Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Ear Hear ; 42(4): 949-960, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33480623

RESUMEN

OBJECTIVES: The primary objective of this study is to identify the biographic, audiologic, and electrode position factors that influence speech perception performance in adult cochlear implant (CI) recipients implanted with a device from a single manufacturer. The secondary objective is to investigate the independent association of the type of electrode (precurved or straight) with speech perception. DESIGN: In a cross-sectional study design, speech perception measures and ultrahigh-resolution computed tomography scans were performed in 129 experienced CI recipients with a postlingual onset of hearing loss. Data were collected between December 2016 and January 2018 in the Radboud University Medical Center, Nijmegen, the Netherlands. The participants received either a precurved electrode (N = 85) or a straight electrode (N = 44), all from the same manufacturer. The biographic variables evaluated were age at implantation, level of education, and years of hearing loss. The audiometric factors explored were preoperative and postoperative pure-tone average residual hearing and preoperative speech perception score. The electrode position factors analyzed, as measured from images obtained with the ultrahigh-resolution computed tomography scan, were the scalar location, angular insertion depth of the basal and apical electrode contacts, and the wrapping factor (i.e., electrode-to-modiolus distance), as well as the type of electrode used. These 11 variables were tested for their effect on three speech perception outcomes: consonant-vowel-consonant words in quiet tests at 50 dB SPL (CVC50) and 65 dB SPL (CVC65), and the digits-in-noise test. RESULTS: A lower age at implantation was correlated with a higher CVC50 phoneme score in the straight electrode group. Other biographic variables did not correlate with speech perception. Furthermore, participants implanted with a precurved electrode and who had poor preoperative hearing thresholds performed better in all speech perception outcomes than the participants implanted with a straight electrode and relatively better preoperative hearing thresholds. After correcting for biographic factors, audiometric variables, and scalar location, we showed that the precurved electrode led to an 11.8 percentage points (95% confidence interval: 1.4-20.4%; p = 0.03) higher perception score for the CVC50 phonemes compared with the straight electrode. Furthermore, contrary to our initial expectations, the preservation of residual hearing with the straight electrode was poor, as the median preoperative and the postoperative residual hearing thresholds for the straight electrode were 88 and 122 dB, respectively. CONCLUSIONS: Cochlear implantation with a precurved electrode results in a significantly higher speech perception outcome, independent of biographic factors, audiometric factors, and scalar location.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Estudios Transversales , Humanos , Resultado del Tratamiento
2.
JACC Clin Electrophysiol ; 5(3): 318-326, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30898234

RESUMEN

OBJECTIVES: The purpose of this study was to randomly compare the incidence of asymptomatic cerebral embolism (ACE) between the second-generation pulmonary vein ablation catheter (PVAC Gold) and the irrigated Thermocool catheter. BACKGROUND: Pulmonary vein isolation (PVI) with the PVAC is associated with ACE. The PVAC Gold was designed to avoid this complication. METHODS: Patients with paroxysmal atrial fibrillation were randomized 1:1 to PVI with the PVAC Gold or Thermocool catheter. Cerebral magnetic resonance imaging was performed in the days before and after ablation and repeated after 3 months in case of a new lesion. Monitoring for microembolic signals (MES) was performed by using transcranial Doppler ultrasonography. Parameters of coagulation were determined before, during, and after ablation. Neuropsychological tests and questionnaires were applied 10 days before and 3 months after ablation. RESULTS: Seventy patients were included in the study (mean age 61 ± 9 years; 43 male subjects; CHA2DS2-VASc [congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke/transient ischemic attack, vascular disease, age 65 to 74 years, sex category] score 1.6 ± 1.2; international normalized ratio 2.7 ± 0.5; activated clotting time 374 ± 24 s; p > 0.05 for all parameters). Procedural duration was shorter in the PVAC Gold group (140 ± 34 vs. 207 ± 44 min; p < 0.001). Eight (23%; 7 infarcts) patients in the PVAC Gold group exhibited a new ACE, compared with 2 (6%; no infarcts) patients in the Thermocool group (p = 0.042). Median number of MES was higher in the PVAC Gold group (1,111 [interquartile range, 715-2,234] vs. 787 [interquartile range, 532-1,053]; p < 0.001). There were no differences between groups regarding coagulation and neuropsychological outcomes. CONCLUSIONS: PVI with the new PVAC Gold was associated with a higher incidence of ACE/cerebral infarcts and number of MES. Both catheters induced a comparable procoagulant state. Because there were no measurable differences in neuropsychological status, the clinical significance of ACE remains unclear. (Cerebral Embolism [CE] in Catheter Ablation of Atrial Fibrillation [AF] [CE-AF]; NCT01361295).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Embolia Intracraneal , Anciano , Fibrilación Atrial/mortalidad , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Ablación por Catéter/estadística & datos numéricos , Femenino , Humanos , Embolia Intracraneal/epidemiología , Embolia Intracraneal/etiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Resultado del Tratamiento
3.
Ned Tijdschr Geneeskd ; 159: A9343, 2015.
Artículo en Holandés | MEDLINE | ID: mdl-26507066

RESUMEN

A 65-year-old patient with rectal carcinoma underwent an 18FDG PET-CT scan. The scan showed nodular foci of 18FDG uptake against the ventral abdominal wall, possibly carcinomatous peritonitis. These abnormalities were caused by a foreign body reaction to a mesh that was placed five months earlier because of an umbilical hernia repair.


Asunto(s)
Reacción a Cuerpo Extraño , Tomografía de Emisión de Positrones/métodos , Mallas Quirúrgicas/efectos adversos , Anciano , Fluorodesoxiglucosa F18/uso terapéutico , Hernia Umbilical/cirugía , Humanos , Masculino , Prótesis e Implantes , Radiofármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA