Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros




Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 22(3): 514-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931062

RESUMEN

The Coherent X-ray Imaging (CXI) instrument specializes in hard X-ray, in-vacuum, high power density experiments in all areas of science. Two main sample chambers, one containing a 100 nm focus and one a 1 µm focus, are available, each with multiple diagnostics, sample injection, pump-probe and detector capabilities. The flexibility of CXI has enabled it to host a diverse range of experiments, from biological to extreme matter.


Asunto(s)
Cristalografía por Rayos X/instrumentación , Rayos Láser , Imagen Molecular/instrumentación , Aceleradores de Partículas/instrumentación , Espectrometría por Rayos X/instrumentación , Rayos X , California , Transferencia de Energía , Diseño de Equipo , Análisis de Falla de Equipo , Iluminación/instrumentación
2.
Science ; 337(6092): 362-4, 2012 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-22653729

RESUMEN

Structure determination of proteins and other macromolecules has historically required the growth of high-quality crystals sufficiently large to diffract x-rays efficiently while withstanding radiation damage. We applied serial femtosecond crystallography (SFX) using an x-ray free-electron laser (XFEL) to obtain high-resolution structural information from microcrystals (less than 1 micrometer by 1 micrometer by 3 micrometers) of the well-characterized model protein lysozyme. The agreement with synchrotron data demonstrates the immediate relevance of SFX for analyzing the structure of the large group of difficult-to-crystallize molecules.


Asunto(s)
Cristalografía por Rayos X/métodos , Conformación Proteica , Animales , Rayos Láser , Muramidasa/química , Muramidasa/efectos de la radiación
3.
Opt Express ; 20(4): 4525-36, 2012 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-22418212

RESUMEN

We present recent results on the inspection of a first diffraction-limited hard X-ray Kirkpatrick-Baez (KB) mirror pair for the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). The full KB system - mirrors and holders - was under inspection by use of high resolution slope measuring deflectometry. The tests confirmed that KB mirrors of 350mm aperture length characterized by an outstanding residual figure error of <1 nm rms has been realized. This corresponds to the residual figure slope error of about 0.05µrad rms, unprecedented on such long elliptical mirrors. Additional measurements show the clamping of the mirrors to be a critical step for the final - shape preserving installation of such outstanding optics.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA