Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Int J Mol Sci ; 25(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38791097

RESUMEN

The field of dental materials is rapidly evolving, and this Special Issue of the International Journal of Molecular Sciences offers a comprehensive examination of the latest advancements in process design and development strategies [...].


Asunto(s)
Materiales Dentales , Materiales Dentales/uso terapéutico , Humanos
2.
J Dent Educ ; 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38532660

RESUMEN

The dilemma surrounding faculty shortages within dental education continues to present significant challenges for the dental profession. There remains a tremendous need to create an effective and sustainable pathway for the recruitment of faculty into dental academia, with an emphasis on the establishment of a more diverse and representative faculty composition. This perspective paper proposes a blueprint to nurture and inspire dental students into academia.

3.
J Endod ; 50(6): 844-851, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38369102

RESUMEN

INTRODUCTION: This study evaluates the feasibility of an augmented reality (AR) head-mounted device (HMD) displaying a dynamic navigation system (DNS) in the surgical site for fiber postremoval in maxillary molars and compares it to the DNS technique. METHODS: Fifty maxillary first molars were divided into 2 groups: AR HMD + DNS (n = 25) and DNS (n = 25). The palatal canal was restored with RelyX fiber post (3M ESPE) luted with RelyX Unicem (3M ESPE). A core buildup was performed using Paracore (Coltene/Whaledent). Cone beam computed tomography (CBCT) scans were taken before and after postremoval. The drilling trajectory and depth were planned under X-guide software (X-Nav Technologies, Lansdale, PA). For the AR HMD + DNS group, the AR HMD (Microsoft HoloLens 2) displayed the DNS in the surgical site. The three dimensional (3D) deviations (Global coronal deviation [GCD] and global apical deviation [GAD]) and angular deflection (AD) were calculated. The number of mishaps and operating time were recorded. RESULTS: Fiber post was removed from all samples (50/50). The AR HMD + DNS was more accurate than DNS, showing significantly lower GCD and GAD deviations and AD (P < .05). No mishap was detected. The AR HMD + DNS was as efficient in time as DNS (P > .05). CONCLUSIONS: Within the limitations of this in vitro study, the AR HMD can safely display DNS in the surgical site for fiber post-removal in maxillary molars. AR HMD improved the DNS accuracy. Both AR HMD + DNS and DNS were time-efficient for fiber postremoval in maxillary molars.


Asunto(s)
Realidad Aumentada , Tomografía Computarizada de Haz Cónico , Maxilar , Diente Molar , Humanos , Maxilar/cirugía , Cirugía Asistida por Computador/métodos , Estudios de Factibilidad
4.
ACS Appl Mater Interfaces ; 16(2): 2120-2139, 2024 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-38170561

RESUMEN

The process of bonding to dentin is complex and dynamic, greatly impacting the longevity of dental restorations. The tooth/dental material interface is degraded by bacterial acids, matrix metalloproteinases (MMPs), and hydrolysis. As a result, bonded dental restorations face reduced longevity due to adhesive interfacial breakdown, leading to leakage, tooth pain, recurrent caries, and costly restoration replacements. To address this issue, we synthesized and characterized a multifunctional magnetic platform, CHX@SiQuac@Fe3O4@m-SiO2, to provide several beneficial functions. The platform comprises Fe3O4 microparticles and chlorhexidine (CHX) encapsulated within mesoporous silica, which was silanized by an antibacterial quaternary ammonium silane (SiQuac). This platform simultaneously targets bacterial inhibition, stability of the hybrid layer, and enhanced filler infiltration by magnetic motion. Comprehensive experiments include X-ray diffraction, FT-IR, VSM, EDS, N2 adsorption-desorption (BET), transmission electron microscopy, scanning electron microscopy, thermogravimetric analysis, and UV-vis spectroscopy. Then, CHX@SiQuac@Fe3O4@m-SiO2 was incorporated into an experimental adhesive resin for dental bonding restorations, followed by immediate and long-term antibacterial assessment, cytotoxicity evaluation, and mechanical and bonding performance. The results confirmed the multifunctional nature of CHX@SiQuac@Fe3O4@m-SiO2. This work outlined a roadmap for (1) designing and tuning an adhesive formulation containing the new platform CHX@SiQuac@Fe3O4@m-SiO2; (2) assessing microtensile bond strength to dentin using a clinically relevant model of simulated hydrostatic pulpal pressure; and (3) investigating the antibacterial outcome performance of the particles when embedded into the formulated adhesives over time. The results showed that at 4 wt % of CHX@SiQuac@Fe3O4@m-SiO2-doped adhesive under the guided magnetic field, the bond strength increased by 28%. CHX@SiQuac@Fe3O4@m-SiO2 enhanced dentin adhesion in the magnetic guide bonding process without altering adhesive properties or causing cytotoxicity. This finding presents a promising method for strengthening the tooth/dental material interface's stability and extending the bonded restorations' lifespan.


Asunto(s)
Silanos , Dióxido de Silicio , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Clorhexidina/química , Antibacterianos/farmacología , Cementos Dentales/farmacología , Materiales Dentales , Fenómenos Magnéticos , Dentina , Ensayo de Materiales , Resistencia a la Tracción
5.
J Contemp Dent Pract ; 24(1): 4-8, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37189005

RESUMEN

AIM: This study aimed to compare the best restorative approach for the conservative class I cavity by comparing flowable and nanohybrid composites versus the placement technique regarding surface microhardness, porosity, and presence of interface gaps. MATERIALS AND METHODS: Forty human molars were divided into four groups (n = 10). Standardized class I cavities were prepared and restored using one of the following materials: Group I - Flowable composite placed by incremental technique; group II - Flowable composite placed in one increment; group III - Nanohybrid composite placed by incremental technique; and group IV - Nano-hybrid composite placed in one increment. After finishing and polishing, specimens were sectioned into two halves. One section was chosen randomly for the Vickers microhardness (HV) evaluation and the other section was used for the assessment of porosities and interfacial adaptation (IA). RESULTS: The surface microhardness range was 28.5-76.2 (p < 0.05), mean pulpal microhardness range was 27.6-74.4 (p < 0.05). Flowable composites had lower HV than conventional counterparts. The mean pulpal HV of all materials exceeded 80% of occlusal HV. Restorative approaches did not statistically differ in porosities. However, IA percentages were higher in flowable materials compared to nanocomposites. CONCLUSION: Flowable resin composite materials have lower microhardness than Nanohybrid composites. In small class I cavities, the number of porosities was similar between the different placement techniques and the interfacial gaps were highest in the flowable composites. CLINICAL SIGNIFICANCE: The use of nanohybrid resin composite to restore class I cavities will result in better hardness and less interfacial gaps compared to flowable composites.


Asunto(s)
Caries Dental , Restauración Dental Permanente , Humanos , Resinas Compuestas , Materiales Dentales , Restauración Dental Permanente/métodos , Dureza , Ensayo de Materiales , Porosidad
6.
J World Fed Orthod ; 12(3): 93-104, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37198009

RESUMEN

BACKGROUND: This study investigates characteristics of temporary anchorage devices (TADs) use by surveying a sample of international orthodontists. Furthermore, the survey investigates the stability, insertion technique, and failure rate of TADs and professionals' experience in residency, and it also attempts to establish guidelines for its use in everyday practice. METHODS: A 19-question survey was sent to orthodontists worldwide asking opinion-based, case-specific, and placement technique questions regarding TADs. Results were collected from 251 survey respondents. The country/regions of practice and length of time practicing orthodontics were the independent variables. RESULTS: Survey respondents indicated that most orthodontists rarely or sporadically use TADs. Significant differences were also found for TAD utilization purposes, sizes, and placement techniques among different countries/regions and for failure rates (1 or more of the last 6 TADs placed failed-61.6%). A significant difference was found in how many TADs orthodontists placed in residency versus private practice (56% vs. 15%) in relation to how long they have been practicing, but it did not greatly affect the frequency of use, mechanics, or placement technique. CONCLUSIONS: The frequency of TAD use is similar in many different countries and among different age groups. Although the collected responses suggested significant differences among respondents from different countries, the variability of results for TAD use worldwide prevent the establishment of clear guidelines.


Asunto(s)
Métodos de Anclaje en Ortodoncia , Ortodoncia , Humanos , Ortodoncistas , Encuestas y Cuestionarios , Práctica Privada
7.
Biomedicines ; 11(5)2023 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-37238927

RESUMEN

Damage in the bonding interface is a significant factor that leads to premature failure of dental bonded restorations. The imperfectly bonded dentin-adhesive interface is susceptible to hydrolytic degradation and bacterial and enzyme attack, severely jeopardizing restorations' longevity. Developing caries around previously made restorations, also called "recurrent or secondary caries," is a significant health problem. The replacement of restorations is the most prevailing treatment in dental clinics, leading to the so-called "tooth death spiral". In other words, every time a restoration is replaced, more tooth tissue is removed, increasing the size of the restorations until the tooth is eventually lost. This process leads to high financial costs and detriment to patients' quality of life. Since the complexity of the oral cavity makes prevention a challenging task, novel strategies in Dental Materials and Operative fields are required. This article briefly overviews the physiological dentin substrate, features of dentin bonding, challenges and clinical relevance. We discussed the anatomy of the dental bonding interface, aspects of the degradation at the resin-dentin interface, extrinsic and intrinsic factors affecting dental bonding longevity, perspectives on resin and collagen degradation and how these subjects are connected. In this narrative review, we also outlined the recent progress in overcoming dental bonding challenges through bioinspiration, nanotechnology and advanced techniques to reduce degradation and improve dental bonding longevity.

8.
Planta Med ; 89(11): 1034-1044, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37230482

RESUMEN

Dental erosion is a chemical process characterized by acid dissolution of dental hard tissue, and its etiology is multifactorial. Dietary polyphenols can be a strategy for dental erosion management, collaborating to preserve dental tissues through resistance to biodegradation. This study describes a comprehensive review to interpret the effects of polyphenols on dental erosion of pre-clinical models with in situ designs and simulated acid attacks on enamel and dentin samples. We aim to evaluate evidence about Polyphenols' effects in the type of dental substrate, parameters of erosive cycling chosen in the in situ models, and the possible mechanisms involved. An evidence-based literature review was conducted using appropriate search strategies developed for main electronic databases (PubMed, Scopus, Web of Science, LILACS, EMBASE, LIVIVO, CINAHL, and DOSS) and gray literature (Google Scholar). The Joanna Briggs Institute checklist was used to evaluate the quality of the evidence. From a total of 1900 articles, 8 were selected for evidence synthesis, including 224 specimens treated with polyphenols and 224 control samples. Considering the studies included in this review, we could observe that polyphenols tend to promote a reduction in erosive and abrasive wear compared to control groups. However, as the few studies included have a high risk of bias with different methodologies and the estimated effect size is low, this conclusion should not be extrapolated to clinical reality.


Asunto(s)
Abrasión de los Dientes , Erosión de los Dientes , Erosión de los Dientes/prevención & control , Erosión de los Dientes/complicaciones , Abrasión de los Dientes/etiología
9.
Clin Oral Investig ; 27(6): 2465-2481, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37017759

RESUMEN

OBJECTIVES: The aim of this review to overview three-dimensional (3D) printing technologies available for different dental disciplines, considering the applicability of such technologies and materials development. MATERIALS AND METHODS: Source Arksey and O'Malley's five stages framework using PubMed, EMBASE, and Scopus (Elsevier) databases managed this review. Papers focusing on 3D printing in dentistry and written in English were screened. Scientific productivity by the number of publications, areas of interest, and the focus of the investigations in each dental discipline were extracted. RESULTS: Nine hundred thirty-four studies using 3D printing in dentistry were assessed. Limited clinical trials were observed, especially in Restorative, endodontics, and pediatric dentistry. Laboratory or animal studies are not reliable for clinical success, suggesting that clinical trials are a good approach to validate the new methods' outcomes and ensure that the benefits outweigh the risk. The most common application for 3D printing technologies is to facilitate conventional dental procedures. CONCLUSIONS: The constantly improving quality of 3D printing applications has contributed to increasing the popularity of these technologies in dentistry; however, long-term clinical studies are necessary to assist in defining standards and endorsing the safe application of 3D printing in dental practice. CLINICAL RELEVANCE: The recent progress in 3D materials has improved dental practice capabilities over the last decade. Understanding the current status of 3D printing in dentistry is essential to facilitate translating its applications from laboratory to the clinical setting.


Asunto(s)
Endodoncia , Impresión Tridimensional , Humanos , Odontología Pediátrica , Atención Odontológica
10.
Clin Oral Investig ; 27(4): 1781-1792, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36462038

RESUMEN

OBJECTIVE: To compare 2 different resin composites and 2 adhesive systems used in a new restorative protocol (partial restoration) to treat non-carious cervical lesions associated with gingival recession type 1 (RT1). MATERIAL AND METHODS: Eighty combined defects (CDs) were treated with a partial restoration and periodontal plastic surgery for root coverage. The CDs were randomly assigned to one of the following groups: NP + TE (n = 20), nanofilled composite and 2-step total-etch adhesive system; NP + UA (n = 20), nanofilled composite and universal adhesive system; MH + TE (n = 20), microhybrid composite and 2-step total-etch adhesive; MH + UA (n = 20), microhybrid composite and universal adhesive. Restorations were assessed using the United States Public Health Service (USPHS) criteria at 1 week (baseline) and 6, 12, and 24 months. Survival rate, periodontal parameters, dentin hypersensitivity (DH), and aesthetics were also evaluated. RESULTS: After 24 months, only the MH + TE group did not lose any restoration, with no significant differences between groups. For surface roughness parameter, MH presented 83.3% of the restorations scoring Bravo, whereas NP presented 48.5% of the restorations scoring Bravo. All groups presented restorations with marginal discoloration. All periodontal parameters behaved similarly, regardless of the restorative material. All groups presented significant reductions of dentin hypersensitivity and improved aesthetic perceptions (p < 0.05). CONCLUSION: Both resin composites and adhesives tested can be combined for partial restorations to treat CDs. CLINICAL RELEVANCE: This new restorative-surgical protocol to treat CDs presents satisfactory outcomes. The partial restorations can be successfully executed with both combinations of adhesives and resin composites evaluated in this investigation. TRN : ClinicalTrial.gov: NCT03215615; registration date July 12, 2017.


Asunto(s)
Sensibilidad de la Dentina , Recesión Gingival , Humanos , Resinas Compuestas , Cementos Dentales , Adaptación Marginal Dental , Restauración Dental Permanente/métodos , Sensibilidad de la Dentina/terapia , Estética Dental , Estudios de Seguimiento , Recesión Gingival/cirugía , Cementos de Resina , Cuello del Diente/patología , Protocolos Clínicos
11.
J Dent ; 127: 104350, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36341980

RESUMEN

OBJECTIVES: To develop a risk of bias tool for pre-clinical dental materials research studies that aims to support reporting of future investigations and improve assessment in systematic reviews. METHODS: A four-stage process following EQUATOR network recommendations was followed, which included project launch, literature review, Delphi process and the tool finalization. With the support of the European Federation of Conservative Dentistry (EFCD) and the Dental Materials Group of the International Association for Dental Research (DMG-IADR), a total of 26 expert stakeholders were included in the development and Delphi vote of the initial proposal. The proposal was built using data gathered from the literature review stage. During this stage, recent systematic reviews featuring dental materials research, and risk of bias tools found in the literature were comprehensively scanned for bias sources. The experts thus reached a consensus for the items, domains and judgement related to the tool, allowing a detailed guide for each item and corresponding signalling questions. RESULTS: The tool features nine items in total, spread between 4 domains, pertaining to the following types of bias: bias related to planning and allocation (D1), specimen preparation (D2), outcome assessment (D3) and data treatment and outcome reporting (D4). RoBDEMAT, as presented, features signalling questions and a guide that can be used for RoB judgement. Its use as a checklist is preferred over a final summary score. CONCLUSION: RoBDEMAT is the first risk of bias tool for pre-clinical dental materials research, supported and developed by a broad group of expert stakeholders in the field, validating its future use. CLINICAL SIGNIFICANCE: This new tool will contribute the study field by improving the scientific quality and rigour of dental materials research studies and their systematic reviews. Such studies are the foundation and support of future clinical research and evidence-based decisions.


Asunto(s)
Lista de Verificación , Publicaciones , Revisiones Sistemáticas como Asunto , Sesgo , Materiales Dentales
12.
Bioengineering (Basel) ; 9(10)2022 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-36290538

RESUMEN

There is a critical need for an accurate device for orthodontists to know the magnitude of forces exerted on the tooth by the orthodontic brackets. Here, we propose a new orthodontic force measurement principle to detect the deformation of the elastic semi-sphere sensor. Specifically, we aimed to detail technical issues and the feasibility of the sensor performance attached to the inner surface of the orthodontic aligner or on the tooth surface. Accurate force tracking is important for the optimal decision of aligner replacement and cost reduction. A finite element (FE) model of the semi-sphere sensor was developed, and the relationship between the force and the contact area change was investigated. The prototype was manufactured, and the force detection performance was experimentally verified. In the experiment, the semi-sphere sensor was manufactured using thermoplastic polymer, and a high-precision mold sized 3 mm in diameter. The change in the contact area in the semi-sphere sensor was captured using a portable microscope. Further development is justified, and future implementation of the proposed sensor would be an array of multiple semi-sphere sensors in different locations for directional orthodontic force detection.

13.
J Funct Biomater ; 13(4)2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36278659

RESUMEN

Current dental adhesives lack antibacterial properties. This study aimed to explore the effect of incorporating benzyldimethyldodecyl ammonium chloride (BDMDAC) on the degree of conversion, contact angle, ultimate tensile strength (UTS), microtensile bond strength (µTBS), cytotoxicity, antibacterial and bonding performance after artificial aging. A dental adhesive was doped with BDMDAC in the concentration range of 1-5 wt.%. For antibacterial assays, the BDMDAC compound was subject to planktonic cells of Streptococcus mutans. Then, after incorporation into the dental adhesive, an S. mutans biofilm model was used to grow 48 h-mature biofilms. The biofilms grown over the formulated materials were assessed by colony-forming unit (CFU) counting assay and fluorescence microscopy staining. In addition, the cytotoxicity was evaluated. Samples were subjected to 10,000 thermal cycles for aging and evaluated by UTS, µTBS, and CFU. Incorporating BDMDAC did not increase the cytotoxicity or change the physical properties when the mass fraction of the BDMDAC was 1-5 wt.%. The UTS of BDMDAC-doped adhesives was not impaired immediately or over time. A significant bacterial reduction was obtained for the mass fraction of the BDMDAC greater than 3 wt.%. However, the BDMDAC-doped adhesives did not offer an antibacterial effect after artificial aging. The overall results indicate that the BDMDAC strategy has the potential to control of microbial growth of cariogenic planktonic cells and biofilms. However, other new technological approaches are needed to overcome the deleterious effect of BDMDAC release over time such as those based on the principle of drug delivery systems whereby the BDMDAC is transported on microparticles or core shells, providing tangible benefits to oral health over time.

14.
Compend Contin Educ Dent ; 43(9): 612-615, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36227134

RESUMEN

With society trending toward the avoidance of artificial components, so-called "natural" products have been gaining space and people's attention in recent years. Activated charcoal-based dental products are a prominent example of this movement because of their promise of removal of extrinsic stains or whitening of teeth by a natural means. Such products have gained popularity among patients, and companies have explored this market, launching charcoal-based and activated charcoal-based dentifrices, mouthrinses, toothbrushes, and whitening products that can be easily found at nearby stores and on the internet.1.


Asunto(s)
Dentífricos , Blanqueamiento de Dientes , Decoloración de Dientes , Carbón Orgánico/uso terapéutico , Humanos , Cepillado Dental/efectos adversos
15.
Dent Clin North Am ; 66(4): 551-566, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36216446

RESUMEN

Bioactive materials for dental resin restorations are a rising field of investigation exploring treatment strategies for reducing the recurrence of carious lesions. The current effort has been directed toward developing dental materials that can inhibit biofilms and prevent tooth mineral loss. Bioactive resin materials have shown the potential to interfere with polymicrobial consortia in vivo and help maintain the lifespan of restorations.


Asunto(s)
Resinas Compuestas , Caries Dental , Biopelículas , Resinas Compuestas/uso terapéutico , Caries Dental/prevención & control , Materiales Dentales/uso terapéutico , Restauración Dental Permanente , Humanos
16.
J Dent ; 126: 104312, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36184005

RESUMEN

OBJECTIVE: In most clinical circumstances, secondary caries at the margin of fixed dental restorations leads to restoration failure and replacement. Accordingly, the objectives of this study were to: (1) develop a novel rechargeable nano-calcium phosphate (NACP) and nano-calcium fluoride (nCaF2) resin-based cement; and (2) investigate their mechanical properties and calcium (Ca), phosphate (P), and fluoride (F) ion release, recharge, and re-release for the first time. METHODS: The cement matrix consisted of pyromellitic glycerol dimethacrylate (PMGDM), ethoxylated bisphenol-A-dimethacrylate (EBPADMA) was denoted PEHB. Four cements were fabricated: (1) PEHB+0%NACP+0%nCaF2 (experimental control); (2) PEHB+25%NACP+0%nCaF2, (3) PEHB+0%NACP+25%nCaF2; (4) PEHB+12.5%NACP+12.5% nCaF2. RelyX luting cement was used as a commercial control. Mechanical properties and long-term Ca, P, and F ion release, recharge, and re-release were evaluated. RESULTS: Adding 25% NACP, 25% nCaF2 and adding both 12.5% NACP and 12.5% nCaF2 to the cement matrix presented a significantly higher shear bond strength, flexural strength compared to the commercial control (p < 0.05) with a comparable outcome with no significant different (p > 0.05) compared to experimental control. The film thickness results of all cement groups met the ISO requirement (<50 µm). The resin cement group with both 12.5% NACP and 12.5% nCaF2 successfully released Ca, P, and F ions at 3.1 ± 0.01, 1.1 ± 0.05, and 0.51±0.01 mmol/L respectively. Moreover, it showed the ability to re-release Ca, P, and F ions at 0.62±0.01, 0.12±0.01, and 0.42±0.01 mmol/L respectively. CONCLUSIONS: The resin cement group with both 12.5% NACP and 12.5% nCaF2 demonstrated the advantages of both types of bio-interactive fillers as it could release a higher level of ions than the resin cement with 25%nCAF2 and exhibited a better rechargeability compared to the resin cement with 25%NACP. CLINICAL SIGNIFICANCE: The ability of this novel resin-based cement to release, recharge, and re-release Ca, P, and F ions could be one of the keys to lengthening the survivability of fixed dental restorations. These features could help to reduce the onset of secondary caries by enhancing the remineralization and preventing the demineralization of tooth structures.


Asunto(s)
Caries Dental , Cementos de Resina , Humanos , Fluoruros , Fluoruro de Calcio , Glicerol , Fosfatos de Calcio/química , Metacrilatos/química , Cementos Dentales/química , Materiales Dentales , Caries Dental/prevención & control , Biopelículas , Antibacterianos
17.
Dent Mater ; 38(11): 1689-1702, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36115699

RESUMEN

OBJECTIVE: A low-shrinkage-stress resin-based cement with antibacterial properties could be beneficial to create a cement with lower stress at the tooth-restoration interface, which could help to enhance the longevity of the fixed dental restoration by reducing microleakage and recurrent caries. To date, there has been no report on the development of a low-shrinkage-stress and bio-interactive cement. Therefore, the objectives of this study were to develop a novel low-shrinkage-stress resin-based cement containing dimethylaminohexadecyl methacrylate (DMAHDM) and investigate the mechanical and antibacterial properties for the first time. METHODS: The monomers urethane dimethacrylate (UDMA) and triethylene glycol divinylbenzyl ether (TEG-DVBE) were combined and denoted as UV resin. Three cements were fabricated: (1) UV+ 0%DMAHDM (experimental control); (2) UV+ 3%DMAHDM, (3) UV+ %5DMAHDM. RelyX Ultimate cement was used as commercial control. Mechanical properties and Streptococcus mutans (S. mutans) biofilms growth on cement were evaluated. RESULTS: The novel bio-interactive cement demonstrated excellent antibacterial and mechanical properties. Compared to commercial and experimental controls, adding DMAHDM into the UV cement significantly reduced colony forming unit (CFU) counts by approximately 7 orders of magnitude, metabolic activities from 0.29 ± 0.03 A540/cm2 to 0.01 ± 0.01 A540/cm2, and lactic acid production from 22.3 ± 0.74 mmol/L to 1.2 ± 0.27 mmol/L (n = 6) (p < 0.05). The low-shrinkage-stress cement demonstrated a high degree of conversion of around 70 %, while reducing the shrinkage stress by approximately 60%, compared to a commercial control (p < 0.05). CONCLUSIONS: The new antibacterial low-shrinkage-stress resin-based cement provides strong antibacterial action and maintains excellent mechanical properties with reduced polymerization shrinkage stress. CLINICAL SIGNIFICANCE: A low-shrinkage-stress resin-based cement containing DMAHDM was developed with potent antibacterial effects and promising mechanical properties. This cement may potentially enhance the longevity of fixed dental restoration such as a dental crown, inlay, onlay, and veneers through its excellent mechanical properties, low shrinkage stress, and strong antibacterial properties.


Asunto(s)
Metacrilatos , Cementos de Resina , Antibacterianos/farmacología , Biopelículas , Cementos Dentales , Materiales Dentales , Éteres , Ácido Láctico/metabolismo , Metacrilatos/farmacología , Metilaminas
18.
Restor Dent Endod ; 47(3): e29, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36090515

RESUMEN

Objectives: This study aimed to investigate the anti-erosive/abrasive effect of resin infiltration of previous deproteinized dentin. Materials and Methods: Dentin slabs were randomly assigned to 3 groups (n = 15): Control (no deproteinization; no resin infiltrant applied), RI (no deproteinization; resin infiltrant applied), and DRI (deproteinization; resin infiltrant applied). After undergoing the assigned treatment, all slabs were subjected to an in vitro cycling model for 5 days. The specimens were immersed in citric acid (0.05 M, pH = 3.75; 60 seconds; 3 times/day) and brushed (150 strokes). Between the challenges, the specimens were exposed to a remineralizing solution (60 minutes). The morphological alterations were analyzed by mechanical profilometry (µm) and scanning electron microscopy (SEM). Data were submitted to one-way analysis of variance (ANOVA) and Tukey tests (p < 0.05). Results: Control and RI groups presented mineral wear and did not significantly differ from each other (p = 0.063). DRI maintained a protective layer preserving the dentin (p < 0.001). After erosive/abrasive cycles, it was observed that in group RI, only 25% of the slabs partially evidenced the presence of the infiltrating, while, in the DRI group, 80% of the slabs presented the treated surface entirely covered by a resin-component layer protecting the dentin surface as observed in SEM images. Conclusions: The removal of the organic content allows the resin infiltrant to efficiently protect the dentin surface against erosive/abrasive lesions.

19.
J Dent ; 122: 104140, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35490839

RESUMEN

OBJECTIVE: Resin cements with remineralizing and antibacterial properties are favorable for inhibition of caries. The objectives of this study were: (1) to investigate the capability of the novel dimethylaminohexadecyl-methacrylate (DMAHDM) and nano-sized amorphous calcium phosphate (NACP) containing cement to reduce saliva microcosm biofilm, and (2) to investigate the long-term ion release, recharge, and re-release of DMAHDM-NACP cement. METHODS: Pyromellitic glycerol dimethacrylate (PMGDM) and ethoxylated bisphenol-A-dimethacrylate (EBPADMA) were used to make PEHB monomer. Five cements were fabricated: (1) PEHB+0%NACP+0%DMAHDM (experimental control); (2) PEHB+25%NACP+0%DMAHDM, (3) PEHB+25%NACP+0%DMAHDM; (4) PEHB+25%NACP+3%DMAHDM; (5) PEHB+25%NACP+5%DMAHDM. RelyX luting cement was used as commercial control. Colony-forming units (CFU), lactic acid production, metabolic activities, and minimum inhibitory concentration (MIC) were performed. Long-term Calcium (Ca) and phosphate (P) ion release, recharge, and re-release were assessed. RESULTS: Compared to experimental and commercial controls, the NACP-DMAHDM cement significantly reduced CFU biofilm by 2-3 orders of magnitude, metabolic activities from 0.24±0.06 A540/cm2 to 0.03±0.01 A540/cm2, and lactic acid production from 27.7 ± 2.5 mmol/L to 5.4 ± 2.1 mmol/L (n = 6) (p<0.05). The DMAHDM showed an MIC value of 0.03 mg/L. However, when the DMAHDM was combined with PMGDM monomer, the MIC was greater than DMAHDM alone. The ion concentrations for the experimental groups significantly increased over time (1-84 days), indicating continuous ion release (n = 3) (p<0.05). Increasing the DMAHDM mass fraction from 0% to 5% and 3% to 5% significantly enhanced ion recharge and re-release at the third cycle (p<0.05). CONCLUSIONS: Incorporating DMAHDM and NACP into resin-based crown cement provides strong antibacterial action against saliva microcosm biofilm and presents a high level of Ca and P ion recharge abilities, exhibiting long-term Ca and P ion release and remineralization potential. CLINICAL SIGNIFICANCE: Resin based cement containing NACP and DMAHDM were developed with remineralizing and potent antibacterial effects. This cement formulation showed ion release and remineralization potential and are promising formulations to inhibit the incidence of recurrent caries and could promote remineralization and be sustainable for the long term.


Asunto(s)
Caries Dental , Nanopartículas , Antibacterianos/farmacología , Biopelículas , Fosfatos de Calcio/farmacología , Coronas , Cementos Dentales/farmacología , Materiales Dentales/farmacología , Humanos , Ácido Láctico/metabolismo , Metacrilatos/farmacología , Saliva/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA