J Environ Radioact ; 272: 107358, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38142518

RESUMEN

Radioactivity detection is a major research and development priority for many practical applications. Amongst the various technical challenges in this field is the need to carry out accurate low-level radioactivity measurements in the presence of a large fluctuations in the natural radiation background, while reducing the false alarm rates. The task becomes even more harder with high detection limits under low signal-to-background ratios. A detection method based on the statistical inference, following either a frequentist or a Bayesian paradigm, adopted to overcome these challenges as well as to ensure a reliable and accurate diagnosis with a competitive tradeoff between sensitivity, specificity and response time. With this respect, several research studies, addressing a range of applications from decommissioning and dismantling to homeland security, have been proposed. Our main goal in this paper is to present a succinct survey of these studies based on a frequentist and Bayesian approaches used to decision-making, uncertainty and risk evaluation, in the context of radioactive detection. In this prospect, a theoretical background of statistical frequentist and Bayesian inferences was presented. Then, a comparative study of both approaches was performed to determine the optimal approach in regards to accuracy and pros/cons. A case of study for low-level radioactivity detection in nuclear decommissioning operations was provided to validate the optimal approach. Results proved the efficiency and usefulness of Bayesian approach against frequentist one with respect to the most challenging scenarios in radiation detection applications.


Asunto(s)
Monitoreo de Radiación , Radiactividad , Teorema de Bayes , Incertidumbre
2.
Opt Lett ; 38(24): 5307-10, 2013 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-24322244

RESUMEN

It is shown that lasing can be achieved in commercial organic liquid scintillators. Using a dynamic grating induced by an interference pattern in the scintillator volume, distributed feedback lasing is shown to occur in four out of five commercial liquid scintillators that have been investigated. Although these scintillators are not designed for lasing application, their purpose being to measure radioactivity, induction of a laser effect, furthermore with a tuning range of approximately 30 nm, has been attained.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA