1.
JACC Cardiovasc Interv ; 17(13): 1559-1573, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986655

RESUMEN

BACKGROUND: The impact of intraprocedural results following transcatheter edge-to-edge repair (TEER) in primary mitral regurgitation (MR) is controversial. OBJECTIVES: This study sought to investigate the prognostic impact of intraprocedural residual mitral regurgitation (rMR) and mean mitral valve gradient (MPG) in patients with primary MR undergoing TEER. METHODS: The PRIME-MR (Outcomes of Patients Treated With Mitral Transcatheter Edge-to-Edge Repair for Primary Mitral Regurgitation) registry included consecutive patients with primary MR undergoing TEER from 2008 to 2022 at 27 international sites. Clinical outcomes were assessed according to intraprocedural rMR and mean MPG. Patients were categorized according to rMR (optimal result: ≤1+, suboptimal result: ≥2+) and MPG (low gradient: ≤5 mm Hg, high gradient: > 5 mm Hg). The prognostic impact of rMR and MPG was evaluated in a Cox regression analysis. The primary endpoint was 2-year all-cause mortality or heart failure hospitalization. RESULTS: Intraprocedural rMR and mean MPG were available in 1,509 patients (median age = 82 years [Q1-Q3: 76.0-86.0 years], 55.1% male). Kaplan-Meier analysis according to rMR severity showed significant differences for the primary endpoint between rMR ≤1+ (29.1%), 2+ (41.7%), and ≥3+ (58.0%; P < 0.001), whereas there was no difference between patients with a low (32.4%) and high gradient (42.1%; P = 0.12). An optimal result/low gradient was achieved in most patients (n = 1,039). The worst outcomes were observed in patients with a suboptimal result/high gradient. After adjustment, rMR ≥2+ was independently linked to the primary endpoint (HR: 1.87; 95% CI: 1.32-2.65; P < 0.001), whereas MPG >5 mm Hg was not (HR: 0.78; 95% CI: 0.47-1.31; P = 0.35). CONCLUSIONS: Intraprocedural rMR but not MPG independently predicted clinical outcomes following TEER for primary MR. When performing TEER in primary MR, optimal MR reduction seems to outweigh the impact of high transvalvular gradients.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Hemodinámica , Insuficiencia de la Válvula Mitral , Válvula Mitral , Recuperación de la Función , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Masculino , Femenino , Anciano , Resultado del Tratamiento , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Riesgo , Factores de Tiempo , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Medición de Riesgo
2.
EuroIntervention ; 20(14): e887-e897, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007829

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral regurgitation (MR) who are ineligible for conventional surgery. There are limited data on the outcomes of large patient cohorts treated with TMVR. AIMS: This study aimed to investigate the outcomes and predictors of mortality for patients treated with transapical TMVR. METHODS: This analysis represents the clinical experience of all patients enrolled in the Tendyne Expanded Clinical Study. Patients with symptomatic MR underwent transapical TMVR with the Tendyne system between November 2014 and June 2020. Outcomes and adverse events up to 2 years, as well as predictors of short-term mortality, were assessed. RESULTS: A total of 191 patients were treated (74.1±8.0 years, 62.8% male, Society of Thoracic Surgeons Predicted Risk of Mortality 7.7±6.6%). Technical success was achieved in 96.9% (185/191), and there were no intraprocedural deaths. At 30-day, 1- and 2-year follow-up, the rates of all-cause mortality were 7.9%, 30.8% and 40.5%, respectively. Complete MR elimination (MR <1+) was observed in 99.3%, 99.1% and 96.3% of patients, respectively. TMVR treatment resulted in consistent improvement of New York Heart Association Functional Class and quality of life up to 2 years (both p<0.001). Independent predictors of early mortality were age (odds ratio [OR] 1.11; p=0.003), pulmonary hypertension (OR 3.83; p=0.007), and institutional experience (OR 0.40; p=0.047). CONCLUSIONS: This study investigated clinical outcomes in the full cohort of patients included in the Tendyne Expanded Clinical Study. The Tendyne TMVR system successfully eliminated MR with no intraprocedural deaths, resulting in an improvement in symptoms and quality of life. Continued refinement of clinical and echocardiographic risks will be important to optimise longitudinal outcomes.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Masculino , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Anciano , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas , Factores de Riesgo , Persona de Mediana Edad
3.
EClinicalMedicine ; 72: 102603, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39010979

RESUMEN

Background: The permanent pacemaker (PPM) implantation and pacemaker dependency rates after transcatheter aortic valve replacement (TAVR) are highly variable as some of the conduction disturbances are reversible. It remains poorly investigated how to optimise temporary pacing in these patients. This study aimed to explore the potential reduction in the PPM implantation rate using temporary-permanent pacemaker (TPPM) as a 1-month bridge. Methods: This is a prospective, multicentre, single-arm, observational study. Consecutive patients undergoing TAVR from March 1, 2022 to March 1, 2023 in 13 tertiary hospitals in China were screened. Patients who developed high-degree atrioventricular block, complete heart block, or first-degree atrioventricular block plus new onset left bundle branch block during the TAVR procedure or within 1 month after TAVR were included to receive TPPM. Patients with pre-existing PPM implantation or indications for PPM implantation before the TAVR procedure were excluded. Patients with TPPM were monitored to determine whether the conduction disturbances persisted or recovered. The primary endpoint was the rate of freedom from indications for PPM implantation 1 month after TAVR. This study is registered with ChiCTR, ChiCTR2200057931. Findings: Of 688 patients who have undergone TAVR, 71 developed conduction disturbance and met the inclusion criteria, 1 patient withdrew due to noncompliance, 70 patients received TPPM and completed follow-up. There were 41 (58.6%) men and 29 (41.4%) women in the study, with a mean age of 74.3 ± 7.3 years. At 1 month follow-up, 75.7% (53/70) of the patients with TPPM did not require PPM implantation. For 688 patients who have undergone TAVR, the rate of PPM implantation at 1 month was 2.47% (17/688, 95% CI 1.55%-3.92%), representing a significant reduction in self-comparison with the rate at 48 h after TPPM (2.47% vs. 8.28% [95% CI 6.45%-10.58%], P < 0.0001). Similar results were obtained in the subgroup analysis of patients with HAVB/CHB. Multivariate analysis revealed the baseline PR interval, difference between the membranous septum length and implantation depth, and timing of postprocedural conduction disturbance occurrence were independent predictors of freedom from indications for PPM implantation at 1 month after TAVR. Interpretation: Using TPPM as a 1-month bridge allows for a buffer period to distinguish whether conduction disturbances are reversible or persistent, resulting in a significant reduction in the PPM implantation rate after TAVR when compared with the current strategy. However, this is an observational study, the results need to be confirmed in a randomized trial. Funding: Beijing Science and Technology Plan 2022 from Beijing Municipal Science & Technology Commission.

4.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

5.
Struct Heart ; 8(3): 100294, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38799804

RESUMEN

Background: Treatment options for patients with mitral regurgitation (MR) and mitral annular calcification (MAC) are limited. The limitations of current transcatheter mitral valve replacement (TMVR) technologies include high screen failure rates, increased risk of left ventricular outflow tract obstruction, and high residual regurgitation. The aim of this study was to evaluate outcomes of TMVR with the AltaValve system (4C Medical, Maple Grove, MN), a supra-annular TMVR with atrial fixation, in patients with severe MR and moderate or severe MAC. Methods: Six patients with moderate or severe MAC who were treated with AltaValve TMVR had procedural and mid-term outcomes available. Results: Technical success was achieved in all patients. Median follow-up was 232 days. At discharge, 80% of patients had none/trace MR, and 20% had mild MR. There was no intraprocedural mortality, device malposition, embolization, or thrombosis. One patient expired 3 days postprocedure due to complications related to the transapical access. All other patients were discharged from the hospital without issues. Echocardiography assessments at 30 days showed complete resolution of MR in all patients, with 1 patient with mild MR and a mean mitral valve gradient of 3.7 ± 1.4 mmHg. All patients were in New York Heart Association Class I/II at 30-day follow-up, showing marked improvement as compared with baseline. Conclusions: In patients with severe MR and severe MAC, the AltaValve TMVR technology may represent a viable treatment option. The atrial fixation minimizes the risk of left ventricular outflow tract obstruction and potentially expands treatable patients, especially in patients with MAC.

7.
Eur Heart J ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

8.
JACC Cardiovasc Interv ; 17(12): 1485-1495, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38752971

RESUMEN

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/mortalidad , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Tricúspide/fisiopatología , Anciano , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Cateterismo Cardíaco/instrumentación , Factores de Tiempo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Factores de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad , Medición de Riesgo , Sistema de Registros
9.
Eur J Clin Invest ; : e14241, 2024 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-38767226

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.

11.
JACC Cardiovasc Interv ; 17(12): 1440-1451, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38639690

RESUMEN

BACKGROUND: Thirty-day outcomes with the investigational Intrepid transapical (TA) transcatheter mitral valve replacement (TMVR) system have previously demonstrated good technical success, but longer-term outcomes in larger cohorts need to be evaluated. OBJECTIVES: The authors sought to evaluate the 2-year safety and performance of the Intrepid TA-TMVR system in patients with symptomatic, ≥moderate-severe mitral regurgitation (MR) and high surgical risk. METHODS: Patient eligibility was determined by local heart teams and approved by a central screening committee. Clinical events were adjudicated by an independent clinical events committee. Echocardiography was evaluated by an independent core laboratory. RESULTS: The cohort included 252 patients that were enrolled at 58 international sites before February 2021 as part of the global Pilot Study (n = 95) or APOLLO trial (primary cohort noneligible + TA roll-ins, n = 157). Mean age was 74.2 years, mean STS-PROM was 6.3%, 60.3% were male, and 80.6% were in NYHA functional class III/IV. Most presented with secondary MR (70.1%), and nearly all had ≥moderate-severe MR (98.4%). All-cause mortality was 13.1% (30-day), 27.3% (1-year), and 36.2% (2-year). The 30-day ≥major bleeding event rate was 22.3%. Heart failure rehospitalization was 9.6% (30-day) and 36.2% (2-year). At 2 years, >50% of patients were alive with improvement in NYHA functional class (82.1%, class I/II), and all patients with available echocardiograms had ≤mild MR. CONCLUSIONS: This analysis represents the largest reported TA-TMVR experience with the longest follow-up in high-risk ≥moderate-severe MR patients. Early mortality and heart failure rehospitalizations were significant, exacerbated by early TA-related bleeding events; however, meaningful improvements in clinical outcomes and marked reductions in MR severity were observed through 2 years.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Femenino , Masculino , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Diseño de Prótesis , Valor Predictivo de las Pruebas , Complicaciones Posoperatorias/etiología , Persona de Mediana Edad , Hemodinámica , Readmisión del Paciente , Ecocardiografía
12.
Am J Cardiol ; 223: 147-155, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38641189

RESUMEN

There are limited data from randomized controlled trials assessing the impact of transcatheter aortic valve replacement (TAVR) or surgery in women with aortic stenosis and small aortic annuli. We evaluated 2-year clinical and hemodynamic outcomes after aortic valve replacement to understand acute valve performance and early and midterm clinical outcomes. This post hoc analysis pooled women enrolled in the randomized, prospective, multicenter Evolut Low Risk and Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) intermediate risk trials. Women with severe aortic stenosis at low or intermediate surgical risk who had a computed tomography-measured annular perimeter of ≤72.3 mm were included and underwent self-expanding, supra-annular TAVR or surgery. The primary end point was 2-year all-cause mortality or disabling stroke rate. The study included 620 women (323 TAVR, 297 surgery) with a mean age of 78 years. At 2 years, the all-cause mortality or disabling stroke was 6.5% for TAVR and 8.0% for surgery, p = 0.47. Pacemaker rates were 20.0% for TAVR and 8.3% for surgery, p <0.001. The mean effective orifice area at 2 years was 1.9 ± 0.5 cm2 for TAVR and 1.6 ± 0.5 cm2 for surgery and the mean gradient was 8.0 ± 4.1 versus 12.7 ± 6.0 mm Hg, respectively (both p <0.001). Moderate or severe patient-prothesis mismatch at discharge occurred in 10.9% of patients who underwent TAVR and 33.2% of patients who underwent surgery, p <0.001. In conclusion, in women with small annuli, the clinical outcomes to 2 years were similar between self-expanding, supra-annular TAVR and surgery, with better hemodynamics in the TAVR group and fewer pacemakers in the surgical group.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estudios Prospectivos , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Factores de Riesgo , Índice de Severidad de la Enfermedad , Medición de Riesgo/métodos , Complicaciones Posoperatorias/epidemiología , Tomografía Computarizada por Rayos X , Prótesis Valvulares Cardíacas
14.
Front Cardiovasc Med ; 11: 1334871, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38440208

RESUMEN

Transcatheter aortic valve replacement (TAVR) has emerged as a viable treatment for aortic valve disease, including low-risk patients. However, as TAVR usage increases, concerns about long-term durability and the potential for addition interventions have arisen. Transcatheter aortic valve (TAV)-in-TAV procedures have shown promise in selected patients in numerous registries, offering a less morbid alternative to TAVR explantation. In this review, the authors aimed to comprehensively review the experience surrounding TAV-in-TAV, summarize available data, discuss pre-procedural planning, highlight associated challenges, emphasize the importance of coronary obstruction assessment and provide insights into the future of this technique.

16.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38532517

RESUMEN

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Asunto(s)
Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Falla de Prótesis , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38418058

RESUMEN

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Recuperación de la Función , Factores de Tiempo , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Sistema de Registros
19.
Am Heart J ; 270: 86-94, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38309610

RESUMEN

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Puente de Arteria Coronaria , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38385922

RESUMEN

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Sistema de Registros