obtained without the use of fractional tumor burden maps, whereas their additional of fractional tumor burden maps resulted in a mean sensitivity and specificity of 79.5 % and 54.2 %, respectively. Diagnostic accuracies with and without fractional tumor burden maps were not significantly different (Z = 0.76, p = 0.450). The median time spent post-processing was 313 s, while the median duration of the assessment of the FTB maps was 19 s. Interestingly, reader confidence increased significantly after adding the fractional tumor burden-maps to the assessment (Z = 454, p < 0.01). CONCLUSIONS: While the use of fractional tumor burden maps does not carry additional value in the radiological follow-up of post-operative high-grade astrocytoma and glioblastoma patients, it does give readers more confidence in their diagnosis.


Asunto(s)
Neoplasias Encefálicas , Sensibilidad y Especificidad , Carga Tumoral , Humanos , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Angiografía por Resonancia Magnética/métodos , Astrocitoma/diagnóstico por imagen , Reproducibilidad de los Resultados , Interpretación de Imagen Asistida por Computador/métodos , Glioblastoma/diagnóstico por imagen
6.
Neuroradiology ; 66(9): 1565-1575, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38953988

RESUMEN

PURPOSE: To investigate the prevalence of cerebrovascular MRI markers in unselected patients hospitalized for COVID-19 (Coronavirus disease 2019), we compared these with healthy controls without previous SARS-CoV-2 infection or hospitalization and subsequently, investigated longitudinal (incidental) lesions in patients after three months. METHODS: CORONIS (CORONavirus and Ischemic Stroke) was an observational cohort study in adult hospitalized patients for COVID-19 and controls without COVID-19, conducted between April 2021 and September 2022. Brain MRI was performed shortly after discharge and after 3 months. Outcomes included recent ischemic (DWI-positive) lesions, previous infarction, microbleeds, white matter hyperintensities (WMH) and intracerebral hemorrhage and were analysed with logistic regression to adjust for confounders. RESULTS: 125 patients with COVID-19 and 47 controls underwent brain MRI a median of 41.5 days after symptom onset. DWI-positive lesions were found in one patient (1%) and in one (2%) control, both clinically silent. WMH were more prevalent in patients (78%) than in controls (62%) (adjusted OR: 2.95 [95% CI: 1.07-8.57]), other cerebrovascular MRI markers did not differ. Prevalence of markers in ICU vs. non-ICU patients was similar. After three months, five patients (5%) had new cerebrovascular lesions, including DWI-positive lesions (1 patient, 1.0%), cerebral infarction (2 patients, 2.0%) and microbleeds (3 patients, 3.1%). CONCLUSION: Overall, we found no higher prevalence of cerebrovascular markers in unselected hospitalized COVID-19 patients compared to controls. The few incident DWI-lesions were most likely to be explained by risk-factors of small vessel disease. In the general hospitalized COVID-19 population, COVID-19 shows limited impact on cerebrovascular MRI markers shortly after hospitalization.


Asunto(s)
COVID-19 , Imagen por Resonancia Magnética , Humanos , COVID-19/diagnóstico por imagen , COVID-19/epidemiología , Masculino , Femenino , Prevalencia , Anciano , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Hospitalización , Estudios de Seguimiento , SARS-CoV-2 , Trastornos Cerebrovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/epidemiología , Estudios de Cohortes , Estudios de Casos y Controles
7.
Neuroradiology ; 66(8): 1279-1289, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38714545

RESUMEN

INTRODUCTION: Dynamic susceptibility contrast (DSC) perfusion weighted (PW)-MRI can aid in differentiating treatment related abnormalities (TRA) from tumor progression (TP) in post-treatment glioma patients. Common methods, like the 'hot spot', or visual approach suffer from oversimplification and subjectivity. Using perfusion of the complete lesion potentially offers an objective and accurate alternative. This study aims to compare the diagnostic value and assess the subjectivity of these techniques. METHODS: 50 Glioma patients with enhancing lesions post-surgery and chemo-radiotherapy were retrospectively included. Outcome was determined by clinical/radiological follow-up or biopsy. Imaging analysis used the 'hot spot', volume of interest (VOI) and visual approach. Diagnostic accuracy was compared using receiving operator characteristics (ROC) curves for the VOI and 'hot spot' approach, visual assessment was analysed with contingency tables. Inter-operator agreement was determined with Cohens kappa and intra-class coefficient (ICC). RESULTS: 29 Patients suffered from TP, 21 had TRA. The visual assessment showed poor to substantial inter-operator agreement (κ = -0.72 - 0.68). Reliability of the 'hot spot' placement was excellent (ICC = 0.89), while reference placement was variable (ICC = 0.54). The area under the ROC (AUROC) of the mean- and maximum relative cerebral blood volume (rCBV) (VOI-analysis) were 0.82 and 0.72, while the rCBV-ratio ('hot spot' analysis) was 0.69. The VOI-analysis had a more balanced sensitivity and specificity compared to visual assessment. CONCLUSIONS: VOI analysis of DSC PW-MRI data holds greater diagnostic accuracy in single-moment differentiation of TP and TRA than 'hot spot' or visual analysis. This study underlines the subjectivity of visual placement and assessment.


Asunto(s)
Neoplasias Encefálicas , Glioma , Humanos , Masculino , Glioma/diagnóstico por imagen , Glioma/terapia , Femenino , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/terapia , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Anciano , Medios de Contraste , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Imagen de Perfusión/métodos , Progresión de la Enfermedad , Angiografía por Resonancia Magnética/métodos
8.
Eur Radiol ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724766
9.
Neurooncol Adv ; 6(1): vdad168, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38196738

RESUMEN

Background: Survival outcomes for glioblastoma (GBM) patients remain unfavorable, and tumor recurrence is often observed. Understanding the radiological growth patterns of GBM could aid in improving outcomes. This study aimed to examine the relationship between contrast-enhancing tumor growth direction and white matter, using an image registration and deformation strategy. Methods: In GBM patients 2 pretreatment scans (diagnostic and neuronavigation) were gathered retrospectively, and coregistered to a template and diffusion tensor imaging (DTI) atlas. The GBM lesions were segmented and coregistered to the same space. Growth vectors were derived and divided into vector populations parallel (Φ = 0-20°) and perpendicular (Φ = 70-90°) to white matter. To test for statistical significance between parallel and perpendicular groups, a paired samples Student's t-test was performed. O6-methylguanine-DNA methyltransferase (MGMT) methylation status and its correlation to growth rate were also tested using a one-way ANOVA test. Results: For 78 GBM patients (mean age 61 years ±â€…13 SD, 32 men), the included GBM lesions showed a predominant preference for perineural satellitosis (P < .001), with a mean percentile growth of 30.8% (95% CI: 29.6-32.0%) parallel (0°â€…< |Φ| < 20°) to white matter. Perpendicular tumor growth with respect to white matter microstructure (70°â€…< |Φ| < 90°) showed to be 22.7% (95% CI: 21.3-24.1%) of total tumor growth direction. Conclusions: The presented strategy showed that tumor growth direction in pretreatment GBM patients correlated with white matter architecture. Future studies with patient-specific DTI data are required to verify the accuracy of this method prospectively to identify its usefulness as a clinical metric in pre and posttreatment settings.

10.
Curr Neurovasc Res ; 20(4): 472-479, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38099530

RESUMEN

OBJECTIVES: Repeated remote ischemic postconditioning (rIPostC) may be an easily applicable treatment following ischemic stroke to improve quality of life (QoL) and clinical outcomes. rIPostC consists of repeated, brief periods of limb ischemia (through inflation of a blood pressure cuff), followed by reperfusion. This study investigated the 1-year follow-up of rIPostC on QoL and clinical events. METHODS: As part of a randomized controlled trial, adult patients with an ischemic stroke within 24 hours after onset of symptoms were randomized to repeated rIPostC or sham-conditioning. rIPostC was applied twice daily during hospitalization (maximum of 4 days). QoL and patientreported outcome measures (PROMs) were assessed at 12-week and 1-year follow-ups. Additionally, we explored the effect of repeated rIPostC on clinical events (recurrent cerebrovascular events, hospitalization, and mortality). RESULTS: The trial was preliminarily stopped due to limitations in recruitment after the inclusion of 88 patients (rIPostC: 40; sham-conditioning: 48) (70 years, 68% male). Questionnaires were returned by 69 (78%) and 63 (72%) participants after 12 weeks and 1 year, respectively. The median difference of the stroke-specific QoL between rIPostC and sham-conditioning was 0.05 (p =0.986) and -0.16 (p =0.654) after 12 weeks and 1-year, respectively. No significant effect of rIPostC on the different domains of PROMs was detected. We observed no between-group differences in recurrent cerebrovascular events, hospitalization, or all-cause mortality (Hazard Ratios p >0.05). CONCLUSION: In this exploratory analysis, we observed no significant difference between repeated rIPostC and usual care on QoL and clinical outcomes at 12 weeks and 1 year in patients with an ischemic stroke. CLINICAL TRIAL REGISTRATION NUMBER: NTR6880.


Asunto(s)
Poscondicionamiento Isquémico , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Adulto , Humanos , Masculino , Femenino , Accidente Cerebrovascular Isquémico/terapia , Calidad de Vida , Accidente Cerebrovascular/terapia
11.
PLoS One ; 18(12): e0293353, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38134125

RESUMEN

BACKGROUND: Reliably capturing sub-millimeter vessel wall motion over time, using dynamic Computed Tomography Angiography (4D CTA), might provide insight in biomechanical properties of these vessels. This may improve diagnosis, prognosis, and treatment decision making in vascular pathologies. PURPOSE: The aim of this study is to determine the most suitable image reconstruction method for 4D CTA to accurately assess harmonic diameter changes of vessels. METHODS: An elastic tube (inner diameter 6 mm, wall thickness 2 mm) was exposed to sinusoidal pressure waves with a frequency of 70 beats-per-minute. Five flow amplitudes were set, resulting in increasing sinusoidal diameter changes of the elastic tube, measured during three simulated pulsation cycles, using ECG-gated 4D CTA on a 320-detector row CT system. Tomographic images were reconstructed using one of the following three reconstruction methods: hybrid iterative (Hybrid-IR), model-based iterative (MBIR) and deep-learning based (DLR) reconstruction. The three reconstruction methods where based on 180 degrees (half reconstruction mode) and 360 degrees (full reconstruction mode) raw data. The diameter change, captured by 4D CTA, was computed based on image registration. As a reference metric for diameter change measurement, a 9 MHz linear ultrasound transducer was used. The sum of relative absolute differences (SRAD) between the ultrasound and 4D CTA measurements was calculated for each reconstruction method. The standard deviation was computed across the three pulsation cycles. RESULTS: MBIR and DLR resulted in a decreased SRAD and standard deviation compared to Hybrid-IR. Full reconstruction mode resulted in a decreased SRAD and standard deviations, compared to half reconstruction mode. CONCLUSIONS: 4D CTA can capture a diameter change pattern comparable to the pattern captured by US. DLR and MBIR algorithms show more accurate results than Hybrid-IR. Reconstruction with DLR is >3 times faster, compared to reconstruction with MBIR. Full reconstruction mode is more accurate than half reconstruction mode.


Asunto(s)
Angiografía por Tomografía Computarizada , Interpretación de Imagen Radiográfica Asistida por Computador , Angiografía por Tomografía Computarizada/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Angiografía/métodos , Algoritmos , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación
12.
Cancers (Basel) ; 15(20)2023 Oct 14.
Artículo en Inglés | MEDLINE | ID: mdl-37894355

RESUMEN

Distinguishing treatment-related abnormalities (TRA) from tumor progression (TP) in glioblastoma patients is a diagnostic imaging challenge due to the identical morphology of conventional MR imaging sequences. Diffusion-weighted imaging (DWI) and its derived images of the apparent diffusion coefficient (ADC) have been suggested as diagnostic tools for this problem. The aim of this study is to determine the diagnostic accuracy of different cut-off values of the ADC to differentiate between TP and TRA. In total, 76 post-treatment glioblastoma patients with new contrast-enhancing lesions were selected. Lesions were segmented using a T1-weighted, contrast-enhanced scan. The mean ADC values of the segmentations were compared between TRA and TP groups. Diagnostic accuracy was compared by use of the area under the curve (AUC) and the derived sensitivity and specificity values from cutoff points. Although ADC values in TP (mean = 1.32 × 10-3 mm2/s; SD = 0.31 × 10-3 mm2/s) were significantly different compared to TRA (mean = 1.53 × 10-3 mm2/s; SD = 0.28 × 10-3 mm2/s) (p = 0.003), considerable overlap in their distributions exists. The AUC of ADC values to distinguish TP from TRA was 0.71, with a sensitivity and specificity of 65% and 70%, respectively, at an ADC value of 1.47 × 10-3 mm2/s. These findings therefore indicate that ADC maps should not be used in discerning between TP and TRA at a certain timepoint without information on temporal evolution.

13.
Sci Rep ; 13(1): 12551, 2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37532773

RESUMEN

The Automation Platform (AP) is a software platform to support the workflow of radiologists and includes a stroke CT package with integrated artificial intelligence (AI) based tools. The aim of this study was to evaluate the diagnostic performance of the AP for the detection of intracranial large vessel occlusions (LVO) on conventional CT angiography (CTA), and the duration of CT processing in a cohort of acute stroke patients. The diagnostic performance for intracranial LVO detection on CTA by the AP was evaluated in a retrospective cohort of 100 acute stroke patients and compared to the diagnostic performance of five radiologists with different levels of experience. The reference standard was set by an independent neuroradiologist, with access to the readings of the different radiologists, clinical data, and follow-up. The data processing time of the AP for ICH detection on non-contrast CT, LVO detection on CTA, and the processing of CTP maps was assessed in a subset 60 patients of the retrospective cohort. This was compared to 13 radiologists, who were prospectively timed for the processing and reading of 21 stroke CTs. The AP showed shorter processing time of CTA (mean 60 versus 395 s) and CTP (mean 196 versus 243-349 s) as compared to radiologists, but showed lower sensitivity for LVO detection (sensitivity 77% of the AP vs mean sensitivity 87% of radiologists). If the AP would have been used as a stand-alone system, 1 ICA occlusion, 2 M1 occlusions and 8 M2 occlusions would have been missed, which would be eligible for mechanical thrombectomy. In conclusion, the AP showed shorter processing time of CTA and CTP as compared with radiologists, which illustrates the potential of the AP to speed-up the diagnostic work-up. However, its performance for LVO detection was lower as compared with radiologists, especially for M2 vessel occlusions.


Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Humanos , Inteligencia Artificial , Estudios Retrospectivos , Flujo de Trabajo , Angiografía Cerebral , Accidente Cerebrovascular/diagnóstico por imagen , Angiografía por Tomografía Computarizada
14.
Sci Rep ; 13(1): 11507, 2023 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-37460572

RESUMEN

In coronavirus disease 2019 (COVID-19), endothelial cells play a central role and an inadequate response is associated with vascular complications. PET imaging with gallium-68 labelled RGD-peptide (68Ga-RGD) targets αvß3 integrin expression which allows quantification of endothelial activation. In this single-center, prospective observational study, we included ten hospitalized patients with COVID-19 between October 2020 and January 2021. Patients underwent 68Ga-RGD PET/CT followed by iodine mapping of lung parenchyma. CT-based segmentation of lung parenchyma, carotid arteries and myocardium was used to quantify tracer uptake by calculating standardized uptake values (SUV). Five non-COVID-19 patients were used as reference. The study population was 68.5 (IQR 52.0-74.5) years old, with median oxygen need of 3 l/min (IQR 0.9-4.0). 68Ga-RGD uptake quantified as SUV ± SD was increased in lungs (0.99 ± 0.32 vs. 0.45 ± 0.18, p < 0.01) and myocardium (3.44 ± 1.59 vs. 0.65 ± 0.22, p < 0.01) of COVID-19 patients compared to reference but not in the carotid arteries. Iodine maps showed local variations in parenchymal perfusion but no correlation with SUV. In conclusion, using 68Ga-RGD PET/CT in COVID-19 patients admitted with respiratory symptoms, we demonstrated increased endothelial activation in the lung parenchyma and myocardium. Our findings indicate the involvement of increased and localized endothelial cell activation in the cardiopulmonary system in COVID-19 patients.Trail registration: NCT04596943.


Asunto(s)
COVID-19 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Persona de Mediana Edad , Anciano , Radioisótopos de Galio , Células Endoteliales/metabolismo , COVID-19/diagnóstico por imagen , Tomografía de Emisión de Positrones , Oligopéptidos , Integrina alfaVbeta3/metabolismo
15.
Cancers (Basel) ; 15(9)2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37174097

RESUMEN

The post-treatment imaging surveillance of gliomas is challenged by distinguishing tumor progression (TP) from treatment-related abnormalities (TRA). Sophisticated imaging techniques, such as perfusion-weighted magnetic resonance imaging (MRI PWI) and positron-emission tomography (PET) with a variety of radiotracers, have been suggested as being more reliable than standard imaging for distinguishing TP from TRA. However, it remains unclear if any technique holds diagnostic superiority. This meta-analysis provides a head-to-head comparison of the diagnostic accuracy of the aforementioned imaging techniques. Systematic literature searches on the use of PWI and PET imaging techniques were carried out in PubMed, Embase, the Cochrane Library, ClinicalTrials.gov and the reference lists of relevant papers. After the extraction of data on imaging technique specifications and diagnostic accuracy, a meta-analysis was carried out. The quality of the included papers was assessed using the QUADAS-2 checklist. Nineteen articles, totaling 697 treated patients with glioma (431 males; mean age ± standard deviation 50.5 ± 5.1 years) were included. The investigated PWI techniques included dynamic susceptibility contrast (DSC), dynamic contrast enhancement (DCE) and arterial spin labeling (ASL). The PET-tracers studied concerned [S-methyl-11C]methionine, 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG), O-(2-[18F]fluoroethyl)-L-tyrosine ([18F]FET) and 6-[18F]-fluoro-3,4-dihydroxy-L-phenylalanine ([18F]FDOPA). The meta-analysis of all data showed no diagnostic superior imaging technique. The included literature showed a low risk of bias. As no technique was found to be diagnostically superior, the local level of expertise is hypothesized to be the most important factor for diagnostically accurate results in post-treatment glioma patients regarding the distinction of TRA from TP.

17.
Eur Radiol ; 33(3): 2139-2148, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36418623

RESUMEN

OBJECTIVES: Approximately 50% of comatose patients after cardiac arrest never regain consciousness. Cerebral ischaemia may lead to cytotoxic and/or vasogenic oedema, which can be detected by diffusion tensor imaging (DTI). Here, we evaluate the potential value of free water corrected mean diffusivity (MD) and fractional anisotropy (FA) based on DTI, for the prediction of neurological recovery of comatose patients after cardiac arrest. METHODS: A total of 50 patients after cardiac arrest were included in this prospective cohort study in two Dutch hospitals. DTI was obtained 2-4 days after cardiac arrest. Outcome was assessed at 6 months, dichotomised as poor (cerebral performance category 3-5; n = 20) or good (n = 30) neurological outcome. We calculated the whole brain mean MD and FA and compared between patients with good and poor outcomes. In addition, we compared a preliminary prediction model based on clinical parameters with or without the addition of MD and FA. RESULTS: We found significant differences between patients with good and poor outcome of mean MD (good: 726 [702-740] × 10-6 mm2/s vs. poor: 663 [575-736] × 10-6 mm2/s; p = 0.01) and mean FA (0.30 ± 0.03 vs. 0.28 ± 0.03; p = 0.03). An exploratory prediction model combining clinical parameters, MD and FA increased the sensitivity for reliable prediction of poor outcome from 60 to 85%, compared to the model containing clinical parameters only, but confidence intervals are overlapping. CONCLUSIONS: Free water-corrected MD and FA discriminate between patients with good and poor outcomes after cardiac arrest and hold the potential to add to multimodal outcome prediction. KEY POINTS: • Whole brain mean MD and FA differ between patients with good and poor outcome after cardiac arrest. • Free water-corrected MD can better discriminate between patients with good and poor outcome than uncorrected MD. • A combination of free water-corrected MD (sensitive to grey matter abnormalities) and FA (sensitive to white matter abnormalities) holds potential to add to the prediction of outcome.


Asunto(s)
Imagen de Difusión Tensora , Paro Cardíaco , Humanos , Imagen de Difusión Tensora/métodos , Coma/etiología , Estudios Prospectivos , Encéfalo , Paro Cardíaco/complicaciones , Agua , Anisotropía
18.
J Neurointerv Surg ; 15(4): 355-362, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35318957

RESUMEN

BACKGROUND: A thrombus in the M1 segment of the middle cerebral artery (MCA) can occlude this main stem only or extend into the M1-M2 bifurcation. The occlusion pattern may affect endovascular treatment (EVT) success, as a bifurcated thrombus may be more prone to fragmentation during retrieval. OBJECTIVE: To investigate whether bifurcated thrombus patterns are associated with EVT procedural and clinical outcomes. METHODS: Occlusion patterns of MCA thrombi on CT angiography from MR CLEAN Registry patients were classified into three groups: main stem occlusion, bifurcation occlusion extending into one M2 branch, and bifurcation occlusion extending into both M2 branches. Procedural parameters, procedural outcomes (reperfusion grade and embolization to new territory), and clinical outcomes (24-48 hour National Institutes of Health Stroke Scale [NIHSSFU] score, change in NIHSS scores between 24 and 48 hours and baseline ∆ [NIHSS], and 90-day modified Rankin Scale [mRS] scores) were compared between occlusion patterns. RESULTS: We identified 1023 patients with an MCA occlusion of whom 370 (36%) had a main stem occlusion, 151 (15%) a single branch, and 502 (49%) a double branch bifurcation occlusion. There were no statistically significant differences in retrieval method, procedure time, number of retrieval attempts, reperfusion grade, and embolization to new territory between occlusion patterns. Patients with main stem occlusions had lower NIHSSFU scores than patients with single (7 vs 11, p=0.01) or double branch occlusions (7 vs 9, p=0.04). However, there were no statistically significant differences in ∆ NIHSS or in 90-day mRS scores. CONCLUSIONS: In our population, EVT procedural and long-term clinical outcomes were similar for MCA bifurcation occlusions and MCA main stem occlusions.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Estados Unidos , Humanos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Accidente Cerebrovascular Isquémico/complicaciones , Resultado del Tratamiento , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/cirugía , Arteria Cerebral Media
19.
Diagnostics (Basel) ; 12(12)2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36553021

RESUMEN

Good collateral status in acute ischemic stroke patients is an important indicator for good outcomes. Perfusion imaging potentially allows for the simultaneous assessment of local perfusion and collateral status. We combined multiple CTP parameters to evaluate a CTP-based collateral score. We included 85 patients with a baseline CTP and single-phase CTA images from the MR CLEAN Registry. We evaluated patients' CTP parameters, including relative CBVs and tissue volumes with several time-to-maximum ranges, to be candidates for a CTP-based collateral score. The score candidate with the strongest association with CTA-based collateral score and a 90-day mRS was included for further analyses. We assessed the association of the CTP-based collateral score with the functional outcome (mRS 0-2) by analyzing three regression models: baseline prognostic factors (model 1), model 1 including the CTA-based collateral score (model 2), and model 1 including the CTP-based collateral score (model 3). The model performance was evaluated using C-statistic. Among the CTP-based collateral score candidates, relative CBVs with a time-to-maximum of 6-10 s showed a significant association with CTA-based collateral scores (p = 0.02) and mRS (p = 0.05) and was therefore selected for further analysis. Model 3 most accurately predicted favorable outcomes (C-statistic = 0.86, 95% CI: 0.77-0.94) although differences between regression models were not statistically significant. We introduced a CTP-based collateral score, which is significantly associated with functional outcome and may serve as an alternative collateral measure in settings where MR imaging is not feasible.

20.
Insights Imaging ; 13(1): 158, 2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36194373

RESUMEN

BACKGROUND: In a considerable subgroup of glioma patients treated with (chemo) radiation new lesions develop either representing tumor progression (TP) or treatment-related abnormalities (TRA). Quantitative diffusion imaging metrics such as the Apparent Diffusion Coefficient (ADC) and Fractional Anisotropy (FA) have been reported as potential metrics to noninvasively differentiate between these two phenomena. Variability in performance scores of these metrics and absence of a critical overview of the literature contribute to the lack of clinical implementation. This meta-analysis therefore critically reviewed the literature and meta-analyzed the performance scores. METHODS: Systematic searching was carried out in PubMed, EMBASE and The Cochrane Library. Using predefined criteria, papers were reviewed. Diagnostic accuracy values of suitable papers were meta-analyzed quantitatively. RESULTS: Of 1252 identified papers, 10 ADC papers, totaling 414 patients, and 4 FA papers, with 154 patients were eligible for meta-analysis. Mean ADC values of the patients in the TP/TRA groups were 1.13 × 10-3mm2/s (95% CI 0.912 × 10-3-1.32 × 10-3mm2/s) and 1.38 × 10-3mm2/s (95% CI 1.33 × 10-3-1.45 × 10-3mm2/s, respectively. Mean FA values of TP/TRA was 0.19 (95% CI 0.189-0.194) and 0.14 (95% CI 0.137-0.143) respectively. A significant mean difference between ADC and FA values in TP versus TRA was observed (p = 0.005). CONCLUSIONS: Quantitative ADC and FA values could be useful for distinguishing TP from TRA on a meta-level. Further studies using serial imaging of individual patients are warranted to determine the role of diffusion imaging in glioma patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA