Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Asunto de la revista
Intervalo de año de publicación
1.
BMC Oral Health ; 24(1): 410, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566034

RESUMEN

BACKGROUND: To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS: The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS: Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION: Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.


Asunto(s)
Implantes Dentales , Boca Edéntula , Humanos , Flujo de Trabajo , Técnica de Impresión Dental , Tornillos Óseos , Diseño Asistido por Computadora , Prótesis Dental de Soporte Implantado/métodos , Diseño de Prótesis Dental
2.
Int J Oral Maxillofac Implants ; 37(4): 763-770, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35904833

RESUMEN

PURPOSE: To find out the difference in the stresses induced by one-piece monophasic and two-piece dental implants supporting All-on-4 implant-supported prostheses using finite element analysis. MATERIALS AND METHODS: Two finite element maxillary models were designed: In the two-piece model, two-piece dental implants were used, and in the one-piece model, one-piece dental implants were used. The dental implants were placed according to the All-on-4 treatment concept. The anterior implants were axially placed; however, the posterior implants were placed with a distal inclination of 15 degrees. In each model, the prosthetic superstructure was designed to be a titanium implant prosthesis with zirconia crowns. Three loading scenarios were applied in this study. The first scenario simulated biting function with a total load of 250 N. The second scenario simulated incision function in which 90-N horizontal static load was applied to the palatal surface of central incisors. The third scenario simulated biting in the presence of a cantilever. RESULTS: In the three loading scenarios, the stresses were higher in the two-piece model. Higher stress values were recorded posteriorly rather than anteriorly in both models. CONCLUSION: One-piece dental implants induce lower stress values compared with two-piece dental implants when used in All-on-4 implant-supported prostheses.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental , Análisis de Elementos Finitos , Estrés Mecánico
3.
BMC Oral Health ; 22(1): 196, 2022 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-35599323

RESUMEN

BACKGROUND: Correct choice of the implant design and the occlusal scheme is important for the success of implant supported restorations. So, the aim of the current study was to find out the difference in the stresses induced by the one piece dental implants designed to be used in the All-on-4® concept and the conventional two piece ones under simulated lateral occlusal schemes using nonlinear finite element analysis. METHODS: Two finite element models of the maxilla, implants, and prostheses were designed according to the All-on-4® concept. In the model TP, two piece dental implants were placed while in the model OP one piece dental implants were used. Two loading scenarios were applied to each model; the first one simulated a group function occlusal scheme while the second scenario simulated a canine guided one. RESULTS: The highest stress value was recorded in the model TP with the group function occlusion and the lowest stress value was in the model OP with the canine guidance occlusion. CONCLUSION: The one-piece dental implants can be concluded to induce less stress compared to the two piece dental implants when used in the All-on-4® implant supported prosthesis in the different lateral occlusal schemes. Canine guided occlusion can be concluded to cause lower stress values in comparison to the group function occlusal scheme.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental , Análisis de Elementos Finitos , Humanos , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA