Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 417
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38768299

RESUMEN

Longitudinal dyssynchrony correction and strain improvement by comparable cardiac resynchronization therapy techniques is unreported. AIMS: Our purpose was to compare echocardiographic dyssynchrony correction and strain improvement by conduction system pacing (CSP) vs. biventricular pacing (BiVP) as a marker of contractility improvement during one-year follow-up. METHODS AND RESULTS: A treatment-received analysis was performed in patients included in the LEVEL-AT trial (NCT04054895), randomized to CSP or BiVP, and evaluated at baseline (ON and OFF programming) and at 6 and 12 months (n = 69, 32% women). Analysis included intraventricular (septal flash), interventricular (difference between left and right ventricular outflow times), and atrioventricular (diastolic filling time) dyssynchrony and strain parameters (septal bounce, global longitudinal strain [GLS], left bundle branch block pattern and mechanical dispersion).Baseline left ventricular ejection fraction (LVEF) was 27.5 ± 7% and left ventricular end-systolic volume (LVESV) was 138 ± 77 ml, without differences between groups. Longitudinal analysis showed LVEF and LVESV improvement (p < 0.001), without between-group differences. At 12-month follow-up, adjusted mean LVEF was 46% with CSP (95%CI 42.2%, 49.3%) vs. 43% with BiVP (95%CI 39.6%, 45.8%) (p = 0.31) and LVESV was 80 ml (95%CI 55.3 ml, 104.5 ml) vs. 100 ml (95%CI 78.7 ml, 121.6 ml), respectively (p = 0.66).Longitudinal analysis showed a significative improvement of all dyssynchrony parameters and GLS over time (p < 0.001), without differences between groups. Baseline GLS significantly correlated with LVEF and LVESV at 12-month follow-up. CONCLUSION: CSP and BiVP provided similar dyssynchrony and strain correction over time. Baseline global longitudinal strain correction predicted ventricular remodeling at 12-month follow-up.

2.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

3.
Artículo en Inglés | MEDLINE | ID: mdl-38819348

RESUMEN

BACKGROUND: A partial delineation of targets for ablation of ventricular tachycardia (VT) during a stable rhythm is likely responsible for a suboptimal success rate. The abnormal low-voltage near-field functional components may be hidden within the high-amplitude far-field signal. OBJECTIVES: The aim of this study was to evaluate the benefit and feasibility of functional substrate mapping using a full-ventricle S3 protocol and to assess its colocalization with arrhythmogenic conducting channels (CCs) on late gadolinium enhancement cardiac magnetic resonance. METHODS: An S3 mapping protocol with a drive train of S1 followed by S2 (effective refractory period + 30 ms) and S3 (effective refractory period + 50 ms) from the right ventricular apex was performed in 40 consecutive patients undergoing scar-related VT ablation. Deceleration zones (DZs) and areas of late potentials (LPs) were identified for all maps. A preprocedural noninvasive substrate assessment was done using late gadolinium enhancement cardiac magnetic resonance and postprocessing with automated CC identification. RESULTS: The S3 protocol was completed in 34 of the 40 procedures (85.0%). The S3 protocol enhanced the identification of VT isthmus on the basis of DZ (89% vs 62%; P < 0.01) and LP (93% vs 78%; P = 0.04) assessment. The percentage of CCs unmasked by DZs and LPs using S3 maps was significantly higher than the ones using S2 and S1 maps (78%, 65%, and 48% [P < 0.001] and 88%, 81%, and 68% [P < 0.01], respectively). The functional substrate identified during S3 activation mapping was significantly more extensive than the one identified using S2 and S1, including a greater number of DZs (2.94, 2.47, and 1.82, respectively; P < 0.001) and a wider area of LPs (44.1, 38.2, and 29.4 cm2, respectively; P < 0.001). After VT ablation, 77.9% of patients have been VT free during a median follow-up period of 13.6 months. CONCLUSIONS: The S3 protocol was feasible in 85% of patients, allows a better identification of targets for ablation, and might improve VT ablation results.

4.
Heart Rhythm ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38763377

RESUMEN

Youth and adult participation in sports continues to increase, and athletes may be diagnosed with potentially arrhythmogenic cardiac conditions. This international multidisciplinary document is intended to guide electrophysiologists, sports cardiologists, and associated health care team members in the diagnosis, treatment, and management of arrhythmic conditions in the athlete with the goal of facilitating return to sport and avoiding the harm caused by restriction. Expert, disease-specific risk assessment in the context of athlete symptoms and diagnoses is emphasized throughout the document. After appropriate risk assessment, management of arrhythmias geared toward return to play when possible is addressed. Other topics include shared decision-making and emergency action planning. The goal of this document is to provide evidence-based recommendations impacting all areas in the care of athletes with arrhythmic conditions. Areas in need of further study are also discussed.

5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38571291

RESUMEN

AIMS: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is an effective means to spare healthcare resources. However, safety remains a concern, and besides structural adaptations, SDD requires more efficient logistics and coordination. Therefore, in this study, we implement a streamlined, nurse-coordinated SDD programme following a standardized protocol. METHODS AND RESULTS: As a dedicated SDD coordinator, a nurse specialized in ambulatory cardiac interventions was in charge of the full SDD protocol, including eligibility, patient flow, in-hospital logistics, patient education, and discharge as well as early post-discharge follow-up by smartphone-based virtual visits. Patients planned for AF ablation were considered eligible if they had a left ventricular ejection fraction (LVEF) ≥35%, with basic support at home and accessibility of the hospital within 60 min also forming a part of the eligibility criteria. A total of 420 consecutive patients were screened by the SDD coordinator, of whom 331 were eligible for SDD. The reasons for exclusion were living remotely (29, 6.9%), lack of support at home (19, 4.5%), or LVEF <35% (17, 4.0%). Of the eligible patients, 300 (91%) were successfully discharged the same day. There were no major post-SDD complications. Rates of unplanned medical attention (19, 6.3%) and 30-day readmission (5, 1.6%) were extremely low and driven by femoral access-site complications. These were significantly reduced upon the introduction of compulsory ultrasound-guided punctures after the initial 150 SDD patients (P = 0.0145). Standardized SDD coordination resulted in efficient workflows and reduced the total workload of the medical staff. CONCLUSION: Same-day discharge after AF ablation following a nurse-coordinated standardized protocol is safe and efficient. The concept of ambulatory cardiac intervention nurses functioning as dedicated coordinators may be key in the future transition of hospitals to SDD. Ultrasound-guided femoral puncture virtually eliminated relevant femoral access-site complications in our cohort and should therefore be a prerequisite for SDD.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Alta del Paciente , Volumen Sistólico , Cuidados Posteriores , Función Ventricular Izquierda , Estudios Retrospectivos , Resultado del Tratamiento
7.
Heart Rhythm ; 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38670249

RESUMEN

BACKGROUND: Voltage mapping could identify the conducting channels potentially responsible for ventricular tachycardia (VT). Standard thresholds (0.5-1.5 mV) were established using bipolar catheters. No thresholds have been analyzed with high-density mapping catheters. In addition, channels identified by cardiac magnetic resonance (CMR) has been proven to be related with VT. OBJECTIVE: The purpose of this study was to analyze the diagnostic yield of a personalized voltage map using CMR to guide the adjustment of voltage thresholds. METHODS: All consecutive patients with scar-related VT undergoing ablation after CMR (from October 2018 to December 2020) were included. First, personalized CMR-guided voltage thresholds were defined systematically according to the distribution of the scar and channels. Second, to validate these new thresholds, a comparison with standard thresholds (0.5-1.5 mV) was performed. Tissue characteristics of areas identified as deceleration zones (DZs) were recorded for each pair of thresholds. In addition, the relation of VT circuits with voltage channels was analyzed for both maps. RESULTS: Thirty-two patients were included [mean age 66.6 ± 11.2 years; 25 (78.1%) ischemic cardiomyopathy]. Overall, 52 DZs were observed: 44.2% were identified as border zone tissue with standard cutoffs vs 75.0% using personalized voltage thresholds (P = .003). Of the 31 VT isthmuses detected, only 35.5% correlated with a voltage channel with standard thresholds vs 74.2% using adjusted thresholds (P = .005). Adjusted cutoff bipolar voltages that better matched CMR images were 0.51 ± 0.32 and 1.79 ± 0.71 mV with high interindividual variability (from 0.14-1.68 to 0.7-3.21 mV). CONCLUSION: Personalized voltage CMR-guided personalized voltage maps enable a better identification of the substrate with a higher correlation with both DZs and VT isthmuses than do conventional voltage maps using fixed thresholds.

8.
Heart Rhythm ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38636930

RESUMEN

BACKGROUND: Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction velocities have been linked to adverse outcome. However, a noninvasive method to assess such electrophysiologic substrate is not available to date. OBJECTIVE: This study aimed to noninvasively assess regional conduction velocities and their association with arrhythmia-free survival after PVI. METHODS: A consecutive 52 patients scheduled for AF ablation (PVI only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to noninvasively determine regional atrial conduction velocities in sinus rhythm. A novel ECGi technology obviating the need of additional computed tomography or cardiac magnetic resonance imaging was applied and validated by invasive mapping. RESULTS: Mean ECGi-determined atrial conduction velocities were significantly lower in AF patients than in healthy controls (1.45 ± 0.15 m/s vs 1.64 ± 0.15 m/s; P < .0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction velocity in each patient (0.8 ± 0.22 m/s vs 1.08 ± 0.26 m/s; P < .0001). This average conduction velocity of the "slowest" segment was independently associated with arrhythmia recurrence and better discriminated between PVI responders and nonresponders than previously proposed predictors, including left atrial size and late gadolinium enhancement (magnetic resonance imaging). Patients without slow-conduction areas (mean conduction velocity <0.78 m/s) showed significantly higher 12-month arrhythmia-free survival than those with 1 or more slow-conduction areas (88.9% vs 48.0%; P = .002). CONCLUSION: This is the first study to investigate regional atrial conduction velocities noninvasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI responders from nonresponders. Such noninvasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step toward personalized AF therapy.

9.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38591838

RESUMEN

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Riesgo , Hemorragia , Anticoagulantes/uso terapéutico
10.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38428580

RESUMEN

Atrial fibrillation (AF) causes progressive structural and electrical changes in the atria that can be summarized within the general concept of atrial remodeling. In parallel, other clinical characteristics and comorbidities may also affect atrial tissue properties and make the atria susceptible to AF initiation and its long-term persistence. Overall, pathological atrial changes lead to atrial cardiomyopathy with important implications for rhythm control. Although there is general agreement on the role of the atrial substrate for successful rhythm control in AF, the current classification oversimplifies clinical management. The classification uses temporal criteria and does not establish a well-defined strategy to characterize the individual-specific degree of atrial cardiomyopathy. Better characterization of atrial cardiomyopathy may improve the decision-making process on the most appropriate therapeutic option. We review current scientific evidence and propose a practical characterization of the atrial substrate based on 3 evaluation steps starting with a clinical evaluation (step 1), then assess outpatient complementary data (step 2), and finally include information from advanced diagnostic tools (step 3). The information from each of the steps or a combination thereof can be used to classify AF patients in 4 stages of atrial cardiomyopathy, which we also use to estimate the success on effective rhythm control.

11.
Circ Arrhythm Electrophysiol ; 17(3): e012255, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38318720

RESUMEN

BACKGROUND: Pulsed field ablation uses electrical fields to cause nonthermal cell death over several hours. Polarization-sensitive optical coherence reflectometry is an optical imaging technique that can detect changes in the tissue ultrastructure in real time, which occurs when muscular tissue is damaged. The objective of this study was to evaluate the ability of a polarization-sensitive optical coherence reflectometry system to predict the development of chronic lesions based on acute changes in tissue birefringence during pulsed field ablation. METHODS: Superior vena cava isolation was performed in 30 swine using a biphasic, bipolar pulsed field ablation system delivered with a nonirrigated focal tip catheter. Acute changes in tissue birefringence and voltage abatement were analyzed for each individual lesion. A high-resolution electroanatomical map was performed at baseline and 4 to 12 weeks after ablation to locate electrical gaps in the ablated area. RESULTS: A total of 141 lesions were delivered and included in the analysis. Acute electrical isolation based on the electroanatomical map was achieved in 96% of the animals, but chronic isolation was only seen in 14 animals (46%). The mean voltage abatement of lesions that showed recovery was 82.8%±14.6% versus 84.4%±17.4% for those that showed fibrosis (P=0.7). The mean acute reduction in tissue birefringence in points demonstrating fibrosis was 63.8%±11.3% versus 9.1%±0.1% in the points that resulted in electrical gaps. A threshold of acute reduction of birefringence of ≥20% could predict chronic lesion formation with a sensitivity of 96% and a specificity of 83%. CONCLUSIONS: Acute tissue birefringence changes assessed with polarization-sensitive optical coherence reflectometry during pulsed field ablation can predict chronic lesion formation and guide the ablation procedure although limited by the tissue thickness.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Vena Cava Superior/cirugía , Tórax , Venas Pulmonares/cirugía , Fibrosis , Resultado del Tratamiento
12.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38262674

RESUMEN

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Frecuencia Cardíaca/fisiología , Arritmias Cardíacas , Cicatriz/patología , Ablación por Catéter/métodos
13.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38266130

RESUMEN

AIMS: Different disease processes can combine to cause atrial fibrillation (AF). Their contribution to recurrent AF after ablation in patients is not known. Cardiovascular processes associated with recurrent AF after AF ablation were determined by quantifying biomolecules related to inflammation, metabolism, proliferation, fibrosis, shear stress, atrial pressure, and others in the AXAFA biomolecule study. METHODS AND RESULTS: Twelve circulating cardiovascular biomolecules (ANGPT2, BMP10, CA125, hsCRP, ESM1, FABP3, FGF23, GDF15, IGFBP7, IL6, NT-proBNP, and hsTnT) were quantified in plasma samples obtained prior to a first AF ablation using high-throughput, high-precision assays. Cox regression was used to identify biomolecules associated with recurrent AF during the first 3 months after AF ablation. In 433 patients (64 years [58, 70]; 33% women), baseline concentrations of ANGPT2, BMP10, hsCRP, FGF23, FABP3, GDF15, and NT-proBNP were elevated in patients with recurrent AF (120/433; 28%). After adjustment for 11 clinical features and randomized treatment, elevated NT-proBNP [hazard ratio (HR) 1.58, 95% confidence interval (1.29, 1.94)], ANGPT2 [HR 1.37, (1.12, 1.67)], and BMP10 [HR 1.24 (1.02, 1.51)] remained associated with recurrent AF. Concentrations of ANGPT2, BMP10, and NT-proBNP decreased in patients who remained arrhythmia free, but not in patients with recurrent AF, highlighting their connection to AF. The other eight biomarkers showed unchanged concentrations. CONCLUSION: Elevated concentrations of ANGPT2, BMP10, and NT-proBNP are associated with recurrent AF after a first AF ablation, suggesting that processes linked to disturbed cardiomyocyte metabolism, altered atrial shear stress, and increased load contribute to AF after AF ablation in patients.


Asunto(s)
Fibrilación Atrial , Humanos , Femenino , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Proteína C-Reactiva , Atrios Cardíacos , Péptido Natriurético Encefálico , Biomarcadores , Modelos de Riesgos Proporcionales , Fragmentos de Péptidos , Proteínas Morfogenéticas Óseas
14.
J Cardiovasc Magn Reson ; 26(1): 100995, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38219955

RESUMEN

Cardiovascular magnetic resonance (CMR) is a proven imaging modality for informing diagnosis and prognosis, guiding therapeutic decisions, and risk stratifying surgical intervention. Patients with a cardiac implantable electronic device (CIED) would be expected to derive particular benefit from CMR given high prevalence of cardiomyopathy and arrhythmia. While several guidelines have been published over the last 16 years, it is important to recognize that both the CIED and CMR technologies, as well as our knowledge in MR safety, have evolved rapidly during that period. Given increasing utilization of CIED over the past decades, there is an unmet need to establish a consensus statement that integrates latest evidence concerning MR safety and CIED and CMR technologies. While experienced centers currently perform CMR in CIED patients, broad availability of CMR in this population is lacking, partially due to limited availability of resources for programming devices and appropriate monitoring, but also related to knowledge gaps regarding the risk-benefit ratio of CMR in this growing population. To address the knowledge gaps, this SCMR Expert Consensus Statement integrates consensus guidelines, primary data, and opinions from experts across disparate fields towards the shared goal of informing evidenced-based decision-making regarding the risk-benefit ratio of CMR for patients with CIEDs.

15.
Medicina (Kaunas) ; 60(1)2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38256411

RESUMEN

Background and Objectives: Left atrial (LA) remodelling and dilatation predicts atrial fibrillation (AF) recurrences after catheter ablation. However, whether right atrial (RA) remodelling and dilatation predicts AF recurrences after ablation has not been fully evaluated. Materials and Methods: This is an observational study of 85 consecutive patients (aged 57 ± 9 years; 70 [82%] men) who underwent cardiac magnetic resonance before first catheter ablation for AF (40 [47.1%] persistent AF). Four-chamber cine-sequence was selected to measure LA and RA area, and ventricular end-systolic image phase to obtain atrial 3D volumes. The effect of different variables on event-free survival was investigated using the Cox proportional hazards model. Results: In patients with persistent AF, combined LA and RA area indexed to body surface area (AILA + RA) predicted AF recurrences (HR = 1.08, 95% CI 1.00-1.17, p = 0.048). An AILA + RA cut-off value of 26.7 cm2/m2 had 72% sensitivity and 73% specificity for predicting recurrences in patients with persistent AF. In this group, 65% of patients with AILA + RA > 26.7 cm2/m2 experienced AF recurrence within 2 years of follow-up (median follow-up 11 months), compared to 25% of patients with AILA + RA ≤ 26.7 cm2/m2 (HR 4.28, 95% CI 1.50-12.22; p = 0.007). Indices of LA and RA dilatation did not predict AF recurrences in patients with paroxysmal AF. Atrial 3D volumes did not predict AF recurrences after ablation. Conclusions: In this pilot study, the simple measurement of AILA + RA may predict recurrences after ablation of persistent AF, and may outperform measurements of atrial volumes. In paroxysmal AF, atrial dilatation did not predict recurrences. Further studies on the role of RA and LA remodelling are needed.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Masculino , Humanos , Femenino , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Proyectos Piloto , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos
16.
Eur Heart J ; 45(10): 837-849, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-37956458

RESUMEN

BACKGROUND AND AIMS: Patients with long atrial high-rate episodes (AHREs) ≥24 h and stroke risk factors are often treated with anticoagulation for stroke prevention. Anticoagulation has never been compared with no anticoagulation in these patients. METHODS: This secondary pre-specified analysis of the Non-vitamin K antagonist Oral anticoagulants in patients with Atrial High-rate episodes (NOAH-AFNET 6) trial examined interactions between AHRE duration at baseline and anticoagulation with edoxaban compared with placebo in patients with AHRE and stroke risk factors. The primary efficacy outcome was a composite of stroke, systemic embolism, or cardiovascular death. The safety outcome was a composite of major bleeding and death. Key secondary outcomes were components of these outcomes and electrocardiogram (ECG)-diagnosed atrial fibrillation. RESULTS: Median follow-up of 2389 patients with core lab-verified AHRE was 1.8 years. AHRE ≥24 h were present at baseline in 259/2389 patients (11%, 78 ± 7 years old, 28% women, CHA2DS2-VASc 4). Clinical characteristics were not different from patients with shorter AHRE. The primary outcome occurred in 9/132 patients with AHRE ≥24 h (4.3%/patient-year, 2 strokes) treated with anticoagulation and in 14/127 patients treated with placebo (6.9%/patient-year, 2 strokes). Atrial high-rate episode duration did not interact with the efficacy (P-interaction = .65) or safety (P-interaction = .98) of anticoagulation. Analyses including AHRE as a continuous parameter confirmed this. Patients with AHRE ≥24 h developed more ECG-diagnosed atrial fibrillation (17.0%/patient-year) than patients with shorter AHRE (8.2%/patient-year; P < .001). CONCLUSIONS: This hypothesis-generating analysis does not find an interaction between AHRE duration and anticoagulation therapy in patients with device-detected AHRE and stroke risk factors. Further research is needed to identify patients with long AHRE at high stroke risk.


Asunto(s)
Fibrilación Atrial , Piridinas , Accidente Cerebrovascular , Tiazoles , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/diagnóstico , Atrios Cardíacos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/diagnóstico , Anticoagulantes/uso terapéutico
17.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37819047

RESUMEN

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Miocardio/patología , Medios de Contraste , Imagen por Resonancia Cinemagnética/métodos , Cicatriz/patología , Estudios Prospectivos , Gadolinio , Imagen por Resonancia Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/patología , Espectroscopía de Resonancia Magnética
18.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-37897713

RESUMEN

AIMS: Left atrial catheter ablation is well established in patients with symptomatic atrial fibrillation (AF) but associated with risk of embolism to the brain. The present analysis aims to assess the impact of diffusion-weighted imaging (DWI) slice thickness on the rate of magnetic resonance imaging (MRI)-detected ischaemic brain lesions after ablation. METHODS AND RESULTS: AXAFA-AFNET 5 trial (NCT02227550) participants underwent MRI using high-resolution (hr) DWI (slice thickness: 2.5-3 mm) and standard DWI (slice thickness: 5-6 mm) within 3-48 h after ablation. In 321 patients with analysable brain MRI (mean age 64 years, 33% female, median CHA2DS2-VASc 2), hrDWI detected at least one acute brain lesion in 84 (26.2%) patients and standard DWI in 60 (18.7%; P < 0.01) patients. High-resolution diffusion-weighted imaging detected more lesions compared to standard DWI (165 vs. 104; P < 0.01). The degree of agreement for lesion confirmation using hrDWI vs. standard DWI was substantial (κ = 0769). Comparing the proportion of DWI-detected lesions, lesion distribution, and total lesion volume per patient, there was no difference in the cohort of participants undergoing MRI at 1.5 T (n = 52) vs. 3 T (n = 269). CONCLUSION: The pre-specified AXAFA-AFNET 5 sub-analysis revealed significantly increased rates of MRI-detected acute brain lesions using hrDWI instead of standard DWI in AF patients undergoing ablation. In comparison to DWI slice thickness, MRI field strength had a no significant impact in the trial. Comparing the varying rates of ablation-related MRI-detected brain lesions across previous studies has to consider these technical parameters. Future studies should use hrDWI, as feasibility was demonstrated in the multicentre AXAFA-AFNET 5 trial.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Femenino , Persona de Mediana Edad , Masculino , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos
19.
Sci Rep ; 13(1): 16743, 2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37798357

RESUMEN

Early detection of atrial fibrillation (AF) enables initiation of anticoagulation and early rhythm control therapy to reduce stroke, cardiovascular death, and heart failure. In a cross-sectional, observational study, we aimed to identify a combination of circulating biomolecules reflecting different biological processes to detect prevalent AF in patients with cardiovascular conditions presenting to hospital. Twelve biomarkers identified by reviewing literature and patents were quantified on a high-precision, high-throughput platform in 1485 consecutive patients with cardiovascular conditions (median age 69 years [Q1, Q3 60, 78]; 60% male). Patients had either known AF (45%) or AF ruled out by 7-day ECG-monitoring. Logistic regression with backward elimination and a neural network approach considering 7 key clinical characteristics and 12 biomarker concentrations were applied to a randomly sampled discovery cohort (n = 933) and validated in the remaining patients (n = 552). In addition to age, sex, and body mass index (BMI), BMP10, ANGPT2, and FGF23 identified patients with prevalent AF (AUC 0.743 [95% CI 0.712, 0.775]). These circulating biomolecules represent distinct pathways associated with atrial cardiomyopathy and AF. Neural networks identified the same variables as the regression-based approach. The validation using regression yielded an AUC of 0.719 (95% CI 0.677, 0.762), corroborated using deep neural networks (AUC 0.784 [95% CI 0.745, 0.822]). Age, sex, BMI and three circulating biomolecules (BMP10, ANGPT2, FGF23) are associated with prevalent AF in unselected patients presenting to hospital. Findings should be externally validated. Results suggest that age and different disease processes approximated by these three biomolecules contribute to AF in patients. Our findings have the potential to improve screening programs for AF after external validation.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Masculino , Anciano , Femenino , Angiopoyetina 2 , Estudios Transversales , Biomarcadores , Accidente Cerebrovascular/complicaciones , Factores de Riesgo , Proteínas Morfogenéticas Óseas/uso terapéutico
20.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37751383

RESUMEN

AIMS: Recurrence of arrhythmia after catheter ablation of atrial fibrillation (AF) in the form of atypical atrial flutter (AFL) is common among a significant number of patients and often requires redo ablation with limited success rates. Identifying patients at high risk of AFL after AF ablation could aid in patient selection and personalized ablation approach. The study aims to assess the relationship between pre-existing atrial cardiomyopathy and the occurrence of AFL following AF ablation. METHODS AND RESULTS: We analysed a cohort of 1007 consecutive AF patients who underwent catheter ablation and were included in a prospective registry. Patients who did not have baseline cardiac magnetic resonance imaging and late gadolinium enhancement (LGE-CMR) or did not experience any recurrences were excluded. A total of 166 patients were included gathering 56 patients who underwent re-ablation due to AFL recurrences and 110 patients who underwent re-ablation due to AF recurrences (P = 0.11). A multiparametric assessment of atrial cardiomyopathy was based on basal LGE-CMR, including left atrial (LA) volume, LA sphericity, and global and segmental LA fibrosis using semiautomated post-processing software. Out of the initial cohort of 1007 patients, AFL and AF occurred in 56 and 110 patients, respectively. An age higher than 65 [odds ratio (OR) = 5.6, 95% confidence interval (CI): 2.2-14.4], the number of previous ablations (OR = 3.0, 95% CI: 1.2-7.8), and the management of ablation lines in the index procedure (OR = 2.5, 95% CI: 1.0-6.3) were independently associated with AFL occurrence. Furthermore, several characteristics assessed by LGE-CMR were identified as independent predictors of AFL recurrence after the index ablation for AF, such as enhanced LA sphericity (OR = 1.3, 95% CI: 1.1-1.6), LA global fibrosis (OR = 1.03, 95% CI: 1.01-1.07), and increased fibrosis in the lateral wall (OR = 1.03, 95% CI: 1.01-1.04). CONCLUSION: Advanced atrial cardiomyopathy assessed by LGE-CMR, such as increased LA sphericity, global LA fibrosis, and fibrosis in the lateral wall, is independently associated with arrhythmia recurrence in the form of AFL following AF ablation.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Cardiomiopatías , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Ablación por Catéter/efectos adversos , Espectroscopía de Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA