Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Acta Cardiol ; 78(9): 992-999, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37318077

RESUMEN

BACKGROUND: A complex transvenous lead extraction (TLE) procedure could be associated with lower success and higher complication rates in inexperienced hands. In this study, we aim to assess the factors that determine procedural difficulty in TLE. METHODS: We retrospectively studied 200 consecutive patients undergoing TLE in a single referral centre from June 2020 to December 2021. Lead extraction difficulty was assessed by the success of simple manual traction with or without a locking stylet, the need for advanced extraction tools and the number of tools required to extract the lead. Logistic and linear regression analyses were used to determine the factors independently affecting these 3 parameters. RESULTS: 363 leads were extracted from 200 patients (79% males, mean age 66.85 years). The indication for TLE was device-related infection in 51.5%. Multivariate analysis revealed the lead indwelling time to be the only factor affecting the 3 parameters of difficulty. Passive fixation leads and dual coil leads increased procedural difficulty by affecting 2 parameters each. Factors that affected one parameter included infected leads, coronary sinus leads, older age of the patient and a history of valvular heart disease, all associated with a simpler procedure. Right ventricular leads were associated with a more complex one. CONCLUSION: The most important factor that increased TLE procedural difficulty was a longer lead indwelling time, followed by passive fixation and dual-coil leads. Other contributing factors were the presence of infection, coronary sinus leads, older patients, a history of valvular heart disease and right ventricular leads.

3.
J Cardiovasc Electrophysiol ; 33(10): 2195-2201, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35842805

RESUMEN

INTRODUCTION: The prevalence and impact of pulmonary embolism (PE) in patients with lead-related infective endocarditis undergoing transvenous lead extraction (TLE) are unknown. METHODS: Twenty-five consecutive patients with vegetations ≥10 mm at transoesophageal echocardiography were prospectively studied. Contrast-enhanced chest computed tomography (CT) was performed before (pre-TLE) and after (post-TLE) the lead extraction procedure. RESULTS: Pre-TLE CT identified 18 patients (72%) with subclinical PE. The size of vegetations in patients with PE did not differ significantly from those without (median 20.0 mm [interquartile range: 13.0-30.0] vs. 14.0 mm [6.0-18.0], p = 0.116). Complete TLE success was achieved in all patients with 3 (2-3) leads extracted per procedure. There were no postprocedure complications related to the presence of PE and no differences in terms of fluoroscopy time and need for advanced tools. In the group of positive pre-TLE CT, post-TLE scan confirmed the presence of silent PE in 14 patients (78%). There were no patients with new PE formation. Large vegetations (≥20 mm) tended to increase the risk of post-TLE subclinical PE (odds ratio 5.99 [95% confidence interval (CI): 0.93-38.6], p = 0.059). During a median 19.4 months follow-up, no re-infection of the implanted system was reported. Survival rates in patients with and without post-TLE PE were similar (hazard ratio: 1.11 [95% CI: 0.18-6.67], p = 0.909). CONCLUSION: Subclinical PE detected by CT was common in patients undergoing TLE with lead-related infective endocarditis and vegetations but was not associated with the complexity of the procedure or adverse outcomes. TLE procedure seems safe and feasible even in patients with large vegetations.


Asunto(s)
Desfibriladores Implantables , Endocarditis Bacteriana , Endocarditis , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Embolia Pulmonar , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos/métodos , Endocarditis/diagnóstico por imagen , Endocarditis/epidemiología , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/epidemiología , Humanos , Marcapaso Artificial/efectos adversos , Prevalencia , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/epidemiología , Embolia Pulmonar/terapia , Estudios Retrospectivos
4.
Pacing Clin Electrophysiol ; 45(9): 1051-1055, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35579295

RESUMEN

Superior vena cava (SVC) syndrome is a rare disease induced by thrombosis and consequent occlusion of SVC, negatively affecting morbidity and mortality. The incidence of SVC syndrome from central venous catheters and pacemaker or defibrillator leads is increasing. Optimal treatment of pacemaker or defibrillator-related SVC syndrome is not well defined. Lead extraction causes mechanical trauma to the vessel wall. In addition, subsequent device implantation on the contralateral side can be an added factor for venous occlusion. The use of leadless pacemakers could be an interesting option to reduce the risk of SVC restenosis after lead extraction. We report a clinical case of PM leads-related SVC syndrome referred to our centers and treated with transvenous lead extraction, leadless pacemaker implantation and subsequent percutaneous angioplasty and stenting of the SVC and left innominate vein.


Asunto(s)
Marcapaso Artificial , Síndrome de la Vena Cava Superior , Trombosis , Humanos , Marcapaso Artificial/efectos adversos , Stents/efectos adversos , Síndrome de la Vena Cava Superior/cirugía , Síndrome de la Vena Cava Superior/terapia , Trombosis/complicaciones , Vena Cava Superior
5.
Pacing Clin Electrophysiol ; 45(7): 861-865, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35596733

RESUMEN

BACKGROUND: Transvenous lead extraction is the standard therapy for cardiac device-related infection. In some patients, however, a hybrid surgical and transvenous approach may be necessary. METHODS AND RESULTS: We present three cases who underwent transvenous lead extraction for an infected CRT-D system. In all cases the CS lead could not be retrieved transvenously due to extensive fibrosis. The lead was successfully extracted through left minithoracotomy in two patients and midline sternotomy in one patient. CONCLUSION: In cases where the coronary sinus lead shows severe fibrosis, a transvenous approach can be used to free the proximal part of the lead, while the distal adhesions can be removed surgically through a limited thoracic incision.


Asunto(s)
Seno Coronario , Desfibriladores Implantables , Seno Coronario/cirugía , Remoción de Dispositivos , Fibrosis , Humanos , Toracotomía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA